| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹43.2 L+₹4.5 L (11.7%)Rejected-Finance NADUA GAON POST NADUA DIKOM DIST DIBRUGARH ASSAM 786 101 | DIBRUGARH | DIBRUGARH | ASSAM | 786101 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹44.1 L+₹5.4 L (14.0%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹45.7 L+₹7.0 L (18.0%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹45.9 L+₹7.2 L (18.7%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
15 Oct 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
AUGMENTATION OF EXISTING PERIMETER SECURITY LIGHT AT OUTPOCKET AND CERTAIN REVENUE AND MINOR WORKS UNDER GE DINIAN
2022_MES_552656_1
C/8486/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹78,000
Yes
23 Nov 2022
17 Sept 2022
17 Oct 2022
17 Sept 2022
15 Oct 2022
1 Oct 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, or for shafts, wells, cesspits, manholes, pier holes, or laying of cables, poles, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m and not exceeding 3 m in depth for foundation, or for shafts, wells, cesspits, manholes, pier holes, or laying of cables, poles, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
M&L for hardcore of brocken bricks or boulder, of gauge not exceeding 63 mm, deposited, spread, and leveled in layers not exceeding 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed.
M&L for PCC (1:4:8), type D2 (using 40mm graded broken stone aggregate) as in foundations, filling and mass concrete, pole etc complete all as specified and as directed.
M&L for PCC (1:3:6), type C2 (using 20mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC (1:3:6), type C2 (using 40mm graded broken stone aggregate) as in surface channels and drains etc complete all as specified and as directed.
M&L for PCC (1:3:6), type C1 (using 40mm graded broken stone aggregate) as in coping of poles and stay including necessary form work etc complete all as specified and as directed.
M&L for PCC (1:2:4), type B0 (using 12.5mm graded stone aggregate) as in 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and as directed.
M&L for precast cement concrete as in manhole cover slab, type B1 (1:2:4), (using 20mm graded stone aggregate) set in cement mortar (1:4) complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in chajja etc complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) in column, pillar, piers, post and struts complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surface of concrete complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping), rough finished flat surface of concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 08 mm and over for stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. .
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, in one brick thick honey comb walling, built in cement mortar (1:4) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of external wall of brick work or concrete surfaces in cement mortar (1:4) including finished the surface even and fair complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar(1:4) using water proofing compound in top layer (water proofing compound measured separately) and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick of internal wall on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on ceiling in cement mortar (1:3) finished even & smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for 40 mm thick damp proof course to horizontal or vertical surface including necessary formwork in cement mortar (1:2:4) type B-0 complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8), type D2, (using 40mm graded broken stone aggregate) as in sub base of floor etc complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4), type B0, (using 12.5mm graded broken stone aggregate) as in sub base of surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 450X 350X 7 mm thick over 10 mm thick back coat of cement mortar (1:4) set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered surface of ceiling etc and applying three coats of white wash complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified in SSR Part-1 complete all as specified and as directed.
S&F for 20 mm bore dia of pipe, Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20 mm - 210 gms) complete all as specified and as directed.
S&F for anodised aluminium windows/ventilator sliding shutter, three track way type without sash bars, alumimium sections weighing 0.55 Kg/m including necessary joining cleats, glass clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings, such as peg stays, 150mm long (1 No) hinges type B-21, 100mm long (2 Nos) suitable handle, with complete accessories including glass, wire mesh, anodised aluminium frame (chowkhat) complete all as specified and as directed.
S&F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed
S&F for factory made solid panel PVC door shutter, 30 mm thick (style) consisting of frame, made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR Part II 2010 complete all as specified and as directed
S&F for 100mm long butt hinges, medium weight, cold rolled mild steel fixed to chowkats complete all as specified and as directed.
S&F for aluminium handle 100 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
S&F for 100 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and laying of 16mm of CPVC pipes SDR 11& plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. tranches complete all as specified and as directed.
Supply and laying of 20mm of CPVC pipes SDR 11& plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. tranches complete all as specified and as directed.
S&F for 16mm outer dia, CPVC Brass thread elbow complete all as specified and as directed.
S&F for 20mm outer dia, CPVC Brass thread elbow complete all as specified and as directed.
S&F for 16mm outer dia, CPVC Brass thread Tee complete all as specified and as directed.
S&F for 20mm outer dia, CPVC Brass thread Tee complete all as specified and as directed.
S&F for 16mm outer dia, CPVC Brass thread union complete all as specified and as directed.
S&F for 20mm outer dia, CPVC Brass thread union complete all as specified and as directed.
S&F for 16mm outer dia, CPVC ball valve complete all as specified and as directed.
S&F for 20mm outer dia, CPVC ball valve complete all as specified and as directed.
S&F for 25mm outer dia, CPVC ball valve complete all as specified and as directed.
S&F for 25mm outer dia, CPVC tank adopter complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
M&L for PVC (SWR) floor trap, 75mm dia, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and as directed.
M&L for PVC (SWR) gully trap, 125/110 mm dia, setting and jointing with solvent cement complete all as specified and as directed.
S&F in repairs 32 mm waste coupling of PTMT (half or full threaded) (Minimum weight 32mm?45gms/40mm-60 gms)complete all as specified and as directed.
S&F for 15 mm bore dia bib taps, chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for 15 mm bore dia pillar taps, chromium plated, cast copper alloy, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F 15 mm bore dia stop valves (concealed type), fancy type, chromium plated cast copper alloy with long shank, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for PVC connections 15mm size with PTMT nuts of length 600 mm long complete all as specified and as directed.
S&F for tubular towel rail, 20mm dia, D-type, 60cm long brass chromium plated between flanges complete all as specified and as directed.
S&F for PVC low level flushing cistern, 10 liter capacity, valveless, symphonic action type with inlet, ball valve, float and handle including bracket, PVC connection pipe and flush pipe of polyethylene of low or high density complete all as specified and as directed.
S&F in repair vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand (exclusive of fixing of supply and waste pipe) complete all as specified and as directed.
S&F for vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor using concrete (1:2:4) type B0 and to match with existing specifications complete all as specified and as directed. Make : Cat No. C0117 of Parryware/Hindware/Cera.
S&F for vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a)Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4(12.5 mm graded aggregate) finished even and smooth. (c) M&L for 15 mm thick cement mortar in 1:4 finished even and smooth. (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sum conforming IS-3384. (f) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sum reinforced with polyster non woven fabric (weighing not less than 160 gms/sum) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (g) One coat of aluminium paint over APP membrane @0.11Kg/Sqm. Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
Cutting the existing 50/40 mm bore GI pipe line and making necessary arrangement for taping of new pipe line of 40mm dia including threading, welding and all required accessories complete all as specified and as directed.
M&L for valve pit and construction of brick masonry valve pit of internal dimension 40 x 40 x 40 cm depth with sub class 'B' bricks in CM (1:6) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:2:4) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 5 mm angle iron and 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and as directed.
S&F 25 mm bore, gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and as directed.
S&F 40 mm bore, gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and as directed.
S&F for 25mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to laid in trenches etc complete all as specified and as directed.
S&F for 40mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to laid in trenches etc complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 sqmm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metallic PVC rigid conduit medium grade of 20mm dia and conduit accessories and fittings like bend, elbows, crosses wall crossing etc. including cutting, chasing and pinning fixed on wall, floor, roof and including provision of PVC insulated FRLSH 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet, fan regulator etc, including testing on completion for one light/ fan point/ bell buzzer point controlled by one way 6 Amp modular switch complete all as specified and as directed. Note : Cost of PVC conduit, cover plate and box of suitable module, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortar (1:4), matching with existing colour/paint of surface are deemed to be included in the quoted rate.
All as per item No 94 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No 94 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches.
All as per item No. 94 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 3 pin socket outlet, 5/15 Amps on Independent board complete all as specified and as directed..
S&F for switch piano, 5 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, flush type bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase /PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair LED bulb of 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj.
S&F for factory made board distribution (DB), double door in steel sheet enclosure with 200 amps rated common bus bar at incoming end, SPN, 4 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed. Make : Cat No : DHDPSHODRW04 of Havells or equivalent.
S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. TSPC6-32 of HPL or equivalent.
S&F for MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No TSPNC6-32 of HPL or equivalent.
S&F for 20 Watt, surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton/Century.
S&F for 10 Watt, LED, energy saving new generation bulk head luminaire with opal diffuser including lamp incl connecting with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton/Century.
S&F for 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 complete all as specified and as directed. Make : Cat No. ENDURAPEARLLS25WSASYTOPC of Havells/Philips/Bajaj/Crompton/Century.
Supply, installing, testing and commissioning of light duty metal anti dust exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 31 W, 220/240 V, 225 to 230 mm sweep size, fan speed 1380 RPM, 3 nos. blades, copper winding, Air delivery minimum 800 CMM and including all fixing accessories complete all as specified and as directed. Make : Model No Tarns Air 12" - reversible of Cropmpton/Bajaj/Khaitan/Havells/Orient.
M&L for making hole for insertion of exhaust fan 300 mm sweep & cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with existing colour/paint of surface area complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4mm GI wire by means of bolts and nuts checknuts and washers protected by 20mm bore galvanised iron light grade pipe, funnel with 40mm bore GI medium grade pipe for watering, wire mesh including concrete pit PCC 1:3:6 type C1, precast RCC 1:2:4 type B1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 150 mm center to center in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, including necessary excavation and earth work in any type of soil, all as specified and shown in electrical plate no 3 of SSR part-1 complete all as specified and directed and tested on completion.
S&F for bus bar junction box suitable size but not less than 50 x 50 x 30 mm for cable termination including 63 Amps 4 pole MCCB incommer with 04 Nos aluminium bus bar of rating 100 Amps and incoming fuse and indicator system complete all as specified and as directed. Note : Cost of MCCB, busbar, PCC, cable lugs earth work shall be deemed to be included in the unit rate.
S&F for bus bar junction box suitable size but not less than 50 x 50 x 30 mm for cable termination including 32 Amps 4 pole MCCB incommer with 04 Nos aluminium bus bar of rating 63 Amps and incoming fuse and indicator system complete all as specified and as directed. Note : Cost of MCCB, busbar, PCC, cable lugs earth work shall be deemed to be included in the unit rate.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 mtr long) including painting (aluminium paint) and writing pole serial number using paint in white colour on black background including taking down old unserviceable complete all as specified and as directed. Note : Earth work shall be measured and paid separately.
S&F in repair 100 Watt LED street light made of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics PC with IP66 protection and impact resistance of IK07 protection complete including 2.5 Sqmm multistranded aluminium conductor cable with suitable length fixed to pole etc on complete all as specified and as directed. Make : Cat No. Endura city liner Neo, ENDURAPEARLMAGNUMSL100WLED757PASYTOTGAST of Havells/ Philips/ Bajaj/ Crompton/ Century.
S&F in repair 90 Watt LED street light made of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics PC with IP66 protection and impact resistance of IK07 protection complete including 2.5 Sqmm multistranded aluminium conductor cable with suitable length fixed to pole etc on complete all as specified and as directed. Make : CatNo. Endura city liner Neo, ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO of Havells/ Philips/ Bajaj/ Crompton/ Century.
S&F in repair 70/75 Watt LED street light made of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics PC with IP66 protection and impact resistance of IK07 protection complete including 2.5 Sqmm multistranded aluminium conductor cable with suitable length fixed to pole etc on complete all as specified and as directed. Make : Cat No. Endura city liner Neo, ENDURAPEARLNEOSL75WLED757PASYTOPC of Havells/ Philips/ Bajaj/ Crompton/ Century.
S&F in repair 60 Watt LED street light made of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics PC with IP66 protection and impact resistance of IK07 protection complete including 2.5 Sqmm multistranded aluminium conductor cable with suitable length fixed to pole etc on complete all as specified and as directed. Make: Havells , Cat Pt No. Endura city liner Neo, ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent make of jaguar/ CG/ Century LED Ltd.
S&F in repair 40/45 Watt LED street light made of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics PC with IP66 protection and impact resistance of IK07 protection complete including 2.5 Sqmm multistranded aluminium conductor cable with suitable length fixed to pole etc on complete all as specified and as directed. Make : Cat No. Endura city liner Neo, ENDURAPEARLNEOSL40WLED757PASYTOPC of Havells/ Philips/ Bajaj/ Crompton/ Century.
S&F in repairs integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 100W LED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed. Note : Warranty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor.
S&F in repair 50/45 Watt LED post top made of pressure die cast aluminium spigot housing with decorative opal diffuser and IP65 protection, including providing and connection with 1.5 Sqmm copper conductor, multistranded copper conductor cable with suitable length complete all as specified and as directed. Make : Cat Pt No. RUBYMAXIPT50WLED757PASYMTOPC of Havells/ Philips/ Bajaj/ Crompton/ Century.
S&F in repairs street light bracket arm of length not less than 1.2 m made out of GI tubing, 25 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed.
S&F in repairs modular junction box made of SMC/FRP of size 250x250x155mm with provision of MCB SPN 6A, and connector terminal bus bar 4 pole indicating RYB phase colour and neutral colour complete fixed to street light pole with suitable size of mild steel/ flat iron clamps, nuts and bolts complete all as specified and as directed. Make : Cat No. GSJB 2525 of Sintex /Hensel.
S&F in repair 25mm dia, rigid non metallic, PVC conduits, ''medium grade" complete with all accessories suitable for UG cable complete all as specified and as directed.
S&F for time switches digital type 250 Volt single phase of 20 Amp rating with contactor fitted inside steel enclosure complete including connecting items complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including taking out old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core including taking out old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable LTUG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and as directed.
M&L for concealed sub main wiring with two run of 2.5 Sqmm (nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, fixed to wall/ ceiling etc including one run of 2.5 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 23cm spread thick ness and consolidated (punned) upto 18cm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid for.
S&F for sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG Cable protection complete all as specified and as directed.
Labour only for horizontal boring road/ foot path, not exceeding 15 mtr in length by any method for 40 mm dia GI pipe complete all as specified and as directed.
S&F for 40 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors using suitable clamp / holder complete all as specified and as directed.
S&F in repair 40 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors using suitable clamp / holder complete all as specified and as directed.
M/s United Builders
M/S SINGH TRADERS
M/S BORAH BROTHERS
M/S Karen Enterprises
FREEZCON
M/S AUTOMOTIVE WORLD
M/s GANDHESWAR PHUKAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .