Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
24 Feb 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM,ELECTRICAL-EPG
EPG TnC CELL NALCO DAMNJODI
Operation and Maintenance Contract of Construction Power Network of Alumina Refinery and Various Petty Electrical Jobs Required for Enabling Works of NALCO Damanjodi
2022_NALCO_672870_1
MnR/PROJ/TnC/2022/09
Limited
Miscellaneous Works
Works
730 days
NALCO, DAMANJODI
5 documents required · 5 mandatory
₹0
₹40,000
Yes
26 Feb 2022
10 Feb 2022
26 Feb 2022
10 Feb 2022
24 Feb 2022
10 Feb 2022
90 days
Amount
PART - A: MANNING
Two shift manning with either A & B or G & B shift as per the requirements laid in the SCC of Contract.
One shift manning with A or B or G shift as per the requirements laid down in the Contract.
One shift maning with C shift as per the requirements laid down in the SCC of Contract.
Supervisor in General Shift for overseeing assigned activities of the contract
PART - B: SWITCHGEAR MAINTENANCE
Issue from owner's store, and Replacement of 11KV lightening arrestors as per the direction of EIC. All the consumables are to be arranged by the contractor.
Dismantling of 11KV A.B. switch with all accessories including transporting & depositing at Owner's store as per direction of EIC.
Issue from owner's store, transporting & Installation and commissioning of 11KV AB Switch. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Issue from owner's store, transporting & Replacement of one set of moving / fixed contacts of 11KVAB Switch. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Maintenance of 11KV A.B. switch for smooth and proper functioning including supply of cleaning agents / lubricants. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Dismantling of 11KV D.O. fuse complete with barrel and ornaments
Issue form owner's store and Fixing of 11KV D.O. fuse complete with / without barrel and ornaments. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Issue from owner's store, transporting & Replacement of Disc/pin/post insulator…All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Issue from Owner's store and replacement of Disc. Insulators of O/H Line, 4 Pole.
Issue from Owner's store and replacement of Pin/Post Insulators of O/H Line,
Installation of Stay sets of HT Lines complete with supply of all materials, hard wares & accessories.
Issue from store & Installation of stay sets of HT Lines up to 11 KV without supply of materials.
Stringing of OH line of group of conductors.. For HT line upto 11 KV as per direction of EIC.
Fabrication and erection of supports (Material shall be free issue from NALCO).All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Binding/ Jumpering of O/H HT lines and cables wherever required, as per direction of EIC.
Removal of Binding / Jumpering of O/H HT lines and cables wherever required.
Laying of H.T. Cable over any surface,clamping to the wall/ poles/structure/Trays.. of size 3C X 185 - 300 sqmm, upto a height of 20 m. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Excavating of trench & Laying / removal of HT Power cables..supply & spreading of sand and laying of bricks, back filling etc.. 3C X 185 - 300 sqmm.
Installation of stay of HT lines complete with supply of all materials, hard wares & accessories. All the tools & tackles, consumables, labour required for execution of the job are included in the scope of the contract. The work to be executed as per the direction of EIC.
Stringing of OH line of group of conductors.. For HT line upto 11 KV including supply of hardwares if required as per the direction of EIC.
Dismantling, shifting to ERS for Over-hauling and back to site, Re-erection of the same by connecting all the cable, etc. for Transformers of 11/0.415KV Up to 1000 KVA. as per the direction of EIC.
Periodic routine maintenance of substations up to 11/0.433 KV, 1000KVA
Supply & Making of End termination & testing of 11KV cables by heat shinkable cable jointing kit of Raychem/3M make.
Supply & Making straight through joint in 11 KV cable.. By heat shinkable cable jointing kit of Raychem/3M make.
PART - C: L.T. SYSTEM MAINTENANCE
Excavating of trench & laying / removal of multicore power cables of voltage grade up to 1.1KV including (shifting of cables) with supply & spreading of sand, bricks, back filling etc Upto 3.5 x 70 sqmm.
Excavating of trench & laying / removal of multicore power cables of voltage grade up to 1.1 KV including (shifting of cables) with supply & spreading of sand, bricks, back filling etc Above 3.5 X 70 sqmm & upto 3.5 X 185 sqmm.
Shifting and Laying of Cables over ground in ready structures, cable trays etc. Control cable upto 2.5 sqmm & upto 19 core with proper saddling & dressing as per the direction of EIC. Cable shall be issued as free issue item.
Shifting and Laying of Cables over ground in ready structures, cable trays etc. Upto 3.5 x 50 sqmm, with proper sadding & dressing as per direction of EIC. Cable shall be issued as free issue item.
Shifting and Laying of Cables over ground in ready structures, cable trays etc. Above 3.5 X 50 sqmm & upto 3.5 X 185 sqmm Cable shall be issued as free issue item.
End termination of control cables.
Size 2.5 sqmm upto 19 core
End termination of L.T. Power cables.
Upto size 3.5 x 25 sqmm. (without supply of DC-Gland & Socket)
Upto size 3.5 x 25 sqmm. (with supply of Gland & Socket)
Upto size 3.5 x 95 sqmm & above 3.5 x 25 sqmm. (without supply of DC-Gland & Socket)
Upto size 3.5 x 95 sqmm & above 3.5 x 25 sqmm. (with supply of DC-Gland & Socket)
Upto size 3.5 x 185 sqmm & above 3.5 x 95 sqmm. (without supply of DC-Gland & Socket)
Upto size 3.5 x 185 sqmm & above 3.5 x 95 sqmm. (with supply of DC-Gland & Socket)
Upto size 3.5 x 300 sqmm & above 3.5 x 185 sqmm. (without supply of DC-Gland & Socket)
Upto size 3.5 x 300 sqmm & above 3.5 x 185 sqmm. (with supply of DC-Gland & Socket)
Supply & Making of Straight through joint of LT cable..
From 10 to 16 sqmm -Raychem/3M (With Supply)
From 10 to 16 sqmm -(Without Supply)
From 25 to 95 sqmm -Raychem/3M (With Supply)
From 25 to 95 sqmm - (Without Supply)
From 120 to 185 sqmm-Raychem/3M (With Supply)
From 120 to 185 sqmm. (Without Supply)
From 240 to 300 sqmm-Raychem/3M (With Supply)
From 240 to 300 sqmm-(Without Supply)
Erection, Testing and commissiong of LT Panel / Feeder Pillar.
Up to 100 AMP Incomer
Above 100 to 500 Amp Incomer
PART-D PETTY JOBS
Checking,testing, replacing, repairing of electrical items.
Maintenace of 40W Tube light fitting with supply of tube
Maintenace of 40W Tube light fitting including replacement of tube/choke/starter
Installation, testing of following fixture with all hard wares excluding supply of materials.
All types of Light Fixtures
Making temporary lighting for construction site.
1 x 40 & 2 x 40 W/ tube light fitting/2X18 W LED Light Fittings
Flood Light /Halozen light fitting.
Laying / Dismantaling of Cable to provide Light / Power for temporary connection & depositing in Owner's Store. (Shifting of cables is in contractor's scope)
Cable from 3.5 x 2.5 Sqmm to 6 Sqmm.
Cable from 3.5 x 10 Sqmm to 50 Sqmm.
Cable from 3.5 x 70 Sqmm to 120 Sqmm.
Cable from 3.5 x 150 Sqmm and above..
Through cleaning, applying red oxide primer and two coats of paint including all labour and supply of paints
DP-Combine with AB Switch & Drop-out Fuse Unit to Transformer.
Four pole structure-Combine with 4 nos of AB Switch.
Surface of steel structure / Electrical Eqpt. Like switch boards, panels, feeder pillars etc.
Disconnection / Reconnection of cables from LT & HT motors or panels as required as per the direction of the EIC.
Cleaning of CSS switchyard including removal of grass /small plants etc
Surface wiring with supply of 2.5 sqmm Cu wires two runs and 1.5 sqmm Cu Wire one run for earthing including supply and fixing of casing capping as per the direction of the EIC.
Supply and installation of MS switch board of size 4 x 6" including fixing of 1 no 6A switch and 1 no (Two in one sockets)
Supply and installation of MS switch board of size 6 x 8" including fixing of 1 no 16A switch and 1 no of 6/16A (Universal sockets)
Supply and installation of MS switch board of size 8 x 10" including fixing of 2 nos 6A and 16A switch with 2 nos of 6A and 16A multipin sockets.
Supply of 8 x 10" MS Switch boards with 2nos. of 6A & 2nos. of 16A switch and multipin socket with internal wiring and 15mtr. length flexible copper wire to use as Extension board.
Supply of unskilled worker on daily wage basis as and when informed by Engineer-in-charge
BASUDEVI ERECTOR
RRR PERESTROIKA
SUSHANTA ENGINEERS
stage.html
html • 0.02 MB
finance_708110.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .