Executive Engineer EDD leh
Office of the Executive Engineer EDD Leh
Supply, Installation, Testing and Commissioning for Shifting DT frame along with HT Line at various locations of Nubra section under Improvement of HT/LT Line of UT Capex 2021-22.
2021_PDNRE_3751_1
NIT No 65 of ED Leh of UT Capex 2021-22
Open Tender
Electrical Works
Works
45 days
LEH
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Payable To Executive Engineer EDD Leh
Exempted
13 Dec 2021
16 Jul 2021
3 Aug 2021
17 Jul 2021
2 Aug 2021
17 Jul 2021
Amount
DT Substation
Gapless Surge Arrestor,9 kV, 10kA, LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
50 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps (as per REC Standard)
Galvanized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
LT Distribution Box Out door mounting type for 3 Ph 25kVA DTR having 40A TPN isolator, 40A HRC fuse (incomer) and 3 Nos 40A SP MCCB (outgoing)
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
Sundry items like aluminium lugs, Jumpers, binding Tape etc
Chain link Fencing for Transformer with dimension (10'x10'x6') using Angle Iron 40x40x6mm with mesh wire of 2"x2" having door facility of dimension (3'x6')
Dismentalling,carriage and reinstallation of existing xmer to new ST frame (200 Mtr Aprx)
Shifting of HT Line
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
30 mm² ACSR Conductor (Single conductor length)
GI Channel X-arm including clamps and braces for DP (80Kg/DP) (as per REC Standard)
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole including muffing 0.2Mtr above the ground level plaster and curing of concrete as per drawing/Annexure "D"
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Galvanised channel 8ft 75x40x6mm (4 Nos.) for link Set.
11KV Link Set 200Amp as per REC Standard.
Dismentalling of 8 Mtr ST Pole , carriage(200mtr) & re-erection at the new location
Dismentalling of 0.03 ACSR conductor and re-stringing of the same on the newly errected ST pole
ROYAL HAYAN CONSTRUCTION AND COMPANY
NAMDRUK ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .