| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹35.9 L+₹2.8 L (8.37%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-Finance Not being a
lowest
tenderer | |
| 3 | L3₹38.2 L+₹5.1 L (15.3%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L3 | Rejected-Finance Not being a
lowest
tenderer | |
| 4 | L4₹40.5 L+₹7.4 L (22.3%)Rejected-Finance HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | L4 | Rejected-Finance Not being a
lowest
tenderer | |
| 5 | L5₹44.3 L+₹11.2 L (33.8%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance Not being a
lowest
tenderer |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Aug 2021, 6:00 pmClosed
GE BABINA
GE BABINA CANTT 284401
CERTAIN AND REPAIR/ MAINT WORKS TO WATER PIPE LINES CONTROL VALVES, RISING MAINS AND OTHER CONNECTED WORKS OLD CAMP, BOs LINE OFFICER ENCLAVE, MH CSQ AND OTHER ADJOINING AREAS AT BABINA CANTT UNDER GE BABINA
2021_MES_453352_2
GE/BAB/TOKEN/20 OF 2021-2022
Open Tender
Civil Works - Water Works
Item Rate
184 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹90,000
Yes
17 Sept 2021
30 Jul 2021
21 Aug 2021
30 Jul 2021
19 Aug 2021
7 Aug 2021
Amount
M & L for opening up short circuited / winding burnt electric induction motors of 5 to 7.5 HP capacity 3 phase AC 440 Volts, cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of same gauge and size suitable as per the existing including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified. Note - (i) Intimation for any unserviceable motor of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. (iv) Quantity of retrieved copper from rewinding of item shall be calculated as per standrad norms
All as per item No. 1 here in before but induction motor of 10 to 12.50 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 15 to 30 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 40 HP 50 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 60 HP to 75 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 90 HP to 100 HP capacity 3 phase AC 440 Volts, complete all as specified.
S & F terminal connector of 5 to 30 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
S & F terminal connector of 40 to 100 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
S & F of PVC fan blade for motors of 5 to 15 HP capacity complete all as specified.
S & F MS pump motor coupling of 15 HP to 30 HP as per the existing size and shape for pump sets
S & F MS pump motor coupling of 40 HP to 100 HP as per the existing size and shape for pump sets
M & L for motor end ball / roller bearing with good quality grease suitable for 5 HP to 15HP capacity pump sets
M & L for motor end ball / roller bearing with good quality grease suitable for 15 to 40 HP capacity pump sets
M & L for motor end ball / roller bearing with good quality grease suitable for 60 to 100 HP capacity pump sets
S & F rubber bush/belt coupling (set of 8) for motor 15 to 30HP complete all as specified and directed.
S & F rubber bush/belt coupling (set of 8) for motor 40 HP to 60HP complete all as specified and directed.
S & F rubber bush/belt coupling (set of 8) for motor 90 to 100 HP complete all as specified and directed.
M & L for dismantling and taking up/down u/s centrifugal pump sets of any capacity of any size from foundations/pumphouse after disconnecting electric & water connections and transportation from site to contractor's workshop for carrying out repairs to pump sets , replacement of unserviceable parts as required incl re-assembling, re-fixing in position, including connecting in original position & testing complete as directed and specified . Note - (i) Spares required to be replaced will be measured and paid separately. (ii) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor or pump will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted.
Supply and fix coupling key any size as per sample for pumping sets of different capacities complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 5 HP to 12.50 HP capacity complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 15 to 30 HP capacity complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 40 HP to 60 HP capacity complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 90 to 100 HP capacitycomplete all as directed and specified
M & L for carrying out replacement of pump impeller of 5 HP to 7.5 HP capacity complete all as directed and specified
M & L for carrying out replacement of pump impeller of 10 HP to 30 HP capacity complete all as directed and specified
S & F in replacement of gun metal bush complete set of two as per sample for centrifugal pump set 15 HP to 30 HP complete all as directed and specified
S & F in replacement of gun metal bush complete set of two as per sample for centrifugal pump set 40 HP of 100 HP complete all as directed and specified
S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 15 HP to 30 HP complete all as directed and specified
S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 40 HP to 60 HP complete all as directed and specified
S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 100 HP complete all as directed and specified
S & F in replacement of pump end ball bearing suitable for 15 HP To 30 HP complete all as directed and specified
S & F in replacement of pump end ball bearing suitable for 40 HP to 60 HP complete all as directed and specified
S & F in replacement of pump end ball bearing suitable for pump sets 100 HP. complete all as directed and specified
S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 15 HP to 30 HP capacity complete all as directed and specified
S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 40 HP to 60 HP capacity complete all as directed and specified
S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 100 HP capacity complete all as directed and specified
S & F in replacement of impeller intermediate gun metal collar valve guide same as per sample for double acting impeller 100 HP pump set complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 15 HP capacity. complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 30 HP capacity complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 40 HP capacity.complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 60 HP capacity complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 100 HP capacity complete all as directed and specified
M&L for taking out defective submersible pumping set of discharge capacity varying from 4000 to 12000 GPH from bore wells / shallow wells including dismantling and taking out column pipes of any bore & length alongwith submersible cable, steel wire rope etc; and re-lowering the pump set after carrying out necessary repairs / replacement of defective parts all as specified and directed. Note :- i) Costs of all necessary T&P and manpower required at site and transportation is deemed to be included in the rates quoted.
M&L for carrying out repair to submersible pump of 4000 to 12000 GPH capacity after dismantling the assembly for replacement of worn out spares such as stage bowls, impellers, pump shaft, sleeves, bushes etc; incl filling, turning & polishing works to pump shaft, GM impellers as necessiated, reassembling the pump after repairs and testing complete incl applying a coat of water proof epoxy paint to the external surfaces of pump all as specified and directed. (ii) Intimation for any unserviceable pump will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable pumps will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @Rs. 200/- per hour for delay period hour will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted.
S & F GM impellers with key and bushes suitable for 4000 to 12000 GPH capacity
S & F pump shaft stainless steel suitable for 4000 to 12000 GPH capacity
S & F non return valve for pump suitable for 4000 to 12000 GPH capacity
S & F bush for pump set suitable for 4000 to 12000 GPH capacity
S & F bowl assembly complete with stage bolts suitable for 8000 to 12000 GPH capacity
S & F neck rings for pump sets of any capacity
S & F stage bowl bush GM suitable for pump sets of any capacity
S & F distance sleeve suitable for pump sets of any capacity
M&L for water proof 'M' seal cable jointing kit with hardner compound, copper ferrule, sleeves, cotton / insulation tape and all materials complete suitable for submersible cable PVC insulated and sheathed, 6 to 10 sqmm flat, 3 core, 1100 volt grade complete all as specified and directed.
M&L for rubber gasket packing, 4 mm thick suitable for 50/80/100 mm dia flanged column pipes complete all as specified.
M & L for rewinding of submersible motors AC, 3 phase, 440 volt 4 to 15 HP with superior quality PVC insulated copper winding wire of identical gauge & specification of the existing short circuited winding wires with all necessary insulating materials incl cleaning of stator & slots and applying one coat of water proof epoxy paint to the exteriors of motor and testing complete all as specified on load of capacity. Note :- Any spares other than specified in the item will be measured and paid separately. (ii) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 100/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. (iv) Quantity of retrieved copper from rewinding of item shall be calculated as per standrad norms
M&L for repairs to rotor assembly of submersible motor of any size/make incl cutting & cleaning of defective copper strips from rotor slots, filling cavities, gas welding/bracing and finishing complete all as specified.
S & F motor bush upper and lower 4 to 15 HP for submersible motor complete all as specified.
S & F rotor bearing sleeve upper and lower suitable for submersible motor of any size/capacity complete all as specified.
S & F sand guard suitable for submersible pump set any size/capacity complete all as specified.
S & F motor thrust bearing assembly complete suitable for 4 to 15 HP complete all as specified.
S & F motor housing upper suitable for 4 to 15 HP complete all as specified.
S & F motor housing lower suitable for 5 to 15 HP complete all as specified.
S & F motor coupler sleeve with key suitable for submersible pump sets of any capacity.
Supply and fixing in replacement motor starter of capacity 30 to 60 HP capacity with new starter panel board for fixing of soft starter , consisting of 300 Amps copper bus bar, ampare meter , CTs , volt meter and power contactor of capacity 200 Amps , semiconductor fuses , LED indicator, MCBs , & necessory wiring etc. Starter LT panel should be indoor type floor mounting made out of 2mm thick CRCA sheet duly powder coated painting & including connecting cable of PVC insulated ISI marked copper conductor single core cable of size 25sqmm from starter to motor including supply and fixing new digital soft starter suitable for electric motor of capacity 30 to 60 HP 3 phase 415 volt with comprehensive motor protection, programmable over load protection, built-in RTD & Thermistor inputs with constant current adaptive accelaration & de-accelaration for smooth start and stop operation of motor of make L & T cat pt No. EMX3-0145B-411 or equivalent models of approved make including testing on load complete all as directed and specified .
S & F in eplacement of DOL starter suitable for 7.5 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 5-10A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. Make : BCH cat part No CPEANK or L&T cat No SS96228 or equivalent approved make.
S & F in replacement of DOL starter suitable for 10 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 8.9-13.5A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified. Make : BCH cat part No CPEANK or L&T cat No SS95647 or equivalent approved make.
S & F in replacement of electronic type single phasing preventor suitable for protection of electric motors 3 phase 415 V, AC, 50 Hz complete all as specified. Make : Minilec or equivalent approved make
S & F in replacement of cast iron sluice valve of 80 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Make:-Kirloskar/leader/upadhayay/sant Note:- Contractor will be intimated to replace the deffective sluice valve on telephonically followed by in written. Contractor has to arrange new sluice valves and complete the replacement work with 48 hrs after intimation failing which a penal recovery of Rs 400/- per hour will be charged from his payment. Contractor has to keep all required size sluice valve and T&P with manpower ready for fixing on urgent requirment and quote his rates accordingly.
All as per Srl item No. 69 here-in-before but 100 mm dia bore
All as per Srl item No. 69 here-in-before but 150 mm dia bore
All as per Srl item No. 69 here-in-before but 200 mm dia bore
All as per Srl item No. 69 here-in-before but 250 mm dia bore
All as per Srl item No. 69 here-in-before but 300 mm dia bore
S & F in replacement of gun metal gate valves of size 15 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/S gate valves all as specified and directed Make:-Kirloskar/leader/Zoloto
Discription as per item No 75 here in before but 20 mm bore
Discription as per item No 75 here in before but 25 mm bore
Discription as per item No 75 here in before but 40 mm bore
Discription as per item No 75 here in before but 50 mm bore
Supply only following items for various water supply installations :-
Supply only Nylon braided PVC flexible pipe, heavy duty 20 mm dia.all as per sample
Supply only Chlorine test kit with coloured sample complete with all testing fitments and 100 ml OT solution in rexine finish wooden box all as per sample.Make:-Aquajio technologies or equilent approved make
Supply only Chloroscope (Chlorine & PH test kit) for estimation of residual chlorine in water comprise of plastic box, two tube, droper colour filter for colour estimation.Make:-Aquajio technologies or equilent approved make
Supply only Water quality TDS tester with ATC,digital and pockettype. Range: TDS: 0-999PPM (Mg/L) Modle:ATDS0016 Make:-Aquajio technologies or equilent approved make
Supply only PH test kit(electronic, Digital and pocket type). Modle No: APH0025. Make:-Aquajio technologies or equilent approved make
Supply only Ortho tholodine solution in 500 ml bottle.
Supply only Crystal Alum (Ferric)
Supply only Copper Sulphate
Supply & fixing/ replacement of PVC core nylon brush 48 " long for suction sweeper (swimming pool claner)including necessary fittings including replacement of NRV & neceaasry fittings etc.
S&F in replacement PVC flexible corrugated pipe of size 50mm bore for suction sweeper as per sample complete all as directed and specified.
S & F in replacement of motor starter of capacity upto 100 to 150 HP motor, 3 phase 415 volt with comprehensive motor protection, programmable over load protection, built-in RTD & Thermistor inputs with constant current adaptive accelaration & de-accelaration for smooth start and stop operation of motor incl dismantling of u/s starter & installation / programming by skilled technician of original manufacturer, incl necessary mounting arrangement on existing panel such as fastener nuts & bolts and also fixing HRC fuse of suitable capacity onpanels with copper busbars etc as required complete all as specified and directed. Make : L&T Cat No EMX3-0255B-411or any equivalent models of approved make
Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed. Make : Aquafit or equivalent as approved by NMPT committee of E-in-C's Branch. Note :-The contractor must submit the COC (Certificate of Compliance) in original from manufacturer by All India Authorised MES Distributor for each batch of product delivered indicating and including Chemical Analysis Report by All India Authorised MES Distributor. Note :- 1. The contractor must submit the COC (Certificate of Compliance) in original from manufacturer for each batch of product delivered including chemical analysis report. Contractor has to get approval of Accepting officer before placing purchase order .
S & F in replacement including leakage testing of 3-layer PP-R polypropylene random copolymer pipes of 25 mm outer dia SDR 7.4 (PN-16) antimicrobial fusion welded incl all PR-R plain & threaded polypropylene random fittings laid in trenches, ceiling or floors etc incl fixing arrangements complete.Make:-SUPREME / PRINCE/Prayag/Ashirwad/Astral
S & F in replacement of PPR gate valve (brass insert) of 25 mm dia complete all as specified. Make :-SUPREME / PRINCE/ Astral/Prayag/Ashirwad
S & F including leakage testing of 3-layer PP-R polypropylene random copolymer pipes of 20 mm outer dia SDR 7.4 (PN-16) antimicrobial fusion welded incl all PR-R plain & threaded polypropylene random fittings laid in trenches, ceiling or floors etc incl fixing arrangements complete.Make:-SUPREME / PRINCE/Prayag/Ashirwad/Astral
S & F in replacement of PPR gate valve (brass insert) of 20 mm dia complete all as specified. Make :-SUPREME / PRINCE/Prayag/Ashirwad/Astral
S & F cast iron foot valves with flanged end in replacement 80 mm bore all as per including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed. Make:-Kirloskar/leader/upadhayay/sant Note:- Contractor will be intimated to replace the deffective foot vavle on telephonically followed by in written. Contractor has to arrange new foot valves and complete the replacement work with 48 hrs after intimation failing which a penal recovery of Rs 400/- per hour will be charged from his payment. Contractor has to keep all required size foot valve and T&P with manpower ready for fixing on urgent requirment and quote his rates accordingly.
All as per item No 89 here in before but foot valves with flanged end in replacement 100 mm bore all l as directed and specified .
All as per item No 89 here in before but foot valves with flanged end in replacement 150 mm bore all l as directed and specified .
All as per item No 89 here in before but foot valves with flanged end in replacement 200 mm bore all as directed and specified .
S & F in replacement of microprocessor controlled ACB, 4 Pole, 630 Amps 415 Volt AC, 50 Hz, rupturing capacity 50 KA with microprocerssor release IPR 2 systems against over load and short circuit conditions conforming to IS/IEC60947-2 all as directed and specified . Make : Havells / L&T/ Standard / LEGRAND/Schneider/Indo Asian.
S & F in replacement of MCCB, 4 Pole, 630Amps 415 Volt AC, 50 Hz, rupturing capacity 50 KA with adjustable thermal and fixed magnetic tripping systems against over load and short circuit conditions conforming to IS:13947 (Part-2) Ics = 100%ICU all as directed and specified . Make : Havells/ L&T/ Standard / LEGRAND/Schneider/Indo Asian.
All as per item No 94 here in before but MCCB of capacity 400 Amps 35 KA all l as directed and specified .
All as per item No 94 here in before but MCCB of capacity 250 Amps 35 KA all l as directed and specified .
All as per item No 94 here in before but MCCB of capacity 200 Amps 25 KA all l as directed and specified .
All as per item No 94 here in before but MCCB of capacity 125 Amps 25 KAall l as directed and specified .
All as per item No 94 here in before but MCCB of capacity 100 Amps 16 KA all l as directed and specified .
M & L for submersible cable, flat PVC insulated and sheathed, 3 core, 6 sqmm, multistranded copper conductor, 1100 volt grade, conforming IS-694, heavy duty complete all as specified and directed. Make - Havells/Gloster/Asian/Universal/Polycab/Finolex
All as per item 100 but cable of size 3 core, 10 sqmm, multistranded copper conductor, 1100 volt grade, heavy duty.
M&L for MS Fabrication work, made out of structural steel sections as in frame work for cable & piping ducts / MS door panels etc at water supply installations, MS angles / flats / plain sheets of appropriate gauge, cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shape or sizes as required including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
S & F of change over switch off load side handle operated with advanced neutral, OFF LOAD, 1000 Amps, 4 pole, AC 415 Volt, manual Change Over in sheet metal enclosure with operating handle conforming to IS:13947 (Part-3) complete all as specified and directed. Make : HPL/Standard/L&T
S & F of change over switch off load side handle operated with advanced neutral, OFF LOAD, 200 Amps, 4 pole, AC 415 Volt, manual Change over insheet metal enclosure including operating handle conforming to IS:13947 (Part-3) complete all as specified and directed. Make : HPL/Standard/L&T
M&L for repairs to FASD starter, AC 3 Phase, 440 V of 10 HP to 15HP capacity of any make incl replacement of all u/s spares, integral wiring with appropriate gauge, copper conductor cables, copper lugs, terminal block with brass bolts, nuts & washers etc all as specified. Make L&T/Havells/BCH Note :- 1. Spares to be replaced will be measured and paid seperately as supply only. 2. Cost of labour and copper lugs, terminal block with brass bolts, nuts & washers included in the quoted rate.
S & F contactor repair kit without coil suitable for 10 HP to 15 HP.
S & F power contactors of upto 40 amps 415 volts suitable for 10 HP to 15 HP.
S & F over load protection relay of suitable range suitable for 10 HP to 15 HP.
S & F electronic timer device 0-20 second delay suitable for 10 HP to 15 HP.
S & F of high performance LED street light fittings with pressure die cost housing toughened glass and LED with secondery optics of IP 65 protection of capacity 25 Watt power consumption complete, input voltage range of 140 volts (nominal rated voltage -240 volts , 50 HZ incl taking down of street light fittings of any type complete all as specified. Make -Phillips/Bajaj/ Crompton /Halonix
All as per item No 110 here in before but LED fitting of capacity 45 to 48 watt complete all as specified
All as per item No 110 here in before but LED fitting of capacity 70 to 72watt complete all as specified
M&L for GI bracket made out of 32mm dia GI pipe light grade 1.20 mtr long bend to shape or size and including clamps nut and bolts etc as directed at site for mounting street light complete all as specified and directed. Make : Jindal/Tata/Surya Prakash
M & L for opening of soft starter EMX 3 series of L&T make 40-100 HP capacity from the existing panel (by a skilled representative of original manufacturer) for servicing, repair, replacement, refixing of spares like control card (EMX3 Series), display, supply card, contactor, CT, fuses etc, tightening of loosen integral wiring, copper lugs, terminal blocks, nut and bolts, washers etc complete all as specified and directed by Engr-in-Charge. Note :- 1. The Manufacturers Rep or authorised service dealer representative/technician will be arrenged by contractor and necessary documents/ proof of technician will be produced to Eng-in-Charge before starting repair work. 2. spares to be replaced will be measured and paid seperately as supply only. 3. Cleaning of dust and other materials to be carried out only using of CRC 2-26. 4. Cost of skilled representative, tools, wiring, copper lugs, terminal blocks, nuts and bolts, cleaning materials, etc required at site included in the quoted rates. 5. If any damage occured in the spares during repair the same will be replaced by the contractorat at his own cost.
S & F in replacement control card of soft starter of suitable for 40 HP capacity complete all as directed and specified .
S & F control card of soft starter of suitable for 60 HP capacity. complete all as directed and specified .
S & F control card of soft starter of suitable for 100 HP capacity. complete all as directed and specified .
S & F power contactor of model ML-12, AC 3 phase, Cat No SS90935 of L&T make or equivalent model of approved make. complete all as directed and specified .
Supply only suitable CT for soft starter of 100 HP capacity complete all as directed and specified .
Supply only bolted type HRC fuse links of capacity 125 Amps to 250 Amps , 415 volts 80 KA Make - L&T/Havells/C&S/BCH complete all as directed and specified .
All as per item No 120 here in before but of capacity 315 amps to 600 Amps complete all as directed and specified .
Supply and laying in replacement under ground cable XLPE insulated PVC sheathed multistranded aluminium conductor cable armoured of size 16 sqmm 2 core 1100 volt grade in trenches/floors or on poles complete all as specified. Make - Gloster/Asian/Universal/Polycab/Finolex
All as per item No 122 here in before but cable armoured of size 25 sqmm 4 core 1100 volt grade
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in any type of soil (soft/loose/hard/dense soil) for laying / taking up / taking down of cables or taking down/erecting poles and getting out and levelling of bottom surface to required level all as specified and directed by Engineer-in-Charge.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified in the any type of soils
Removal excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified.
M&L for sub class 'B' bricks laid flat across the cable for protection all as specified
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:4) as in foundation of equipment, platform, ramp, supporting pillars of pipes, protection wall of UG sump incl demolistion of existing brick work built in cement mortar complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundations/foot path etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level including removal of debris complete all as specified and directed
M&L for plastering in CM (1:4) 10 mm thick on fair faces of brick work or concrete surface/ cable duct / floor including demolition complete all as specified and directed.
M&L for repairs to hand pump of water of exising make and size at different locations of Babina cantt and TKD area including replacement of head and handle assembly, plunger rod, GI pipe, reducer cap, upper & lower valve assembly etc of hand pump assembly dismantling from 100/150 mm dia bore well of any depth for cleaning, removing of scaled, muddy, corroded particle from the accessories and making hand pump functional complete all as specified and directed. Note- 1. This item include cost for extension of bore and lowering down additional length of pipe below water starta. Accessories for replacement / pipes shall be measured and paid seperately under respective items. Cost of labour for dismantiling, installing, testing and commissioning of hand pump is deemed to be included in the quoted rate. 2. All other minor items / spares / T&P etc which are otherwise not specified but essential to complete the work are deemed to be included in the quoted rates. contractor has to complete the work within 07 days after intimation on telephone followed in writing , failing which a penality of Rs 1000/ per day will be initiated and deducted from contractor's payment/RAR/final bill etc. Contractor has to quote his rates accordingly.
S&F in dismantle and taking out GI pipe from bore of hand pump and including boring upto water level avilable and replacement GI tube 32 mm bore, medium grade for riser pipes of hand pump of any length complete all as specified and directed. Note: - (a) New GI pipe 32mm size will be measured and paid under separate item here in after. (b) The item includes extension of bore holes to the depth of water level below ground for hand pump.
S & F in replacement of u/s head and handle assembly for hand pump including nut & bolts etc complete all as specified and as directed.
S & F in replacement of u/s plunger rod for hand pump complete all as specified.
S & F in replacement of u/s upper & lower valves for hand pump complete all as specified.
S & F in replacement of galvanised steel water tubing medium grade 15 mm bore ISI marked with all fittings such as bends, elbow, socket etc laid under floors/trenches or on walls with fixing arrangments including leakage testing including taking out unserviceable pipe complete all as specified and directed. Make - Tata/BST/Jindal/Prakash Surya
Description all as per item No 139 here in before but of size 20 mm bore
Description all as per item No 139 here in before but of size 25 mm bore
Description all as per item No 139 here in before but of size 32 mm bore
Description as per item No 139 here in before but of size 50 mm bore
M&L for dismentling and taking out GI water pipes with fittings and connections from wall/roof/floor or trench of size 15 mm dia including cleaning for refixing /relaying or rerouting of serviceable length complete all as specified and directed. Note:- (i) Necessary excavation refilling removing of soil shall be measured & paid separatly under relevant items. (ii) Relaying/rerouting of serviceable length of pipe will be measured and paid under seperate items here under .
Discription all as per item No 144 here in before but of size 20 mm bore
Discription all as per item No 144 here in before but of size 25 mm bore
Discription all as per item No 144 here in before but of size 32 mm bore
Discription all as per item No 144 here in before but of size 50 mm bore
M & L for cutting and removing unwanted grass, wild growth incl bushes and shrubs from the roots below ground level at various over head tanks premises about 15 mtr radious with approaching road and removing boulders from a depth not more than 25 cms below normal ground level and depositing where directed and levelling / pruning the entire cleaned area to even finish complete all as specified and directed at site.
M & L for in replacement cable, PVC insulated and sheathed, single core, 50 sqmm, multistranded copper conductor, 1100 volt grade, heavy duty IS-694 etc complete all as specified and directed.
M & L for in replacement cable, PVC insulated and sheathed, single core, 25 sqmm, multistranded copper conductor, 1100 volt grade, heavy duty IS-694 etc complete all as specified and directed.
M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc) all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
S & F chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc.
S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia.
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed.
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed. Note - Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles/ mass concrete at substations all as specified .
ROHIT ENTERPRISES
M/s Ravi Traders
m/s bobby enterprises
M/S Ritu Tandon
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .