| Sl No | Description | Qty | Unit | D R ENTERPRISE L1 |
|---|---|---|---|---|
| 1.00 | Supply installation Testing commssioning 4.0 TR inverter vertical tower AC to be run at 50Hz air flow volume (wet CFM)(high/low) 877/704 with rotary or scroll compressor and with first charge of refrigent R410A and LED remote with night glow function at remote buttion witn suction tube outer dia 19.5mm specification as per All specifications as per IS1391 (Part 2): 1992 Room air-conditioner | 21 | Nos | 2,14,500 ₹45,04,500 Lowest |
| 2.00 | Supply installation of copper piping as per the size of the machine etc. complaete as required | 186 | mtr | 1,150 ₹2,13,900 Lowest |
| 3.00 | Supply installation of pvc insulated 4 core 4 sq mm communication cable as per the machine specificaton | 100 | mtr | 190 ₹19,000 Lowest |
| 4.00 | Supply and installation of Clamp for Outdoor Unit Fitting | 21 | set | 1,350 ₹28,350 Lowest |
| 5.00 | Supply and installation of Drain pipe 25mm dia CPVC inlcuding nitrile insulation complete as required | 185 | mtr | 180 ₹33,300 Lowest |
| 6.00Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required | ||||
| 6.01 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 180 | mtr | 220 ₹39,600 Lowest |
| 7.00Supplying and , fixing of following modules GI boxes along with modular base & cover plate for modular switch in recess etc as required | ||||
| 7.01 | 1 or 2 Module | 21 | each | 210 ₹4,410 Lowest |
| 8.00Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | ||||
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
30 Jun 2026, 2:00 pmClosed
Superintending Engineer
IPM Section, IIT Guwahati
SITC of 4TR vertical tower AC for BH Auditorium, Mini Auditorium and Conference Centre of IITG Campus
2026_IITG_914611_1
IITG/IPM/NIT/C/2026-27/35
Limited
Electrical Works
Works
7 days
IIT Guwahati
Please refer tender document
2 documents required · 2 mandatory
₹2,000
Payable To IIT Guwahati
₹1 L
2 Jul 2026
24 Jun 2026
1 Jul 2026
24 Jun 2026
30 Jun 2026
24 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply installation Testing commssioning 4.0 TR inverter vertical tower AC to be run at 50Hz air flow volume (wet CFM)(high/low) 877/704 with rotary or scroll compressor and with first charge of refrigent R410A and LED remote with night glow function at remote buttion witn suction tube outer dia 19.5mm specification as per All specifications as per IS1391 (Part 2): 1992 Room air-conditioner | |||||
| 2Supply installation of copper piping as per the size of the machine etc. complaete as required | |||||
| 3Supply installation of pvc insulated 4 core 4 sq mm communication cable as per the machine specificaton | |||||
| 4Supply and installation of Clamp for Outdoor Unit Fitting | |||||
| 5Supply and installation of Drain pipe 25mm dia CPVC inlcuding nitrile insulation complete as required | |||||
| 6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required | |||||
| 6.01 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | - | mtr | - | - |
| 7Supplying and , fixing of following modules GI boxes along with modular base & cover plate for modular switch in recess etc as required | |||||
| 7.01 | 1 or 2 Module | - | each | - | - |
| 8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
NIT.pdf
Tender Documents • 0.71 MB
BOQ_961178.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .