Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.2 LAccepted-AOC | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹37.3 L+₹2.7 L (7.90%)Rejected-Finance B 33 171 PATEL NAGAR GURDASPUR ROAD PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹38.7 L+₹4.2 L (12.1%)Rejected-Finance 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | 3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | 4₹43.8 L+₹9.3 L (26.8%)Rejected-Finance | 4 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pankaj Vyas, SE, IDSE
HQ Commander Works Engineer No.2, Brichgunj, Junglighat Post, Port Blair - 744 103
REPAIR AND MAINTENANCE TO HIGH TENSION EXTERNAL ELECTRIC SUPPLY DISTRIBUTION SYSTEM UNDER GE BRICHGUNJ, PORT BLAIR
2021_MES_492941_1
80233/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Port Blair
REPAIR AND MAINTENANCE TO HIGH TENSION EXTERNAL ELECTRIC SUPPLY DISTRIBUTION SYSTEM UNDER GE BRICHGUNJ, PORT BLAIR
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹80,000
Yes
7 Mar 2022
15 Dec 2021
15 Jan 2022
15 Dec 2021
12 Jan 2022
29 Dec 2021
15 Dec 2021 - 22 Dec 2021
60 days
Amount
Material and Labour for Jointing in repairs straight through joint, heat shrinkable, suitable for HT, XLPE cable with aluminum conductor of size 50 to 95 Sqmm, 11 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for Jointing in repairs cable straight through joint, heat shrinkable, suitable for HT, XLPE cable with aluminium conductor of size 120 to 185 Sqmm, 11 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for Jointing in repairs cable end termination kit, heat shrinkable, outdoor type, suitable for HT, XLPE cable with aluminium conductor of size 50 to 95 Sqmm, 11 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for Jointing in repairs cable end termination kit, heat shrinkable, outdoor type, suitable for HT, XLPE cable with aluminium conductor of size 120 to 185 Sqmm, 11 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for Jointing in repairs cable end termination kit, heat shrinkable, indoor type, suitable for HT, XLPE cable with aluminium conductor of size 50 to 95 Sqmm, 11 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour for Jointing in repairs straight through joint, tapex joint, suitable for HT, XLPE cable with aluminium conductor of size 95 Sqmm, 33 KV rating and testing after jointing complete all as specified including dismantling old cable joint of any description complete including earth work all as specified and as directed.
Material and Labour in repairs Silica Gel breather capacity 250Gms made of aluminium top and bottom, Transparent unbreakable centre portion to check silica gel condition; clear view Polycarbonate oil cup- Screwable type; Air tight Nitrile rubber O-Ring; center steel tie rod; Connection: 1/2 or 3/4 inch thread or Flange suitable of mounting in of capacity upto 400 KVA complete all as specified and as directed.
Material and Labour in repairs Silica Gel breather of capacity 1 kg made of aluminium top and bottom, Transparent Acrylic center portion of 4mm wall thickness to check silica gel condition; clear view Polycarbonate oil cup- Screwable type; Air tight Nitrile rubber O-Ring; center steel tie rod; Connection: 1/2 or 3/4 or 1 inch BSP thread or Flange suitable of mounting in 1/ 2 MVA Transformers all as specified and as directed.
Material and Labour for preparation of old surfaces of 11 mtr high RCC Poles and applying one coat of cement based paint on RCC poles including painting black and yellow strips of 30 cm each on poles upto 1.0 m from the bottom and numbering with 60mm sized letter with synthetic enamel paint complete all as specified and as directed.
Material and Labour for preparation of old surfaces of 9 mtr high RCC Poles and applying one coat of cement based paint on RCC poles including painting black and yellow strips of 30 cm each on poles upto 1.0 m from the bottom and numbering with 60mm sized letter with synthetic enamel paint complete all as specified and as directed.
Dismantling of Insulators HT, 11 KV pin, post, disc type and removing from its locations, making good the disturbed surfaces to match with the existing surfaces, and taken as credit all as directed and as specified
Supply and fix in porcelain/Polymer post insulator suitable for 11000 volts grade complete all as specified and as directed.
Supply and fix in Pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
Supply and fix in repairs 33 KV post- top insulator porcelain vitreous white or Brown or green including galvanized mild steel straps as per sample all as specified and as directed.
Material and Labour for loose filling of 40 mm graded stone aggregates in plinths of out door transformer, sub stns, panel boards yard complete all as specified and as directed.
Material and Labour for cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate as in walls etc., including necessary form work and finishing to exposed concrete surfaces even and fair complete all as specified and as directed.
Supply and fill Silica Gel in breathers complete including removing old silica gel all as specified and as directed.
Filling fresh new EHV grade-II for topping up transformer oil duly filtered, ISI marked as per IS:335/93 with amdt. No.1 (Reaffirmed: 2005) dehydrated to give BDV value not less than 50 KV when tested with 2.5 mm gap electrode complete all as specified and as directed.
Online Filtration of transformer oil including checking Dielectric strength before and after filtration of oil for transformers located in Brichgunj area with suitable equipment having filtration, heating and pumping facility to improve the dielectric strength / insulation value of transformer oil complete all as specified and as directed. Note : Dielectric strength of transformer oil after filtration/dehydration shall not be less than 50 KV. Oil for topping up shall be measured and paid for separately as supply only under relevant items of this schedule.
Supplying, laying, Jointing, testing and commissioning of HT UG cable, XLPE insulated, screened insulated, armoured and PVC bedded, 11 KV grade (heavy duty) suitable for earthed system with aluminium conductor of size 3 core 95 sqmm conforming to IS-7098 Part II laid in trenches, fixed to walls or passing through pipes and connecting up including taking out unserviceable cable complete all as specified and as directed. Note : Earth work excavation shall be measured and paid separately under relevant item
Supplying , laying, Jointing, testing and commissioning of HT UG cable, XLPE insulated, screened insulated, armoured and PVC bedded, 33KV grade (heavy duty) suitable for earthed system with aluminium conductor of size 3 core 95 sqmm conforming to IS-7098 Part II laid in trenches, fixed to walls or passing through pipes, properly fixed with suitable cable glands and connecting up including taking out unserviceable cable complete all as specified and as directed.
Material and Labour for repair and overhauling of HT 11KV vertical Air Break switch, Outdoor type by cleaning the contacts, applying grease and replacement of defective unserviceable spare parts for easy operation on ground level complete all as specified and as directed. Note :- (i) All spares required to be replaced shall be measured and paid separately under relevant items of this schedule. (ii) Minor items like nut, bolts, washers etc are deemed to be included in the quoted rate.
Supply only Male contact/Moving contact blade suitable for 11KV complete all as specified and directed.
Supply only Female contact/Fixed contact Jaw suitable for 11KV complete all as specified and as directed.
Supply only MS jumper carrier complete all as specified and as directed.
Supply only Tinned Copper flexible Jumper 200 amps complete all as specified and as directed.
Supply only repairs top contact/ L contact for drop out fuse suitable for 11 KV all as directed by the Engineer in Charge.
Supply only bottom contact for drop out fuse suitable for 11 KV all as directed by the Engineer in Charge.
Supply and fix in replacement DO Fuse Elements 5 to 20 Amps rating all as directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified. Note : A deduction of 10% shall be made from total computed volume of filling to cater in bulkage irrespective of machinery used for ramming.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed
Supply and lay pulverized stone dust for cable cushioning in trenches or in duct complete all as specified and as directed.
Supplying and laying unreinforced precast cement concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm made out of M-20 grade PCC as per IS 5820:1970 for cable protection, embossed with "ELECTRIC" on top surface complete incl taking down old all as specified and as directed.
Material and Labour for dismantling Oil filled CT/PT from structure at 33 KV Switchyard after switching off supply and carefully removing electrical connection, checking the IR value, opening the top cover by taking down the bolts and nuts, draining oil, checking the dielectric strength of drained oil, filtration/ dehydration and building up the BDV value not less than 50 KV, refilling the oil, fixing back the top cover with new gasket and tightening bolts to restrict any leakage, cleaning terminals, scrapping thoroughly the existing corroded paint / rust, filling the cavities with suitable filler material & painting with one coat of silicon acrylic heat resistant paint of approved quality and colour, mounting back the PT/CT and giving necessary electrical connection all as directed and as specified.
Material and Labour for de-carbonsing /cleaning complete HT panels board, 11 KV cubicle type, consists of bus bar chamber, circuit chamber and metering chambers, by opening the spout/bus covers inspecting the bus bar joints, cleaning of bus bars, checking the bus bar spouts and circuit spouts for any flash overs/tracks, applying Becktol (red) solution to the bus bars and spouts having moderate tracking, applying HT insulated red compounds/Monoplist compound at the bus bar joints after tightening of joints, cleaning of bus bar insulators and bus bars with CTC and ensure proper decarbonisation and re-assembling complete all as directed by Engineer-in-Charge.
Material and Labour for decarbonsing/cleaning the cable compartment of Ring Main Unit 3 Way, 11 KV, consists of End joints, Current transformers, cable boots, bushings, by opening compartment cover by carefully switching off the main input cable supply and necessary switching ON of Earth switch of RMU thereby inspecting the end joints, current transformer, bushings and cable boots, checking the bushings for any flash overs/tracks, applying Becktol red solution to the bushings having moderate tracking, applying suitable HT insulated tape over anti tracking tube to prevent further tracking on, cleaning of end joints, CTs & cable boots with CTC and ensure proper decarbonisation and re-assembling complete all as directed by Engineer-in-Charge.
All as per item No 37 above but of RMU 4 Way
All as per item No 37 above but of RMU 6 Way
All as per item No 37 above but of RMU 9 Way
All as per item No 37 above but of RMU 1 Way
Material and Labour for servicing and testing of HT vacuum circuit breaker of capacity up to 1250A, of any make, 33 KV, comprising of the following to the entire satisfaction of Engineer-in-Charge. Note: Quoted rate is inclusive for the following services:- (i) Checking the serviceability of the following parts carefully including cleaning, adjustments and re-assembling the unit complete. (ii) Checking the spring charging mechanism of the VCB, checking the operations of the closing/tripping trough closing/tripping coils electrically as well as manual charging including cleaning adjustments complete for the following. (iii) Checking the condition of the spring charging motor along with gear box including servicing to the motor commulator bushes, lubrication of bearing surfaces etc. (iv) Cost of additional hardware like, bolts, nuts , washers and spring washers, petroleum jelly ctc, to put the breaker in serviceable condition is deemed to be included in the rates quoted. (v) Making functional by carrying out minor repairs all the non functional circuits and indicating system like VCB Trip, CB ON, CB OFF, CB Service, Spring Charging etc (vi) Test shall include IR, CRM, time Test and all relevant routine test at site including submission of test reports.
Taking down the HT vacuum circuit breaker of capacity up to 800A, of any make, 11 KV, for servicing and re-assembling complete, comprising of the following including testing and commissioning to the entire satisfaction of Engineer-in-Charge. Note: Quoted rate is inclusive for the following services:- (i)Taking out the VCB from the enclosure & checking the serviceability of the following parts carefully including cleaning, adjustments and re-assembling the unit complete. (ii) Cleaning the external surface of bushings with CTC/CRC or Liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to breaker operation have not caused the bushings to move resulting misalignment of contacts. (iii) Checking the breaker bushing of bus bar and circuit side inspecting the interval surface carefully for any charging/tracking’s, replacement of bushings. (iv) Dismantling the spring charging mechanism of the VCB, checking the operations of the closing/tripping trough closing/tripping coils electrically as well as manual charging including cleaning adjustments complete for the following. (v) Checking the condition of the spring charging motor along with gear box including servicing to the motor commulator bushes, lubrication of bearing surfaces etc. (vi) Cost of additional hardware like, bolts, nuts , washers and spring washers, petroleum jelly etc, to put the breaker in serviceable condition is deemed to be included in the rates quoted. (vii) Making functional by carrying out minor repairs all the non functional circuits and indicating system like VCB Trip, CB ON, CB OFF, CB Service, Spring Charging etc. (viii) Test shall include IR, CRM and time Test.
Supply only spring charging motor suitable for operating in 240 V AC supply to be fixed in 11 KV VCB all as specified and as directed. Make : as per existing OEM as approved by GE
Supply only anti pumping relay 30V DC for VCBs all as directed and as specified.
Supply only Trip circuit coil 30V DC suitable for 11 KV Siemens/ Crompton make VCBs of all as directed and as specified.
Supply only Trip circuit coil 30V DC suitable for 33 KV Siemens/ Crompton make VCBs of all as directed and as specified.
Supply only space heaters 230 V, 80/100 W suitable for fixing inside VCB chamber along with necessary wiring for all as directed and as specified.
Supply and fix in repairs thermostat for space heaters of range 30- 110 degree suitable for fixing inside VCB chamber including wiring all as directed and as specified.
Supply and fix in repair Trip Neutral Close (TNC) Circuit breaker control Switches with 2 NO+ 2 NC contact arrangement of 25 A rating all as directed and as specified.
Supply and fix in repairs right angled cold applied cable boot suitable to cover the end connections of HT cable of size 95 Sqmm 3 core connected to 11 KV, 630 A Siemens Make 8DJ HST Model RMU all as directed and as specified.
Material and Labour for repairs to lightening arrestor Non linear type, with all fittings, transmission class, discharge capacity 10KA suitable for rated system voltage 12KV self supporting station class type complete along with connecting with the terminals of GODs with ACSR conductor of suitable size and length duly crimped with lugs all as specified and as directed.
Material and labour for taking down old deteriorated Earth chamber pit by making new concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type B1 as in cover slab 54 x 54 x 5 cm including 8mm dia MS TMT bars @ 150 mm c/c as in reinforcement with one handle for lifting made out of 8 mm dia MS bar, funnel for watering including taking down old deteriorated earth pits along with necessary excavation earth work in any type of soil complete all as specified and directed.
Supply and fix in repair digital type three phase ampere meter with programmable CT accuracy class 0.5 complete all as specified and as directed. Cat No WL131020OOOO of L&T or equivalent in
Supply and fix PVC cable duct FRLS type of size 75x75 mm including taking down damaged duct cover all as directed and specified.
Material and Labour for spray painting to Indoor/Outdoor type, Step up/ Step down transformer of capacity 50 KVA, 11KV/433V installed at different locations of Birchgunj area, after scrapping thoroughly the existing corroded paint / rust, filling the cavities with suitable filler material with one coat of silicon acrylic heat resistant paint of approved quality and colour, writing the details such as, SM/MES No. etc., complete all as specified and as directed.
All as per item No 52 but for transformer of capacity 63 KVA
All as per item No 52 but for transformer of capacity 100 KVA to 300 KVA
All as per item No 52 but for transformer of capacity 400KVA
All as per item No 52 but for transformer of capacity 1000KVA
All as per item No 52 but for transformer of capacity 2000KVA
Calibration of Micro processor based numerical relay/ differential relay by conducting primary injection on respective CTs and secondary injection tests on relays, checking of current transformer including CTR Ratio, IR Value, CT Secondary Resistance Measurement Test, rectification of defects in control wiring for proper tripping of circuit breakers through CTs, relays and tripping coils, adjustment/setting of the relay to restrict fault to upstream breakers, re-installation of the relay in circuit complete all as specified and as directed. NOTE :- (a) The contractor shall provide necessary testing kits, testing equipment, tools etc and shall also prepare the detailed test reportspanel wise duly bound and submit to the department. Rate for the kits and equipment is deemed to be included in rate quoted. Testing and turning shall be carried out in the presence of Engineer-in-Charge to the satisfaction of department, failing which payment for the above item will not be made to the contractor. No claim from the contractor be entertained on this account. (b) Rate is inclusive of setting the parameters in differential relay and connecting after carrying out necessary polarity tests etc
Supply and fix in repairs of cell 3.6V DC, lithium -1/2 AA size (ER 14250) suitable for C&S make (CSPR- V5 model) protection relay fixed in RMU all as directed and as specified.
Supply and fix in repairs hinges of door suitable for Siemens model 8DJHST RMU after removing the old broken hinges all as directed and as specified
Supply and lay control cable PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 4 core 2.5 Sqmm core incl taking down old cable all as specified and as directed.
Material and Labour for arresting leakages of transformer of capacity upto 400 KVA, 11KV/433 V from Top cover/ Bushes/ Tap changer by performing the following:- (i) Disconnecting the HT/LT side and earthing connections of the transformer. (ii) Draining out the complete transformer oil. (iii) Opening of top cover, Scraping out the old gasket packing from the top cover, dismantling the tap changer knob and removing the damaged Oil Seal/Washer/ Gasket with new one and refixing the tap changer knob and testing its functionality. (iv) Providing new gasket packing minimum 12mm thick, including nut bolt washer complete, (v) Checking for leakages from the HT/LT Bushes and replacing old gaskets/ conical washers from bushes. (v) Closing the top cover and tightening the bolts and nuts and refilling the transformer oil and checking for leakages from top cover, tap changer and Bushes. (vi) Reconnecting the HT/LT cable and earthing connections complete all as specified and as directed. Note :- (i) The contractor shall be responsible for any damage caused during the maintenance till testing and commissioning and the same shall be made good at his own expense. The decision of Engineer in charge in the regard shall be final and binding. (ii) Transformer oil required for topping up only shall be measured and paid separately. (iii) All other spares required shall be measured and paid separately. (iv) Flitration shall be carried out after the completion of job which will be measured and paid separately.
Material and Labour for Cross Arms, Bracings of any size including Supports, Clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and including applying two coats of aluminum paint cover a coat of red oxide zinc chrome primer after preparation of new steel surfaces including dismantling of existing old cross arms, bracings of any size complete all as specified and as directed.
Supply, install, testing and commissioning of Air Break switch, Gang operated, vertical type, Triple Pole, Outdoor type of capacity 200 Amps, mechanically operated, mounted on 12 Nos insulators and steel frame, with operating mechanism working from ground level complete with locking arrangements including complete with fuse mounts, Fuse carriers and fuse element having 20 Amps current rating 11000 Volts and insulators suitable for 11KV, HT, 50 Hz including GI pipes and all other materials and taking down old unserviceable AB Switch complete all as specified and as directed.
Material and Labour for synthetic insulation mat confirming to IS 15652/2006, 2.5 mm thick, suitable for 11 KV substation all as specified and as directed. Make: Jyothi or Safevolt or Burhani associate.
Material and Labour for synthetic insulation mat confirming to IS 15652/2006, 3 mm thick, suitable for 33 KV substation all as specified and as directed. Make: Jyothi or Safevolt or Burhani associate.
Material and labour for carrying out inspections & Checking on following at the main receiving Station (a) Control Panel for 33 KV VCBs Including checking functionality of Ammeter/ voltmeter/ Multifunction meter/ Annunciator/ Hooter/ TNC Switches etc - 3 Nos, (b) RTCC Panel Functional Check with OLTC Along alongwith operational check and testing- 2 Nos (c) Checking the 33 kV Outdoor PT Test 33/RT3/110V/RT3 Out Door type including PT Ratio & Secondary resistance Measurement test - 09 Nos (d) Checking all the control cables from CT/PT/Transformer at yard to control panel for continuity and making necessary connections complete for full functionality of all the relays, meters etc
Supply and fix in replacement 3 pole Power contactor of 9 Amps Rating with 1 NO and 1 NC with coil voltage 110 V AC including Add On blocks with 2+2 NO & NC including necessary wiring and DIN Rail all as directed and as specified.
Supply and replace the HT PT fuses of porcelain insulated 11/12 KV, breaking capacity 45 KA, 3.15 Amps rating capacity all as direcetd. Make : English electric/ Bussmann
Supply and fix in repair SMPS suitable for AC 230V, 50Hz as input and DC 110V, 1A as output with overload/ overvoltage and Short Circuit Protection including mounting on Panel all as directed and as specified.
Material and labour for preparation of old painted steel surfaces and applying two coats of Synthetic enamel paint over a coat of red oxide primer to all guard and MS accessories such as cross arms, bracings, ant climbing device, stay clamps etc, complete all as specified and as directed.
Supply and fix in replacement 11 KV single phase current transformer (CT's) conforming to IS-2705, VA burden - 15VA, class of accuracy - 0.5/5P-10 / PS, three core type of CT as per existing with CTR100-50/5-5-5A complete all as specified and as directed.
Supply, Fixing in replacement and Testing of PT Assembly, 11 KV Grade, Dry Type suitable for 800 A VCB, Clas0.5 capacity 100 VA, 11000 / √3 / 110 / √3 insulation level 12 / 28 / 75 KV, Voltage Factor 1.2 continuous etc. including taking down of old and unserviceable PTs from VCB Panel etc. complete all as directed by Engineer-in-charge.
Material and Labour for replacement of Dial type 100mm dia oil temp meter suitable for 100 KVA to 400 kVA,11KV/ 433V transformers complete all as specified and as directed.
Supply and fix in replacement of HV side Brass studs threaded both ends of suitable size and length including metal and rubber rings, bolts, washers etc., suitable for 100 to 400 KVA Transformer, Indoor or Outdoor type, 11KV/433V, step down of any make/model complete all as specified and as directed.
Supply and fix in replacement of LV side Brass studs threaded both ends of suitable size and length including metal and rubber rings, bolts, washer, etc., suitable for 100 to 400 KVA Transformer, Indoor or Outdoor type, 11KV/ 433 V, step down, of any make / model complete all as specified and as directed.
Supply and laying GI pipe 100mm dia light grade including all fittings complete laid in trenches/in floor, fixed on wall/ on pole for protection of underground cables all as specified and as directed by Engineer -in-Charge.
Supply and laying GI pipe 50mm dia light grade including all fittings complete laid in trenches/in floor, fixed on wall/ on pole for protection of underground cables all as specified and as directed by Engineer -in-Charge.
Supply and fix cable route indicator providing reinforced cement concrete 1:2:4, type B-1, using 20mm aggregate in precast for cable route indicator of size of 60cm height, 30cm wide & 10cm depth including two coat of synthetic enamel brown paint over a coat of primer and letter engraved & painted with synthetic enamel white paint as "LT CABLE/ HT CABLE". Indicator should be grouted 45cm underground and upper portion will be oval in shape, including necessary excavation and earth work, PCC complete and taking down old indicators all as specified and directed by Engineer-in-charge.
Material and Labour for replacing old duct cover with new mild steel duct covers with plain/ chequered plate of thickness as directed by engineer in charge with frame of angle or other section complete drilled/ welded for fixing of steel sheeting to be prepared for hanging or sliding with and including hooks complete conforming to Fe- 290 (Gde-E165) inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint incl dismantling existing cover all as directed.
Material and Labour for shifting , after disconnecting HT/LT connections of transformer upto 300 kVA 11KV/433V, shifting from any location inside Brichgunj and connecting HT/LT side to provide power supply at other location as directed by Engineer in Charge.
Supply and fix in repairs terminal clamp along with bimetallic strip 1 mm thickness made up of aluminum along with bolts, nuts and washers suitable for ACSR Conductor to be fixed on 33 KV AB Switch all as directed and as specified.
Material and labour for carrying out following testing on 33/11 KV Step down transformer of capacity 2 MVA, outdoor type of Make Schneider from a reputed Transformer Manufacturer all as directed and as specified:- (a) IR value test between HV & LV, HV & ground & LV & ground (b) Voltage Ration test (c) Magnetizing Current test (d) Winding resistance test (e) Magnetic Balance Test (f) Vector group test (g) Testing of Buchholz relay, WTI and OTI (h) Initiating the transformer Auxiliary protection Note: The Quoted rate is inclusive of the following:- (a) Removing all the electrical connections from the system by taking necessary shutdowns. (b) Submission of Test reports on Successful completion of testing. (c) Reconnecting back the electrical connections after testing.
Material and Labour for painting on old surfaces LT/HT panel/ Steel Structures by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints by spray painting machine carefully after disconnection of power supply and covering the any meters, indicators nameplates and switches to prevent from fall of paint drop on them all as directed and as specified by Engineer in Charge.
Material & Labour for earthing complete with galvanized iron earth plate electrode of size 60cmx60cm× 6mm thick, buried directly in ground vertically at a depth not less than 2.25 meters deep below normal ground level with top edge of the earth plate not less than 1.5 meters below normal ground level and surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanized iron strip of size 32X6 mm by means of bolts, nuts, check nuts and washers made up of galvanized iron or steel and protected by light grade 40mm dia galvanized iron pipe connected to main switch board or main control board and GI pipe light grade 20mm bore for watering including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and as shown in electrical plate No. 3 connected to test point terminal all as specified or indicated including taking down old earthing & testing new earthing on completion all as directed. Note:- (a) The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, PCC chamber pit, test point terminal block, 32X6 mm dia GI strip from top of earth plate upto 5 mtr above ground level and if GI protection pipe is less than 5 meters, no price adjustment shall be made.
Material and Labour for earthing complete with Copper earth plate electrode 60 x 60 cm x 3 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to Copper strip of 32x6 mm as main earthing lead (upto 7.5 m length from earth electrode to test point) by means of galvanized iron or steel bolts, nuts , check nuts & GI washers and GI tubing 40 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type B1 as in cover slab 54 x 54 x 5 cm including 8mm dia MS TMT bars @ 150 mm c/c as in reinforcement with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (Light Grade) for watering and funnel, charcoal or coal and salt in alternate layers including excavation earth work in any type of soil, RFR and removal of surplus soil complete all as specified and directed electrical plate No. 3 of SSR part - I complete all as specified and as directed.
Material and Labour for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete all as specified and directed.
Material and Labour for Earth continuity conductor or main earthing lead of 32 x 6 mm copper strip, buried in ground or fixed to wall in repair complete all as specified and directed.
Material and Labour for identifying the earth pits, improving the resistance of existing earth pit by pouring salt water in earth pit to improve resistance up to 2 Ohms and measuring the earth resistance and making record complete all as specified and as directed.
Material and Labour in replacement of Earth continuity conductor or main earthing lead of 75 x 8 mm galvanized iron strip, buried in 33/11KV yard after removing the aggregates, connecting to existing system by electric welding and GI bolts/nuts/Washers complete all as specified and directed.
Material and Labour in replacement of Earth continuity conductor or main earthing lead of 50 x 6 mm galvanized iron strip, buried in 33/11KV yard after removing the aggregates, connecting to existing system by electric welding and GI bolts/nuts/Washers complete all as specified and directed.
Supply and Fix PVC coated GI chain link fencing mesh of size 50mm x 50mm, made out of 3mm dia GI wire, with 1 mm thick PVC coating of any type, fixed to any type of standards, rails, straining bolts including provision of PVC coated GI binding wire of size 3mm dia, with 1mm thick PVC coating etc complete (weight of PVC coated GI chain link fencing shall not be less than 3.00 kg/sqm) complete all as specified and as directed. Note: (i) The rate deemed to be included the cost PVC coated binding wire. (ii) The colour of PVC coating shall be green. (iii) Cost of straining bolts is deemed to be included in the quoted rate. (iv) Weight per Sqm of chainlink fencing shall be authenticated by Engineer-in-Chage
Excavating in post holes ( Or similar holes ) Each not exceeding 0,50 Cum, getting out, returning filling ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm watering &removing surplus soil to a distance 50 mtr and making good surface.
Material and Labour PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed
Supply and fix Rolled Mild Steel sections confirming to Fe 410 - S as in fencing pole or other similar work all as directed by Engineer-in-Charge
Supply and fix MS round bars 10mm dia cut to length bent to shape required including cranking bending spirally for hopping for column hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to IS
Material and Labour preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified.
Dismantling wrought iron or mild steel work of any description
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground
Dismantling fencing wire mesh any type
KAPOOR AUTOMOBILES
Gulmarg Electrical Service
SHUSHANT ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .