Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹34.4 L+₹2.1 L (6.41%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | l3₹35.2 L+₹2.8 L (8.78%)Rejected-AOC | l3 | Rejected-AOC L3 Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 Dec 2021, 6:00 pmClosed
GE PROJECT PANAGARH
GE PROJECT PANAGARH PO PANAGARH DIST BURDWAN PIN 713420
REPAIRS TO PATH / HARDSTANDING, PLINTH PROTECTION, FENCING/GATE, INTERLOCKING TILES, MANHOLES AND CLEANING OF SEWAGE LINE AT NMS UNDER GE (P) PANAGARH
2021_MES_490129_1
8120
Open Tender
Civil Works
Item Rate
240 days
GE PROJECT PANAGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE PROJECT PANAGARH
₹70,000
Yes
13 Jan 2022
24 Nov 2021
29 Dec 2021
24 Nov 2021
27 Dec 2021
9 Dec 2021
Amount
Demolition of brick works/stone masonry work built in cement mortar including all quions, arches, pillars etc. complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Taking down cement plaster on brick walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete work, masonary etc, including taking out embedded portion and making good disturbed gound complete all as specified and as directed.
Dismantling of wrought iron or mild steel works of any description not other wise provided for etc all as specified and as directed.
Dismantling of chain link fencing of any description any type not other wise describe for complete all as specified and as directed.
M&L for fly ash brick work straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) all as specified.
All as per item No 9 above but except brick.
M&L for old brick work with Fly Ash bricks, straight or curved on plain exc 6m means radius in half brick thick walls, built in cement morter (1:4) complete all as specified.
M&L for precast cement concrete louvres and jallies, type B0 using 12.50mm graded stone aggregate, 35mm thick set in cement mortar (1:4) (measured solid),including all mouldings complete all as specified.
M&L for PCC (1:2:4) type B1using 20mm graded stone aggregate as in coping, benching etc incl necessary form works etc all as specified
M&L for rendering 10 mm thick on fair faces of brick surfaces in cement mortar (1:6) and finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick on fair faces of brick surfaces in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified.
M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregete as in surface channel or drain complete all as specified
M&L for PCC (1:3:6) type C-2 (40 mm graded stone aggregate) in foudations,filling and mass concrete. Complete all as specified
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as speciified
Add or deduct for each 25mm girth or part thereof over or under 30 cm
M&L preparation new plastered surface and applying two coat of cement base paint over a priming coat all as specified and as directed
M&L preparation old plastered surface and applying one coat of cement base paint all as specified and as directed
M&L preparation of new plastered surfaces of external walls and applying two coats of weather proof acrylic emulsion paint exterior grade (100% acrylic) of any colour over a coat of primer on prepared external surfaces of walls of any description over 10 cms width/grith etc on plastered surfacescomplete all as specified.
M&L preparation of old plastered surfaces of external walls and applying two coats of weather proof acrylic emulsion paint exterior grade (100% acrylic) of any colour on prepared external surfaces of walls of any description over 10 cms width/grith etc on plastered surfacescomplete all as specified and as directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base concrete complete all as specified
M&L for PCC (1:2:4), Type B1, 100mm thick using 20mm graded stone aggregate, concrete surface furnished evern and smooth without using extra cement as in hardstanding, path etc. complete all as specified.
M&L for 40mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in floors, finishing surface even and smooth by using extra cement all as specified and as directed.
M&L Forming contraction (dummy) joints 65 mm deep x 100mm wide filled with sealing compound grade A.
M&L 75mm thick PCC type C2 (1:3:6) type (using 40 mm graded crushed stone aggregate) as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified.
Excavation in post holes ( or similar holes) in soft/loose soil each n exc 0.50 cum getting out returning filling in and ramming complete all as specified.
M&L for providing reinforced cement concrete type B1, (1:2:4) (20mm graded stone aggregate) in pre cast fencing posts, straining or terminal posts, struts etc. for fencing average sectional area n exc 100 Sqcm with or without chamfered angles and flat, splayed, rounded or mitered tops as directed and fixed.
Use and waste of form work to sides and soffits of floor or roof beam, beam haunchings, girders, bressum mers, lintels, cantilevers, shelves including supports, overhangings, etc also splays between floors and beams etc. rough finished surfaces of concrete flat complete all as specified.
M&L RCC type B0 (1:2:4) 12.5 mm graded aggregate as in tie beams,lintel beams etc complete all as specified.
M&L precast RCC (1:2:4) B1 using 20mm graded aggregate as in cover slab set in cement mortar 1:6 complete all as specified
M&L Cement concrete type C-2 (1:3:6) (40mm graded agg) in fdn filling and mass concrete as far fixing angle irons as in fencing posts complete all as specified.
M&L Precast cement concrete solid block kerb stone of PCC (1:2:4) type B1 ussing 20 mm graded stone agg. Including weathring or chamferd Angles etc.and setting in cement morter. 1:6 complete all specified
M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade with grey cement and pigment.
M&L sand cushoning including watering and consolidation and all as specified and as directed.
Refixing of interlocking tile 60mm thick including sand cusing and taking down complete.
M&L Chequered cement concrete coloured tiles machine pressed of size 20cement morter x 20cement morter x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment over 20mm screed bed in cement morter(1:6) complete all as specified and as directed.
M&L mild steel work for posts and struts in fencing including cutting tops to shape as directed , drilling holes, notching for wire etc, flat iron fillets for recuring wire mesh, nosing to steps, hand rails, blalusters etc.
S&F mild steel frame work as in grills, gates steel door's etc with ends of bars houlderd or revited or forged in to spikes, etc and similer works confirming to FE 290 Gole E 165 etc all as specified.
S&F mild steel screw bolts 5 to 10 mm dia machine made with hexagonal or squar heads at one end and screwed the other, or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut n exc 5 cm but n exc 10 cm long.
M&L TMT steel bars 10 mm dia and over as in reinforcement cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all specified.
M&L TMT steel bars 6 to 8mm dia as in reinforcement cut to length, bent to shape required including cranking, bending spirally or hooping for chain link fencing columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all specified.
All as per item no 44 above but 5mm dia and over upto and including 10mm in stirrups, spacers and binders complete all as specified.
Supply only chain link MS galvanised fencing any size or type all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh size and type of standard, rails, straining bolts, etc including provision of binding wire all as specified and as directed.
S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified directed (each line wire to be measured)
M&L for preparation of new surface of steel and iron of any description over 10 cm width or girth, not oterwise described and applying two coat of synthetic enamel paint over a coat of red oxide, zinc chcome primer complete all as specified and as directed.
M&L for preparation of old surface of steel and iron of any description over 10 cm width or girth, not oterwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new surface of concrete of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of priming paints plaster coat complete all as specified and as directed.
M&L for preparation of old surface of concrete of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Taking out deposited sludge mechanically from sewage sump, septic tank etc,of depth n. exc. 1.5m pumping out sewage water and removed to a distance of n. exc 50M deposited sludge to excavated pit including spreading of bleaching powder @ 1.00kg per sqm ( for disfections purpose) over deposited sludge before earth spreading to excavated pit and filling earth 15 cm thick over the deposited/filled up sludge all as specified and as directed . ( Note: - Cost of earth work required for excavated pit and cost of bleaching powder are deemed to be included in unit rate.)
Taking out deposited sludge mechanically from sewage sump, septic tank etc,of depth exceeded 1.5m and n. exc 6m. pumping out sewage water and removed to a distance of n. exc 50M deposited sludge to excavated pit including spreading of bleaching powder @ 1.00kg per sqm ( for disfections purpose) over deposited sludge before earth spreading to excavated pit and filling earth 15 cm thick over the deposited/filled up sludge all as specified and as directed . ( Note: - Cost of earth work required for excavated pit and cost of bleaching powder are deemed to be included in unit rate.)
Cleaning of sewage line and manhole with green bamboo/cane stick for any dia of pipe including adequate flushing water and depositing he sludge in excavated pit and including spreading of bleaching power @ 1.00 kg per sqm (for disfecton puerpose) complete all as specified. ( Note: - Cost of earth work required for excavated pit and cost of bleaching powder are deemed to be included in unit rate.)
Cleaning /opening of blockage of WC, bathroom trap, kitchen floor trap, yard gully trap, cleaning upto 1st manhole, inspection chamber and finally cleaning and flushing water etc complete as all specified.
Cleaning and removing all scale and dirt etc, from tanks and from mouth of circulating pipes, etc of capacity exc 250 & n exc 500 litres by cleaning/disinfectcting with bleaching powder and finally washing with fresh water including writing date of cleaning by synthetic enamel paint complete as all specified.
Cleaning and removing all scale and dirt etc, from tanks and from mouth of circulating pipes, etc of capacity exc 500 & n exc 1000litres by cleaning/disinfectcting with bleaching powder and finally washing with fresh water including writing date of cleaning by synthetic enamel paint complete as all specified.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m depth for foundation of pipes and getting out in hard/dense soil all as specified and as directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m depth for foundation of pipes and getting out in soft/disintegrated rock all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm in soils all as specified and as directed.
Demolition and breaking drain pipes (salt glazed stone ware) set in cement mortar) including demolition of PCC bed and hunching to drain pipes for 150 mm bore of pipe complete all as specified and as directed.
Demolition and breaking drain pipes (salt glazed stone ware) set in cement mortar) including demolition of PCC bed and hunching to drain pipes for 200 mm bore of pipe complete all as specified and as directed.
M&L Reinforced concrete pipes class NP2 , laid and jointed complete with collars 150mm bore complete all as specified and as directed.
M&L Reinforced concrete pipes class NP2 , laid and jointed complete with collars 200mm bore complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D2 (40 mm graded stone aggregate) as in bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe all as specified and as directed.
M&L rendering 15mm thick on brick surfce in cement morter (1:4) finished even and smooth without using extra cement including water proofing compound @ 3% of weight all as specified and as directed. Note : supply only Water proofing compound will be measured and paid for separately.
Supply only Integral waterproofing compound all as specified and as directed
M&L for pre-cast cement concrete (1:2:4) type B1 ( 20mm graded stone aggregate) for man hole and drain cover slab and set in cement morter (1:4) including demolition of existing concrete cover slabs all as specified and as directed.
M&L TMT bars 8 to 10mm dia cut of length, bent to shape, hooking ends and binding with mild steel wire (annealed not less than 0.9mm dia or securing with clips all as specified and as directed.
M&L Cutting into existing manholes for connecting new drains, making good to pipe of size 150mm and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished, and forming benching as required complete all as specified and as directed.
M&L Cutting into existing manholes for connecting new drains, making good to pipe of size 200mm and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished, and forming benching as required complete all as specified and as directed.
Taking down unserviceable CI waste pipes 100mm bore from walls complete all as specified and as directed.
S&F cast iron waste pipe 100mm dia sand cast pipe in any length with or without ears with cement joints fixed to walls including taking down unserviceable pipe complete all as specified and as directed.
S&F CI 100 mm bore bends (any radius) diminishing pieces ord tapers (larger bore measured) complete all as specified and as directed.
S& F cast iron single 'Y' junctions for 100mm bore pipe laid and jointed, complete complete all as specified and as directed.
S & F cast iron cowls 100 mm dia complete all as specified and as directed.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls 110 mm bore.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls 75 mm bore.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joint ,laid in trnches or in floors 110 mm bore.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joint ,laid in trnches or in floors 75 mm bore.
S&F repairs PVC (SWR) bends in radius 110 bore provided with access door complete all as specified and as directed.
S&F repairs PVC (SWR) bends in radius 75 bore provided with access door complete all as specified and as directed.
S&F in repair PVC (SWR) double 'Y' junction of 110mm dia all as specified and as directed.
S&F in repair PVC (SWR) double 'Y' junction of 75mm dia all as specified and as directed.
S&F in repair PVC (SWR) reducer 110/75mm dia all as specified and as directed.
S&F in repair PVC (SWR) junction single T equal or unequal of 110mm dia all as specified and as directed.
S&F in repair PVC (SWR) junction single T equal or unequal of 75mm dia all as specified and as directed.
S&F in repair PVC (SWR) vent cowl110mm dia all as specified and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
SCHEDULE OF CREDIT
M/s Ajeet Kumar Singh
HIGH HILLS INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .