Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC MI CE KHURD BHUDARGAD TALUKA KOLHAPUR DISTRICT MAHARASHTRA INDIA | KOLHAPUR | MAHARASHTRA | 415101 | ₹48.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹50.7 L+₹2.4 L (4.99%)Rejected-Finance KUDITRE KARVEER KOLHAPUR | KOLHAPUR | MAHARASHTRA | 415101 | ₹50.7 L+₹2.4 L (4.99%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹48.3 L
EMD Value
₹48,254
Closing Date
21 Aug 2026, 11:00 amClosed
Executive Engineer (Works) Z P Kolhapur
Executive Engineer (Works) Z P Kolhapur
PROPOSED PRAKALP KARYALAY FURNITURE WORK UNDER I.C.D.S PROJECT IN ZILLA PARISHAD FOR KARVEER- 1 AND 2 AT KOLHAPUR ,TAL KARVEER DIST.KOLHAPUR
2026_KOLHA_1325971_1
E TENDER NOTICE NO 27/2026-27
Open Tender
Civil Works
Percentage
180 days
KOLHAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,000
₹48,254
17 Sept 2026
7 Aug 2026
24 Aug 2026
7 Aug 2026
21 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing frame work of anodised aluminium sections for suspended false ceilling consisting aluminium tee 50 milimetre X 40 milimetre weighing 0.39 kilogram per metre at 60 centimetre center to center and fixed with (15 milimetre X 15 milimetre) flanges weighing 0.119 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre fixed on wall and beams including rounding of the edges with aluminium tee of 50 milimetre X 40 milimetre weighing 0.39 kilogram per metre excetra including all labour, excetra complete. (For Ground Floor)
Item / Page No : 14 / 234
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | 1 | Square Metre | - | - |
| 2 | Providing and fixing false ceilling of 10 milimetre to 12 milimetre thick decorative boards of fibrous plaster of paris including scaffolding, if necessary, all architectural work like mouldings, cornices, coves, domes, cups as per detailed drawings and three coats of spray painting to boards, excetra complete. (excluding frame work, runners and mild steel supenders). (For Ground Floor)
Item / Page No : 17 / 235
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | 1 | Square Metre | 1 | ₹1 |
| 3 | Providing and fixing Office Table using 18 milimetre thick IS 303 grade boiling water Resistant plywood for top front vertcial, shutter,drawer front keboard CPU Stand and footrest, 12 milimetre thick IS 303 make boiling water resistnat Boiling water resistant plywood for drawer side and 6 milimetre thick IS 303 marked boiling water resistant plywood for drawer bottom. All exposed edges of plywood to be covered with teak wood lipping finished with melamine polishing with french polish. all external visible faces to be finished with 1 milimetre thick laminate and Internal Visible faces to be finished with 0.80 milimetre thick Liner laminate . One number drawer Cupboard, Keyboard and CPU Stand in plywood is to be provided to each table, including all necessary fixtures like 100 mm S.S. handles lock telescopic channel,. magnet 75 mm L Hinges, and all necessary hardware and adhesive 8 Milimetre thick plane glass with diamond polish at edges etc complete all as per detail drawing and design as per detail drawing and design including ( Before execution sample should be got approved from Enhgineer in charge)
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | - | Square Metre | - | - |
| 4 | Providing and fixing of Executive table of size 2250 milimetre long X 2100 milimetre depth X 750 milimetre height, top and gable end to be made of membrane finish with soft water fall edges and curved panel and decorated anodized section modesty panel to be made of 18 milimetre thick prelaminated particle board with polyvinyl chloride edge band, including credestal of size 1200 milimetre long X 450 milimetre depth X 650 milimetre height, to be made out of membrane finish (2 openable shutters and 3 drawers pedestal in between) as per drawing.
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | - | Square Metre | - | - |
| 5 | Providing and fixing Meeting Table of approved lenght made from 18 mm thick Marked 303 grade boiling water Resistang plywood for top and Vertical boaxes 20 milimetre wide length wise one NO and width wise three Nos with teak wood lipping on exposed edges of plywood finished with melamine polisht with french polish Top finished with 1 milimetre thick laminate and Internal surrface to be finished with 0.80 milimetre thick line laminate as per detail drawing and design including ( before execution sample shoule be got approved from Enginer in charge)
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | - | Square Metre | - | - |
| 6 | Providing and fixing stage of ht 0.25 m using 18 milimetre thick IS 303 grade boiling water resistant plywood for frame at 600 milimetre Centre to centre both the ways at top 25 milimetre thick IS 303 grade boiling waterproof plywood Top and sides to be covered with 2 milimetre thick vinyl flooring with necessary adhesive etc complete as per detail drawing and design as per detail drawing and design including . ( before execution sample shoull by got approved from Engineeer in charge)
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | - | Square Metre | 1 | - |
| 7 | Providing and fixing large Height file storage cupboard made from 18 mm thick boiling water Resistant plywood IS 303 grade of approved make for bottom, top vertical,s shelves and shutters and 12 mm thick boiling water Resistant plywood IS 303 grade of approved make for back side 19 mm x 10 milimetre teak wood leaping for all exposed faces of plywood with melamine polish with french polish external faces of plywood to be finished with 1 mm thick laminate and internal faces of plywood is finished with 0.80 mm thick liner laminate. All necessary hardware like 75 mm long. L hinges,100 mm stainless steel finish handles, lokcl, magnet 100 mm ss tower bolt etc are included in the ite,. 0.45 deep as per detail drawing and design as per detail drawing and design including ( before execution sample shoull by got approved from Engineeer in charge)
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | 1 | Square Metre | - | - |
| 8 | Providing & fixing Side storage unit for all types made of 18 mm thick Commercial plywood ISI 303 at top, bottom, side & shutters also & T.W. lipping & molding of edges. Exposed faces to be finished with 1 mm thick Laminate & internal surfaces with French spirit polishing. Including all necessary hardwares such as brass hinges, handles, locks, etc. complete.
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | 1 | Square Metre | - | - |
| 9 | Providing and fixing 75 mm thick Partition made of frame 18 mm tbick IS 303 grade boiling Water Resistant plywood of 36 mm thick and 50 mm wide with spacing of 600 milimeter center to center both vertically and horizontally frame shall be covered on both side with 8 milimetre thick IS 303 grade boling water Resistant plywood and 12 milimetre thick glass with itching process fixed with the help of teak wood lipping or required size finished with melamine polish with french polish. The plywood covered is finished with 1 milimetre thick laminate including all hardware fixtures etc complete as per detail drawing and design as per detail drawing and design including ( before exectuion sample should by got approved from Engineer in charge)
Non-Dsr Item
Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge. | - | Square Metre | - | - |
| 10 | PRIVIDING AND FIXING MODULAR ACOUCTICAL WOODEN WALL PANELLING: Of nominal width 100 / 150mm, having80mm wide panel with 20mm reveal having a thickness of 15mm thickness and length 2400 mm. The panel shall be made of a Moisture resistant fibre board substrate having a minimum density of 595 Kg/m3 with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut) and a melamine balancing layer on the reverse side. The panel shall have 0.7mm PVC edge banding along the length side with a similar finish as that of the face. The back of the panel shall have a black acoustic felt to cover the reveal of 20mm to attain an NRC of 0.4 for 150mm. / 0.5 for 100mm. module (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423. The panels shall provide a Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. The back of the panels shall be profile-grooved to receive 3600mm special main beam carrier with integrated factory fitted clips for installation. SUSPENSION: The panels shall be upward mounted on 24 mm wide T - section flanges having rotary stitching along the length of the beam with a web height of 43mm. The Main Beam shall have integrated (factory fitted) locking clips installed at 100 / 150mm centre to centre distance. The deflection loading of the main beam tested as per ASTM C635 (Deflection limit less than L/360) shall be at least 21.4kg/m. The end details of the main beam shall be made of pre hardened steel and fixed to the ends with 3 point fixing. All main beam to main beam connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. Installation should be carried out as per Manufacturer recommended procedure. The grid shall be installed with suspension system of Manufacturer make.The panel & grid system used together shall carry a 1 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The panel & grid shall have the manufacturers name embossed/printed on itself. The supply shall be backed by a Manufacturer Test Certificate. CEILING INSTALLATION:Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centre to centre. Mount the wall angle around perimeter at desired height. Install the main beam with factory fitted locking clip at a level 16mm above the wall angle level. Main beam to be supported from the structure with 1st suspension not more than 300mm from the wall and distance between suspensions to be less than 900mm centre to centre. Each main beam are to be place at 600mm centre to centre with the 1st main beam at not more than 100mm from the wall. Install the panels one-by-one by inserting the profile-groove at the back of the panel in the clips fitted on the main beam. Use a wood splice accessory provided by Manufacturer to join planks. Continue installing rows of planks till the actual length/width is achieved. Place the border panels on the wall angles for a finished visual. Finish the edges using the edge banding tape to cover the cut edge of the panel provided by Manufacturer.SUSPENSION SYSTEM accessories manufactured and supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners.WALL INSTALLATION: An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before theinstallation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer‘s
Item / Page No : 41 / 477
Additional Specifications : The work shall be done as per instructions of Engineer in charge. | 1 | Square Metre | 1 | ₹1 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
SBD_2026_27.pdf
Tender Documents • 2.99 MB
BOQ_2270915.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .