Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹13.8 L+₹93,857.50 (7.32%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC Being not lowest | |
| 3 | L3₹14.4 L+₹1.6 L (12.7%)Rejected-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-AOC Being not lowest | |
| 4 | L4₹18.9 L+₹6.1 L (47.8%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-AOC Being not lowest | |
| 5 | L5₹22.4 L+₹9.6 L (75.1%)Rejected-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L5 | Rejected-AOC Being not lowest |
Tender Value
Refer Docs
EMD Value
₹59,500
Closing Date
20 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Sidhartha Singhal
GE (P) Dappar
Spl repair to LCs Air Terminal and other connected work of ESH/Mag in tech area at Mil Stn Dappar under GE (P) Dappar
2021_MES_473288_2
GE (P) DPR-28/2021-22
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹59,500
Yes
26 May 2022
12 Oct 2021
22 Nov 2021
12 Oct 2021
20 Nov 2021
13 Oct 2021
12 Oct 2021 - 13 Oct 2021
60 days
Amount
Dismantling and taking down Aluminium strip fixed on roof, floor wall and taking out old saddles and earthing strip in original state all as specified and as directed.
Dismantling and taking down Aluminium strip fixed on roof, floor wall and taking out old saddles and refixing of existing serviceable aluminium strip on new PVC saddles and connecting to earthing strip in original state all as specified and directed.Note : New Aluminium strip 25 x 3 if requires mm will be measured and paid under relevent items of this schedule
Supply and fix in replacement PVC insulator along with screws, accessories on wall, roof etc suitable for fixing aluminium strip of size 25x3 mm complete including taking down on old unsv insulators complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement air termination single pointed aluminium rod 12 mm dia, 300 mm long fixed complete as specified and directed. Note : Cost of PCC block will be measured and paid separately Cost of minor job and spares required for fixing of aluminium rod on PCC block & for fixing Aluminium strip to rod is deemed to be included in the quoted rate.
Supply and fix in replacement galvanized iron strip of size 32x 6 mm to be fixed on wall or to be laid in ground , complete all as specified and including taking down from any position and any places and as directed by Engr-in-Charge.
Supply & fix in replacement fix aluminium strip 25x3 mm to be fixed on PVC insulators with fixing screws on roof, wall including down conductors strip etc, and taking down of old aluminum conductor srtip from any position and places all as specified and directed.
Dismantling and removing old unserviceable earthing and material and labour for earthing complete wih galvanised steel earth plate electrode 60cmx60cmx6.00 mm thick burried directly in ground vertically toa depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level connected to and including galvanized iron earth strip of size 32x6 mm by means of bolts, nuts , chucknut, and washer etc , made of GI and connecting to earth test point all as shown as electrical plate to 5 of SSR Pt -1 2009 an as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C-I earthing chamber, precast RCC slab 50 mm thick in cement concrete (:) type B1 reinforced with welded steel wire fabricated weight not less than 4 Kg/ Sqm . Funnel with GI watering pipe 20 mm bore medium grade wire mesh test point etc , complete all as specified.
Supply and fix in replacement test point terminal block made of Gun Metal or phosphrus bronze of size 75 x 75 x 25 mm drilled & screwed including 03 Nos 8mm dia 25mm long hex head screw including taking out all broken test point terminals from any position and any places.
Taking out old GI earthing strip of size 32x 6 mm embeded in earth and removing its bends and complete all as specified and directed.
Demolition and taking out old damaged earth pit PCC chamber with cover. M& L for preparation of new PCC chamber in cement concrete 1:2:4 type B1 cover duly reinforced with XPM (weight not less than 4 Kg/sqm and CI frame and other provisions all as shown electrical plate No-3 of SSR-2009 Part-I complete all as specified and directed.
Relaying it properly making connection to test point terminal etc and testing complete all as specified and directed. Note : Minor material and job required for connecting earthing strip to existing earthing strip & to the test point is deemed to be included in the quoted rate.
Excavation in trenches in any type of soil not exc 1.5 m wide and not exc 1.5 m depth and getting out including forming bottom surfaces to required level or slope, complete all as specified and directed.
Returning filling in excavated soil including spreading, leveling, watering and well ramming, in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M & L for laying GI tubes light grade, 40 mm dia for protection of earth continuity leads.
M&L cement concerete 1:2:4 type b1 using 20mm graded mechanically crushed stone aggregate as in coping complete all as specified and directed by Engr-in-Charge
Testing of lightting arrester assembly using an insulation tester by dismantling of the assembly from the test point all as specified by E-in-C including submitting a test report per bldg all as per sample data sheet as received from Engr-in Charge.
Note : Items 1 to 17 The contractor has to make his own arrangements for provision of electricity.
HARISH SALES CORPORATION
The Rahul Vig
SANJEEV ENTERPRISES
SUN MANN ENGINEERS
M/S RAGBIR ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .