Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | ₹17.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹19.2 L+₹1.7 L (10.0%)Rejected-AOC | ₹19.2 L+₹1.7 L (10.0%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹20.5 L+₹3.0 L (17.1%)Rejected-AOC | ₹20.5 L+₹3.0 L (17.1%) | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
10 Dec 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS MAINT OF CEILING FANS EXHAUST FANS GEYSERS SPLIT WINDOW TYPE AIR CONDITIONERS WATER COOLERS DEEP FREEZER AND ALLIED WORKS UNDER GE NORTH BANGALORE
2020_MES_393781_1
8483
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANGALORE
Class E b(i) and c(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹30,000
Yes
31 Dec 2020
9 Nov 2020
11 Dec 2020
9 Nov 2020
10 Dec 2020
23 Nov 2020
9 Nov 2020 - 21 Nov 2020
Amount
Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling and reinstallation on the at the same location including hydraulic pressure testing of container with hand operated hydraulic pump complete after necessary repair / replacement of old parts, brazing inner tank complete all as specified and as directed. NOTE:- Replacement of old parts shall be measured and paid separately.
Supply only stainless / Mild steel inner tank suitable for 25 ltrs capacity geysers of any type complete with all fittings and fixtures all as specified and as directed.
Supply only copper inner tank suitable for 25 ltrs capacity geysers of any type complete with all fittings and fixtures all as specified and as directed.
Supply only stainless / Mild steel inner tank suitable for 50 ltrs capacity geysers of any type complete with all fittings and fixtures all as specified and as directed.
Supply only copper inner tank suitable for 50 ltrs capacity geysers of any type complete with all fittings and fixtures all as specified and as directed.
Supply only heating element of 2 KW rating triangular/round type including rubber washers all as specified and as directed.
Supply only heating element of 2 KW rating hexagonal / spiral type all as per existing size and type including rubber washers all as specified and as directed.
Supply only thermostat suitable for 25/50 Ltrs capacity Geyser all as specified and as directed
Supply only Indicator lamp red and green type square/round suitable for 25/50 Ltrs capacity Geyser all as specified and as directed
Supply only safety valve/high pressure valve ISI marked suitable for 25/50 Ltrs capacity Geyser all as specified and as directed
PVC insulated copper cable flexible 3 core of size 2.5 sq.mm ISI marked complete all as specified and as directed.
Supply only outer cover suitable for geysers of 25 ltrs capacity complete with all fittings and fixtures all as specified and as directed.
Supply only outer cover suitable for geysers of 50 ltrs capacity complete with all fittings and fixtures all as specified and as directed.
Supply only PVC flexible pipe (set of two) 16mm dia 450mm long with 2 Nos of brass ferrule and rubber washers for hot and cold water all as specified and as directed.
Preparation of old painted surfaces of the geyser of any type and capacity complete after cleaning and applying one coat of spray paint(DUCO) of same shade with synthetic enamel paint, writing MES No with approved stencil including taking down and refixing in the same or other location complete all as specified and as directed.
Taking down ceiling fan 1200mm/1400mm sweep and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint(DUCO) including writing MES No with approved stencil and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Inspection, disconnecting electric connections and dismantling ceiling fan / exhaust fan /wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tightening of nuts and bolts and refixing on the the same complete after necessary repair/replacement of old parts all as specified and as directed. NOTE :- Replacement of old parts shall be measured and paid separately.
Supply only ball bearing of various sizes / make as required for ceiling fans/exhaust fan including greasing complete all as specified and as directed.
Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust fans complete all as specified and as directed.
Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust fans complete all as specified and as directed.
PVC flexible cable twin twisted core of 23 / 0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust fans complete all as specified and as directed.
Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling / opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling / opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Taking down exhaust fans 230mm / 300mm / 450mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint(DUCO) including writing MES No with pproved stencil and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Dismantling /opening the exhaust fan of 230mm /300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. NOTE FOR Sl ITEM NO. 1.24 to 1.26, 1.28 & 1.29 :- Cost of spares will be measured and paid separately under relevent items.
Extension of down rod suitable for ceiling fans height upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
PVC fresh air fan of 150mm sweep, 1200/1400 RPM with louvers all as per Havells Cat No. Ventil Air DXWT or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable and taking down the existing fan all as specified and directed.
PVC fresh air fan of 200mm sweep, 1200/1400 RPM with louvers all as per Havells Cat No.CELSO or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable and taking down the existing fan all as specified and directed.
PVC fresh air fan of 250mm sweep, 1200/1400 RPM with louvers all as per Havells Cat No. Ventil air -DX or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable and taking down the existing fan all as specified and directed.
Motor with blades suitable for exhaust fans upto 280 mm sweep of any make and type, heavy duty, 1400 RPM, AC, single phase, 230/240 Volts complete including taking down the existing all as specified and directed.
Motor with blades suitable for exhaust fans 300 mm sweep of any make and type, heavy duty, 1400 RPM, AC, single phase, 230/240 Volts complete including taking down the existing all as specified and directed.
Outer frame for holding exhaust fan motor with supporting angle suitable for existing exhaust fans up to 280 mm sweep of any make and type complete including taking down the existing frame all as specified and directed.
Outer frame for holding exhaust fan motor with supporting angle suitable for existing exhaust fans 300 mm sweep of any make and type complete including taking down the existing frame all as specified and directed.
Louvers set suitable for exhaust fans 300 mm sweep of any type and make with complete accessories including taking down the existing all as specified and as directed
Louvers set suitable for exhaust fans 450 mm sweep of any type and make with complete accessories including taking down the existing all as specified and as directed
Removing the window type AC / split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing and commissioning complete all as specified and as directed.
All as per Sl Item No.1.040 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
All as per Sl Item No.1.040 here-in-before, but for water coolers of 120 / 150 ltrs capacity.
All as per Sl Item No.1.040 here-in-before, but for refrigerators/deep freezers of 165 / 180 / 220 ltrs capactiy.
All as per Sl Item No.1.040 here-in-before, but for refrigerators/deep freezers of 286 / 310 / 320 ltrs capactiy.
Removing the split type AC 1.5 ton capacity of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, adjusting relays, thermostat etc bringing back and installing in its original position including testing and commissioning complete all as directed for the following capacities:-
All as per Sl Item No.1.045 here-in-before, but for capacity of 2.0 ton AC.
All as per Sl Item No. 1.045 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
All as per Sl Item No. 1.045 here-in-before, but for water coolers of 120 / 150 ltrs capacity.
All as per Sl Item No.1.045 here-in-before, but for refrigerators/deep freezers of 165 / 180 / 220 ltrs capactiy.
All as per Sl Item No.1.045 here-in-before, but for refrigerators/deep freezers of 286 / 310 / 320 ltrs capactiy. NOTE FOR Sl ITEM No. 1.040 to 1.050 :- (i) Gas charging will be measured and paid separately under relevent items of this schedule. (ii) Spares costing more than Rs 200 will be measured and paid seperately under relevent item of this schedule.
Labour only for charging of refrigerent gas (R-22/410A/134A) of required quantity for split/window type AC of 1.50 ton capacity including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing all as specified and as directed.
All as per Sl Item No.1.051 here-in-before, but for capacity of 2.0 ton AC.
All as per Sl Item No. 1.051 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
All as per Sl Item No.1.051 here-in-before, but for water coolers of 120 / 150 ltrs capacity.
All as per Sl Item No.1.051 here-in-before, but for refrigerators/deep freezers of 165 / 180 / 220 ltrs capactiy.
All as per Sl Item No.1.051 here-in-before, but for refrigerators/deep freezers of 286 / 310 / 320 ltrs capactiy. NOTE FOR Sl ITEM No. 1.051 to 1.056 :- (i) Cost of refrigerent Gas will be measured and paid separately under relevent items of this schedule. (ii) Spares costing more than Rs 200 will be measured and paid seperately under relevent item of this schedule.
Painting of water coolers of 40 / 80 ltrrs capacity with two coats of synthetic enamel paint of existing colour all as directed over a coat of primer after welding the base plate with MS angle iron frame of existing size removing dust, tinkering, applying metal putty wherever necessary including writing of SM/MES No all as directed by Engineer-in-Charge.
All as per Sl Item No.1.057 here-in-before, but for water coolers of 120 / 150 ltrs capacity.
Removing the unserviceable blower motor from the window type AC/Spilit type AC, removing the burnt out winding from slots, rewinding with superior quality copper winding wire of higher insulation level, varnishing, drying the motor complete and fixing in position including testing and commissioning for 1.5/2 ton capacity all as specified and as directed.
All as per Sl Item No. 1.059 here-in-before, but for water coolers of 40 /60/ 80 ltrs capacity.
All as per Sl Item No.1.059 here-in-before, but for water coolers of 120 / 150 ltrs capacity.
All as per Sl Item No.1.059 here-in-before, but for refrigerators/deep freezers of 165 / 180 / 220 ltrs capactiy.
All as per Sl Item No.1.059 here-in-before, but for refrigerators/deep freezers of 286 / 310 / 320 ltrs capactiy.
Bearings and gun metal bushes of appropriate size and testing complete suitable for water coolers of 40/80 ltr capacity fixed all as directed including taking down the existing worn out items complete all as specified and as directed.
All as per Sl Item No.1.064 here-in-before, but for water coolers of 120 / 150 ltrs capacity.
Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directed.
Removing the unserviceable thermostat, supply and fix new thermostat of same make and type suitable for Split/window type AC 1.5/2 ton capacity all as specified and as directed.
All as per Sl Item No.1.067 here-in-before, but for water Cooler 40/60/80 ltrs capacity.
All as per Sl Item No.1.067 here-in-before, but for water Cooler 120/150 ltrs capacity.
All as per Sl Item No.1.067 here-in-before, but for refrigerator 165/220 ltrs capacity.
All as per Sl Item No.1.067 here-in-before, but for refrigerator 286/310/320 ltrs capacity.
Removing the unserviceable potential relay, supply and fix relay of same make and type suitable for water cooler 40/60/80 ltrs capacity.
All as per Sl Item No.1.072 here-in-before, but for water cooler 120/150 ltrs capacity.
Removing the unserviceable condenser unit, supply and fix new condenser unit including connecting to the discharge line, brazing, vaccumising and gas charging the unit with required quantity of refrigerant for water cooler upto 120/150 Ltrs capacity and testing complete all as directed.
Removing the unserviceable condenser unit, supply and fix new condenser unit including connecting to the discharge line, brazing, vaccumising and gas charging the unit with required quantity of refrigerant for refrigerator / deep freezer 165/175/286/310/320 Ltrs capacity and testing complete all as directed.
Removing the unserviceable condenser unit, supply and fix new condenser unit including connecting to the discharge line, brazing, vaccumising and gas charging the unit with required quantity of refrigerant for split/window type AC of 1.5/2 Ton capacity and testing complete all as directed.
Removing the unserviceable potential relay from the refrigerator / deep freezers of 165 / 175 / 220 ltrs capacity, supply and fix new relay of same make and type complete all as specified and as directed.
All as per Sl Item No.1.077 here-in-before, but for 286/310/320 ltrs capacity.
Removing / dismantling unserviceable evaporator freezer box unit including door cover, providing new unit including connecting the refrigerant pipe lines, peak testing, vacumising and gas charging the unit with required quantity of refrigerant gas suitable for refrigerator of 286/310 ltrs capacity and testing complete all as directed.
All as per Sl Item No 1.079 here-in-before, but for refrigerator of 165/175/220 ltrs capacity.
Removing the damaged/ unserviceable refrigerator/Deep freezer magnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper seating of the door for 165 / 175 / 220 ltrs capacity.
All as per Sl Item No 1.081 here-in-before, but for 286 / 310 / 320 ltrs capaciy all as directed.
Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitor suitable for 1.5 ton AC of any type and make as existing complete all as specified and as directed.
All as per Sl Item No.1.083 herein before, but starting capacitor of 80/100 MFD suitable for 1.5 TR /2 TR AC.
All as per Sl Item No.1.083 herein before, but starting capacitor of 60/80 MFD for water cooler.
Removing the unservicable over load protection, supply and fix new over load protector suitable for split/window type AC of 1.5/2.0 TR capacity.
Removing the unservicable push cock of any type from water cooler, supply and fix new stainless steel metal push cock 15mm di of same type complete all as specified and as directed.
Removing the unservicable PVC ball valve 15mm dia including float and replace with new PVC ball valve of 15mm dia suitable for water coolers of any make and size all as specified and directed.
Removing the unservicable PVC flexible pipe, supply and fix new PVC flexible pipe of existing type size for water outlet of water cooler all as specified and as directed.
Disconnecting and removing the damaged unservicable supply cord for cooling appliances, supply and fix new PVC insulated 3 core 2.5 sq.mm multi stranded copper conductor cable complete all as specified directed.
Disconnecting and remove the burnt / damaged switch socket combination 3 pin 15 Amps, supply and fix MCB enclosure industrial type single pole and neutral with two pin and earth plug and socket with MCB SP of 20 Amp capacit complete all as specified and as directed.
Supply only refrigrent gas (R-22/410A/134A) for domestic cooling appliances complete all as specified and as directed.
Disconnecting and taking out the unservicable sensor / remote unit completely, supply and fix new sensor / remote unit of indoor unit of AC suitable for 1.5 Ton split type AC of any type and make complete all as specified and as directed.
All as per Sl Item No.1.093 herein before, but for 2 ton capacity split type AC.
Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC 1.5 ton capacity of any type and any make all as specified and as directed.
All as per Sl Item No.1.095 herein before, but for 2 ton Split type AC.
Disconnecting and taking PCB circuit by disconnecting out PCB from split AC of 1.5 / 2 ton capacity, repairing the same and refixing in original location complete all as specified and as directed.
Disconnecting electrical connections, removing copper line, discharge line of split type AC up to 2 Ton capacity including indoor, out door units with all accessories and shifting / reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
Plastic / coir filter suitable for split / window type AC 1.5 / 2 ton capacity including taking down old un serviceable filter etc., complete all as specified and as directed.
Removing the unservicable voltage stabilizerof 1 KVA capacity from position, open the outer covers, removing the burnt out winding of existing transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly including replacement of boost buck relays, assembling the stabilizer complete and fixing back in original position, testing and commissioning complete all as specified and as directed.
All as per Sl Item No.1.100 herein before, but for 2/3 KVA capacity.
All as per Sl Item No.1.100 herein before, but for 5 KVA capacity.
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including PVC casing and caping ISI marked including accessories surface type wiring with MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed mounted/ on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 1.104 here in before but one fan point controlled by one switch/regulator.
All as per Sl Item No. 1.104 here in before but one light point controlled by 2 way switch.
All as per Sl Item No. 1.104 here in before but one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 1.104 here in before but one bell / buzzer point controlled by bell push.
All as per Sl Item No. 1.104 here in before but one 3 pin socket out let 5 Amps on same board
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including PVC casing and caping ISI marked including accessories surface type run on walls/ ceiling with MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through existing PVC conduit including accessories concealed type wiring with MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed mounted/ on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 1.111 here in before but one fan point controlled by one switch/regulator.
All as per Sl Item No. 1.111 here in before but one light point controlled by 2 way switch.
All as per Sl Item No. 1.111 here in before but one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 1.111 here in before but one bell / buzzer point controlled by bell push.
All as per Sl Item No. 1.111 here in before but one 3 pin socket out let 5 Amps on same board.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted / concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Sub main wiring complete with two runs of 4 sq.mm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sq.mm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed.
Concealed point wiring by using 1.5 sq.mm PVC insulated unsheathed FRLS copper conductor multi stranded drawn in suitable sunken box and frame cover plate for mounting of modular switches /sockets as required at site and provn of PVC rigid non metallic conduit medium density ISI marked fixed with all fittings and accessories for mounting of switches and socket complete for one light / fan / socket point controlled by one switch including MS sunken boxes, cover frame and provn of 1.5 sq.mm PVC insulated copper conductor contineous as earth wire connected to earth dolly complete all as specified and directed for one light point controlled by one switch.
All as per Sl Item No. 1.119 here in before but one fan point controlled by one switch/regulator.
All as per Sl Item No. 1.119 here in before but one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 1.119 here in before but one 3 pin socket out let 5 Amps on same board
All as per Sl Item No. 1.119 here in before but one bell / buzzer point controlled by bell push.
All as per Sl Item No. 1.119 here-in-before but for 16 Amps socket outlet by using 2.5 sq.mm PVC insulated unsheathed copper conductor multi stranded on independent board including provn of 2.5 sq.mm PVC insulated solid copper conductor contineous as earth wire. NOTE FOR SL ITEM NO:-1.104 to 1.124 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten fittings, 18 watts, 6000K, (4 feet long), suitable for indoor applications wall mounted with extruded aluminium heat shink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, with bipin holders, connector block , lamp etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLAB 18 WH LED P / Halonix Cat No. HLB-03-18-CW-AL or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable all as specified and directed.
LED tube light fittings, 10 watts, 6000K, (2 feet long), wall mounted with extruded aluminium heat sink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, with bipin holders,connector block, lamp etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLSB 10 WH / Halonix Cat No. HLB-03-10-CW-AL or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable all as specified and directed.
Surface mounted LED Luminaire of size 1' x 1' 18 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No : BZSSQL 18W WH or techno commercially equivalent makes specified in PS including connecting up with suitable size of twin core twisted flexible copper conductor cable all as specified and directed.
LED lamp suitable to fit in angle holder of capacity 09 watt including taking down the existing complete all as specifed and directed.
Modular type switch 6 Amps, one way including taking down the existing switch complete all as specified and directed.
Modular type switch 16 Amps, including taking down the existing switch complete all as specified and directed.
Modular type Socket outlet, 6 Amps, including taking down the existing socket outlet complete all as specifiedand directed.
Modular type Socket outlet, 6/16 Amps, including taking down the existing socket outlet complete all as specifiedand directed.
Modular fan regulator electronic step type including taking down the existing regulator complete all as specifed and directed.
Modular bell push flush type 5 Amps, one way including taking down the existing switch complete all as specified and directed.
Switch Piano flush button single pole two way 5 Amps including taking down the existing switch all as specified and as directed.
Angle holder PVC / polycarbonate type including taking down the existing holder all as specified and as directed.
Switch Piano flush type single pole one way 5 Amps including taking down the existing switch all as specified and as directed.
Switch socket outlet combination 5 pin, 2 in 1, 5 Amps flush type including taking down the existing socket outlet complete all as specified and as directed.
Switch socket combination, 2 in 1, 5 pin, 5 and 15 Amps flush type universal type including taking down the existing socket out let all as specified and as directed.
Socket outlet 2 in 1, 5 pin 5 Amps including taking down the existing socket all as specified and as directed.
Bell push flush type 5 Amps, including taking down the existing bell push all as specified and as directed.
MCB SPN 240 volts 40 Amps including taking down the existing MCB complete all as specified and as directed.
MCB single pole 240 volts 6 to 32 Amps including taking down the existing MCB complete all as specified and as directed.
MCB TPN 415 volts , 63 Amps including taking down the existing MCB complete all as specified and as directed.
MCB DB SPN, 4 way, double door type, 240 volts with 200 Amps rated busbar including taking down the existing MCB DB all as specified and as directed.
MCB DB SPN, 8 way, double door type, 240 volts with 200 Amps rated busbar including taking down the existing MCB DB all as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated bus bar for housing MCBs including taking down the existing MCB DB all as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals including taking down the existing eiling rose all as specified and as directed.
Electronic fan regulator flush and stepped typetype including taking down the existing regulator all as specified and as directed.
Ding Dong bell, AC, 230 volts single pole including taking down the existing bell all as specified and as directed.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
LED building security light fitting 30 Watt with pressure die cast housing, with secondary optics and IP 65 protection all as per Bajaj, Cat No.BCLST 30W LED I or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable all as specified and directed.
Brackets made out of GI tubing medium grade 40mm bore of 1.50 mtr length bent to required shape and pattern to mount the street light, including MS clamps made out of MS flat iron 25 x 6mm, nuts, bolts, washers etc and applying two coats of alumium paint over a coat of red oxide primer including removing the old existing GI bracket from building complete all as specified and directed.
Single pole and neutral enclosure 20 Amps, 240 Volts with two pin and earth plug and socket complete with one single pole MCB 20Amps including taking down the existing complete all as specified and as directed.
Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof / wall conductors and down conductors above ground including taking down the existing complete all as specified and as directed.
Fixing only in repairs Aluminium strip 25 x 3mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, as required with saddles and screws, complete all as specified and as directed.
MCCB 3 pole, 415 volts, 100 Amps, 16 KA complete including taking down the existing complete all as specified and as directed.
Recess mounted LED Luminaire 2' x 2' 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No : BZRSQL 36W GZi WH or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable all as specified and directed.
LED luminaries, round 18 watt PERARL + LED Slim surface panel mounted type suitable for indoor application, complete with all accessories all as per Crompton Greaves Cat part No: LCDSPLN-R-18-CDL or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable including taking down the existing all as specified and directed.all as specified and directed.
SREE VARU ELECTRICALS
Auromirra Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .