Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹20.4 L+₹38,243.20 (1.91%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹21.1 L+₹1.1 L (5.44%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹23.8 L+₹3.8 L (19.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹23.9 L+₹3.8 L (19.2%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹24.8 L
EMD Value
₹49,520
Closing Date
21 Jan 2023, 6:00 pmClosed
GE (MES) Faizabad
Garrison Engineer Military Engineer Services Faizabad
PROVN OF 30 KW ROOF TOP SOLAR POWER GENERATION PLANT IN RECORDS DRC AT AYODHYA CANTT UNDER GE FAIZABAD
2022_MES_570951_1
8343/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Faizabad
₹49,520
Yes
5 Apr 2023
23 Dec 2022
23 Jan 2023
24 Dec 2022
21 Jan 2023
14 Jan 2023
Amount
Design, Supply, Installation, Errection, Testing and Commissioning of (on Grid Type) Grid connected Solar PV Plant of (30 KW*1) capacity with Solar PV modules, tool kit and HDGI mounting structure with fasteners, nuts & bolts with foundation in PCC (1:2:4) type B1 comprising the following accessories complete all as specified and directed by Engineer-in-Charge:-
(i) Solar PV Module of Crystalline - Si (Mono) solar technology should have efficiency more than 16%. (ii) The PV modules shall be with minimum 72 cell configuration with rated power of module ≥ 335 Wp certified for solar PV module power performance tested as per IEC 61215 (Design, qualification and type approval for Crystalline Si modules) and IEC 61730 (PV module safety qualification testing @ 1000 Volt DC or higher with IEC-2005 of approved Indian make. (iii) Photovoltaic modules shall carry a performance warranty more than 90% during the first 10 years and more than 80% during the consecutive 15 years. Further module cell shall have performance warrantly more than 97.5% during the first year of installation to get the maximum Performance of the System. (iv) The module mismatch losses for modules connected to an Inverter shall be less than 2%. (v) The SPV module shall be made up of high transmitivity glass & front surface shall give high encapsulation gain and the module shall consists of impact resistance, low iron and high transmission toughened glass. (vi) The module frame shall be made of Aluminium (non corrosion material), which shall be electrolytically compatible with the structural material used for mounting the modules with required No of Earthing for LA (Lightening Arrestor) 03 Nos, Inverter - 01 No., Structure -01 No., LOOP of DC -01 No. and AC Control system -01 No.. (vii) The terminals shall be connected to copper bus-bar arrangement. The junction boxes have suitable copper cable (As per site requirements) entry points fitted with cable glands as per recommendatoins of the manufacturer. (viii) Any type of Copper Conductor XLPE/PVC Insulated / sheathed / naked / flat / Standard / Solid etc required for connection from Solar Power Panel of system to DC/AC Supply upto and including connection to the existing system required to complete the solar system to be included in the unit rate quoted. (ix) MPPT inverter power condition unit.
Economical (a) Maximum efficiency 98.5%. (b) Opti Trac MPP tracking for best MPP tracking efficiency. (c) Active temperature management. (d) WIfi communication. Simple: (a) Three-phase grid feed-in, Grid voltage will be 415 volt. (b) Cable connection without tools. (c) DC plug-in-system. Flexible and future proof: (a) DC input voltage up to 1000V. (b) Integrated grid management functions. (c) Reactive-power capable. Inverter shall be approved Indian make. (x) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) for foundation/ Pedestal for the structure required to be deemed included in quoted unit rate. (xi) Supply, Installation, Errection, testing and commissioning of HDGI structure. Hot dip 4mm thick for 30 KW SPV systems with proper grouting PCC (1:2:4) type B1 which can with stand 150 KM high wind speed so that the system can not get uprooted from ground due to high wind pressure. (xii) Cost of lightening protection including Earthing's Air termination and other accessories i.e, strip, nuts, bolts, washers, insulations etc requirement for connecting the system as recommended by manufacturer to be deemed included in the unit rate quoted. (xiii) Cost of tullu pump electrically operated with 0.50 HP Single Phase AC Supply motor and having head not less than 20 mtr, necessary cable required for connection in PVC conduit heavy duty from existing nearest point to the motor starter and starter to motor, GI Pipe 15 mm bore (medium grade) and PVC flexible braided pipe with set including all accessories from the existing service tank installed at the roof top of the building for cleaning of system.
(xiv) Any damage to the existing roof treatment of any type due to the Installation of Solar Power System shall be Re-done/made good as per existing treatment. Cost of the same shall be included in the unit rate quoted. Nothing extra shall be admissible on this Account. (xv) Net Energy meter showing Power generated by the Solar Power System and total power used by the user to be deemed included in the rate quoted. (xvi) Fire Extiguisher Liqueified CO2 gas of capacity 10 Kg conforming to relevant IS or ISI marked complete as recommended by manufacturer to be deemed included in the unit rate quoted. (xvii) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted. Note :- (a) Cost of all the accessories from serial number listed in 1(i) to (xvii) is deemed to be included in unit rate quoted and nothing extra shall be admissible on this account. (b) Bank Guarantee will stand as per instructions issued by E-in-C's Branch time to time. (c) Design of Solar power system shall be uploaded by the contractor or submitted to tender Accepting Officer. (d) Any type / size / length of copper conductor required to make the solar sysem functional shal be be deemed included in the unit rate quoted. (e) Comprehensive Maintenance and Servicing including all requisite spares, consumeables items and T&P required for maintenance of complete SPV for two years after completion of work shall be deemed included in the quoted rates.
Supplying, laying, fixing and testing of cable of cross sectional area 50 Sqmm, 3.5 Core, 1100 Volts grade, heavy duty, XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric cable with aluminium conductor, laid in trenches or passing through pipes or laid under floor or through walls etc complete all as specified and directed.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in with excavated soil including spreading, levelling in layers not exc 25 cm thick, watering and well ramming complete all as specified and directed.
Removing excavated materials (soil) not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed.
M&L for clean, dry, unwashed river sand, laid in trenches / ducts for cushioning to cable complete all as specified and directed. NOTE: - The depth of cushion after punning shall be measured as 18cm.
Supplying and laying precast cement concrete cable cover, Class LV, type I, flat, size 250mm x 150mm x 40mm for protection of UG Cable all as specied and directed.
NOVA ENERGIE
Avion Industries
His And Her Enterprises
WAVESHAPES INDIA
SOLARIUM GREEN ENERGY PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .