Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical AT KARGALI BAZAR BERMO DIST BOKARO PIN NO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical GUNJARDIH BHANDARIDAH BOKARO JHARKHAND PIN NO 829132 | BOKARO | JHARKHAND | 829132 | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹12.5 L
EMD Value
₹15,600
Closing Date
22 Mar 2024, 10:30 amClosed
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Work of (A) Installation of ESC type lighting arrester (B) Making of new industrial type earth pit and (C) Re- organisation of 440V OH line at Tarmi railway siding under SDOCM, Dhori Area
2024_CCL_304566_1
GM(D)/SO(EnM)/DA/2023-24/156
Open Tender
Electrical and Maintenance Works
Item Wise
7 days
Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,600
5 Apr 2024
11 Mar 2024
23 Mar 2024
12 Mar 2024
22 Mar 2024
12 Mar 2024
12 Mar 2024 - 15 Mar 2024
Amount
Part A: ESC type lighting arrester
Erection of steel tublor pole of length exceeding 16 mtr in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required (pole supply by department)
PROVIDING OF ESE TYPE LIGHTNING ARRESTER ADVANCED LIGHTNING ARRESTER WITH FOLLOWING FEATURES Tested & Certified by CPRI (Central Power Research Institute). Govt. of India for the impulse current of (8/20ps) in 70KA with 5 positive and 5 negative impulse. No External Power Supply will be provided. Protection Radius up to 107mtr in level-4 Protection minimum Height of 7mtr of lighting arrester with elevation rod.ESE LIGHTNING ARRESTER TO BE MADE BY STAINLESS STEEL.
Providing & fixing of '6' Digit None Resistible Lighting Event Counter with IP67 Enclosure to count lighting strikes.
Erection of Maintenance Free Earthling with following materials :- Earthing electrode : (Outer dia "50"mm and inner dia 40mm and stripe size 14x6, 2mtr long or 17.2sq.mm dia 2 mtr long copper bonded rod)with Back Fill Compound
Installation charges for ESE type lightning arrester advanced lightning arrester.
Providing and fixing 50mm X 6mm G.I. strip as required.
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
S/Erection of pin insulator 440v
Transporting of pole after making of 16 mtr pole
Cutting work for pole making
Welding work for pole making
Part B: Earthing Work
Erection of steel tublor pole of length exceeding 16 mtr in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required (pole supply by department)
Providing of 400Amp Gang Operating Swich
Fitting & fixing of 400Amp Gang Operating Swich
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of double pole 3 wire cross arm for 11KV over head lines as required.
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. 1. Spindle and nuts etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Applying and erection of 11 KV pin insulator complete with large steel ad G.I. pin, nuts, washers etc. as required.
Erection of Maintenance Free Earthling with following materials :- Earthing electrode : (Outer dia "50"mm and inner dia 40mm and stripe size 14x6, 2mtr long or 17.2sq.mm dia 2 mtr long copper bonded rod)with Back Fill Compound 1. 04 nos feeder freaker-08 nos 2. Pump house -05 nos 3. For transformer near kali madir -02 nos
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
S/E of clamps nut bolt etc
Providing & fixing of Gl Patti (size-50mmx6mm)
Providing of 16 sqmm copper calbe for earthing
Part C: 440 V OH line work
Erection of steel tublor pole of length exceeding 10 mtrs but not exceeding 12 mtr in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required (pole supply by department)
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. 1. Bolt, nuts and straps etc. as required
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 3.15 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Supply of 8 SWG GI wire for cradling
Ercetion of cradle wire 10 x 32 nos
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV over head lines as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Transporting of pole from dismantle place to proposed place
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
Dismantling of light set from top of the pole
Fitting of light set from top of the pole
Total impact of GST for the purpose of CTC
MAHTO ENTERPRISES
M/S SHIV PARBATI ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .