| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹6.3 L+₹7,800 (1.26%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST BIDDER | |
| 3 | L3₹6.7 L+₹53,900 (8.70%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-AOC NOT LOWEST BIDDER | |
| 4 | L4₹7.2 L+₹1.0 L (16.9%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST BIDDER | |
| 5 | L5₹7.3 L+₹1.1 L (17.6%)Rejected-AOC HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | L5 | Rejected-AOC NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | m/s bobby enterprises L5 | M/S SHIVA TRADERS L3 | M/S R.S.BUNDELA & SONS L1 | M/s Indu Enterprises L4 | PRATAP CONSTRUCTION L7 | S.R ENGINEER WORKS L2 | Allied Builders L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Prunning of tree branches not less than 1.5 mtr around the LT/HT Over head line which obstructing the maintainance of electric supply as well as illumination in area including repair of damage broken ACSR conductor GI wire and jumpers, testing of line complete all as specified and directed by Engr-in-charge. (Note-Each span minimum 30 mtr) | 1,200 | Each Span | 20 ₹24,000 | 60 ₹72,000 | 25 ₹30,000 | 20 ₹24,000 | 25 ₹30,000 | 10 ₹12,000 Lowest | 10 ₹12,000 Lowest |
| 2.00 | Excavation in in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as spfd & directed. | 240 | Cum | 90 ₹21,600 | 100 ₹24,000 | 190 ₹45,600 | 150 ₹36,000 | 100 ₹24,000 | 20 ₹4,800 Lowest | 80 ₹19,200 |
| 3.00 | Removing excavated materialn not exceeding 50mtr &deposited where direceted at a level not exceeding 1.5mtrabove the ground level. | 40 | Cum | 30 ₹1,200 | 30 ₹1,200 | 90 ₹3,600 | 50 ₹2,000 | 5 ₹200 Lowest | 30 ₹1,200 | 70 ₹2,800 |
| 4.00 | Returning , filling in spreading, levelling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed. | 200 | CUM | 30 ₹6,000 | 30 ₹6,000 | 40 ₹8,000 | 30 ₹6,000 | 80 ₹16,000 | 15 ₹3,000 Lowest | 80 ₹16,000 |
| 5.00 | Supply and laying HDPE pipe 50 mm dia for cable protection thickeness as per ISI 4984:2016 grade complete Make: Finolex/ASTHA/Supreme or Equivelent | 600 | RM | 100 ₹60,000 | 70 ₹42,000 | 45 ₹27,000 Lowest | 80 ₹48,000 | 55 ₹33,000 | 50 ₹30,000 | 85 ₹51,000 |
| 6.00 | PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured with Stranded copper conductor 1.5 sqmm and 03 core | 500 | RM | 20 ₹10,000 | 60 ₹30,000 | 12 ₹6,000 | 45 ₹22,500 | 10 ₹5,000 Lowest | 60 ₹30,000 | 120 ₹60,000 |
| 7.00M&L in replacement of cable XLPE insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs. For the following sizes. NOTE:- 1. Excavation and earth work to be measured and paid separately. | ||||||||||
| 7.01 | 4 Sq mm 2 Core. | 400 | RM | 100 ₹40,000 | 65 ₹26,000 | 80 ₹32,000 | 95 ₹38,000 | 70 ₹28,000 | 60 ₹24,000 | 45 ₹18,000 Lowest |
| 7.02 | 4 Sqmm 4 core | 400 | RM | 125 ₹50,000 | 66 ₹26,400 | 120 ₹48,000 | 110 ₹44,000 | 90 ₹36,000 | 65 ₹26,000 | 55 ₹22,000 Lowest |
| 7.03 | 6 Sqmm 2 core | 400 | RM | 140 ₹56,000 | 68 ₹27,200 | 90 ₹36,000 | 120 ₹48,000 | 85 ₹34,000 | 80 ₹32,000 | 65 ₹26,000 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Dec 2025, 6:00 pmClosed
BRIJ BIHARI, AE (CIVIL), AGE (I) TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR/REPLACEMENT OF U/S LT CABLE, LT ELCTRICAL PANEL, SWITCH GEARS AND ALLIED WORKS IN VARIOUS ZONE IN MIL STN TALBEHAT
2025_MES_741078_1
AGE(I)/TBT/TOK-78/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) TALBEHAT, LAKE VIEW CAMP
8 documents required · 8 mandatory
₹500
AGE (I) TALBEHAT
₹20,000
Yes
6 Feb 2026
25 Nov 2025
18 Dec 2025
2 Dec 2025
16 Dec 2025
9 Dec 2025
Amount
Prunning of tree branches not less than 1.5 mtr around the LT/HT Over head line which obstructing the maintainance of electric supply as well as illumination in area including repair of damage broken ACSR conductor GI wire and jumpers, testing of line complete all as specified and directed by Engr-in-charge. (Note-Each span minimum 30 mtr)
Excavation in in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as spfd & directed.
Removing excavated materialn not exceeding 50mtr &deposited where direceted at a level not exceeding 1.5mtrabove the ground level.
Returning , filling in spreading, levelling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed.
Supply and laying HDPE pipe 50 mm dia for cable protection thickeness as per ISI 4984:2016 grade complete Make: Finolex/ASTHA/Supreme or Equivelent
PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured with Stranded copper conductor 1.5 sqmm and 03 core
M&L in replacement of cable XLPE insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs. For the following sizes. NOTE:- 1. Excavation and earth work to be measured and paid separately.
4 Sq mm 2 Core.
4 Sqmm 4 core
6 Sqmm 2 core
6 Sqmm 4 core
The following items supply only :-
Insulation Tape roll
Aluminium Lug 400 Sqmm
Aluminium Lug 300 Sqmm
Aluminium Lug 240 Sqmm
Aluminium Lug 150 Sqmm
Aluminium Lug 95 Sqmm
Aluminium Lug 70 Sqmm
Aluminium Lug 50 Sqmm
Aluminium Lug 35 Sqmm
Aluminium Lug 25 Sqmm
Aluminium Lug 16 Sqmm
Aluminium Lug 10 Sqmm
Aluminium Lug 6 Sqmm
Aluminium Lug 4 Sqmm
Bolts, Nuts with Washers in different sizes/length complete
M&L for repair /replacement of damaged LT panel section of front/back/side /top and bottom portion of any size MS sheet with new of required size or thickness and fixing on existing LT panel board including necessary bracing/welding work and drilling works including necessary hinges and two coat of synthetick enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing framed work as indoors or gates of angle made out of FE 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Supply and fixing in replacement of MCCB 4 pole , 400 amp adjustablethermal and adjustable magnetic type of rating 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole , 350/320 amp adjustablethermal and adjustable magnetic type of rating 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole , 250 amp adjustablethermal and adjustable magnetic type of rating 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole , 200 amp adjustable thermal and adjustable magnetic type of rating 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole , 160 amp adjustable thermal and adjustable magnetic type of rating 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole , 100 amp fixed thermal and fixed magnetic of rating 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed
Supply and fixing in replacement of MCCB 4 pole , 63 amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
S.R ENGINEER WORKS (BID ID -3499849)
M/S SHIVA TRADERS (BID ID -3499748)
M/s Indu Enterprises (BID ID -3499901)
m/s bobby enterprises (BID ID -3496589)
Allied Builders (BID ID -3495681)
PRATAP CONSTRUCTION (BID ID -3499187)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.14 MB
Tender Documents
Tender Documents • 0.41 MB
BOQ
BOQ • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .