Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹1.3 CrRejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.3 Cr | L2 | Rejected-Finance Not the lowest Bidder |
| 3 | L3₹1.4 CrRejected-Finance | ₹1.4 Cr | L3 | Rejected-Finance Not the lowest Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to not enlisted in appropriate Class i.e Class B |
| Sl No | Description | Qty | Unit | M/s Kataria Construction Company L3 | ROYAL BUILDERS L1 | N.G BUILDERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and commissioning of 60 mm thick Pre-fabricated Insulated PUF Panels of Ext. sizes 120" x 96" x 96", Desired Room temperature: (+) 2 ˚C to (+) 6˚C,Product stored : Medical products, Product incoming qty : 20% to 25% of total load per day, rest in Inventory,Product incoming temperature : (+) 28˚C at Room Temp,Pull down time desired : 18-24 hours.No of Door openings per day/hour: 10-12 openings for 30 second per day Wall & Ceiling Insulation and thickness:60 mm thick PPGI/PPGI PUF Panels with Corner Panels embedded with Cam Lock Mechanism to prevent leakage-Eco friendly and CFC Free with PUF density of 40+/-2 Kg.Cu mtr.PUF Panels Joinery PUF Panels Joinery with Cam Locks for Modular Construction Floor insulation and thickness: PUF Slabs with Tarfelt sheet on above Kota Stone & PCC In this scope. Door type and size: 60 mm thick PP/PP Swing door of clear opening of 34” x 78” with
accessories.No of Doors: 1 Nos each room, Product stacking details : Racks or crates (well perforated) - in this scope Ambient temperature: 45˚C including Refrigeration Units with Evaporating Unit and Condensing Unit and microprocessor based Temperature Controller CCMR0200ARY16 with CRE1M400BSV16 & Microprocessor based temp. Controller of Cooling capacity 13546 BTUH & Type of Compressor : Hermetic Recip., Refrigerant : R 404A, CFC Free complete all as specified and directed by Engineer - in - Charge.
Note:-Stainless steel tray rate is included in this quoted rate and drawing should be approved by GE before execution of works.
Make : Blue Star Ltd / Voltas Limited / Haier / Daikin or equivalent as approved by GE. | 2 | Each Set | 1,80,000 ₹3.6 L | 5,00,000 ₹10 L | 3,80,000 ₹7.6 L |
| 2.00 | Supply and fixing inter connecting copper pipe between indoor and outdoor unit suitable size as per company recommended complete all as specified and directed by Engineer - in - Charge. | 6 | RM | 1,000 ₹6,000 | 1,000 ₹6,000 | 3,000 ₹18,000 |
| 3.00 | Supplying, laying, jointing and testing and commissioning of 10 sqmm, 4 core XLPE PVC insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ | 60 | RM | 230 ₹13,800 | 250 ₹15,000 | 180 ₹10,800 |
| 4.00 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge. | 13 | Cum | 120 ₹1,560 | 140 ₹1,820 | 120 ₹1,560 |
| 5.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge | 7.77 | Cum | 50 ₹388.50 | 120 ₹932.40 | 70 ₹543.90 |
| 6.00 | Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge . | 5.23 | Cum | 50 ₹261.50 | 100 ₹523 | 70 ₹366.10 |
| 7.00 | M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jently punning down complete all as specified and directed by Engineer-in-Charge.
Note : Thickness after punning shall be considered for payment. | 3.88 | Cum | 500 ₹1,940 | 600 ₹2,328 | 1,000 ₹3,880 |
| 8.00 | Supply and lay un reinforced pre cast concrete cable cover calss LV type 1 flat size 250 x 150 mm x 40mm complete all as specified and directed by Engineer-in-Charge. | 320 | Each | 25 ₹8,000 | 22 ₹7,040 | 40 ₹12,800 |
| 9.00 | S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. | 1 | Each | 4,500 ₹4,500 | 6,000 ₹6,000 | 6,000 ₹6,000 |
| 10.00 | S&F in replacement MCCB TP & N 25 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge. | 1 | Each | 4,000 ₹4,000 | 4,000 ₹4,000 | 5,000 ₹5,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
9 Jan 2026, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPL REPAIR TO ROOF OF CERTAIN TEMP BLDGS AT SGNR MIL STN, PROVN OF AUTOMATIC SYSTEM FOR PRE TREATMENT AND DISINFECTION OF LIQUID BIOMEDICAL WASTE AND 02 X WALK-IN-COOLER CAPACITY 1 TON FOR MEDICAL STORE FOR MH SGNR
2025_MES_744255_1
CA NO CWE SGNR/TOKEN-65 OF 2025-26
Open Tender
Civil Works
180 days
GE SRI GANGANAGAR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE SRI GANGANAGAR
₹2.0 L
Yes
11 Feb 2026
12 Dec 2025
10 Jan 2026
12 Dec 2025
9 Jan 2026
26 Dec 2025
Supply and fixing inter connecting copper pipe between indoor and outdoor unit suitable size as per company recommended complete all as specified and directed by Engineer - in - Charge.
Supplying, laying, jointing and testing and commissioning of 10 sqmm, 4 core XLPE PVC insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminum conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
Per Point
M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jently punning down complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F in replacement MCCB TP & N 25 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 25 Amps, triple pole (TP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 Volts per second and of capacity 5 KVA complete all as specified and directed by Engineer - in - Charge.
S & F sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including PVC "medium quality" conduit as per size required including 1 x 6 Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note :- Four length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point all as specified and directed by Engr -In - Charge
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer -in -Charge.
M&L for cutting existing steel tubing for alterations or additions (Each cut measured) of pipes size 15mm bore ,complete all as specified and as directed by Engr-in-charge.
Supply and lay un reinforced pre cast concrete cable cover calss LV type 1 flat size 250 x 150 mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Steel Water Tubing 15mm bore (dia), Galvanised, ‘medium grade, with all Fittings and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer-in-Charge.
S & F sub-main wiring with two single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in PVC conduict dia 20mm “medium quality” conduit including 2.50 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. Note : PVC cable and PVC conduit shall be ISI marked.
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘C’ series type suitable for 240 volts,10 KA, AC supply SPN 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in
S & F modular socket outlet 5 pin 6/16 Amps 2/3 pin combined 2 module complete all as specified and directed by Engineer - in - Charge.
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge
- Charge.
S & F Modular switch 1 way 16A, with box complete all as specified and directed by Engineer - in - Charge.
S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 32 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets including ridge in roof coverings complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for removing to stores complete all as specified and directed by Engineer-in-Charge.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed by Engr-in-Charge.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer -in -Charge.
S&F in repairs Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, grade-Fe-410- W(Gde-E-250) quality-B complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8, Type D2, using 40mm graded stone aggregate in foundatin, surface drains, walls, mass concrete, retaining walls & filling of post hole complete all as specified and directed by Engineer-in-Charge.
S & F modular Socket, 6A - 5 pin combined 2 Module complete all as specified and directed by Engineer - in - Charge.
S&F factory made white Coloured uPVC casement openable door made with integrated fixed panel, fabricated from multi chambered UPVC profiles (Frame :- 67x62 mm, sash : 67x 115mm, T- Profile : 78.4 x 67 mm), 2.3 mm wall thickness + 0.2 mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to UPVC profile), EPDM gaskets, Zinc alloyed white powder coated hardware (casement handle, 3D hinges, multipoint lock, striker plates and provision for 5 mm toughened glass in shutter and 18 mm prelaminated UPVC board in fixed panels. Frame fixed with 8 mm x 100 anchor fastners all as per design and manufacturer's specifications complete all as specified and directed by Engineer in Charge. Note : Rates of all type of fittings, locking arrangements, handles and all accessories as per manufacturer's instructions are included.
Supply and fixing of factory made uPVC sliding window (White Colour) of three track and three panel design including two glazed sliding shutters and one shutter with stainless steel (SS) wire mesh for fly proofing. The system shall include and integrated fixed panel made from pre-laminated UPVC board. UPVC frame fo 122x 54 mm & sash 47 x64 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead of 29.5 mm x 21.8 mm and double glazing bead of 14.5x21.8 mm comprising of UPVC chambered frame, with in built roller track and sash extruded profiles duly reinforced with 1.50+0.2 mm thick galvanised mild steel section made from roll forming process of required length, UPVC extruded interlock, EPDM gasket and provision for 5 mm toughened glass in shutter and 18 mm prelaminated UPVC board in fixed panel. Wool Pile, GI fasterner 100x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, complete all as specified and directed by Engineer in Charge. Note : Rates of all type of fittings, locking arrangements, handles, wire mesh, and all accessories as per manufacturer's instructions are included.
Dismantling wall and ceiling boards (fibre, pulp, AC insulation, etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets & snap grid and any description complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge.
S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm th. on fair faces of brick or concrete surfaces in CM 1:4 in two layers and second layer mixed with integral water proofing compound @ 2% and finished even and smooth without using extra cement as external plaster on walls complete all as specified and directed by Engineer-in-Charge. Note : WPC measured and paid separately.
Taking down internal/external cement plaster on brick or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed by Engineer-in-Charge.
Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks, straight or curved on plan, exc 6m mean radius built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm th. on fair faces of brick or concrete surfaces in CM 1:6 in finished even and smooth without using extra cement as external plaster on walls complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coat Acrylic emulsion with 1st quality acrylic interior emulsion (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over plaster of paris putty of 2 mm thickness over newly plastered surface to prepare the surface even and smooth complete all as specified and directed by Engr in Charge
M&L two coats of acrylic interior emulsion over old decorated surfaces of wall after complete removal of existing treatment including preparation of surface including priming coat as per manufacturer instructions and wall care putty 1.5mm to 2.5mm thick complete using roller complete all as specified and as directed by Engr-in-Charge
M&L for preparation of old steel surfaces of any description over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of newly plastered surfaces of any description and applying Two or more coats of 100% Premium exterior weatherproof acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and 1.5mm to 2.5mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
S&F 8 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed by Engineer-in-Charge.
M & L preparation of old plastered surfaces of walls and applying finishing walls with Acrylic Smooth exterior emulsion (weather coat) paint of required shade old work (one or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm and wall care putty 1.5mm to 2.5mm thick complete using roller complete all as specified and directed by Engineer-in-Charge.
S&F Gl frame work for snap grid/seamless ceiling of size 605x605mm comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer-in-Charge.
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
Dismantling for floor hearth or wall tiling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L 600/x300x7mm / 450x300x7mm mm thick glazed ceramic coloured tiles as in vertical sufaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10mm backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L machine cut kota stone slab flooring 20-25mm thick (minimum size 55 cms x 55 cms) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing including 15mm of screed bed in CM 1:6 aggregate complete all as specified and directed by Engineer-in-Charge.
M&L granite (of any type) work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, hand wash platform and like laid over and including 12 mm thick cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick cement concrete type C-1, 1:3:6 using 20mm graded aggregate as in plinth protection complete all as specified and directed by Engineer - in - Charge.
M & L machine cut kota stone slabs as in vertical surfces such as risers of steps/vertical surfaces 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing also moulding edges including 10mm of backing coat in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thick cement concrete flooring type B 1, 1:2:4 using 20 mm graded aggregate finished even and fair complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of CPVC pipes of dia 20 mm SDR 11 & Plain CPVC SDR 11 inlcuding all fittings i.e.Brass elbow, Brass Tee, Male threaded Brass adaptor, Female threaded brass adaptor, unions ball valves, flange and tank adaptor etc) concealed including cutting chases to brick wall/ceiling or laying in floors/trenches and making good complete all as specified and directed by Engr in Charge.
Supplying and laying of CPVC pipes of dia 25 mm SDR 11 & Plain CPVC SDR 11 inlcuding all fittings i.e.Brass elbow, Brass Tee, Male threaded Brass adaptor, Female threaded brass adaptor, unions ball valves, flange and tank adaptor etc) concealed including cutting chases to brick wall/ceiling or laying in floors/trenches and making good complete all as specified and directed by Engr in Charge.
Taking up or down GI steel water tubing 15mm bore and connections including fittings from floor/walls/ceiling complete all as specified and directed by Engineer-in-Charge.
Taking up or down GI Steel water tubing 20mm bore and connections including fittings from floor/walls/centrings complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks any type exc. 500 ltr but nexc 1000 ltr complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, Testing and commissioning of 60 mm thick Pre-fabricated Insulated PUF Panels of Ext. sizes 120" x 96" x 96", Desired Room temperature: (+) 2 ˚C to (+) 6˚C,Product stored : Medical products, Product incoming qty : 20% to 25% of total load per day, rest in Inventory,Product incoming temperature : (+) 28˚C at Room Temp,Pull down time desired : 18-24 hours.No of Door openings per day/hour: 10-12 openings for 30 second per day Wall & Ceiling Insulation and thickness:60 mm thick PPGI/PPGI PUF Panels with
S&F rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part -I (1000 Ltrs) capacity complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping), in flat surfaces etc. complete all as specified and directed by Engr in charge.
M&L TMT bar 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
S & F in repair 20 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair 15 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair chromium plated stop valves, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer-in-Charge.
S&F in repair chromium plated Angle stop valves, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer-in-Charge.
S&F in repairs chromium plated 15mm bib taps (half/quarter turn) cast copper alloy, chromium plated fency type with crutch or butterfly handle screwed down screwed for Iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F CP gratings 100 mm dia of PTMT fixed in repairs.(Minimum weight 25 gms ) complete all as specified and directed by Engineer-in-Charge.
Demolition concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer - in - Charge.
S&F 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-Charge.
M&L providing reinfoced cement concrete (nominal mix) in cement concrete 1:2:4 Type B1(20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. Note : Rates of Demolition of RCC of any descrition are included
M&L75 mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate) filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L providing precast cement concrete in PCC (1:2:4) type B-1 with 20 mm graded aggregate for kerb stone and similar works with plain fair finishes including chamfers, weatherings, throat- ing etc. and setting in mortar (1:4) complete with joints to match complete all as specified and directed by Engineer - in - Charge.
M&L Colured
40 cm x 40 cm x 10 mm thick Non skid (Hi Traffic grip tiles) set jointed and pointed in neat cement slurry in floors over 20mm of screed bed in CM 1:4 including coping at edges in PCC Type B1 (1:2:4) ( rates of dismantling of stone slabs and tiles are included complete all as specified and directed by Engineer in Charge.
S& F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, clips, sliding channel, wheels etc. complete all as specified and directed by Engr in Charge
Taking down steel window / ventilators complete all as specified and directed by Engineer - in - Charge.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
M&L for sand filling (25mm thick) under floors or in foundations including watering and consolidation complete all
as specified and directed by Engineer-in-Charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/floors or wall/complete all as specified and directed by Engr in Charge
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/floors or wall/complete all as specified and directed by Engr in Charge
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC 'S/P' Trap complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and directed by Engineer - in - Charge.
Providing and fixing factory made uPVC white colour Sliding window (having area not exc 2.0 sqm) Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm) having provision for air cooler/ Window AC. Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making rrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick alvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) complete all as specified and directed by Engineer-in-Charge.
S&F Factory Made 30mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Flush Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N (Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws and including 125 mm SS hinges with stainless steel screws (03 Nos ), 200 mm long Stainless steel tower bolt (02 Nos) and 300mm long Stainless steel sliding bolt (01/02 Nos) & Stainless steel handles (02 Nos) complete all as per direction of Engineer -In-Charge. Note: -(i) Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/ Bathroom/ Toilet/ Kitchen/ Balcony Doors.
S&F Factory 30 mm thick 100 % solid WPC (Wood Polymer Composite) Laminated Wiremesh shutter of size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: Including 125 mm SS hinges with stainless steel screws (03 Nos ), 200 mm long Stainless steel tower bolt (02 Nos) and 300mm long Stainless steel sliding bolt (01/02 Nos) & Stainless steel handles (02 Nos)
S&F 110mm bore PVC (SWR) bend/Tee, any radius with access door complete all as specified and directed by Engineer-in-Charge.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of but of Frame size 65x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note : Rates of Taking down are included. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S & F in replacement compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1X10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer-in-Charge.
M & L for 40mm thick cement concrete type B-1, 1:2:4 using 20mm graded aggregate as in flooring , finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
Supply , Installation ,Testing & Commissioning of Fully Automatic Liquid Waste Treatment System , outer body surface should made of Stainless Steel 304 grade body and tanks should have made of Stainless Steel 304 grade with inner fiber lining making the tanks corrosion free, with manual operating mode with the capacity of 150 Ltr to be installed at source of biomedical liquid waste generation, operational electric power supply 210V-230V, 50 Hz compatible with Indian conditions. The equipment should have capacity to treat more than 1000 Litres of Liquid waste in 10 hours of functioning. The equipment continuous treatment cycle to ensure uninterrupted workingwith an option to treat any level (i.e. 1.4 Liter or 2.7 Liter or 3.5 Liter……..etc) of liquid medical waste automatically or manually. The equipment should only use 10% NaClO in 1:10 ratio as per CPCB guidelines for treatment of infectious liquid waste at source. The equipment should have following Specifications :- (i) Programmable Logic controller (PLC) based touch screen Thin FilmTransistor (TFT) color display minimum 4.25 Inch to operate equipment with touch pencil. Only PLC operated equipment required for ease of use. HMI or PCB Control based equipment are not accepted. (ii) TFT Display electrical control panel should be water proof, mild acid and alkali proof (Concentration of upto 1% for 2 minutes). (iii) Functions like starting cycle, dispensing sodium hypochlorite solution and drainage should be done by equipment automatically. The Home Screen should display pictorial of the cycle stage – NaClO dispensing, NaClO mixing and drainage. (iv) Option for data logging using USB 2.0 or higher. (v) Cycle data for record keeping and give print out of cycle data, present and past. Equipment should have minimum data storage facility for 10,000 cycles. (vi) User login protected with facility to configure Hospital Name, Lab Name and Admin protection by a Pass Code. The equipment should have provision for vendor login for servicing and maintenance of the equipment. (vii) Real time pH Level sensors to ensure that the pH Level of treated waste being discharged is in compliance to the parameters set by Central Pollution Control Board of India (CPCB). The equipment should have provision to adjust pH level manually if required. The pH neutralisation valve should only open after the completion of treatment cycle automatically only if pH is out of range further the equipment should display alert on screen t
hat the pH is out of range. (viii) Audio visual alarms for low/full levels of hypochlorite solution with display to full level for treatment and storage tanks, real time non contact level sensors in Storage Tank, Treatment Tank and NaClO tank with audio visual alarm with facility to mute for long life of equipment. (ix) Safety feature where the treatment cycle should not start in automatic or manual mode if there is insufficient level of sodium hypochlorite solution in the equipment. It should give an audio-visual alert for the same. (x) Electrically controlled motorized mixing of sodium hypochlorite solution with medical liquid waste at regular intervals. (xi) Safety features to avoid overfilling of any of the tanks. The equipment should have electrically controlled safety valves in all the tanks for overflow protection. (xii) The equipment must have efficacy test reports by reputed Industrial Research of treated liquid with ≥99.99% efficacy. (xiii) Hot and cold water tap with hands free elbow function. (xiv) Automatic drainage with additional provision to drain liquid waste manually in case of an emergency. (xv) Emergency stop button to start and stop any time in during treatment cycle. (xvi) User manual. (xvii) 2 years warranty free of charge. Make : ECOKLIEN / ARVS Equivalent Private Limited / SS Technomed (P) Limited / Soclean
S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars,aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and sliding aluminium channel, wheels and locking arragements , anodised aluminium fittings such as peg stays 150mm long, hinges type B-21 100mm long, suitable handle and tower bolt complete all as specified and directed by Engr in Charge
S&F in replacement LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge.
Refixing the ceiling fan complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint (1 st quality) over a coat of red oxide complete all as specified and directed by Engineer-in-Charge.
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing (Fe-410- W (Gde-E-250) quality complete all as specified and directed by Engineer-in-Charge.
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to warf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting with fixtures such as sockets, ceiling roses, pendants, batten holders, regulators etc and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge.
Taking down existing tube light/ mirror light/ building light etc of any type/make/capacity from building/ rooms including testing serviceability complete all as specified and directed by Engineer - in - Charge.
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 2.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for modular metal flush boxes suitable length and Min 1.6 mm thickness, Min 51 mm depth for mounting, switches, sockets,fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 2.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.
S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer - in - Charge.
S & F in replacement of existing light fitting with LED batten with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store complete all as specified and directed by Engineer-in-Charge.
S & F modular switch 5/6 Amps single pole one way,one module complete all as specified and directed by Engineer - in - Charge.
Dismantling of cast iron or reinforced concrete drain pipes jointed in cement mortar and taking off our trenches/wall if required complete all as specified and directed by Engineer-in-Charge.
S&F in replacement security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including steel dia 25mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S & F modular Socket, 16A - 2/3 pin combined 2 Module complete all as specified and directed by Engineer - in - Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_833378.xls
BOQ • 1.09 MB
Tender65.pdf
Tender Documents • 1.29 MB
Download all tender documents and submit your bid