| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹3.5 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹4.0 CrRejected-Finance 258 A LAKE TOWN BLOCK B | ₹4.0 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹4.0 CrRejected-Finance | ₹4.0 Cr | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | VOLTAS LIMITED L1 | GATES L2 | TRANSTECH L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying, installation, testing and commissioning of following capacity Air-Cooled Screw Chiller package complete with VFD (Variable Frequency Drive),hermetic/semi hermetic, Mono/multiple screw type compressor each with step less capacity control of 25 % to 100 % of the rated capacity, with microprocessor based control panel, motor, starter panel (VFD), machine mounted, air- cooled condensers with Copper tube and Aluminium fins, factory fitted chiller insulation, water flow switch , vibration spring Isolators, victaulic couplings, integral refrigerant piping and wiring with multiple circuits, automatic and safety controls mounted in central console panel and all mounted on a steel frame (complete as per specifications) i/c suitable foundation/mounting structure made of RCC/MS Structure i/c anticorosive paint, anti vibration pad, power control cable and connection inter connection etc. as per design approved by engineer-incharge. Motor shall be suitable for 415±10% 50 cycles. 3 phase AC supply. Refrigerant gas used shall be R-134a.
The chiller shall be Building Management System (BMS) compatible The system shall be in confirmation to IS : 16590 as amended upto date. BEE Star labeling as amended upto date and tested as per IS 16590. ---
3 nos. x 160 TR [2 Nos. (Working) + 1 No. (Standby)] = 480 TR. | 3 | Nos | 42,03,881 ₹1.3 Cr | 48,91,737 ₹1.5 Cr | 49,59,738 ₹1.5 Cr |
| 1.011. Minimum Cooling Capacity : 160 TR Screw BEE rated 4 star - (Actual Capacity @ following Design Conditions) | ||||||
| 1.022. Type of Refrigerant : R-134A | ||||||
| 1.033. Chilled Water 'In' : 12 Deg C | ||||||
| 1.044. Chilled Water 'Out': 7 Deg. C | ||||||
| 1.055. Chiller Fouling Factor : 0.0001 (FPS) | ||||||
| 1.066. The electrical panel should be IP55 protected (As per OEM Satndard) | ||||||
| 1.077. Air Entering Temp. to the Condenser : As per AHRI Condition. | ||||||
| 1.088. Minimum IKW/TR should be less than equal to 1.46 at design condition (Including Fan Power) | ||||||
| 1.099. Minimum COP at AHRI Condition not less than 3 & IPLV Minm 3.70 at AHRI conditions as per ECBC Plus gudiline. | ||||||
Tender Value
Refer Docs
EMD Value
₹8 L
Closing Date
23 Feb 2026, 2:00 pmClosed
Sr. SE, PEC, PWD
Office of Sr. SE, PEC, PWD, KIT Annex Bldg., 4th Floor, Kolkata-73
Construction of 100 bedded Critical Care Block (CCB) at Howrah District Hospital, Howrah - SITC of AC Machine.
2026_WBPWD_992526_1
WBPWD/SEPEC/NIT-05/2025-2026 (2nd call)
Open Tender
A/C ORG
180 days
Howrah District Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹8 L
OFFICE OF Sr. SE, PEC, PWD
3 Jun 2026
24 Jan 2026
25 Feb 2026
24 Jan 2026
23 Feb 2026
6 Feb 2026
2 Feb 2026
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_2427094.xls
BOQ • 0.44 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid