| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.7 L+₹3.9 L (11.6%)Rejected-Finance JAISALMER | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹39.6 L+₹5.9 L (17.4%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹40.0 L+₹6.3 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Not being lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
10 Mar 2022, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR TO B/R ASSEST MISC B/R WORKS INCLUDING REPAIR TO SUNKEN SLAB, JOINERY, LEAKAGE SEEPAGE IN CERTAIN OTM ACCN AT MIL STN JAISALMER
2022_MES_507476_1
8165/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹52,000
Yes
31 Mar 2022
11 Feb 2022
12 Mar 2022
11 Feb 2022
10 Mar 2022
24 Feb 2022
Amount
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring / hardstanding & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M& L for PCC 50mm thick (1:3:6) type C1 (using 20mm graded stone aggregate) laid in alternative as in plinth protection including finished the surface even and fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
S & F chequered cement concrete tiles 20cm X 20 cm X 25mm thick with grey cement and pigments,set jointed in neat cement slurry as in floors/path etc laid over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic tiles, coloured, exterior grade 300 x 300 x 10mm (Endura from Johnson or equivalent) laid over and including screed bed in CM 1:6, 15 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and roughening of exc concrete surfaces complete all as specified and directed by Engineer-in-charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing, removing serviceable tiles) complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in subbase of floors & finishing the surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, joint free non skid tiles laid over and including screed bed or bedding layer 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for vetrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.38sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement laid over and including 15mm thick screed bed in CM 1:6 all as directed (size 600mm to 600mm) complete all as specified and directed by Engineer-in-charge.
M & L non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in coloured cement to match the tiles, laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M & L glazed ceramic coloured tiles (450x300mm)x 7mm thick joint free in dado/skirting set and jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over and including 10mm thick rendering in CM 1:4 of backing coat etc complete all as specified and directed by Engineer-in-charge.
M&L for special treatment for sunken portion of WCs/bath and toilet executed in the following stages :- Stage 1:- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc complete. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr Fixit or its equivalent make as approved in the proporation/quantity all as per manufacturer's instrucitons. Stage 3:- Apply two coats of water proofing elastomeric liquid membrane of Dr Fixit or by brush application of STP or its equivalent make as approved (The surface after painting one coat shall be allowed to dry for 8 hours before application of next coat) all as per Manufacturer's instructions. Stage 4: Rendering 10mm thick in CM 1:3 mixed with integral water proofing chemical of Dr Fixit or its equivalent make as approved in the proportion/quantity all as per Manufacturer's instructions.
Item No. 13.00 Contd... Stage 5: All CI joints shall filled with mixture of cement fine sand and shalicrete R of STP Ltd or integral water proofing chemical of Dr Fixit or its equivalent make as approved all as per Manufacturer's instructions. Stage 6: Making holes in wall and fixing 600mm long 20mm dia medium grade GI spout for draining the surplus water if any. Stage 7: Carry out ponding test for 72 hours to ensure water tightness of rapaired sunken portion. Stage 8: Sunken floor shall be filled with lean cement concrete PCC (1:5:10) type E2 (using 40mm graded stone aggregate) after satisfactory passing of above mentioned treatment by Engineer-in-charge.
Taking up or down steel tubing and connections of following size all as directed by Engg-in- Charge :-
(a) 15 mm bore
(b) 20 mm bore
S&F GI tubing (ISI) marked) medium grade with all fitting and fixed complete to wall ceiling or laid in floors of following sized :-
(a) 15 mm bore
(b) 20 mm bore
Refixing only steel tubing including cleaning and connections in new or old position (Wall, ceiling, floors etc) of the following size :-
(a) 15 mm bore
(b) 20 mm bore Note :- Serviceable material obtained from Ser item No. 14 shall be used for fixing.
S & F in repair CP brass Towel rail 20mm dia, D type, 60 cm long complete fixed in wall with screws complete all as specified and directed by Engineer-in-charge.
S&F in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-charge.
S&F in repair Swivel shower rose 75mm size with arm 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and directed by Engineer-in-charge.
S&F in repair CP grating (with & without hole) for Nahani trap and floor trap of size 100 mm dia complete all as specified and directed by Engineer-in-charge.
S&F in repair PVC connection pipe for WHB, cistern, gysers etc of size 15 mm dia and 450 mm long complete all as specified and directed by Engineer-in-charge.
S&F in repair PVC seat cover black/white closed pattern with flat bottom and mild steel CP or aluminium hinging device complete all as specified and directed by Engineer-in-charge.
S & F in repair Vitreous china wash down water closet pan (Pedestal pattern), white (EWC)with necessary P/S Trap and complete all as specified and directed by Engineer-in-charge.
S&F in repair of vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with 'S' or 'P' trap (excluding flushing cistern and flush pipe) size 580mmX440mm white complete all as specified and directed by Engineer-in-charge.
S&F in repair PVC low level white flushing cistern syphonic action type 10 ltrs capacity incl flush pipe 32 mm dia incl PVC connection 450 mm long and complete all as specified and directed by Engineer-in-charge.
S&Fin repair wash hand basin vitereous china flat back size 550 x 400 mm white incl CP waste coupling waste pipe brackets complete all as specified and directed by Engineer-in-charge.
S&F in repair CP bib taps 15 mm dia of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair pillar taps 15 mm bore cast copper alloy with capstan head chromium plated screwed down high pressure with or without 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed complete all as specified and directed by Engineer-in-charge.
S & F in repair 15 mm Stop valve fancy type cast copper alloy chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster from brick or concrete wall surfaces including raking out joints, hacking for key scrubbing down with water complete all as specified and directed by Engineer-in-charge.
M&L rendering 15 mm thick on brick or concrete surface in CM 1:6 and surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement morter 1:4 on fair face of brick wall or concrete surfaces, finished even & fair complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces and apply two coats of cement based paint over a coat of primer complete all as specified and directed by Engineer-in-charge.
M&L preparation of new plastered surfaces of any description and apply two coats of oil emulsion distemper over a coat of putty on wall for making uniform smooth surface and primer distempering complete all as specified and directed by Engineer-in-charge.
Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 finished the surface with existing specification complete all as specified and directed by Engineer-in-charge.
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M S square tubes, S&F in opening as per specification & drawing given in SSR 2020.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with single piece extruded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of single piece extruded PVC profile for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified & directed by Engineer-in-charge.
S & F aluminium anodized tower bolt 150mm size complete all as specified and directed by Engineer-in-charge.
S & F Butt hinges Aluminum 100 mm type C21 complete all as specified and directed by Engineer-in-charge.
S & F aluminium handle 125 mm cast type anodized complete all as specified and directed by Engineer-in-charge.
Resecuring without taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-charge.
Resecuring or easing & adjusting without taking down shutters of any description n exc 1 sqm each complete all as specified and directed by Engineer-in-charge.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 and n exc 2 sqm each complete all as specified and directed by Engineer-in-charge.
S&F in repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-charge.
S&F in repair MS powder coated drapery rod 25mm dia decorative manner all as per sample complete all as specified and directed by Engineer-in-charge.
S&F in repair, 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete including welding if required for fixing in case of pressed steel chowkat complete all as specified and directed by Engineer-in-charge.
S & F in repair looking mirror 600x450mm with PVC sheet frame and back supported with 6mm thick AC building board or plywood sheet complete all as specified and directed by Engineer-in-charge.
S& F in repair of galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples fixed complete all as specified and directed by Engineer-in-charge.
Hacking out old broken glasses (any thickness, size, quality or description) from steel/wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each panes complete all as specified & directed by Engineer-in-charge. Note :- To be fixed at any floor level not more than triple storey.
S&F in repair, aluminium (Die cast) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete all as specified & directed by Engineer-in-charge.
S&F for floor spring double action hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of MS heavy duty complete all as specified & directed by Engineer-in-charge.
S&F in repair, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable rolling shutter of any description any size height upto 4 mtrs complete all as specified and directed by Engineer-in-charge.
S&F steel rolling shutters of 1.25 mm thickness laths without ball bearing (push pull or manual type) as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position complete all as specified and directed by Engineer-in-charge.
All as per item No. 55.00 above but gear operated type with bevel gear box and crank handle complete all as specified and directed by Engineer-in-charge.
S&F ball bearing for rolling shutters complete all as specified and directed by Engineer-in-charge.
Dismantling (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified & directed by Engineer in charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not othervise provided for complete all as specified and directed by Engineer-in-charge.
S & F Joist, channel, angel or tee sections, fixed independently, without connecting plates etc complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable Collapsible steel gates of any description any size height upto 4 mtrs complete all as specified and directed by Engineer-in-charge.
S&F of Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed by Engineer-in-charge.
Dismantling Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed by Engineer-in-charge.
M&L for 35mm thick precast cement concrete louvers and jallies type C-0 (1:3:6) using 12.50mm graded aggregate (measured solid), including all mouldings but excluding frame, set in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
M & L Providing PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings and bonders (for stone walling) including necessary form work complete all as specified & directed by Engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed by Engineer-in-charge.
S&F anodised aluminium snap grid frame work 600x600mm for false ceiling and hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long complete all as specified and directed by Engineer-in-charge. Note :- Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm.
S&F of 12 mm medium density fibre board, exterior grade, fixed to timber frame work with screws complete all as specified and directed by Engineer-in-charge.
Taking down old unsv LT Cable of any size etc complete all as specified and directed by Engineer-in-charge.
Supply & Laying XLPE insulated, screended, PVC bedded, galvanised steel strip or wire armoured electric cables with aluminium conductor, cross sectional area 25 Sqmm x 4 Core complete all as specified and directed by Engineer-in-charge.
Supply & Laying XLPE insulated, screended, PVC bedded, galvanised steel strip or wire armoured electric cables with aluminium conductor, cross sectional area 16 Sqmm x 4 Core complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or soft/dis integrated rock for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out complete all as specified & directed by Engr-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified & directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed by Engr-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required covercomplete all as specified and directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB, 63 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 100 Amps, four pole,16 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 125 Amps, four pole, 16 KA, 415 volt with fixed thermal maganetic release complete all as specified and directed by Engineer-in-charge. Note: ICS = ICU 100%.
Material and labour for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and existing paint complete surface up to pole top including connected accessories and apply with two coats of synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos), including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc complete all as directed by Engineer-in-charge.
S&F in repair High Mast Light Integral type LED Flood Light of 200 Watt with 10KV Surge Protection IP-66 complete for high mast light aaplication complete with fixing arrangment & bolts acomplete all as specified and directed by Engineer-in-charge. Note :- T&P required to roll down the high mast light from 15/16 Mtrs height to ground level for repair will be the responsibility of the contractor. No extra payment will be made by the contractor.
Labour only for attending street light complaints and rectifying the faults viz non ops & flickering of street light, Cable or service wire damage, earth leakage & electric shock in street light poles & panel, hanging or bending of street light etc up to entire satisfaction of Eng-in-Charge including all necessary petty items like lugs, nut, bolts, screws and any type of tool required. Note:- (i) Group of complaints for one feeder will be consider as one job. Complaint slip will printed and supplied by contractor in prescribed format as specified at the time of commencement of contract as directed by Engr-in-Charge. (ii) Contractor has to arrange aluminium ledder suitable type & vehicle for attending the complaints at his cost. No extra payment will be paid by department
S&F in repair, Junction Box for street light made of PVC box including MCB 10Amps - 01 No and terminal 3 Nos for single phase and neutral on porcelain based insulator with locking arrangement fixed to pole with MS clamps of suitable (20mmx3mm) with nuts, bolts & washer including painting of MS clamp complete all as specified and directed by Engineer-in-charge.
S&Fcable 2.5 sqmm Two core, Copper conductor, 1100 volts grade including taking down existing cable complete all as specified and directed by Engineer-in-charge.
S&F in repair Lithium based energy efficient Integrated solar street light of 20 watt in single FRP body with duly polyurenthane coating encases with monocrystalline solar PV panel of 45Wp, Lithium battery 11.1/12.8 Volt, 24.2Ah with inbuit BMS, IP 65, High brightness W-LED (160-180 Im/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K-6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor,Dusk to dawn operation weight not more than 10-12 KG with adjustable MS Clamp suitable for existing pole/wall mounting etc complete all as specified and directed by Engr-in-Charge.
Note for item No. 86.00 :- Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & TOHS complaint.
S&F in repair 1x60 Watt LED Street Light Fitting including all electrical connection complete all as specified and directed by Engineer-in-charge.
S&F in repair 1x70 Watt LED Street Light Fitting including all electrical connection complete all as specified and directed by Engineer-in-charge.
S&F in repair 1x90 Watt LED Street Light Fitting including all electrical connection complete all as specified and directed by Engineer-in-charge.
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings complete all as specified and directed by Engineer-in-charge.
Supply & laying GI pipe light grade of dia 40 mm laying in road and along with poles for cable protection complete including taking down old pipe complete all as specified and directed by Engineer-in-charge.
S& laying GI pipe light grade of dia 25 mm laying in road and along with poles for cable protection complete including taking down old pipe complete all as specified and directed by Engineer-in-charge.
Supply only the following parts for LED fittings :-
(a) Driver 45 W
(b) Driver 60 W
(c) Driver 70 W
S&F in repair advance microcontroller and real time clock base astronomical timer panel suitable for 3 phase 415v,AC having 8 bit micro controller with inbuilt battery,16 character two line LCD display, input isolator 125 Amp 4 pole and 3 Phase output with 06 Nos, 32Amps MCB SP and with complete copper conductor power wiring of suitable size, contactor 63 Amp 4 Pole-03 Nos, inside 2mm(16/18guage) thick feeder panel duly power coated complete with 40X40X5mm 45CM height angle iron structure with PCC complete suitable for 30 KVA load and suitable for staggering each phase complete all as specified and directed by Engineer-in-charge.
S&F in repair Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors complete all as specified and directed by Engineer-in-charge.
S&F in repair Contactor Coil suitable upto MNX 40 type complete with taking out old burnt coil and replacing with new coil complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 3 pole Power Contactors confirming to IS/IEC-60947-4-1 complete for upto 55 Amp rating MNX type (40) complete all as specified and directed by Engineer-in-charge.
JASOL MAA ENTERPRISES
Leelashah Enterprises
Dadhich Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .