Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC MADHUBANI BAZAR PURNEA PO PARORA PS K NAGAR PURNEA BIHAR | PURNEA | PURNEA | BIHAR | 854301 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹15.6 L+₹79,245 (5.35%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹15.7 L+₹90,935 (6.14%)Rejected-Finance 00 BAIKUNTHPUR SIRSA MANPUR BAIKUNTHPUR SIRSA MANPUR GOPALGANJ 841409 GOPALGANJ BIHAR 841409 | GOPALGANJ | BIHAR | 841409 | L3 | Rejected-Finance Higher bid value |
Tender Value
₹14.8 L
EMD Value
₹29,800
Closing Date
29 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (AF) PURNEA
AGE (I) (AF) PURNEA,CHUNAPUR,PURNEA
ENHANCEMENT OF ELECTRICAL SUPPLY LOAD FOR NFS PROJECT AT AFS PURNEA UNDER AGE (I) (AF) PURNEA
2020_MES_349842_1
C/8861/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) PURNEA
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE I AF PURNEA
₹29,800
Yes
18 Jul 2020
4 Jun 2020
3 Jul 2020
4 Jun 2020
29 Jun 2020
17 Jun 2020
60 days
Amount
Exavation in trenches, 1.5m wide and n. exc. 1.5m in depth , fo foundation etc..n.exc 10 sqm on plan and n. exc 1.5 m in depth and gatting out in soft / loose soil for laying of cables all as specified and directed by Engr-in-charge.
Returnig , filling in, including spreading, leveling , watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and directed by Engr-in-charge.
Removing excavated material n. exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for sand cushioning / sand covering for underground cable protection and consolidated and compected with clean dry sand complete all as specified and directed by Engr-in-charge.
Supply & laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50 mm all as specified & directed.
Supply, installation, commissioning and testing of HT transformer step down, 11/0.433 KVA, 3 phase 4 wire system with off load tappings on HT side to vary secondary voltage within limit, indoor type copmlete with standard fittings and installing complete including jointing materials, connecting with electrical system, copper wound, initial oil filling to appropriate level of capacity 315 KVA all as specified with the following specification:- (i) No load voltage ratio 11/0.433 KV (ii) No of Phase – Three (iii) Frequency – 50 c/s (iv) Connection – Delta/Star (v) Temp rise in oil – 45º C (vi) Temp rise in winding - 55º C (vii) Material winding – copper wound (viii) High voltage/low voltage – Bushing with box (ix) Service – indoor (x) Neutral – Internally connected with earth lead and bush (xi)Oil level monitor device
Supply and laying in replacement of unserviceable cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with aluminum conductor, 11000 volts (Earthed), grade cross sectional area 150 Sqmm 3 core coplete all as specified.
Transformer foundation of size 2 x 2 x 1.8 mtr with stone masinary including excavation, PCC and external plaster along with pcc of side area of foundation complete all as specified and directed .
M&L Earthing complete with copper plate 600x 600x 3.15mm thick, burried directly in ground ( earth pit not less then 2.25M deep below ground level) with top edge of the plate not more then 1.5M below ground level, connected to 20x3 mm copper strip earth lead by means of bolt, nuts, check nuts and washers copper earth strip not lessthen 7.5m long with protected by 40 mm dia light grade pipe and other end connected to earth test point or main controling switch as directed including funnel with watering pipe 20 mm dia light grade GI pipe, wire mesh, charcol and common salt, concrete earth pit in PCC (1:3:6) type C1 casr iron frame cover, including necessary excavation , earth work in soft/loose soil and disposual of soil to a distance not exc 50 Mtr and necessary testing complete all as shown in electrical plate No 5 of SSR Pt- I , 1991 complete all as specified and directed by Engr-in -charge.
Supply and laying and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty), 1100 volt grade with standard aluminium conductor of size 120 sqmm 3.5 core.
Supply & fix LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, overload protection, no-volt release with necessary CTs,meter and cable boxes of rating 630 Amps
Supply and fixing of HDPE pipe PN 10 for cable protection , laid in trenches or pole for passing HT cables of sizes 100 mm dia
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, nuts & screws as specified type 410 SP-55 (11 metres long) alonwith necessary arrangement for connection to existing 2 pole structure with ACSR Conductor and pin insulator,complete as specified and as directed by Engineer-in-charge.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structrual steel sections including nuts, bolts, waashers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated of directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete as specified.
M&L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed woth MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete as specified.
Supply and fixing switch air break, gang operated, out door, triple pole, tilting type, suitable for vertical mounting, consisting of hot dipped electro-plated galvanized channel base having 3 Nos. 11 KV post type insulator, copper/copper alloy tilted contacts, copper or copper plated MS arcing horns capable of making and breaking the magnetizing current complete with horizontal bar, GI pipe 25 mm bore(medium grade) operating mechanism with operating handle and with pad locking arrangement worked from ground level, drop out expulsion fuses assembly, working voltage 11000 volts, current rating up to 400 Amps including testing complete all as specified and directed.
Supply and fixed cable jointing kit for outdoor termination cold shrink type joint complete with jointing material and accessoriessuitable for 3 core XLPE Armoured aluminum conductor cable of size 150 sqmm. 11000 volts grade (11KV). coplete all as specified.
S&F Anti climbing device:spikes type fabricated out of M.S bars(round,square,flat)including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole.
Material and labour providing PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in foundation of poles/struts/stays complete all as specified and as directed.
Material and labour for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in coping or plinth block of electric poles including necessary form work, to achieve fair finish surfaces without using extra cement complete all as specified and as directed.
M/S. MAJUMDER CONSTRUCTION
M/S. R.K. ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .