Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.2 L+₹2.3 L (14.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹20.4 L+₹4.5 L (28.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹23.8 L+₹7.9 L (49.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹28.7 L
EMD Value
₹57,500
Closing Date
1 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt Pin-144005
Please refer tender documents
2022_MES_554206_1
8322/37/E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Jalandhar Cantt
Class D Category b(ii) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer Kapurthala
₹57,500
Yes
6 Dec 2022
24 Sept 2022
8 Nov 2022
24 Sept 2022
1 Nov 2022
20 Oct 2022
Amount
Supply only new insulating transformer oil and filling after dehydration of transformer oil to obtain di-electric strength not less than 50 KV at 4 mm gap , conforming to IS-335, filling in repaired transformer or for topping up of transformers installed at site complete all as specified and as directed at site by Engineer-In- Charge . Make of oil : Power oil/Savita/Indian Oil or equivalent.
Dehydration and filtration of transformer oil/ voltage stabilizer oil at site of installation for 11 KV, 433 step down transformer of any capacity and any make installed on poles/plinth mounted indoor/outdoor and obtaining di-electric strength minimum 50 KV (r.m.s) with in 1 minute with 2.5 mm gap with portable filtration cum dehydration machine. Note :- (Testing of di-electric strength of dehydrated transformer oil of each transformer /voltage stabilizer will be carried out in the presence of Engr-in-Charge.)
Disconnecting of HT/LT side connection of transformer after disconnecting electric supply opening/ disconnecting the foundation earth and neutral connection out side of the transformer and taking down the transformer any capacity up to 250 KVA from 2/4 pole structure including loading transportation and unloading to workshop/ factory drainning out transformer oil or site to avoid dust and moisture and back to yard/ site after repair complete all as specified and directed. NOTE:- (i) The rate quoted for this item deemed for lifting and shifting the transformer will be done by crane where ever posible to lift with crane
Opening of transformer cover and all other connected accessories taking out the transformer oil from tank taking out core assembly disconnecting the core and taking out unserviceable HT/LT coil after opening/ dismantling all connection inside the transformer capacity up to 250 KVA and reassembling the rewinding HT/LT coil and Transformer oil in original position with making alignment for smooth functioning the Transformer and replacement of burnt out LT/HT bush and gasket to avoid leakage of oil, refilling back oil into the transforme complete all as specified and directed NoteI i) Centrifuging of transformer oil shall be measured and paid seperately ii) Repair work of transformer shall be measured and paid seperaetely (iii).The transformwer rewinding work shall be carried out at certified renowned workshop/ company (iv) The all type of transformer tests shallbe carried out before installing the rewounded transformer in the presence of Engr-in-Charge.
Supply and fixing /winding fabricated DPC copper strip of suitable guage/size and required shape for rewinding of LT coil of transformer up to 250 KVA including necessary ovening and insulation material complete all as required an directed.
All as per above item No 5 but using copper wire of suitable size/ guage and shape for rewinding of HT coil including necessary insulation material complete all as required and directed .
Supply only tap changer switch suitable for outdoor/indoor type for transformer of capacity upto 250 KVA, suitable for fixing on HV side to vary the voltage on LV side upto +7.5% in steps of 2.5% complete all as specified and directed.
S&F in replacement of unserviceable porcelain vitreous bushing of required size / shape (suitable for existing transformer ) for spindle of transformer of any capacity upto 250 KVA 11KV outdoor type siutable for HT side all as specified and directed.
Same as above but 11000 Volts grade suitable for HT side indoor type
Same as above but 1100 Volts grade suitable for LT side indoor type
Same as above but 1100 Volts grade suitable for LT side outdoor type
S&F in replacement of unserviceable brass spindle duly threded at the end complete with nut bolts and washer suitable for HT side of transformer out door type all as specified and directed at site for the following capacity suitable for existing transformer of required size/ shape for spindle of transformer of any capacity up to 250 KVA 11000 volts grade outdoor type suitble for HT side all as specified and directed :-
All as above item but suitable for LT side of transformer of following capacity
M&L for Transporting transformer and making all necessry connection of any capacity up to 250 KVA on 2 pole/4 pole sturucture from any location to another location at Suranussi including loading / unloading or depositing the transformer to E/M yard or other location in the area under GE Kapurthala complete all as specified and directed at site.
Supply and Fixing the transformer silica gel breather complete with all accessories for transformer of any capacity up to 400 KVA all as directed at site.
M&L transformer silica gel complete with all accessories for transformer of any capacity all as directed at site.
S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for suitable 11000 volts.
Supply and fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS clamps with necessary bolts, nuts and washers all as specified of sizes 100 mm bore
Dismantling & taking down existing ACSR conductor of any size by opening the binding wire from HT electric poles complete all as specified.
Taking down cross arms, channels, angle iron, clamps, nut, bolts, stay wire, stay assembly, GI wire, anti climbing devices, danger notice boards etc complete al as soecified and directed .
Taking down old rusted GI pipe of any size from pole/trench complete all as specified.
Taking down insulators off size & type all as specified.
Supply and fixing and stringing in replacement ACSR conductor (weasal /Ferret /squirrel) on LT poles / service brackets including binding of conductor with aluminum binding wire complete all as specified and directed.
Supply and fixing MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding bending, cold or hot, drilling joles or bolt in any shape of size including 2 coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Repairing, greasing and setting of GOD triple pole 11 KV 200/400 Amps complete with replacement of old unserviceable parts and setting alignment for its smooth operation including taking out old parts all as directed. Note :- New parts required for repiring shalll be measured & paid separately under relevant items as supply only.
Supplying only the following items:-
Post insulator for triple pole 11 KV upto 400 amps GOD.
Male contact assemble with arcing horns suitable for 11 KV
Female contact/fix contact jaw assembly suitable for 11 KV AB Switch.
Tinned copper flexible jumper upto 400 Amps suitable for 11 KV AB Switch
Back connector plate suitable for 11 KV AB Switch.
Tightening and restringing existing loose/broken conductor (ACSR) continuous earth wire any type including stringing including replacement of fresh binding wire all as required at site all as directed.
Supply and fixing Pin type insulator porcelain viterous white brown or green incl one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nutrs 150 mm height, 150 mm dia for 11000 volts grade. Make Jaipur/Rashtriya
Supply and fixing Disc type composite polymeric insulators, 11000 volts grade, 45 KN, with tension clamps, bolts, nuts etc complete all as specified and directed . Make Jaipur/Rashtriya
Supply and fixing Loop type insulator porcelain vitreous, white or brown for HT say large size with overall diamensions 90 x 140 mm, clearance hole 25.5 mm for 11000 volts grade. Make Jaipur/Rashtriya
Supply and fixing for Danger notice plate for HT of 25 cm x 20 cm x 1.6 mm thick mild steel sheet vitreous enameled white, with letters figures and conventional skuull and bones and written as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25 mm x 3 mm , including nuts & bolts including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to be written in three languages viz Punjabi Hindi and English.
Dismantling and taking down GO Switch off size including, operating machanism etc complete from any position.
Supplying and fixing switch Air break Gang Operated Switch outdoor type HT 11 KV triple poles upto 400 amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechnically operating from ground level vertical mounted complete with HT insulator on steel frame operating rod made out of 25 mm GI pipe medium grade worked from ground level with handle and locking arragement with 12 insulators with drop out fuses complete all as per specified and directed by Engr-in-Charge and (Clamps/cross arms shall be measured and paid for separately) Make : Jaipuria/Rashtrya.
Supply, fixing and testing & cable jointing Kit for 11 KV grade cable for indoor type ermination cold shrinable joint complete with joining material and accessories suitable for XLPE armoured aluminium cable of size 95 Sqmm 3 Core. Make : Denson/M Seal/Raychem.
All as per item No 34 here-in-before in before but of size 120 sqmm to 185 sqmm 3 core.
Supply, fixing and testing after jointing Cable jointing Kit for 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminium cable of size 95 Sqmm 3 core. Make - Denson, M Seal/Raychem
All as per item No 36 here-in-before in before but of size 120 sqmm to 185 sqmm 3 core.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sqmm 3 core.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sqmm 3 core.
Supply and fix cable jointing kit for 11 kV grade cable for straight through Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sqmm
Supply and fix cable jointing kit for 11 kV grade cable for straight through Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 sqmm
M&L for filling and levelling with 40mm graded stone gravel thickely packed 150mm thick all around the transformer/panel/ 2 pole structure area complet for protection all as required and directed at site.
Excavation over areas in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested, all as specified and directed.
Removing excavated surplus soil (Soft/loose soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
Material and labour for clean dry sand laid in trenches/ducts for cushioning to cable complete all as specified.
Supplying and laying cable cover precost concrete Class HV, Type I, flat, size 300 mm x 180mm x 40mm
M&L for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal GL with the top edge of the plate not less then 1.5 mtr below the normal GL connected to GI strip 32 x 6mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel and protected by 40mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) including GI wire meshed funnel and chamber PCC (1:4:8) type D2 using 40mm grade stone aggregate, coping shall be (1:3:6) type CI using 20mm stone aggregate with RCC 1:2:4 type B1 (using 20mm graded stone aggregate) pit cover re-inforced with 8mm dia at 80mm c/c both way in lieu of CI pit cover with angle iron frame, including excavation and earth work in any type of soil and removal of surplus soil of earth complete all as shown in electrical plate of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point all as specified and testing of earthing on completion. NOTE 1. The unit rate includes for protection pipe and GI strip 32X6mm from top of earth plate up to 7.5 meter above ground level.
Material and labour for Prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area complete testing of line all as directed. (Note : (i) Rate quoted inclusive are repair to damage work in item (ii) Each Span approx 30-40 Mtr).
Taking down HT switch gear (Vacuum circuit breaker) of capacity 630 to 800 Amps, 11 KV upto 350 MVA of make - Crompton/ Siemens inlcuding, overhauling, repairs servicing and refixing the same to its original position after repairs, overhauling carried out through OEM and comprising of the following :- (a) Tripping off the breaker, isolating the breaker with handle, disconnecting breaker control socket and pulling out the breaker complete from the panel along with the trolley for servicing/ inspection/ overhauling. (b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability with electrical inter locking/indication limit switches and replacement of required spares as directed by Eng-in- charge. (c) Servicing/Inspecting/checking of circuit & bus spout and circuit & bus spout connections for RYB phases, applying petroleum jelly on spouts, applying one coat of insulation paint on spout insulation (d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f) Servicing/inspecting/checking of secondary scokets/bus bar earthing plugs/earthing sockets and replacement of spares if required. (g) Checking/setting and adjustments of services and isolate operation of the breaker trolley. (h) Lubrication and greasing of all moving parts of the trolley, stopper bot for proper operating and closing of shutter gear, isolation resistance of Vaccum interruptor assembly. (j) Dismantling the complete cable chamber, decrabuzing chamber inspecting cable earthing. Decrabonizing/cleaning the complet. (k) HT 11 KV 3 phase independent bus bar, bus bar chamber of HT panel and inspecting the bus bar insulators, applying one coat of epoxy insulation paint on insulators, CTs PT bushings, cablechambers and if flash has been happended testing IR value. (Note :- New parts required for repiring shalll be measured & paid separately under relevant items as supply only) .
Supplying the following items :-
Space Heater suitable for HT VCB 11 KV of Make - Crompton
Big Gear suitable for HT VCB 11 KV of Make - Crompton
Small Gear suitable for HT VCB 11 KV of Make - Crompton
Amperemeter 2" x 2" square shaped range 0-200 Amps CT ratio 100/50/5, Make AE
Voltmeter 2" x 2" square shaped range 0-15 KV PT ratio 11000/110 Volts, Make AE
Segmented Gear suitable for HT VCB 11 KV
Indicator Red,Green, Amber (Volt 24 to 220V AC/DC) suitable for HT VCB 11 KV
Indicator Blue & White (Volt 24 to 220V AC/DC) suitable for HT VCB 11 KV
Power pack DC for auxiliary power supply to operate closing & tripping coils, protection relay circuits & other indication lamps for 11 KV HT VCB panel suitable to operate the control circuit on in put supply 230 Volts AC + 10% to - 30 %, 50 HZ to give an out put supply of 110 V, DC complete all as directed. Make : Gogate Electro systems(P) limited/Alan power pack
Breaker auxilary switch (7No/7Nc)
Breaker control switch (TNC switch)
Current transfomer suitable for 11 KV 200V-100/5+5A of primary wounded type,core 1 - 15 VA, class - 1.0, core 2-15 VA class SP10 and epoxy conforming to IEC - 60186 all as directed. Make :-CG/Areva/Southen switchgear
Isolating Contact suitable for HT VCB 11 KV
Spout Bushings suitable for HT VCB 11 KV of Make - Crompton
Fuse link with capacity 63- 100A for HT 11 KV
HRC berral fuse,3 Amps (PT HT side)
CRC (2-26) of 500 ml unit for cleaning of VCB parts
Testing of Relay with digital protective relay three phase 11KV over current and earth fault relay's of CT ratio 50/25/5 smooth functioning of relay and necessary connection with copper wire and setting according to the existing load of the panel by approved company rep and explain to the MES rep to further handle if necessary complete all as required and directed.
Caliberation of electro mechanical Relay with digital protective relay three phase 11KV over current and earth fault relay's of CT ratio 100/50/5 and 30/15/5 smooth functioning of relay and necessary connection with copper wire and setting according to the existing load of the panel complete all as required and directed.
Supply, fixing and testing of three phase 11KV over current and earth fault relay's of CT ratio 100/50/5 smooth functioning of relay and necessary connection with copper wire and setting according to the existing load of the panel complete all as directed.
M&L for scrapping down old painted surfaces of HT Pole, applying two coats red colour synthetic enamel paint over one coat of red oxide primer using spray jet and lettering of HT Pole number with white colour of approved make: Berger/Asian complete all as specified & directed by Engineer-in-Charge.
Matterial, Labour & Transportation for locating fault of HT/LT under ground cable with cable fault locating Machine and locate any pin point faults in LT/HT Cables upto 11 KV cables including following instruments:- (i) Impulse generator 0-11 KV. (ii) Acoustic fault locator to pin point the fault exactly at fault point (iii) Reflectometer (Laptop based) TDR set =input wave capturing (iv) High voltage Murray loop for % distance to constant leakage faults (v) Cable fault locating machine mounting on sutable vehicle.
Transformer head gasket cut & made to shape with provn of reqd holes as per original for transformer of capacity upto 315 KVA.
M&L for scrapping down old painted surfaces of Transformer and preparing the surface for painting, applying two coats synthetic enamel paint over one coat of red oxide primer using spray jet of approved make: Berger/Asian including cleaning and degreasing the surface complete all as specified & directed by Engineer-in-Charge.
S&F informatory name board of size 1200 mm x 900 mm made of aluminium sheet 2 mm thick with stainless steel rectangular frame using 25 x 15 mm rectangualr pipe with 35 mm dia stainless pipe in outer border all around retro reflective high intensity 400 micron thick blue colour sheet pasted with heating process on both sides of the board including 75 mm to 100 mm high white colour letters cut to shape with special plotter and in proper manner indicating Sub station No/Name and Location of installation as directed by Engr in Charge, 02 Nos 75 mm dia stainless steel pipes of 304 grade glossy finish with MS plate 3 mm thick welded at bottom of pipes shall be provided. The board shall be fixed at height of 3.00 m (Top level of board) above GL and shall be embedded in ground using PCC 1:2:4 type B-1 of min size 300 mm x 300 mm x 600 mm including necessary form work, excavation and earth work complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Shree Balaji Construction
AGGARWAL ENGINEERING CO
DUGGAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .