Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.0 L+₹2.3 L (11.2%)Rejected-AOC 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹24.8 L+₹4.1 L (19.9%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹26.8 L+₹6.1 L (29.4%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹31.3 L+₹10.7 L (51.5%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services
REPAIR / MAINTENANCE OF LT OH/UG CIRCUIT AND WITCHGEARS, PANEL BOARD AND CONNECTED ACCESSORIES AT ZONE-II AREA UNDER GE(S) JAIPUR IN MIL STN JAIPUR
2023_MES_624204_1
GE(S) J-35 P OF 2023-24 8839 / E8
Open Tender
Civil Works
Item Rate
300 days
Jaipur
Class E Category b(i)
9 documents required · 9 mandatory
₹500
GE(S) Jaipur
₹50,000
Yes
8 Feb 2024
19 Oct 2023
24 Nov 2023
19 Oct 2023
16 Nov 2023
3 Nov 2023
Amount
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point
M & L Sand cushioning to under ground cable with stone crushed sand and punning to provide a required cover.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C2 with 40 mm stone aggregate for base / foundation / earthing chamber / chamber cover including form work complete all as directed by EIC
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete.
Dismantling of existing Unsv ACSR conductor of any size from insulators fixed on poles as directed by Engineer-in-Charge.
Dismantling of prestressed cement concrete poles complete of any size including PCC foundation and necessary excavation & earth work and making good to distubed surfaces as directed by Engineer-in-Charge
Dismantling and taking down existing LT insulators of any type and size as directed by Engineer-in-Charge.
Dismantling of existing stay assembly of any type & size complete including excavation and earth work and demolition of concrete and making good to disturbed surfaces as directed by Engineer-in-Charge
Dismantling of cross arms, bracing, supports, clamps, nuts and bolts of mild steel channel or angle sections etc complete as directed by Engineer-in-Charge
Dismantling/taking out old defective LT UG cable from trench/ on walls/poles/ducts etc of 25 sqmm, 4 core to 50 sqmm, 3.5 core.
-ditto- but of 70 Sqmm, 3.5 core to 95 Sqmm 3.5 core
-ditto- but of 120 Sqmm 3.5 core to 400 Sqmm 3.5 core
Supply, fixing & install Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.0 metres long complete all as specified.
M&L stay assembly complete with accessories as shown in electrical plate No. 1 of MES SSR part I, including stay rod of 20 mm dia, MS stay plate 300 mmx500mmx6mm & GI stay wire of 7/8 SWG, bow, PCC 1:3:6 of suitable length as required.
M&L pin type, porcelain, vitreous brown, white or green insulator 100 mm height and 65 mm dia, 1100 volts grade including one galvanised MS spindle, two GI washers and one GI nut complete conforming to IS.
M&L shackle type, porcelain, vitreous, brown, white or green insulator 1100 volts grade of 90 mm dia and 75 mm height including galvanised MS strap of 31 mm x 3 mm size, 12 mm dia insulator bolts, washers and nuts, complete, conforming to IS.
M&L for aluminium conductor steel reinforced (ACSR) straining properly on insulator and binding with aluminium binding/ Clamps, for running lines or jumpers etc.of any type and sizes complete all as specified and directed by Engineer-in-charge. Note:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
Straining only existing ACSR of any size/span on existing poles, insulators using proper tensioners and binding with aluminium binding/ Clamps complete as directed by Engineer-in-Charge. (each length of single conductor measured separately) Note:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints etc.
Supply and lay tube GI light grade of 40 mm bore in trenches/ road crossings/ floor/poles/walls etc. with all fittings for protection of cable
-ditto- but 50 mm
-ditto- but 80 mm
Labour for boring under road/drain by manual/machine method for inserting GI tubing up to 80 mm dia for cable protection all as specified and directed by EIC.
M&L earthing complete as per electrical plate No. 5 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sidesNOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire/strip. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Supply, laying, connecting, and commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strip armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc of size 120 Sqmm, 3.5 Core.
-ditto- but 95 Sqmm, 3.5 Core
-ditto- but 70 Sqmm, 3.5 Core
-ditto- but 50 Sqmm, 3.5 Core
-ditto- but 35 Sqmm, 3.5 Core
-ditto- but 25 Sqmm, 4 Core
-ditto- but 185 Sqmm, 3.5 Core
-ditto- but 240 Sqmm, 3.5 Core
-ditto- but 400 Sqmm, 3.5 Core
Scrapping & preparation of old steel surface of LT Panel of any type and M&L for painting the same with two coats of synthetic enamel paint by spray of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fix heat shrinkable straight through jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of size 10 - 35 Sqmm 3.5 Core
-ditto- but 50 - 70 Sqmm 3.5 Core
-ditto- but 95 - 150 Sqmm 3.5 Core
-ditto- but 185 Sqmm 3.5 Core
-ditto- but 400 Sqmm 3.5 Core
Supply and fix heat shrinkable end jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of size 10 - 35 Sqmm 3.5 Core
-ditto- but 50 - 70 Sqmm 3.5 Core
-ditto- but 95 - 150 Sqmm 3.5 Core
-ditto- but 185 Sqmm 3.5 Core
-ditto- but 400 Sqmm 3.5 Core
Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB 63 amp, 27 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase, adjustable type including extension terminals and Ics=100%Icu connecting using suitable fasteners, modification/fabrication if any complete all as required at site, as specified and directed.
-ditto- but 100 amp, 27 KA
-ditto- but 125 amp, 27 KA
-ditto- but 160 amp, 36 KA
-ditto- but 200 amp, 36 KA
-ditto- but 250 amp, 36 KA
-ditto- but 400 amp, 50 KA
S&F of Danger notice plate of 1.6 mm thick mild steel sheet 20x15 cm size, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with suitable MS clamps, bolts and nuts including taking down complete all as specified and directed.
Disconnecting & taking out the existing Unserviceable LT panel and S&F new out door (Kiosk type) type LT panel, weather & vermin proof MS sheet housing 3.15 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 200 Amp, 35/36 KA, 415 volts, thermal release, adjustable type (Ics=100%Icu) as incomer and provision of 2 outgoing MCCBs, 4 pole, 415 Volts, 200 Amps & copper bus bar 400 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and directed by Engr-in-charge.
Supply, installation and testing of LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 5mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer complete mounted on angle iron 40mm x 40mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following. (a) Copper Bus bar :-Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB ,as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 250 amps rating and 36 KA rupturing capacity,adjustable thermal and fixed magnetic type( Ics=100%Icu) - 03 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 200 amps rating and 27 KA rupturing capacity,adjustable thermal and fixed magnetic type (Ics=100%Icu).. -02 Nos. Note:-(i) All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (iii) Panels shall be placed above 0.6 mtr from ground level (iv) Outgoing Cables shall be fed with solid busbar connectors.
Supply, installation and testing of LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 5mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer complete mounted on angle iron 40mm x 40mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following.
(a) Copper Bus bar :-Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB ,as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.
(c) Outgoing :- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 160 amps rating and 27 KA rupturing capacity,adjustable thermal and fixed magnetic type( Ics=100%Icu) - 04 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 100 amps rating and 27 KA rupturing capacity,adjustable thermal and fixed magnetic type( Ics=100%Icu).. -03 Nos. Note:-(i) All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (iii) Panels shall be placed above 0.6 mtr from ground level
S&F in repair LED indicating lamp (Set of three lamps, RYB), 240 volts AC including necessary wiring
S&F in repair Red luminous push button complete all as specified and directed by Engr in Charge.
S&F in repair Green luminous push button complete all as specified and directed by Engr in Charge.
M&L for cutting/removing damaged Hinge of any size and welding/ fabricating same with best quality replacement spare in the existing panel including making good of existing surface
M&L for fault finding in U/G cable using fault locating machine on requirement for LT/HT cables of any type/size complete all as specified and directed by Engr-in charge.
S&F cable route indicator, cast iron 10 cm dia with 25x25x4 mm angle iron 0.8 m along the LT/HT cable trench including painting and grouting in ground in PCC 1:2:4 type B1 using 20 mm graded aggregate complete all as specified and directed by Engr in Charge.
M&L for shifting of LT Panel from one location (within the electrical zone) to another location including making all electrical connections as well as PCC foundation completely as specified and directed by Engr-in-Charge. Note:-Excavation & related earth work shall be inclusive of quoted rates.
S&F RCBO TPN 40 Amps,300 mA,4 module, 240/415 volts complete all as specified and directed by Engr in Charge.
Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m all as directed by Engineer-in-Charge.
Shree Karni Electrovision
SHREE BHAGWATI ENTERPRISES
Nvimal Engineers and Contractor
LAKSHMI ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .