Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC C O JOGESHWAR CHINTEY DUSUTIMUKH PO KHUBALIA PS DHEMAJI DIST DHEMAJI PIN 787057 ASSAM | DHEMAJI | ASSAM | 787057 | ₹1.3 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.3 Cr+₹1.5 L (1.10%)Rejected-AOC VILL PO RONG KOP TINIALI PS JONAI DIST DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | ₹1.3 Cr+₹1.5 L (1.10%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.5 Cr+₹14.7 L (11.1%)Rejected-AOC CHEGELI POTHER P O JIADHAL CHARIALI P S DHEMAJI DIST DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | ₹1.5 Cr+₹14.7 L (11.1%) | L3 | Rejected-AOC Rejected |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically non responsive |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
30 Dec 2019, 2:00 pmClosed
Director of Agriculture, Assam
Directorate of Agriculture,Assam,Khanapara,Ghy-22
Construction of Soil Testing Quality Control and Input Testing (STQCandIT) Laboratory at Dhemaji
2019_DAASC_15351_1
A/E/4776/STQCIT/RIDF2/19-20/17
Open Tender
Civil Works
Works
270 days
Dhemaji
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Directorate of Agriculture
₹3.0 L
Yes
Directorate of Agriculture,Assam,Khanapara,Ghy-22
5 Sept 2020
18 Dec 2019
30 Dec 2019
18 Dec 2019
30 Dec 2019
19 Dec 2019
24 Dec 2019
Amount
CIVIL WORKS
Earth work in excavation for foundation trenches of walls, retaining walls, Footing of Columns, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m. below the existing G.L. Ordinary Soil
Main Building-Total
Extra over item above for each 1m depth or part thereof beyond the initial depth of 2m
Total
Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.Main Building Plinth,Deduction in front area,Left side Near Corridor area
Total
NOMINAL MIX. ( P.C.C. WORKS )
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1 cement : 3 sand : 6 coarse aggregate by volume
Footing no.1,3,5,6,8,10,11,12,14,15,17,19,20.Footing no.2,4,7,9,13,16,18.Tie Beam
Main Building-Total
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5: 3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Ground Floor-Total
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). Using Mixer Machine.In substructure upto plinth level.Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick.M20 grade concrete or prop. 1:1.5:3
(Main building)Total upto tie beam
In super structure. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing.M20 grade concrete or prop. 1:1.5:3
Main building
Extra over above for each subsequent floor or part thereof above the 1st floor level.
(First floor).Main building
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Main building
Sides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties.Tie beam, beams, lintels.
Total (Main building)
Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas, balcony and the like Floors etc. upto 200 mm in thickness
Main Building-Total
Staircase with sloping or stepped soffits including risers and stringers but excluding landing .
Main building
Providing form-work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and wall etc. of insitu reinforced concrete works upto first floor level. Thickness not exceeding 200 mm.
Total (Main building)
Extra for each subsequent floor or part thereof above the 1st Floor level in beams, lintels, slab, chajja etc.
Extra for each subsequent floor or part thereof above the 1st Floor level in beams, lintels, slab, chajja etc.
BRICK WORK
Providing brick flat soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete.Brick on flat soling.
Total (Main building)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary.In proportion 1:4.
Main Building-Total
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). 115 mm thick brick wall. In cement mortar in proportion 1:4.(1 cement:4 sand).
Ground Floor-Total
First Floor-Total
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.
FLOORING
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
Normal range Somany/ Orient/Nitco/Asian Make Of size 200mmx300mm and above
Ground Floor and First Floor -Total
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
Executive range-Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Of size 800mmx800mm and above
Total
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.CERAMIC.Normal range (Sizes 300 mm x 300mm and above).Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
Ground Floor and First Floor -Total
VITRIFIED Executive range-2 (Sizes 600 mm x600mm and above). Somany made- Duragres (Glazed Vitrified Tiles) (605x605) mm. Gress VC Shield
Total staircase
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).
Normal Quality.With White cement
CEMENT PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
On rough side. In cement mortar 1:3. Ground Floor
First Floor-Total
On fair side. In cement mortar 1:3.
Ground Floor-Total
First Floor-Total
Cement plaster skirting with cement mortar in proportion 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.(15mm thick).
Total
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary). 9.5mm MRB
Ground Floor,first floor-Total
PLYWOOD / HARDBOARD PARTION
Providing, fitting and fixing in position plywood / hardboard partion walls with 6mm thick plyboard / hardboard (best) with horizontal and vertical Sal battens of size 50mm x 80mm spaced at not more than 1.20m apart with necessary nails, wood screws, bolts etc. complete as directed by the Department for all levels (Painting / Varnishing to be measured and paid separately).
6mm thick Plyboard.On one face of the frame
ROOFING
Providing Bare Galvalume Sheet Roofing at all levels including fitting and fixing self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.)TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
0.50 mm thick.Staircase headroom
Providing Bare Galvalume Sheet roofing accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete.TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
0.50 mm thick. Length of Ridge
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
WOOD WORKS
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows
With sal wood
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws.
One face decorative and other face nondecorative type and block board core.
35 mm thick
Providing, fitting and fixing Bison Panel board (Cement Bonded Particle Board) door shutters fixed to 100mmx38mm wooden frames with necessary hinges, screws, bolts etc. including painting of door shutters (one coat primer and two coats painting) complete as specified and directed by the department for all floors (Door fittings to be measured and paid separately)
Using 10mm thick board.Both sides laminated
GRILLS
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
Plain grill. Fixed to Brickwork/P.C.C/R.C.C.
Ground Floor,first floor-Total
Extra for providing security grill welded to casement window frames With 16 mm diameter MS round placed horizontally at a distance of 10 cm c/c @ 15 kg / 16 kg per squqre meter as per approved drawing.
Ground Floor,first floor-Total
ALUMINIUM WINDOWS
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.
2 track sliding windows.5 mm frosted glass
Ground Floor,first floor-Total
5 mm clear glass
Ground Floor,first floor-Total
3 track sliding windows.6mm clear glass
Ground Floor,first floor-Total
ALUMINIUM PARTITION
Providing, fitting and fixing anodised aluminium partition walls of standard sections of approved brand, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels.
Prelaminated Board
Ground Floor,first floor-Total
Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the department at all levels.
6mm thick glass panes and 12mm prelaminated board.Ground Floor,first floor-Total
P.V.C. DOORS & DOOR FRAMES
Providing, fitting and fixing 40 mm x 48 mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.
Ground Floor,first floor-Total
Providing, fitting and fixing 24 mm / 29 mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately).
29 mm thick. Ground Floor,first floor-Total
PAINTING
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
Thickness = 1.5 mm thick
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying priming coat with ready mixed paint, wood primer (pink) over new wood based surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
With ready mixed paint, wood primer (pink)
Painting two coats surfaces over 100mm in width or grith (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping.
Surface over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolac)
Applying primary coat with ready mixed "red -lead /red-oxide" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
With ready mixed 'red-lead/ red oxide' primer
Painting two coats Surfaces over 100mm in width or grith (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter.
Surface over 100mm in width or girth.High gloss (Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolac)
DOOR FITTINGS
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
Sliding door bolts.250mm x16mm sliding door bolt.
Tower bolt
200mm x 12mm tower bolt.
150mm x 10mm tower bolt.
Door handles.150 mm
REINFORCEMENT
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL.Super Ductile (SD) TMT reinforcement bars
ROOF TRUSS
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Using other ISI marked approved circular hollow section
DOOR FRAMES
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mm x40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to al steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates). for staircase head room
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
PLINTH PROTECTION WORKS AND PERIPHERY DRAINS
Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast RCC slab over drain, septic tank etc. in proportion 1:2:4 reinforced with 10 mm MS bar @ 150 mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as directed.75 mm thick slab
Infront Entry Side,Left Side near Corridor-Total
ANTI TERMITE TREATMENT
Pre construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from the the bottom of the excavation made for column, plinth beam, wall trenches etc by applying the emulsion @ 5 litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution and water i.e. 1% solution.
Total
Pre construction anti-termite treatment in the backfill in immediate contact with the foundation structure after completion, coolumn, wall etc. to a depth of 450 mm and width 300 mm (when required refill in 200 mm thick layers) applying the emulsion @ 5 litres per square meter towards the concrete and masonry wall so as to ensure earth in contact with the structure well treated with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
With aqueous emulsion having concentration 1:19 with chloropirophose solution and water i.e. 1% solution.
Tie beam. Main building(total)
Pre construction anti-termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
Pre construction anti-termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and directed by the department upto a depth of 300 mm along the line making rod holes @ 150 mm apart upto a depth of 300 mm and applying the emulsion @ 4.5 litres per running meter ensuring moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
With aqueous emulsion having concentration 1:19 with chloropirophose solution and water i.e. 1% solution.
Water proofing
Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat.
Site Clearence
Felling and removing. Cutting and clearing bushes consisting of plants and all sorts of bambooes including uprooting and removing as necessary and filling up the holes with earth, dressing, ramming etc. complete.
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
FIRE EXTINGUISHER
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Sanitary and Water Supply Works
EUROPEAN TYPE WATER CLOSET
Providing fitting and fixing vitreous China pedestal type water closet (European type WC pan 400 mm high) with seat and lead, CP brass hinges and rubber buffers, CI / MS brackets, 40 mm diameter flush band withfittings including painting of fittings and brackets, required. Hindware make.White
Water closet MALIBU "P (Cat.No.20086) (inclusive of seat cover)
PVC FLUSHING CISTERN
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc.
Hindware make.White. Sleek+ PVC cistern
URINAL
Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
Hindware make.White. Urinal Corner (Cat.No.60004)
WASH BASIN
Providing vitreous China wash basin with CI / MS brackets, CP brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately).
Table Top Basin.Hindware Make.White. Alto 460 x 460 (Cat. No.91018)
LABORATORY SINK
Providing fitting & fixing laboratory sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately.
Parryware Make.White.Lab Sink 450mm (Cat.No.C0602)
MIRROR
Providing fitting and fixing Mirror with plastic frame of size 500 x 400mm complete as directed and specified. Quantity for Bongaigaon-6, Lakhimpur-6 and Nalbari- 6
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified.
Parryware Make. Recess SP & SG dish (Cat. No. C9935)
TOWEL RAIL,TOWEL RACK & TOWEL RING
Providing, fitting and fixing CP towel rail complete as directed and specified.
Jaquar make Jaquar make. Continental 300mm for wash basin (Cat.No. ACN-1101N)
TUMBLER HOLDER,PASTE AND BRUSH HOLDER
Providing, fitting and fixing Chrome Plated brush holder complete as directed and specified.
Jaquar make. Continental (Cat.No. ACN-1143N)
TOILET PAPER HOLDER
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.
Jaquar make. Continental toilet paper holder (Cat.No. ACN-1151N)
WASTE COUPLING
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.
Jaquar Make. 32 mm (HT / FT) (Cat. No. ALD-705 / 709)
PVC PIPES, BENDS, JUNCTIONS, TEES ETC.
Supplying, fitting and fixing PVC pipes of 6.00 kg / cm² (Supreme / Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below GL as directed and specified. Concealed by chiselling or breaking brick wall / CC / RCC and making good to the damages.75mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme / Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below GL as directed and specified. Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.75 mm dia.
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
In exposed surfaces or in trenches. 75 mm x 75mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
In exposed surfaces or in trenches. 75 mm x 75mm
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified.75 mm
GRATING
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. 75mm dia
C.P. Grating. 75mm dia
Piping
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed
uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)
160mm diameter
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified.
Exposed or in trenches. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
Exposed or in trenches. 50 mm dia
Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.
50 mm dia
25 mm dia
BIB COCK
Supplying fitting and fixing CP bib cock 15 mm diametre of approved brand directed and specified. (GI and CP pipes will be measured separately).Jaquare make.Continental /Clarion
Standard
STOP COCK
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified.Brass stop cock (heavy) of Sant make
25mm dia
FLUSH COCK
Supplying fitting and fixing Chrome Plated (C.P.) flush cock of approved brand as directed and specified. Jaquar brand.Continental / Clarion
Flush cock with wall flange 25mm with lever knob
INTERNAL ELECTRICAL WORKS MAIN LABORATORY BUILDING
SCHEDULE ITEMS
Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
Medium point up to 6.00 metre. Length.
Long point up to 10.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Long point up to 10.00 metre. Length.
MODULAR SWITCH
fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.
1-2 module type Metal
3 module type Metal
4-5 module type Metal
6-8 module type Metal
12-16 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.
1 module
2module
3 module
4 module
6 module
8 module
10 module
16 module
Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department.
Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection.
Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection.
FITING AND ACCESSORIES
Supplying and fixing of 250/305 mm dia (Nominal size flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder, 20 Watt CFL lamp including connectionas required.
Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
SWITCH GEAR & PROTECTION INDUSTRIAL SOCKETS, DB Without MCB & MCCB , MCB, RCCB, RCBO, SFU, CHANGE OVER ETC. (ABB, Schneider MG, legrand, Hager make)
Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection. 20A Capacity. (ABB, Schneider MG, legrand, Hager make)
MCB DB (ABB, SCHNEIDER MG, LEGRAND, HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDOASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.)
MCB IN-comer SPN DB
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make)
8 way SPN Double Door
12 way SPN Double Door
MCB IN-comer TPN (Horizontal DB)
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make) 8 way TPN (4+24) double door
MCB, MCCB, RCCB, RCBO (ABB, SCHNEIDER MG, LEGRAND, AND HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDO ASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.) MCB (Conform to IS / IEC 60898-1:200/ MCCB (Conform to IS/IEC 60947- RCCB (Conform to IS/IEC 12640 / 61008)
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection.
C Series(Schneider MG, legrand, Hager make).6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series(ABB, Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 63A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 40A
EARTHING
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection.
Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection.
CEILING FAN, EXHAUST FAN AND AIR CURTAIN
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection.
Standard model 1200 mm Sweep Usha make)/ Standard model 1050 / 1200 mm Sweep Havells make)/ High speed 1200 mm sweep (ORIENT PSPO make).
Standard model 1400 mm Sweep. "ORIENT PSPO make) / Usha make)/ CROMPTON make)/ Havells/ ATC/ V GAURD make).
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Trans Air 300 mm sweep (Crompton make)
OVER HEAD LINE
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
LUMINAIRIES
Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department.
Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department.
NON SCHEDULE ITEMS
MAIN LT PANEL-SOIL LABORATORY BUILDING
Incommer:
Outgoing:
k) 40A 4P MCB - 1 No. l) 63A 4P MCB - 2 Nos. m) 32A 4P MCB - 2 Nos. n) 40 A DP MCB - 6 Nos. o) 32A DP MCB - 3 Nos.
Analysis Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade.
PARKING SHED
Area of Ground floor = 100 Sqm
EARTH WORK
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
Extra over item above for each 1m depth or part thereof beyond the initial depth of 2mb
Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.
NOMINAL MIX. ( P.C.C. WORKS )
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). In prop. 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1: 1.5: 3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORECED CEMENT CONCRETE WORKS
Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). In substructure upto plinth level Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick.
In super structure Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing.
FORMWORK
Providing form-work of 12mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 M. And removal of the same for in-situ reinforced concrete and plain concrete work in.
Columns, pillars, posts, & struts of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Sides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties. For depth not exceeding 1.0M
BRICK WORK
Providing brick flat soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete.
Brick work in 1:6 cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub-structure upto plinth level.
112mm thick 1st class brick nogged wall in 1 cement : 4 sand mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor ( Protruding M.S. rod / Tor Steel of column to be embedded in cement morter and will be measured and paid for separately ).
FLOORING
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). Delux range Of size 300mmx450mm and above
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) c) Delux range (ii) Of size 1200mmx1600mm and above
Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). SUNROCKHi CTS TILES Old Castle (455x455) mm
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. CERAMIC Executive range-2 (Sizes 600 mm x 600mm and above) Deluxe -Rotto VC
CEMENT PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On rough side In cement mortar 1:4
On fair side In cement mortar 1:4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. 15 mm thick
ROOFING
Providing colour coated DURASHINE/TATA BLUESCOPE zinc-aluminium profile sheet (total coated thickness=0.45mm) of nominal 1015mm effective cover width and nominal 28mm deep ribs with subtle square fluting in the five pan at nominal 203mm centre-to-centre including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) DURASHINE TILE PROFILE (0.50mm(TCT) x 505mm)
Providing colour coated DURASHINE/TATA BLUESCOPE zinc-aluminium roof , wall and tile profile sheet accessories (total coating thickness=0.45mm) including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) Plain Ridge
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
WOOD WORKS
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. Non decorative type and block board core. 35 mm thick
PAINTING
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) Thickness = 1.5 mm thick
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing wall with water proofing weather coat smooth anti-fungal exterior painting of Ace brand of Asian Paints and of required shade on old/new wall surface after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying priming coat with ready mixed paint, wood primer (pink) over new wood based surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. With ready mixed paint , Wood primer (pink)
Painting two coats surfaces over 100mm in width or grith (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping. Surfaces over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat with ready mixed "red -lead /red-oxide" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats Surfaces over 100mm in width or grith (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter.
Surfaces over 100mm in width or girth.High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
GRILLS
Providing, fitting and fixing M.S. grill of required Plain grill pattern for windows / clerestory windows / openings Fixed to Brickwork / P.C.C / R.C.C. with M.S. flats at required spacing in frame all round, square or round M.S. bars with round headedbolts and nuts or screws. Plain grill Fixed to masonry/RCC
DOOR FITTINGS
Supplying, fitting, fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for wood screws including necessary necessary screws etc. complete. Tower bolt 200mm x 10mm tower bolt.
Door handles 150 mm
ALUMINIUM DOORS AND WINDOWS
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 2 track sliding windows 5 mm frosted glass
REINFORCEMENT
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL Super Ductile (SD) TMT reinforcement bars In Sub-structure In Super-structure
ROOF TRUSS
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
DOOR FRAMES
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed.
PLINTH PROTECTION WORKS AND PERIPHERY DRAINS
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm drain with brick work in cement mortar in prop 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plaster in prop 1:3 finished with a floating coat of cement slurry as directed with necessary earth work in excavation of foundation trenches and refilling the sides after completion of work as specified.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. 100mm thick slab
ANTI TERMITE TREATMENT
Pre construction anti-termite treatment at the bottom of the foundation pits and walls on all sides upto a height of 300 mm from bottom of the excavation made for column, plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
Pre construction anti-termite treatment in back filling in immediate contact with the foundation structure after completion of column wall etc. to a depth of 450 mm and width 300 mm (when required refill in 200 mm thick layers) by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight) (Nagaon=13.92 sqm , Morigaon=13.92 sqm )
Pre construction anti-termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
Pre construction anti-termite treatment by applying the soil along the external perimeter of the building after completion of construction to a distance close to the plinth wall as specified and as directed by the department upto a depth 300 mm making rod holes at 150 mm c/c upto 300 mm below by applying the emulsion @ 4.5 (four point five) litres per running meter ensuring moistening of the soil with the emulsion. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
Sanitary Works for the PARKING SHED
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm Hindware make
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) Hindware make.White Sleek+ PVC cistern
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Jaquar make. White Urinal (Cat. No.URS-WHT-0704) with Sensor (Cat. No.SNR-CHR-51097)
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. Hindware Make.White Division Plate 680 x 300 (Cat. No.61001).
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)
BASIN (without pedestal), Parryware Make. Tapti Basin 500 x 360 (Cat No.C0424/410).
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.Jaquar Make.Continental
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. Jaquar Make Kubix (600mm long)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. Jaquar make Continental towel ring square
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified Agmeco make Concert
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. Sona Rupa 32mm (HT/ FT) (Cat.No.WS-0801)
Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified. Sona make.Pipe for bottle trap 300mm long (Cat. No.BT-0761)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 110mm dia. PVC cowel of ISI make
C.P. Grating 110 mm dia
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Water Supply Works for the PARKING SHED
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe
In exposed surfaces or in trenches.
25 mm nominal outer dia pipe
50mm nominal outer dia pipe
Concealed pipe with cutting chases & making good the walls. 15 mm nominal outer dia pipe
20 mm nominal outer dia pipe (Nagaon=15 m , Morigaon=15 m )
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately). Agmeco brand
Bib Cock Two way with Flange CAT No.CC 00203/CAT No.CN 00203 (Nagaon=2 nos , Morigaon=2 nos )
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately)
Agmeco Brand 15mm dia(Male/ Female )
15mm dia(Concealed )
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Agmeco (classic).Round
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 50 mm dia
25mm dia
Internal Electrical Works for the PARKING SHED
SCHEDULE ITEMS
Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts.PVC conduit including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts including 5 pin 6 amp socket outlet make and 6 amp flush type switch earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit ceiling rose etc. complete Long point up to 10.00 metre. Length.
MODULAR SWITCH
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete. 6-8 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE. 8 module
Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE.
Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection.
FITING AND ACCESSORIES
Supplying and fixing of 250/305 mm dia (Nominal size flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder, 20 Watt CFL lamp including connection as required.
Supplying and fixing of Fan box with inbuild rod as required.
EARTHING
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required .
Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection.
Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection.
CEILING FAN, EXHAUST FAN AND AIR CURTAIN
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as required complete.
Standard model 1400 mm Sweep. "ORIENT PSPO make) / Usha make)/ CROMPTON make)/ Havells/ ATC/ V GAURD make)
LUMINAIRIES
Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required.
Striplite luminaries complete with VPIT copper ballast/ Electronic ballast and decorative end cap and 1 X 36 / 40 watt Fluorescent tube.(Crompton Greaves make) Model- DSG1114LDB CROMGOLD / DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD / DSG 1414EB PLANET GOLD with Super Saver / Super Brite Lamp. Or equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make.
Septic Tank (100 users)
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary. Up to a depth of 2.00m below the existing ground level. In ordinary soil.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete. In prop 1cement: 3 sand :6 coarse aggregate by volume.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work.
Using Mixer Machine. In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M20 grade concrete or Prop. 1:1.5:3. 3.1 Septic tank base
Brick work in cement mortar with first class Brick prop. 1:4
Providing form work of Ordinary Tinder Plank Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face. 3.1 Septic tank base
3.3 Buffer Wall, Outside wall & Slab
Cement Plaster skirting with cement mortar in prop 1:3
From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL Super Ductile (SD) TMT reinforcement bars
3.1 Septic tank base
Providing, fitting & Fixing 450 mm dia x 90 mm Thick CI Manhole cover
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Construction of filter bed in soak pit including earthwork in excavation.
Boundary Wall
Plain cement concrete work of size 13 mm to 32 mm in foundation bad for footing etc. prop. 1:3:6.
Providing form work of Ordinary Tinder Plank
Foundation, footing, bases of columns, tie and plinth beam, pile cap, raft and mass concrete works etc Using 38 mm thick plank
Column, Pillars, Post, Struts etc.
REINFORCEMENT
Supplying, fitting & fixing in position reinforcement bar confirming to relevant I.S. code for RCC work.
Providing and lane plain reinforcement cement conctrete walls in proportion 1:1.5:3 i. In sub structure upto plinth level.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. a. Brick on flat soiling.
First class brick nogged wall in cement mortar including racking out joints and curing complete as directed a. 112mm thick brick wall.
15mm Thick cement plaster in single coat
15mm thicl plain cement mortar c. Raised band
PAINTING
Applying 1 coat of cement primer of approved brand and manufracture on new wall surface
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Nerolac Paints Limited of required shade on old/ new wall surface to give an even shade after cleaning and clearing the surface etc. including scaffolding com
BOREWELL
Preparation of site for placement of the drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed.
Movement of rig to the drilling site including cost of P.O.L. all complete as directed. Borewell no. 1
Transportation of all ancillary equipments, camp materials, welding set, rig, acessories etc.including cost of P.O.L. all complete as directed. For less than 100.00m Borewell no. 1
Transportation of all store materials like pipes, strainer, cone, socket, clamp, bentonite etc.including cost of P.O.F. all complete as directed. For less than 100.00m Borewell no. 1
Transportation of air compressor with all accessories including cost of P.O.L. all complete as directed. For less than 100.00m Borewell no. 1
Construction of temporary accomodation and low cost sanitary facility for drilling staff including cost of camp materials viz. cots, tables, chairs, utensils, dresses, safety helmets etc. and dismantling the accomodation after completion of the work all complete as directed.
Providing water supply facilities at drilling site all complete as directed. By installing 1 nos. of singur hand pump.
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete. Bore hole of 300mm diameter.
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete.
PVC PIPE SUPREME /PRINCE / FUSION /SFMC Brand.110mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.
PVC PIPE SUPREME / PRINCE / FUSION /SFMC Brand. 40mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. 40mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
80 mm dia nominal bore
supplying and packing pea gravel around the periphery casing including screening, washing etc. all complete as directed
PUMP HOUSE
EARTH WORK
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc up to a depth of 2 M below the existing ground level including refilling (return filling) the quantity as necessary after completing of work, breking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard / dense soil including bailing out water where necessary as directed and specified.
Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.
NOMINAL MIX. ( P.C.C. WORKS )
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete In prop. 1 cement : 3 sand : 6 coarse aggregate by volume.
REINFORECED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work.Using Mixer Machine.In substructure up to plinth level.Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.M20 grade concrete or Prop. 1:1.5:3
In super structure from plinth level up to 1st floor level.Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.M20 grade concrete or Prop. 1:1.5:3
TIMBER SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.Floors etc. upto 200mm in thickness.
Providing form work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level.Thickness not exceeding 200mm.
BRICK WORK
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level.112mm thick brick wall.In cement mortar in proportion 1:4. (1 cement:4 sand)
FLOORING
25 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing complete as directed.
Cement plaster skirting with cement mortar in proportion 1 cement : 3 coarse sand finished with a floating coat of neat cement. Including rounding of junctions with floor.15 mm thick
CEMENT PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
On rough side.In cement mortar 1:3
On far side.In cement mortar 1:3
WOOD WORKS
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels
35 mm thick .
PAINTING
Applying one coat of cement primer of approved brand and manufacture on new internal wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth..Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. Surfaces over 100mm in width or girth.High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.Surfaces over 100mm in width or girth.High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Nerolac Paints Limited of required shade on old/ new wall surface to give an even shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
DOOR FITTINGS
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
Sliding door bolts.250mm x16mm sliding door bolt.
Tower bolt.200mm x 12mm tower bolt.
Door handles.150mm
GLASS FITTINGS
Providing and fixing 3.00mm thick clear sheet glass (Area of glass panes not excedding .15sq.m.) bedded in putty and fixed with / without wooden beadings including necessary cutting and glass to be required sized.
REINFORCEMENT
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc.
DOOR FRAMES
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed.
STEEL WINDOWS
Providing, fitting and fixing steel windows / ventilators (openable) of standared rolled steel sections as per relevant I.S. Code - 1038 joints mitred and welded with 15mm x 3mm x 100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stay of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint.
Extra for providing security grill welded to casement window frames with 16mm dia M.S. round placed horizontally at a distance of 10 cm @ 15kg/16 kg per sqm as per approved drawing.
Motor Pump Set
Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt.
2 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt.
Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel.
STAGING WITH OVERHEAD TANK
PAINTING
Applying primary coat with ready mixed "red -lead /red-oxide" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats Surfaces over 100mm in width or grith (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter. Surfaces over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Steel work welded in built up sections, framed work including cutting, hoisting and fixing in positions and applying priming coat of red-lead paint including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. In beams and joists with connecting plates/ angled cleat
WATER TANK
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. 2000 Lt capacity.Sintex make
WASTE DISPOSAL AREA
EARTH WORK
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling(return filling) the quantity as necessary after completing of work, breking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard / dense soil including bailing out water where necessary as directed and specified. (A)Up to a depth of 2 M below the existing ground level. In ordinary soil
Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.
NOMINAL PCC WORK
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beam, steps, wall brick works etc, as directed and specified including dewatering if necessary and curing complete In prop 1 : 5 : 10 by volume
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concretewith coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). Using mixture machine
In substructure upto plinth level Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. Prop 1:1.5:3
TIMBER SHUTTERING (FORMWORK)
Providing form-work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 M. And removal of the same for in-situ reinforced concrete and plain concrete work in.
Foundation, footing, bases of columns, tie and plinth beam, pile cap, raft and mass concrete works etc Using 38 mm thick plank
BRICK WORK
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub-structure upto plinth level.
In cement mortar in prop 1:6(1 cement:6 sand)
CEMENT PLASTERING
15 mm thick 1:4 cement plaster in single coat on rough side of single or half brick wall for interior plastering upto 1st floor level including arises ,internal rounded angles not exceeding 80 mm girth and finish even and smooth including curing complete.
Cement plaster skirting with cement morter 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of junctions with apron in plinth wall.15 mm thick
PAINTING
White washing with lime on wall surfaces (two Coats) to give an shade including throughly brooming the surface to remove all dirt , dust , mortar drops and other foreign matter.
REINFORCEMENT
Supplying, fitting and fixing in position TMT reinforcement bars conforming to relevant I.S. code for R.C.C. work / R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). TMT bars
APPROACH ROAD
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.Other than Guwahati city
Compacting Original Ground Case-I : Compacting original ground supporting subgrade ( Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction.)
Granular Sub-base with Close Graded Material (Table:-400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per cl. 401( with an initial lead of 5 Km.) for grading-I Material
Cost of haulage excluding loading and unloading for a distance of 12 kms on surfaced gravel road.
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fill up the interstices of coarse aggregate, watering and compacting to the reqd. density ( with an initial lead of 5.0 km.) By Manual Means Grading I.Using Screening Crushable type such as Moorum or Gravel
Cost of haulage excluding loading and unloading for a distance of 64 kms on surfaced gravel road.
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165mm respectively, 250mm high in M20 grade PCC on M10 grade foundation 150mm thick, foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
Providing and laying 80 mm thick factory made cement concrete paver block of M - 30 grade factory made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50 mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer - in - Charge at all levels. A. SUNROCK HIGH CTS tiles (Pavers) (a) (Pavers) 80mm thick
DRAIN Work
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling(return filling) the quantity as necessary after completing of work, breking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard / dense soil including bailing out water where necessary as directed and specified. Upto adepth of 2.00m below the existing G.L In hard / dense soil Drain of 450 mm average depth
CEMENT CONCRETE WORK
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). In prop. 1 cement : 3 sand : 6 coarse aggregate by volume Drain
BRICK WORKS
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. In proportion 1:5 (1 cement : 5 sand) 230 mm thick 230 thick boundary wall side )
230 thick landscape side
PLASTER WORK
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. 15 mm thick
AIR CONDITIONER
Supplying with installation testing and commissioning of Hi -- wall 4 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. (Carrier make) Kurve/ Voltas make) Model PLATINUM 4S
EXTERNAL ELECTRICAL WORKS MAIN LABORATORY BUILDING
EARTHING
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required.
Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection.
Supplying & laying of following 25mmX5MM size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection.Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
FITING AND ACCESSORIES
Supplying and fixing of 40 mm dia hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) for street light water tight bracket including bending to shape and Wiring with 1.5 sq. mm size aluminium weather proof PVC cable etc. as required.
STREET LIGHT LUMINAIRES AND PANEL BOARD
Supplying with fitting & fixing of the following integral type street light luminaries complete and consisting of single piece integral epoxy gray powder coated dia cast aluminium housing gasket, pot optic reflector, cast aluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp Holder, Ballast, lamp etc. in the existing pole including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable. Philips make) Cat No.SRP 308 1xSON 70W FG For Lamp SON70W / Crompton Greaves make) SSSG12071H/FG For lamp 1x70W HPSV (/ Havells make): LHRS13170A99 For lamp 1x70W SON-E.
U. G. CABLE AND CABLE WORKS
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make).
3 Core A2XWY A2XFY
4.00 Sq.mm 3 Core armoured U.G. cable
6.00 Sq.mm 3 Core armoured U.G. cable
3 & 1/2 Core A2XFY 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)
Core - 3 A2XWY A2XFY 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Core - 3 & 1/2 A2XWY A2XFY 120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supplying including installation of cast iron cable marker as specified and directed by the deptt.
CABLE KITS
Supply including fitting and fixing of Resin Cast type outdoor end cable Termination Kit for 3 Core/1.1 KV PILC cable (MS - SE For the following sizes including testing and commissioning.
120.00 , 150.00 & 185.00 Sq.mm., 3.5 Core cable.
NON-SCHEDULE ITEMS
Analysis Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum 165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items.
12mm x 2mm x 15 cm long, 2 strip copper Bus Bar - 1 set 6-32 Amp "L" series DP MCB - 1 No.
6 amp "L" series SP MCB as outgoing - 3 Nos.
25 KVA DIESEL GENERATOR SET
Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV
TECHNICAL DATA CJ25D5P GENERATOR SET SPECIFICATIONS 25/20 3. No. of Phases. 1 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. X 2.5 G2 3. No. of Cylinders. 3 4. Aspiration. Natural 5. Cooling. Water Cooled. 6. Governor. Mechanical 7. Battery Capacity Rating. 12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 4.8 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 AND 1 WITH STANDARD CONTROL PANEL
Earth work in excavation for foundation trenches of wall, retaining wall, footing of column etc
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete. In prop 1cement: 3 sand :6 coarse aggreg
Providing and lane plain reinforcement cement conctrete walls in proportion 1:1.5:3 i. In sub structure upto plinth level.
ii. In super structure from plinth level to first floor level.
Providing form work of 12mm plywood board. Sub sructure i. Foundation base of RCC column
Tie bean side
Super structure
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G a
Ornamental Grill
Fix to Brick work/ PCC/ RCC
20mm thick cement plaster in coats, backing coat 10mm & finishing coat 10mm thick on fair side
Apply 1 coat of cement primer of approved band and manufeacture on new wall surface.
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Nerolac Paints Limited of required shade on old/ new wall surface to give an even shade after cleaning and clearing the surface etc. including scaffolding com
Applying priming coat over new steel and other metal surfaces over 100mm in girth/width after preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.With ready mixed paint , Wood
Painting Two Coat over new steel and other metal with Enamel Paint
Jungle Cleaning uprooting of vegitation, grass, brush wood, sapling and trees not exceding 300mm grith and disposal of the same outside the periphery and lift up 1500mm
63 KVA Sub station
Earthing, supplying & laying of 8 AWG copper earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying, installation testing and commissioning of the following rating copper wound indoor/ out door type transformer complete including the payment to be made to power supply authority for supervission charge, labour charge, cost of L.T./ H.T meter etc. excluding the cost of load security) and making necessary arrangement for charging approval of the sub station from the compitent authority as directed and specified by the department, Transformer should be as per CEA guidelines as an ammended upto date upto KVA star rating upto 5 star.
Overhead Line
Supplying and fitting of galvanised LTT cross arm complete clamps, bolts, nuts etc.
Supplying and fitting of galvanised channel of 100mm x 50mm x 65mm x 2200mm long complete with claim, bolts, nuts, etc.
Supplying and erection of 11 KV pin insulator
Supplying and erection of 11 KV disc insulator 45 kn with hardware.
Supplying and erection of 11 KV 400 A gang operated switch
Supplying and erection of 11 KV 150 ADO fuse set
Supplying and erection of 5 KA lighting arrestor set
Supplying including installation of 4 inch dia CI earth pipe as completed
Supplying and fitting, fixing of HT danger plate
Supplying erection and commissioning of the following specification IS:2713:410SP hot deep galvanised steel tubelar pole
Demolishing Brick Work including Stackingand disposal of materials
Demolishing of CC floor in various thickness
Demolishing and removing Door/Window
Demolishing all type of roofing
Sri Bijoy Deori
Probin Dihingia
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .