Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹24.3 L+₹31,030 (1.29%)Rejected-Finance | L2 | Rejected-Finance second lowest bidder | |
| 3 | L3₹24.5 L+₹55,086.80 (2.30%)Rejected-Finance | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹24.6 L+₹63,355 (2.64%)Rejected-Finance SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L4 | Rejected-Finance Fourth lowest bidder | |
| 5 | L5₹25.1 L+₹1.1 L (4.51%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest bidder |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
9 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Saugor
GE Saugor
REPAIR, REPLACEMENT OF MISC EM NATURE OF WORKS UNDER GE SAUGOR
2021_MES_497983_1
GE/SGR/TOK-61 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Saugor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER SAGAR
₹55,000
Yes
21 Mar 2022
29 Dec 2021
11 Feb 2022
29 Dec 2021
9 Feb 2022
18 Jan 2022
60 days
Amount
S&F in replacement cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed with including applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed
S&F in replacement framed work as in doors or gates of angle made out of Fe 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering (doors, gates, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) with including applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed
M&L for fabrication of existing panel cover with hinge, nut and bolt and applying two coats of synthetic enamelled painting complete all as specified and directed
S&F in replacement GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire round insulator complete all as specified and directed..
M&L for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and removing the debris to a distance not exc 50 mtr complete all as specified and directed.
S&F in repairs pipe galvanised iron light grade ( ISI marked) of 40mm bore with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed
All as per Srl item No 6 above but 50 mm bore
All as per Srl item No 6 above but 80 mm bore
All as per Srl item No 6 above but 100 mm bore
M&Lfor plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregates) as in foundation of stay assy/ pole etc, including form work complete all as specified and directed
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates) for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 2 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
S&F in replacement of HT 33 KV aluminium insulated covered conductor single core of size 95 sqmm complete all as specified and directed
Excavation in trenches in hard/dense soil not exceeding1.5m wide and not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out complete all as specified and directed..
M&L for sand cushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed. Note:-Punned thickness shall be measured and paid
M&L for bricks of sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed.
Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Taking down and re-laying reinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm or any size complete all as specified and directed.
Taking down and re-laying bricks of any size for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as specified and directed.
Taking down and Re-laying/re-routing of LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of any size laid in trenches or fixed on wall/floor/poles complete all as specified and directed
Taking down and Re-laying/re-routing of HT UG armoured heavy duty electric cables 11000 volts grade with aluminium conductor of size 95 to 185 Sq mm 3 core laid in trenches or fixed on poles complete all as specified and directed
Supply, installation, testnig and commissioning in repalcement of ACB 4 Pole, 415 V, manual drawout type with microprocessor release of capacity 630 Amps 50 KA fixing in the existing panel with necessary modification connections etc including suitable CTs complete all as specified and directed.
S&F euroload on-load change over switch 400 Amps 4 pole 415V fixed in existing LT panel with handle complete all as specified and directed.
S&F onload changeover switch (side handle) in sheet enclosure, 63 Amps, four pole, 415V, 50Hz with handle complete all as specified and directed
S&F onload changeover switch (side handle) in sheet enclosure, 100 Amps, four pole, 415V, 50Hz with handle complete all as specified and directed
Panel board double door with incomer 250A FP and outgoing 6 ways FP - 01No
250A incoming changeover switch with enclosure - 01 No
Cable alley for I/C 250A FP and FP 6 way - 01 No
MCCB 250Amps 25KA 4P Adjustable thermal and Adjustable magnetic - 01 No (Incoming)
MCCB 63Amps 25KA 4P fixed thermal and fixed magnetic - 04 Nos (Outgoing)
MCCB 40Amps 25KA 4P fixed thermal and fixed magnetic - 02 Nos (Outgoing)
Supply only HRC fuse 6 to 16 Amps as per existing to be fixed in HT panel complete all as specified and directed.
M&L for battery TM 250 P-MARK-1 of capacity 2 volts 250 AH at 10 hrs rate suitable for VCB DC supply as per existing including distilled water compete all as specified and directed.
M&L for checking of DC battery charger 30Volts of any size with minimum requirement of material all as per site requirement complete all as directed. (Note : Quoted rate shall be deemed to include opening of battery charger accessories and taking the defective items to the approved workshop)
S&F Air termination single pointed copper rod 12 mm dia 300mm long fixed on pole near gantry structure complete all as specified and directed
M&L for earth continuity conductor or main earthing lead fixed to wall & roof top in grid connection with air termination rod of size 25X 3mm aluminium strip including PVC saddles complete all as specified and directed
M&L for earthing continuityconductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X4mm galvanised iron or steel wire complete all as specified and directed
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip 25x4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge.
S&F in replacement street light pole junction box factory made Triple Pole and neutral IP 65 thermoplastic PC-GFS polycarbonate oval shape, weather proof, rust free, dust free and corrosion free, with internal embedded polyureathin material gaskit, junction box should be flame retardant and self extinguish in accordance with IEC-60695-2-11, with multilevel knockouts for cable glands in different sizes. The junction box compression of optional cable entry in four side, 25 Sqmm terminal block - 04 Nos, MCB SP 10A with flap - 01 No, Disconnected type neutral terminal 6 Sqmm-01No and Earth terminal block 4 Sqmm - 01 No including mounting arrangement complete all as specfied and directed. Make - Hensel/Sintex or equivalent make as approved by GE.
S&F in repairs round flexible PVC insulated copper cable of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed
S&F PVC conduit 20mm dia including fixing on wall/pole with necessary fixing arrangement complete all as specified and directed.
S&F framed electrical safety wheather proof chart with latest procedure for giving first aid to electricuted victim complete all as specified and directed.
M&L for painting and writing with paint in all existing sign/display boards such as SM/MES No board of equipments and other board as per the direction given by Engr-in-Charge in E/M installation 33KV MRS, Berthuma and Chittora with skilled painter after applying two coat synthetic enamel paint over a primer complete. Content, colour and letter size as approved by Engr-in-Charge complete all as specified and directed.
M&L for computerised print on PVC board with blue background and white letter of suitable size indicating incoming from, outgoing to the area of distribution, capacity and CT ratio fixed at the front side of each panel both HT and LT panel section wise complete including necessary fixing arragement in E/M installation/sub station (matter and size of letters as approved by Engr-in-Charge) complete all as specified and directed.
M/s VIKAS TRADERS
M/S NAVIN & ASSOCIATES
shubhanshu traders
M/s ajeet enterprises
SHIVALIK ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .