Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.5 LAccepted-AOC | ₹64.5 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹95.3 LRejected-AOC | ₹95.3 L | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹1.0 CrRejected-AOC | ₹1.0 Cr | L3 | Rejected-AOC L3 Bidder |
| 4 | L4₹2.6 CrRejected-AOC | ₹2.6 Cr | L4 | Rejected-AOC L4 Bidder |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-1. GST Registration certificate not uploaded.
2. Form 3B GST latest quarter not uploaded.
3. A Class registration card not uploaded. |
| Sl No | Description | Qty | Unit | M/S R R ELECTRICAL SERVICES L2 | GZS INFOTECH PRIVATE LIMITED L1 | AL GAFFAR ELECTRICALS L3 | M/S Northern Electricals L4 |
|---|---|---|---|---|---|---|---|
| 0.00REPLACEMENT OF ELECTRICAL ITEMS | |||||||
| 1.00Replacement and fixing of Earthing of following Pole Earthing Complete by GI Rod 40mm 3.0 mtr long through GI Strip 25X3 MM as per relevant IS. | |||||||
| 1.01 | 11/9/8 Mtr Pole Earthing | 1 | No | 1,500 ₹1,500 | 1,000 ₹1,000 | 200 ₹200 | 2,200 ₹2,200 |
| 2.00SITC/REPLACEMENT of 11 KV (HT) CABLE (UNDERGROUND) | |||||||
| 2.01 | 11kV, Single core 630 mm² Aluminium Round wire Armoured XLPE Cable , FRLS | 1 | Mtr | 2,400 ₹2,400 | 1,800 ₹1,800 | 1,500 ₹1,500 | 2,550 ₹2,550 |
| 2.02 | 11kV, Single core 400 mm² Aluminium Round wire Armoured XLPE Cable , FRLS | 1 | Mtr | 1,600 ₹1,600 | 1,400 ₹1,400 | 1,200 ₹1,200 | 2,250 ₹2,250 |
| 2.03 | 11 kV, Single core 300 mm² Aluminium, Round wire Armoured XLPE Cable , FRLS | 1 | Mtr | 1,500 ₹1,500 | 1,100 ₹1,100 | 1,000 ₹1,000 | 1,850 ₹1,850 |
| 2.04 | 11 kV, Single core 120 mm² Aluminium Round wire Armoured XLPE Cable, FRLS | 1 | Mtr | 1,000 ₹1,000 | 800 ₹800 | 650 ₹650 | 1,450 ₹1,450 |
| 2.05 | 11kV, Single core 185 mm² AluminiumRound wire Armoured XLPE Cable , FRLS | 1 | Mtr | 1,200 ₹1,200 | 950 ₹950 | 700 ₹700 | 1,220 ₹1,220 |
| 3.00SITC/REPLACEMENT of 11 KV Heat Shrinkable Cable Termination Kits (Indoor/Outdoor) | |||||||
Updated dates
Tender Value
₹1 Cr
EMD Value
₹2 L
Closing Date
31 Dec 2025, 4:00 pmClosed
Chief Engineer Srinagar Smart City Ltd
1st Floor Budshah Building Lal Chowk Srinagar
Maintenance- Repairs- Replacement of Electric items for various projects executed under Srinagar Smart City Limited for a period of 2 years.
2025_SSC_298693_1
E-NIT No. 57-SSCL of 12-2025-26, Dt. 19/12/2025
Open Tender
Civil Works
730 days
Srinagar City, Various Locations
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
CEO Srinagar Smart City Ltd
₹2 L
Yes
2 Feb 2026
19 Dec 2025
1 Jan 2026
19 Dec 2025
31 Dec 2025
19 Dec 2025
MAINTENANCE/REPAIRS OF ELECTRICAL ITEMS
Replacement and fixing of Earthing of following Pole Earthing Complete by GI Rod 40mm 3.0 mtr long through GI Strip 25X3 MM as per relevant IS.
11/9/8 Mtr Pole Earthing
11kV, Single core 630 mm² Aluminium Round wire Armoured XLPE Cable , FRLS
11kV, Single core 400 mm² Aluminium Round wire Armoured XLPE Cable , FRLS
11 kV, Single core 300 mm² Aluminium, Round wire Armoured XLPE Cable , FRLS
11 kV, Single core 120 mm² Aluminium Round wire Armoured XLPE Cable, FRLS
11kV, Single core 185 mm² AluminiumRound wire Armoured XLPE Cable , FRLS
SITC/REPLACEMENT of 11 KV Heat Shrinkable Cable Termination Kits (Indoor/Outdoor)
Replacement ofcable Termination Kits (Indoor/Outdoor) Heat Shrinkable Type along with necessary accessories to accommodate for single core 630, 400, 300, 185 & 120 sqmm complete with all kit contents including earth contuinity along with 3 No Crimping type aluminium, lugs of suitable capacity.
SITC/REPLACEMENT of LT XLPE Armoured Single Core,1.1kV Grade (UNDERGROUND)
Replacement of 630mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type ( under ground )
Replacement of 400mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type ( under ground )
Replacement of300mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (under ground )
Replacement of 240mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (under ground )
Replacement of 185mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type ( under ground )
Replacement of 120mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type ( under ground )
Replacement of 95mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type ( under ground )
Replacement of 70mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( under ground )
SITC/REPLACEMENT of Heat Shrinkable ( LT) Termination Kits for Single Core Cable of following Sizes.
End termination for 1C 25-50 mm²
End termination for 1C 70-150 mm²
End termination for 1C 185-300 mm²
End termination for 1C 400-630mm²
SITC/REPLACEMENT of Heat Shrinkable Straight Through Cable Jointing Kit for 1.1KV LT of following sizes:
Straight Through Jointing Kit for 25-50 mm²
Straight Through Jointing Kit for 70-150 mm²
Straight Through Jointing Kit for 185-240 mm²
Straight Through Jointing Kit for 300-400 mm²
SITC/REPLACEMENT of Heat Shrinkable Cable LT Termination Kit for 3.5 Core 1.1KV of following sizes:
Replacement of including labour,carriage, freight, taxes, duties etc of Cable Termination Kits (Indoor/Outdoor) Heat Shrinkable Type along with necessary accessories to accommodate for 630, 400 & 185 sqmm 3.5 Core KV XLPE (E) Aluminium cable complete with all kit contents including earth contuinity along with 3 No Crimping type aluminium, lugs of suitable capacity including making of joints etc.
SITC/REPLACEMENT of LT thimbles compatible
Replacement of Aluminum LT thimbles compatible for 630 mm LT Cable
Replacement of Aluminum LT thimbles compatible for 400 mm LT Cable
Replacement of Aluminum LT thimbles compatible for 300 mm LT Cable
Replacement of Aluminum LT thimbles compatible for 240 mm LT Cable
Replacement of Aluminum LT thimbles compatible for 185 mm LT Cable
Replacement of Aluminum LT thimbles compatible for 120/95/70/50/25 mm LT Cable
SITC/REPLACEMENT of 3½ Core Cable,1.1kV Grade, Armoured, XLPE CABLE
Replacement of 630mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 400mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 300mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 240mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 185mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 120mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 95mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 70mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 50mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
Replacement of 35mm² 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
SITC/REPLACEMENT of 4 core 1.1KV ARMOURED XLPE CABLE
Replacement of 25mm² 4 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS ( under ground )
SITC/REPLACEMENT of 2 core 1.1KV ARMOURED XLPE CABLE
Replacement of LT 25/16 Sqmm 2 Core AL XLPE Armoured cable to be carried through conduit/pipes/channels including Lugs, crimping(Underground)
Providing and Fixing of Insulation tape (red / yellow / black)
Earthing of Octagonal Pole Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI Strip (25x3)mm
Replacement and fixing of following size PVC insulated multistrand flexible copper wire for service connections:Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Complete Job as per directions of Engineer In Charge)
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
MCCBs
Replacement of MCCB ‐ 200 Amps,36 kA,4P adjustable
Replacement of MCCB ‐ 100 Amps,36 kA,,4P adjustable
Replacement of MCCB ‐ 160 Amps,36 kA,,4P adjustable
Replacement of MCCB ‐ 250 Amps,36 kA,,4P adjustable
Replacement of MCCB ‐ 400 Amps,36 kA,,4P adjustable
Replacement of MCCB ‐ 630 Amps,36 kA,,4P adjustable
Replacement of MCCB ‐ 1000 Amps,36 kA,,4P adjustable
HDPE & GI PIPES
Replacement of HDPE Pipe Outer Dia 180 mm Inner Dia 152 mm with necessary joints including excavation ,Back filling, laying and restoration of surface to its original shape
Replacement of HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm with necessary joints including excavation ,Back filling, laying and restoration of surface to its original shape
Replacement of HDPE Pipe Outer Dia 120mm Inner Dia 108 mm with necessary joints including excavation ,Back filling, laying and restoration of surface to its original shape
Replacement of HDPE Pipe Outer Dia 90mm Inner Dia 78 mm with necessary jointsincluding excavation ,Back filling, laying and restoration of surface to its original shape
Replacement of HDPE Pipe Outer Dia 50mm Inner Dia 38 mm with necessary jointsincluding excavation ,Back filling, laying and restoration of surface to its original shape
Replacement of 40 mm GI pipe with required number of collars for road crossing incl. Termination points (1.5") ( under ground )
Replacement of 150 mm GI pipe with required number of collars for road crossing incl. Termination points (6") ( under ground )
Replacement and fixing of 32 A rating /240/415V,10 KA , C Curve, SPN MCB
Replacement and fixing of 63 A rating /240/415V,10 KA , C Curve, DP MCB
BUSBAR
Replacement of Aluminium Busbar Strip (3 Phase Set) of capacity 250 Amp
Replacement of Aluminium Busbar Strip (3 Phase Set)of capacity 400 Amp
Replacement of Aluminium Busbar Strip (3 Phase Set) of capacity 630 Amp
Replacement of Aluminium Busbar Strip (3 Phase Set) of capacity 1000 Amp
Laying of HT/LT underground XLPE Armoured Cable using HDD method inccluding 110/150mm HDPE PLB DUCT
REPLACEMENT OF ELECTRICAL ITEMS
630 KVA Distribution Transformer
400 KVA Distribution Transformer
250 KVA Distribution Transformer
100 KVA Distribution Transformer
63 KVA Distribution Transformer
Maintenance/Repairs/Fixing of fabricated GI Angle/Channel/Flat/Pole Collars.
Maintenance/Repairs/Fixing of Galvanised nuts and bolts.
Maintenance/Repairs including loading/unloading, transportation, carriage of following sizes of Distribution Transformer at site.
100 Sqmm ACSR (Dog)
50 Sqmm ACSR (Rabbit)
30 Sqmm ACSR (Weasel)
Maintenance/Repairs including loading/unloading of AB (HT) CABLE of following sizes:
50 mm² AB (HT) Cable (3x50+1x70 mm²) XLPE(11 kV, 3C +Earth)
70 mm² AB (HT) Cable (3x70+1x95 mm²) XLPE(11 kV, 3C +Earth)
95 mm² AB (HT) Cable (3x95+1x95 mm²) XLPE(11 kV, 3C +Earth)
120 mm² AB (HT) Cable (3x120+1x95 mm²) XLPE(11 kV, 3C +Earth)
Maintenance/Repairs of Mid Span Straight Through Jointing Kit for 11 kV ABC of following sizes:
11 kV ABC 50-95mm² Straight Through Jointing Kit (3 Core)
11 kV ABC 120-185mm² Straight Through Jointing Kit (3 Core)
11 kV ABC 240-300mm² Straight Through Jointing Kit (3 Core)
Maintenance/Repairs of Heat Shrinkable Outdoor Cable Termination Kit for HT/LT ABC of following sizes:
11 kV ABC 70-95 mm² Outdoor Cable Termination Kit
11 kV ABC 120 mm² Outdoor Cable Termination Kit
11 kV ABC 150-185 mm² Outdoor Cable Termination Kit
11 kV ABC 240-300 mm² Outdoor Cable Termination Kit
Maintenance/Repairs including loading/unloading of AB (LT) CABLE of following sizes:
50 mm² AB (LT) Cable ( 3x50 + 1 x 16 + 1 x 35) mm² XLPE (1.1kV, 3+1 C, Al)
70 mm² AB (LT) Cable (3 x 70 + 1 x 16 + 1 x 50) mm² XLPE (1.1kV, 3+1 C, Al)
120 mm² AB (LT) Cable (3 x 120 + 1 x 25 + 1 x 95) mm² XLPE (1.1kV, 3+1 C, Al)
Maintenance/Repairs of Straight Through Cable Jointing Kit for LT ABC of following sizes:
50 mm² AB (LT)Straight Through Cable Jointing Kit
70 mm² AB (LT)Straight Through Cable Jointing Kit
120 mm² AB (LT)Straight Through Cable Jointing Kit
Dismantling
Dismantling, Stacking of 9/8 mtr ST Poles and transportation back to Divisional Store as per the instruction of electrical incharge.
Dismantling of 0.03/0.05/0.1 ACSR Conductor and transportation to Divisional Stores (servicible)
Servo Voltage Stabilizer
Maintenance/Repairs including loading/unloading, carriage, transportation of Packaged Substation - 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 100kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with all interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications:A) 3 way Non - Extensible RMU (breaking capacity 25kA for one second) with 2no. 630 A load break switch and 1 no. 200 A tee off with SF6 Circuit Breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T's etc. to complete as required to entire satisfaction of Engineer-in-charge.B) 1 no. 11 kV / 433V, 400 kVA three phase,Copper Wound Level-2 DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings.C) 1 No. 433V, 800A LT devices with PVC sleeved Aluminium Busbars.D) One no. 4pole 630A, 25kA MCCB with microprocessor Based Release.E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400 Amp.each. Including 3phase 4 wire energy meter. F) Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. umarmoured XLPE Cable 95 kVp. G) The provision for solid connection with Aluminium strips with Heat Shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB .
Maintenance/Repairs including loading/unloading, Carriage, Laying, stringing and binding of conductor including joints with PG clamps of required following size of ACSR Conductor (0.1 /0.05/ 0.03)
Maintenance/Repairs including loading/unloading, transportation, carriage of 50 KVA, 3-Phase oil cooled Servo (Complete Job)
Compact Substation
Maintenance/Repairs including loading/unloading, carriage, transportation, of 4 way type,two isolators and two Circuit breakers 11 kV, Ring Main Unit ,SF6 Insulated, out-door type, Extensible type,breaking capacity 25 kA for one second with SF6 Circuit Breaker / VCB self powered with O/C + E/F Relay comprising of a) 11kV 630 Amp Motorised Isolator including earthing Switches with making capacity 52kA, having mechanical ON/OFF, earth indications with fault current Indicator.b) 11kV ,400 Amp motorised Spring operated, Circuit Breakers with earthing switches, connecting the RMU to Supply transformer. c). Copper Bus Bar of 630 Amp rating.d). 1 No Numerical Aux. Powered relay having non directional O/C and E/F protection (for each Ciruit Breaker).d). The Circuit Breaker enclosures shall be outfitted with a communicable-type numerical (feeder protection) relay, i.e., one for each Circuit Breaker. The relay shall also interface via an RS 485 port in order to send, as a minimum, real-time phase current , readings using the MODBUS protocol.e) Incomming Isolator having FPI with electrical reset Contact /facility.f) All necessary Potential free contacts for indications relevent to RMU monitoring and control .g) Capacitor voltage dividers serving Live-Line Cable indicators in each Breaker and Isolator.
Maintenance/Repairs including loading/unloading, carriage, transportation of Packaged Substation - 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 630 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with all interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications:A) 3 way Non - Extensible RMU (breaking capacity 25kA for one second) with 2no. 630 A load break switch and 1 no. 200 A tee off with SF6 Circuit Breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T's etc. to complete as required to entire satisfaction of Engineer-in-charge.B) 1 no. 11 kV / 433V, 400 kVA three phase,Copper Wound Level-2 DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings.C) 1 No. 433V, 800A LT devices with PVC sleeved Aluminium Busbars.D) One no. 4pole 630A, 25kA MCCB with microprocessor Based Release.E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400 Amp.each. Including
3phase 4 wire energy meter. F) Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. umarmoured XLPE Cable 95 kVp. G) The provision for solid connection with Aluminium strips with Heat Shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB .
Maintenance/Repairs including loading/unloading, carriage, transportation of Packaged Substation - 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 400kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with all interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications:A) 3 way Non - Extensible RMU (breaking capacity 25kA for one second) with 2no. 630 A load break switch and 1 no. 200 A tee off with SF6 Circuit Breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T's etc. to complete as required to entire satisfaction of Engineer-in-charge.B) 1 no. 11 kV / 433V, 400 kVA three phase,Copper Wound Level-2 DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings.C) 1 No. 433V, 800A LT devices with PVC sleeved Aluminium Busbars.D) One no. 4pole 630A, 25kA MCCB with microprocessor Based Release.E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400 Amp.each. Including 3phase 4 wire energy meter. F) Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. umarmoured XLPE Cable 95 kVp. G) The provision for solid connection with Aluminium strips with Heat Shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB .
11 Mtr. Long ST Poles ( SP 56) with pit excavation
9 Mtr. Long ST Poles (SP 33) with pit excavation
8 Mtr. Long ST Poles ( SP 15) with pit excavation
Maintenance/Repairs/ Laying of cement bottoming for following Poles:
cement bottoming for 11mtr pole 0.6 cum/pole 1:2:4 ratio as per standard
cement bottoming for 9 mtr
pole 0.48 cum / pole 1:2:4 ratio as per standard
cement bottoming for 8 mtr pole 0.48 cum / pole 1:2:4 ratio as per standard
Maintenance/Repairs of paint and Painting with red oxide
Maintenance/Repairs of paint and Painting with Al paint
Maintenance/Repairs including loading/unloading of Allied accessories of distribution transformers.
11 kV GO AB Switch Station Type of Standard Make (200 Amp) as per relevant IS.
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type as per relevant IS.
DO 11 kV Horn Gap Fuse Set 3 Phase 200A as per relevant IS.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm
11kV Polymeric Disc Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm
LT Shackle Insulator.
LT GI mukki clamps 50x6 mm with Bolt
LT D Clamp
11KV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch.
Maintenance/Repairs of Straight Through Cable Jointing Kit for 11KV ABC of following sizes:
Straight Through Jointing Kit for 70-120 mm²
Straight Through Jointing Kit for 150-185 mm²
Straight Through Jointing Kit for 240-300 mm²
Straight Through Jointing Kit for 400-500 mm²
Octagonal Pole
Straight Through Jointing Kit for 630-800 mm²
Maintenance/Repairs including loading/unloading of 6.0 mtr Long GI (65 micron DFT single dip) Octogonal poles uniformally tappered with thickness of 3mm with bottom/top Dia of 135 mm x 70mm & base plate of 225x225x12mm/pcd 250 mm provided with proper door opened gear box for connections on the bottom side with G.I. Foundation Bolts (J Type) M25x750 mm long (Set of 4 no.’s per pole)
Maintenance/Repairs including loading/unloading of 9.0 mtr Long GI (65 micron DFT single dip) Octogonal poles uniformally tappered with thickness of 3mm with bottom/top Dia of 175 mm x 70mm & base plate of 275x275x16mm/pcd 250 mm provided with proper door opened gear box for connections on the bottom side with G.I. Foundation Bolts (J Type) M24x750 mm long (Set of 4 no.’s per pole)
Maintenance/Repairs of FOUNDATION OF OCTAGONAL POLES
DISTRIBUTION SERVICE PILLAR
RCC foundation for 9.0/6.0 mtr. Long Octagonal poles including proper curing. 0.6mX0.6mX1.2m (RCC with concrete ratio 1:1.5:3 with minimum 8 Nos. of 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C for fixing the pole).
Maintenance/Repairs including loading/unloading of 1 phase 2 wire, 415V, 1No. of 100 Amps incoming SP MCCBs fitted with outgoing 04 No. 32 Amps SP MCBs for Service Connections, Distribution Service Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars 2P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 4 way Distribution Service Pillar.
Maintenance/Repairs including loading/unloading of 3 phase, 415V, 1No. of 250 Amps incoming 3 TP MCCBs (Breaking 25KA) fitted with outgoing 03 No. 100 Amps SP MCCBs, 1No.100Amps 3 pole MCCB for outgoing LT cables, Distribution feeder Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7 tank process with PU painted Busbars 4P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 4 way Distribution Feeder Pillar.
LED FIXTURE
Maintenance/Repairs including loading/unloadingof 3 phase, 415V, 1No. of 250 Amps incoming 3 TP MCCBs (Breaking 50 KA) fitted with outgoing 03 No. 100 Amps SP MCCBs, 1No.100Amps 3 pole MCCB for outgoing LT cables, Distribution feeder Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7 tank process with PU painted Busbars (6mm thickness)4P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 12 way Distribution Feeder Pillar.
Ornamental Pole
Maintenance/Repairs including loading/unloading of 45/50/60/120/190 Watt LED Light fittings/Ornamental Fixtures of IP 67 protection
Maintenance/Repairs including loading/unloading of 9/6 Mtr MS/Cast iron Ornamental Pole
Maintenance/Repairs including loading/unloading of 4 Mtr MS/Cast iron Ornamental Pole
Maintenance/Repairs including loading/unloading of 3 Mtr MS/Cast iron Ornamental Pole
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BidDocument.pdf
Tender Documents • 0.43 MB
BOQ_968253.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid