Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAdmitted-Finance AMLA TOLA CHAIBASA | CHAIBASA | WEST SINGHBHUM | JHARKHAND | ₹8.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹8.9 Cr+₹49.1 L (5.81%)Admitted-Finance M 13 S S HARMU HOUSING COLONY PS ARGORA PO DORANDA RANCHI JHARKHAND 834002 | RANCHI | JHARKHAND | 834002 | ₹8.9 Cr+₹49.1 L (5.81%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical A 104 SYMPHONY PLOT NO 9 NEAR SAHJANAND CHOWK HARMU HOUSING COLONY HARMU RANCHI JHARKHAND | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Rejected-Technical SERVESHWARI BHAWAN NEAR MAHADEV MANDIR KATHAL MOD PO LALGUTWA THANA NAGDI JHARKHAND 835303 | RANCHI | RANCHI | JHARKHAND | 835303 | - | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | M/S MANOJ KUMAR PANDEY L2 | M/s Satyam Builders L1 |
|---|---|---|---|---|---|
| 1.00Section I Building Work | |||||
| 2.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 684.4 | Cum. | 170 ₹1,16,348.68 | 151.82 ₹1,03,906.22 Lowest |
| 3.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.
2.7.3 Hard rock (blasting prohibited) | 684.4 | Cum. | 1,150 ₹7,87,064.6 | 1,028.09 ₹7,03,628.91 Lowest |
| 4.00 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. | 682.77 | Cum. | 60 ₹40,966.5 | 55.28 ₹37,743.8 Lowest |
| 5.00 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) | 110.6 | Cum. | 600 ₹66,360 | 589.51 ₹65,199.81 Lowest |
| 6.00 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. | 704.38 | SQM | 450 ₹3,16,971 | 356.52 ₹2,51,125.56 Lowest |
| 7.00 | Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level
1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) | 98.96 | CUM | 4,900 ₹4,84,904 | 4,598.23 ₹4,55,040.84 Lowest |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
IN FOUNDATION | 263.66 | CUM | 5,900 ₹15,55,594 | 5,218 ₹13,75,777.88 Lowest |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete | 702.92 | sqm | 210 ₹1,47,612.78 | 194.5 ₹1,36,717.55 Lowest |
| 10.00 | Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 209.31 | CUM | 6,500 ₹13,60,528 | 6,308.87 ₹13,20,522.2 Lowest |
Tender Value
₹8.5 Cr
EMD Value
₹8.5 L
Closing Date
22 May 2023, 5:00 pmClosed
Chief Engineer
Jharkhand Police Housing Corporation Limited, Line Tank Road, Ranchi
Construction of SSP Office Building at Jamshedpur in the district of East Singhbhum
2023_JPHCL_70909_1
JPHCL/GR 01/NIT 03/2023-24
Open Tender
Civil Works - Buildings
Item Rate
365 days
Jamshedpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
JPHCL, Ranchi
₹8.5 L
Yes
17 Jun 2023
13 May 2023
24 May 2023
13 May 2023
22 May 2023
13 May 2023
Amount
Section I Building Work
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. 2.7.3 Hard rock (blasting prohibited)
Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.
Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) IN FOUNDATION
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts
Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
Reinforced cement concrete work in beams,Slab,lintel, lintel Band etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
Reinforced cement concrete work in beams,Slab,lintel Band ,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges
Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and Shuttering including strutting, propping etc. And removal of form for Stairs, (excluding landing ) except spiral staircases
Reinforced cement concrete work in beams,Slab,lintel,etc suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position complete as per building specification and direction of E/I.(Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
Providing Tor Steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved design and drawing including carriage of M.S. Rods (straight or in coils) to work site, cutting bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I(Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
(a) 10 mm (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
(b) 12 mm (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
(b) 16 mm (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
(b) 20 & 25 mm (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Extra for Brick work for each consecutive floor above first floor including watering and scaffolding all complete as per direction of E/I 2nd
3rd Floor
Tarrace
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
Making 6x6 mm Groove in plaster surface over walls trully horizontal and vertical as specified at regular intervals, at all heights including cleaning finishing scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I
Extra for plaster work over exteriour surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I
3rd Floor
terrace
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) overand including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I.
5.6.23 Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. 5.6.23.4 With commercial grade colour 15X15cm Tiles.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, exceptWhite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
DSR 11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Extra for pre finished nosing to treads of steps of marble stone.
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white Cement and matching pigments etc., complete. Size of Tile 600x600 mm .
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete Size of Tile 800x800 mm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms,vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Providing and fixing wooden moulded beading to door frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 2nd class teak wood (50X20 MM)
.Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
supplying fitting fixing good quality well drassed and well seasoned sal wood work in chaukhat in doors , window skylights fanlights and C/W celetial window openings , including wedge over all clampes complete including application of two coats of wood preserative of apporoved quality of the surface batting walls and lintels all complere as per building specification and direction of E/I
Providing and fixing factory made P.V.C. door frame manufactured by M/s Rajshri or equivalent of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers speci fication and direction of Engineer-in-Charge.-
Providing and fixing 30 mm thick factory made PVC rigid foam panelled door shutters manufactured by M/s Rajshri or equivalent made from M.S. tube of 19 gauge thickness, size 19 x 19 mm for styles and 15 x 15 mm for top and bottom rails, covered with heat moulded PVC "C" channel of 5 mm thick and 75 mm wide PVC sheets for top rail, lock rail and bottom rail on either side and 5 mm thick, 20 mm wide cross PVC sheet as gap insert for top rail and bottom rial, panelling of 5 mm thick PVC sheet fitted in the M.S. frame welded/ sealed to the styles and rails with 5 x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineer-in-Charge fixed to frames with 4 Nos. M.S. powder coated butt hinges (For W.C. and bathroom shutters).
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
D4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Supplying, fitting & fixing M.S. Grill made of 20x6mm flat as per approved design and drawing aproperly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Prividing French spirit polishing over new wooden surface to give desired texture and gloss with apporoved make and shade of ready mixed french polish including preparing the surface sfter cleaning removing dirt.
Providing and fixing cup board shutters with 25 mm thick veneered particleboard IS : 3097 marked, exterior grade (Grade I), of approved makeincluding IInd class teak wood lipping of 25 mm wide x 12 mm thickwith necessary screws and bright finished stainless steel piano hinges,complete as per direction of Engineer-in-Charge. With decorative veneering on one side and commercial veneering on other side
Providing two coats of synthetic enamal paint of apporoved shade and make over new wooden surfaceincluding cleaning the surface after removing dirt, scales smokes grease and sand papering , including cost of scaffolding and taxes all complete as per building specefication as direction of E/I
Providing primer one coat of red lead paint ofapproved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
DSR 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing & supplying Cico liquid / impermo water proofing compound in cement concrete or cement mortar @ 2% of cement quqntity by weight ( as specified) for water proofing, including all carraige and taxes .
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible.
Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes.
75 mm dia
110 mm dia
Providing & fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion
Bend -110 mm
Shoe - 110mm
Bend -75 mm
Shoe - 75 mm
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Provoiding and laying vitrified parking/industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS 4457:2007 of approved make in all colour and shades laid on 20mm th cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg sqm including grouting the joints with white cement and matching pigments etc complete size of tiles 300x300x10mm size
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing and laying 60mm thick factory made Cement Concrete Interlocking Paver Block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick complacted bed of course sand, filling the joints with coarse sand etc. all complete as per the. direction of E/I.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, icrowave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science &Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO /IEC 17011 and accredits labs as per ISO/ IEC 17025.
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, uts, bolts, washers etc. all complete as per the Architectural rawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.
For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steelscrews, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be nterlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having erforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
Analysed and Approved (rate taken from admin uld. cts musaani) Providing and laying Enginnered marble over 12 mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curiing taxes and royalty all complete as per building specification and direction of E/I.
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(B) BRICKs
(C) LOCAL SAND
(D) COARSE SAND
(E) STONE CHIPS
(F) CEMENT
(G) STEEL
(H) Earth
Section - II Water supply and sanitary installation works
3.2.1 Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50 grms, 15mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificatin and direction of E/I. (A) 580 mm long (c) with 10 ltrs. low level P.V.C. Cistern
3.2.2 Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C with Ptrap of parry/Hindustan or any other approved I.S.S make ineluding supplying and fixing 15 liters C.I mosquito proof low down flushing cistern of approved make with complete fittings with C.I handle and R.S or bracket wit h telescopic flush pipe with brass eoupling and plumbers joints spindle stop coci of approved quality weight not less than 450grams 15mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white /black plastic solid state seal and lead of commander / cuckoo or other I.S.S make with hinges or screws etc painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. (i) With 'P' trap (b) 10 Lit Low Level PVC Cistern.
DSR 18.49.1 Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 15mm nominal bore approved brand C.P. fittings
DSR 18.50.1 Providing and fixing C.P.brass long nose bib cock of approved quality conforming to standard and weight not less thain 810gms. 15mm nominal bore approved brand C.P. fittings
DSR 18.50.1 Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.15mm nominal bore approved brand C.P. fittings
DSR 17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
DSR 18.65 Providing and fixing PTMT / C.P Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
DSR 18.53 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
DSR 18.75.1 Providing and fixing P.T.M.T. / C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms
DSR 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )
18.17.1 25MM nominal bore
18.17.2 32MM nominal bore.
DSR 17.32.2 Providing and fixing Mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. Rectangular shape -453 X357 mm
DSR 17.7 Providing and fixing Wash basin with C.I/M.S brackets, 15mm C.P. pillar cock 32mm C.P brass waste of cutting and making good the wtherever require.
DSR 17.7.4 Falt back wash basin size550x400mm with single 15mm pillar tap
DSR 18.58 Providing & fixing PTMT Grating of approved quality anc colour.
DSR 18.58.2.1 RECTANGULAR type 125 mm nominal dia. With 25 mm waste hole.
DSR 18.74.2 Providing and fixing unplasticised P.V.C. connection pipe with c.p. nuts collar and bush of approved quality. 15 mm nominal bore with 45 cm length.
DSR 17.28.2.1 Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible Pipe
DSR 12.41.2 Provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.)
D.S.R 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
DSR 12.42.1.1 Coupler 75 mm
DSR 12.42.1.2 Coupler 110 mm
DSR 12.42.2 Single pushfit Coupler
DSR 12.42.2.1 75 mm
DSR 12.42.2.2 110 mm
DSR 12.42.3 Single tee with door
DSR 12.42.3.1 75 X 75 X 75 mm
DSR 12.42.3.2 110 X 110 X 110 mm
DSR 12.42.4 Single tee without door
DSR 12.42.4.1 75 X 75 X 75 mm
DSR 12.42.4.2 110 X 110 X 110 mm
DSR 12.42.5 Bend 87.5°
DSR 12.42.5.1 75 mm Bend
DSR 12.42.5.2 110 MM Bend
D.S.R. 12.42.6 SHOE - 110MM
DSR 12.42.6.1 75 MM
DSR 12.42.6.2 110 MM Shoe
D.S.R.12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
DSR 12.43.1 75 mm
DSR 12.43.2 110 mm
D.S.R 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
DSR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL) Concealed work including cutting chases and making good the wall etc..
18.8.1 15mm dia
18.8.2 20mm dia
Exposed on Wall
18.9.3 25mm dia
18.9.4 32 mm dia.
18.9.5 40mm dia
D.S.R 18.37.1 Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
D.S.R 19.6.2 Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe
D.S.R 17.11.2 Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required: 610x510mm bowel depth 200mm
Analysed & Approved Providing and fixing C.P. brass swan neck sink cock for kitchen sink of approved quality 15mm nominal bore, approved brand C.P. fittings.
DSR 18.64 Providing and fixing PTMT/ C.P. swivelling shower,15mm nominal size, 95mm long, 65mm dia. of approved quality, color & make weighing not less than 40 gms with approximate 80 holes of 1.2 mm dia.
D.S.R 17.73.2 Providing and fixing c.p. towel rail complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Prayag or equipment)
D.S.R 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fitting arangement of approved quality colour and makeweighing not less than 90 gms.
Analysed & Approved Providing and fixing JET SPRAY IN COMODE with all connection pipe. C. P. BRASS
Section III Septic tank & Soakpit (2 No's)
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.2.2 Providing designation 75A brick work in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri
5.2.23 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.7.2 Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
5.7.11 Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Basic Rate of SOR 2021 M-198 (page no 44) Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet
5.5.5 Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio
(a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
DSR 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter
Basic Rate of DW & SD SL NO 31(b) M 947 Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg).
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(A) BRICKs, LEAD - (1K + 29P = 30 KM.)
(B) COARSE SAND, LEAD -(1k + 24p=25 KM.)
(C) STONE CHIPS , LEAD - 20 KM.
(D) CEMENT , LEAD - 05 KM.
(E) STEEL , LEAD - 05 KM.
Section IV 200x150xmm dia Deep bore Well With Pump set & electrification etc works.
DW & SD Basic rate item no. 119 M 1035, pg no. 58 Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.
From 0.0M to 50.0 M belew G.L
From 51.0 M to200.00 M belew G.L
DW& SD Basic rate item no. 120 M 1036 , pg no. 58 supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job.
DW& SD Basic rate item no. M 1042 S.I no. 126, pg no. 65 Cleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc.
DW & SD Basic rate item no. M 1036 S.I no. 120, pg no.58 Supplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I For safety of drilling bore including providing of guard for safety of the same till returned final.
DW & SD Basic rate item no. 139 M 1055, pg 67 Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.
Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages 2.0 HP
DW & SD Basic rate item no. M 1065 S.I no. 149 , pg no. 78 Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914. F.A.S.D. Starter ( 10 H.P )
Energy Department Basic rate item no. M 1627 , pg no . 36 Supplying 3 core flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed as per IS : 7098 3 Core 4mm thick
Analysed & Approved 2no heavy duty clamp 40mm dia suitable for 200 mm dia pipe with all complete job.
DW & SD Basic rate item no. 14(K) (v) , pg no. 35 Supplying & lowering 40mm da column G. I. pipe with all complete job.
Section V Rain Water Harvesting
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.2.3 Providing designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
SOR Page 36 of Itm no M-009 & 10% CP Stone Metal at quarry site .. Traxes and royalty all complete as per building specification and direction of E/I. 90 mm Gravel filling
0.90 M stone Boulder filling
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.7.1 Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
5.7.6 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
DSR 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
DSR 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
( 12.42.5.2) 110 mm bend
( 12.42.6.2) Shoe 110 mm
DSR 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete (110 mm )
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(A) BRICKs, LEAD - (1K + 29P = 30 KM.)
(B) LOCAL SAND , LEAD - 3 KM.
(C)COARSE SAND, LEAD -(1k + 24p=25 KM.)
(D) STONE CHIPS , LEAD - 20 KM.
(E) CEMENT , LEAD - 05 KM.
(F) STEEL , LEAD - 05 KM.
SOR PHED (page no 56 M 1038) DT: Basic rate for 125/115 mm dia drilled Tube Well for drilling in all kinda of Soil and rock for installation o hand pump with DI rings all complete including supplyin all materials, labours , tools drilling rigs air compressor and equipments s well as fuel li\ubricant for making 125/115 mm dia boring etc and cost of transporting rig machine and other vechile up to site of work including contrctor profit & OH chares as per specification and directtion of Engineer Incharge(basic rate)
Drilling upto 30 M depth below G.L in Rular area
Drilling beyond 31 mtr upto 55 mtr below GL in Rural area
SOR PHED (page no 17 sl no 105) Basic rate of 32 mm UPVC pipe 125 mm dia conforming o IS: latest version:
S/M/L for F/f wire mesh pipe
Section VI Drain (30 M)
5.1.1 Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
5.1.10 Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
5.6.1 Providing designation 75 A one brick flat soling joints filles with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.2.3 Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
5.7.11 Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I.
5.5 Providing TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
5.5.4 8 mm dia - TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(A) BRICKs, LEAD - (1K + 29P = 30 KM.)
(B) LOCAL SAND , LEAD - 3 KM.
(C) COARSE SAND, LEAD -(1k + 24p=25 KM.)
(D) STONE CHIPS , LEAD - 20 KM.
(E) CEMENT , LEAD - 05 KM.
(F) STEEL , LEAD - 05 KM.
5.1.1 Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
5.1.2 Extra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)
5.1.10 Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5.6.1 Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work up to plinth level- Foundation
5.3.1.4 1:3:6 ( 1 cement : 3 coarse sand ( zone - III) ;6 graded stone aggregate 20 mm nominal size).
5.3.9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering,finishing and reinforcement. All work up to plinth level ( foundation)
5.3.9.1 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size)
5.3.17 Centering and shuttering including strutting,propping etc and removal of form for
5.3.17.1 Foundations,footings,bases of columns etc for mass concrete
5.3.10 Reinforced cement concrete work in walls ( any thickness),including attached pilasters,buttresses,plinth and string courses,fillets,columns,pillars,piers,abutments,posts and struts etc . above plinth level up to floor five level excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size)
5.3.17 Centering and shuttering including strutting,propping etc and removal of form for
5.3.17.6 Columns,pillars,piers,abutments,posts and struts
5.3.11 Reinforced cement concrete work in beam ,suspended floors,roofs having slope up to 15 landing ,balconies,shelves,chajjas,lintels,bands,plainwindow sills,staircases and spiral stair cases above plinth level up to floor five level,excluding cost of centering,shuttering ,finishing and reinforcement 1:1.5:3 (1 cement:1.5 coarse sand( zone III) : 3 graded stone aggregate 20 mm nominal size)
5.3.17 Centering and shuttering including strutting,propping etc and removal of form for
5.3.17.5 Lintels ,beams,plinth beams,girders,bressumers and cantilevers
5.2.3 Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
DSR 13.46.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
(5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet
5.5.5 Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio
(b) 12 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
(c) 16 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
5.5.29 Supplying,fitting and fixing 20 guage G.C.l. sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1".2.4 ) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specrfication and direction of E/|
5.8.41 Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)
5.8.45 Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(A) BRICKs, LEAD - (1K + 29P = 30 KM.)
(C) COARSE SAND, LEAD -(1k + 24p=25 KM.)
(D) STONE CHIPS , LEAD - 20 KM.
(E) CEMENT , LEAD - 05 KM.
(F) STEEL , LEAD - 05 KM.
APPROACH ROAD 50 Mtr leangth
5.3.2.1 Providing P.C.C.M 200 in normal mix of (1:1.5:3) in foundation with approved quality of stone chips 20mm to 6 mm size graded and clean coarse sand to F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
3.01 Embanjkmenr\t construction with material obtained from Borrow Pits (Construction of embanlment with approved material obtained from borrow pits with all lifts and leads transporting to site, spreding , grading to required slope and compacting to meet requirement of table 300-2)
(i) Rolling with vibratory roller
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5.6.2 Providing designation 75A one brick edge soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(A) BRICKs, LEAD - (1K + 29P = 30 KM.)
(B) LOCAL SAND , LEAD - 3 KM.
(C) COARSE SAND, LEAD -(1k + 24p=25 KM.)
(D) STONE CHIPS , LEAD - 20 KM.
(E) CEMENT , LEAD - 05 KM.
LAND DEVELOPMENT
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
(157) 5.1.8 Filling in foundation trenches and plinth layers not exceeding 150 mm thick well watered rammed fully compacted and fine dressed with earth obtained after cutting with in a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume)
(158) 5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
(159) 5.2.3 Providing designation 75A brick work in CM (1:6) in Foundation and plinth with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
(160) 5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
(161) 5.3.2.2 Providing P.C.C.M 150 in normal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I
(162) 5.7.1 Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
(163) 5.7.11 Providing 1.5 mm thick cement punning including curing, carriage of water with all leads and lifts of water as per building specification and direction of E/I.
(166) Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(A) BRICKs, LEAD - (1K + 29P = 30 KM.)
(B) LOCAL SAND , LEAD - 3 KM.
(C) COARSE SAND, LEAD -(1k + 24p=25 KM.)
(D) STONE CHIPS , LEAD - 20 KM.
(E) CEMENT , LEAD - 05 KM.
(F) STEEL , LEAD - 05 KM.
Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Finolex/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / C&S/ Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:Havell's/L&T/Legrand/Schneider/C&S (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard/Finolex (7) LED FTTING FIXTURE -: Havells/Bajaj/Crompton/C&S (Model/as per E/I ) (8) CEILING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha (Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Surya/Valmont/RR Ispat/Transrail (10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Mahindra
1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
1.3.3 Group C
1.4 Twin control point wiring PVC conduit with modular type switch:-wiring for Twin control point with 1.5 sq mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, 2 way modular, switch, pheonlic lamineted sheet,suitable size G.I.box etc.as required.
1.5 Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1.7.1 2x1.5 sq mm+1x1.5 sq mm earth wire
1.7.2 2x2.5 sq mm+1x2.5 sq mm earth wire
1.7.4 2x6.0 sq mm+1x6.0 sq mm earth wire
1.7.10 4x6 sq mm+2x6 sq mm earth wire
1.7.12 4x16 sq mm+2x6 sq mm earth wire
1.17 TV cable in existing conduit :- Supplying and drawing co-axial TV cable RG-6 grade copper conductor,PE insulated,with PVC sheath in the existing recessed PVC conduit as required.
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
1.21.2 25mm FOR TV WIRING
1.22 S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required .
1.22.9 210mm x206mm x 48 deep/(10" x 12") for tv wire on roof
1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
1.24.1 5/6 amps, one way switch
1.24.4 5/6 amps, 3 pin socket outlet
1.24.5 15/16 amp 6 pin socket outlet
1.24.7 TV socket socket outlet
1.25 S/F Modular type electronic fan regulator:-Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connectionons but excluding modular plate etc, as required.
M-1493 Supply of Modular type AC starter switch for single phase 230 V /50 Hz of capacity 20/25 amp
1.26 S/F Modular type blanking plate:-Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc, as required.
1.27 S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
1.27.1 1 or 2 module(78mm x 78mm x 45mm)
1.27.3 6 module(78mm x 205mm x 50mm)
1.31 S/F light plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch conection painting etc, as required.
1.32 S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
1.33 S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
1.34 S/F Batten holder:- Supplying and fixing batten/angle holder including connection etc, as required.
1.35 Errection on incandescent light fitting:- Errection of wall bracket/ceiling fitting, complete with all accessories including connection etc as required.
1.36 S/F Dingdong Call bell :- Supplying and fixing dingdong call bell suitable for DC/AC single phase,230 volt, complete as required.
1.38 S/F Call bell buzzer :- Supplying and fixing call bell buzzer suitable for DC/AC single phase,230 volt, complete as required.
1.39 S/F twin twisted cable :- Providing and fixing plain 16/.20 mm (0.50 sq mm) twin twisted, flexible,FR PVC insuleted copper cable, in polythene sleeve of suitable size on the floor/wall ,or side of the table door etc as required
1.48 ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
2.9 S/F T.P.MCB DB:- Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
2.9.4 4 way (4+12),Double door, Horizontal type for lift room
2.9.4 4 way (4+12),Double door, Horizontal type
2.9.5 6 way (4+18),Double door, Horizontal type
2.11 S/F 'B' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.11.1 6/32 amps,single pole, "B" SERIES for lift room
2.11.1 6/32 amps,single pole, "B" SERIES
2.12 S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.12.1 6/32 amps,single pole, "C" SERIES
2.12.9 40 amps,TPN for light db
2.12.10 50/63 amps, TPN for power db
2.12.9 40 amps,TPN for ups floor db
2.12.10 50/63 amps, TPN for lift room
2.18 S/F 20 amps SPN MCB industrial socket outlet:- Supplying and fixing 20 amps, 240 volts,SPN industrial type, socket outlet, with 2 pole and and earth, metal enclosed plug top along with 20 amps 'c' series, SP MCCB, insheet steel enclosure,in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
2.19 P/F M.V. danger notice plate:- Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
3.2 G.I Earth pipe electrode with salt charcoal :- Earthing with G.I. earth pipe 4.5 mtr long,40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. with salt charcoal or coke.
3.6 Copper Earth plate electrode:- Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke)
3.7 S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
3.8 S/L 6 SWG G.I. wire ground :- Supplying and laying 6 SWG G.I. wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
4.2 P/F G.I. lightning conductor finial:- Providing and fixing of lighting cnductor finial, made of 25 mm dia 300mm long, copper tube having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
4.4 Reverting, sweating and soldering of copper/G.I. tape(with another coppr/G.I. tape, base of the finial or any other metallic object) as required.
4.7 P/F G.I. lightning conductor tape in horizontal run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(For horizontal run)
4.8 P/F G.I lightning conductor tape in vertical run:- Providing and fixing GI tape 20mm x 3mmthick on parapet or surface of wall for lightning conductor complete as required(for vertical run)
4.12 P/F Testing joint for G.I. lighting conductor:- Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long, with 4 nos.of G.I. bolts, nuts, chek nuts and spring washers etc complete as required.
5.1 Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
5.4 Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
Code no. Supply of PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g
M-741 6 sq.mm. 4 core
M-740 16 sq.mm. 4 core
M-332 150 sq.mm. 3.5 core
M-335 300 sq.mm. 3.5 core
12.37 DSR Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
12.39 DSR Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required
9.1 DSR Supplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
9.1.32 DSR 4 X 10 sq. mm (25mm)
9.1.33 DSR 4 X 16 sq. mm (28mm)
9.1.26 DSR 3½ X 150 sq. mm (50mm)
9.1.30 DSR 3½ X 300 sq. mm (70mm)
7.10 DSR Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
CODE No. M - 775 Providing of 12'' (300 mm) Metal exhaust fan of make bajaj/havells/usha/crompton
CODE No. M - 777 Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton
CODE No. M - 869 Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
Code no. M 874 Supplying and fixing of cable junction box of make sintex /Hensel
Anaylised & Approved Supplying of 8 feet long 40 watt 3000K Recess connect PROFILE LIGHT luminire well designed extrudedAluminium housing linier Profile with efficiency 110 lm/W and perfect optics control
Anaylised & Approved Supplying of 4 feet long 40 watt 3000K Recess connect PROFILE LIGHT luminire well designed extrudedAluminium housing linier Profile with efficiency 110 lm/W and perfect optics control
Anaylised & Approved Supplying of decoretive ceiling hanging light
Anaylised & Approved S/F of wall hanging dia cast aluminium body tempered glass diffuser IP 54 MATT GREY FINISH 90 V-260 V AC (WARM WHITE) 2X3 WATT led UP and DOWN lighter OF MAKE -JAQUAR / BAJAJ/ HAVELLS
M -1455 S/F OF LED Indicator light Red/Green For ssp/city sp/rural office door
9.1 SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
9.1.7 90 /100 W LED Street light of make bajaj/havells/crompton/C&S
9.2 S.I.T.C of following rating LED FLOOD lighting with pressure dia cast housing and toughened glass cover (IP 66 protection)in existing pole/pipe /platform/periferial wall for supply voltage 100-270v AC,50Hz Luminire shall be confirmto IS-10322 part-5/ section-3 and shall be complete with all neccssary accessories as required.of make bajaj/havells/crompton/C&S
9.2.8 240 W LED FLOOD LIGHT 3000 K of make bajaj/havells/crompton/C&S
9.3 SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required.
9.3.4 18/20 W LED Round Down Light of make bajaj/havells/crompton/C&S
9.3.11 2'x2' LED Panel Light of make bajaj/havells/crompton/C&S
9.3.13 6 W COB based round LED light with multiple beam angle (36 Degree) of make bajaj/havells/crompton/C&S/Jaguar
9.4 S.I.T.C of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standared length (upto 30cm) with 1.5 sq.mm FR PVC insuleted ,copper wire suitable for 230 V 50 Hz, single phase supply etc. complete as required.
9.4.1 1200 mm (48") Ceiling Fan of make bajaj/havells/usha/crompton/polar
9.5 SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required
9.5.1 10/12 W LED Batten of make bajaj/havells/crompton/C&S
9.5.2 20/22 W LED Batten of make bajaj/havells/crompton/C&S
9.6 S.I.T.C of following rating LED Post top lamp made in dia cast aluminium housing with decoretive clear / opel acrylic diffuser on existing pipe including connection with 1.5 sq mm copper conductor etc all complete as required. Of make bajaj/philips/polycab/jaguar
9.6.5 40/45 W LED Post top Lamp clear
M-1501 Supply and fitting of LED strip light IP:65 rated in different colours of length 5 mtr and power 5W per mtr including driver IS:10322 part 5 /section 7
9.7 S.ITC of Following rating approved make LED Bollard fitting with Rectengular shape of hight 600 to 850mm Power input - 8/9 watt with dia cast aluminium housing opel with PC diffuser IP:65/54 protection , conferming to IS:10322 part -5 etc all complete as required (excluding plinth charge) Of make bajaj/philips/polycab/jaguar
Anaylised & Approved Constructing platform of 300 mm dia 600 mm long with 300 mm depth bellow ground and rest 300 mm exposed over ground to support Bamboo Bollard with all finishing plaster putty & paint all complite as per direction of E/I
Code no. M-1494 S/F of LED type Name Plate
Code no. M-742 Supply of 7 Mtr height Octagonal Hot Dip Galvenized pole (BOP - 7030) with top dia 70 mm, bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12mm (L X B X T) including suitable sizes of foundetion bolt all complete as requried. (Without Arm)
Code no. M-754 1 Mtr Single Arm suitable for 70 mm TOP
Code no. M-875 Instalation Testing & Commisioning of 7 Mtr Octagonal Pole & light fitting with the help of tools & plants, wiring of luminaires with all materials and construction of shallow foundetion with M 25 grade concreat considering safe soil bearing capacity of 10T/Mtrs sq
Anaylised & Approved Supplying, designing, manufacturing, installation, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing of 150KVAR 14STEP A.P.F.C. Panel Double door(Capacitor Bank / Auto Mannual) of 16 SWG CRCA sheet (2 mm) steel IP – 43 floor mounting cubical type Double door Capacitor Bank Panel suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 36kA with front operated construction including separate fabrication arrangement for fixing 400 A 3 P0LE BC-36KA with O/L &S/C protection &Adjestable thermal magnetic release MCCB, , M.C.B., Capacitors, Contactors etc.The sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized with locking arrangement duly fixed on Base Channel with proper lifting arrangement size – 50 mm x 50 mm x 4 mm having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs and Capacitors having earthing arrangement.All openings shall be covered by soft rubber gasket, enclosure shall be galvanized. (15 x 2) x 1 Set = 30 KVAR (Power Capacitor) Ultra Heavy Duty. Make:- Legrand/ L&T / Schneider-Mehe (10 x 2) x 1 Set = 20 KVAR (Power Capacitor) Ultra Heavy Duty. Make:-Legrand/ L&T / Schneider -Meher (5 x 2) x 1 Set = 10 KVAR (Power Capacitor) Ultra Heavy Duty. Make:- Legrand/L&T/Schneider -Meher.(20 x 2) x 1 Set = 40 KVAR (25 x 2) x 1 Set = 50 KVAR (Power Capacitor) Ultra Heavy Duty Alongwith 2 Nos 3 pole MCB 10A 10KA,2 Nos 3 pole MCB 16A 10KA.2 Nos 3 pole MCB 25A 10KA.2 Nos 3 pole MCB 10A 10KA,2 Nos 3 pole MCB 40A 10KA, 6 Nos 3 pole MCB 63A 25KA 6 Nos 2 pole MCB 10ka C Curve, 1 No.1 pole MCB 10 KA C Curve, Make:-Legrand/ L&T / Schneider -Meher (Power Capacitor) Ultra Heavy Duty. Make:- Legrand/L&T/Schneider -Meher. TOTAL 150 KVAR
Anaylised & Approved SITC of CRCAsheet steel sheat 1.6 mm thick with 7 tank process powder coated paint.with stand mounting type, with space for 3 phase energy meter as par given drawing, size : as per required space INCOMING 630A 36 KA MCCB FP Adjustable thermal seting 1 No, 250 A 36 KA MCCB FP Adjustable thermal seting 1 Nos, 250A changover FP (ON-LOAD) Open excution type, 160 A FPAuto transfer switch 1No, 800A TPN BUSBAR 1 set, 400 A TPN BUSBAR 1 set Surge Protection Device 4 Pole 65KA 1 No, OUTGOING 125 A MCCB Adjustable thermal seting 36 KA 6 Nos 25/100 A MCCB FP Adjustable thermal seting 36 KA 13 Nos 32 amps.SPN MCB 4 Nos OTHER ACCESSOSRIES DIGITAL VOLT METER 500V(3phase class 0.5) as required DIGITAL A METER 500V(3phase class 0.5) as required COPPER WIRE 1.5MM 4 MM ,6 MM, 10MM,16MM, 25MM as required LED INDICATOR LAMP R/Y/B/G as required C.T COIL OF CT ratio 1000/5 IS2705 part -3 as required
POP SWITCH
Anaylised & Approved S/F of Desk Solution POPUP ALU 8 MODULAR switch Cat No.054013 OF MAKE Legrand/Anchor/schnider
Anaylised & Approved S/F of Desk Solution POPUP ALU 3 MODULAR switch Cat No.054010 OF MAKE Legrand/Anchor/schnider
Anaylised & Approved S/F of Arteor 6 A switch sp 1w1m AR Cat No.573400 OF MAKE Legrand/Anchor/schnider
Anaylised & Approved S/F of Arteor 6 A socket universal india AR AR Cat No.573470 OF MAKE Legrand/Anchor/schnider
Anaylised & Approved S/F of VDI RJ45 CAT6 UTP 1M LCS AR Cat No.573428 OF MAKE Legrand/Anchor/schnider
Anaylised & Approved S/F Arteor USB CHGR 1500mA 1 M TYP A WH AR Cat No.573428 OF MAKE Legrand/Anchor/schnider
Anaylised & Approved S/F Desk Solution BACKBOX CONCRETE POPUP 8MOD Cat No.573428 OF MAKE Legrand/Anchor/schnider
2 TR/1.5 TR SPLIT AC
M - 918 Supply of Category "A" 2.0 Tr capacity Hi-Wall Split AC Unit of BEE Star Rating 5 Star, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising along with original company make stand to fix outdoor unit by suitable size of fasteners, copper pipes up to any length, insulating materials, heavy duty PVC drain pipe. Each drain pipe should be connected with building rain water drain pipe (Make:- Hilty/Fischer) etc as required.Make: Hitachi / Mitsubishi / Daikin / Carrier.
M - 917 Supply of Category "A" 1.5 Tr capacity Hi-Wall Split AC Unit of BEE Star Rating 5 Star, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising along with original company make stand to fix outdoor unit by suitable size of fasteners, copper pipes up to any length, insulating materials, heavy duty PVC drain pipe. Each drain pipe should be connected with building rain water drain pipe (Make:- Hilty/Fischer) etc as required.Make: Hitachi / Mitsubishi / Daikin / Carrier.
M - 1622 Supply, fitting, fixing of wall mount 5 KVA capacity of Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connecting 3 Mtr 3 core 2.5 Sq. mm Flexible Copper cable ( indoor unit to Stabilizer) Make- V-Guard/Totaline/Sen & Pandit.
M - 1621 Supply, fitting, fixing of wall mount 4 KVA capacity of Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connecting 3 Mtr 3 core 2.5 Sq. mm Flexible Copper cable ( indoor unit to Stabilizer) Make- V-Guard/Totaline/Sen & Pandit.
M - 1625 S/F of Out door stand for 2.0 Tr Split AC
M - 1624 S/F of Out door stand for 1.5 Tr Split AC
M - 1618 S/F of copper Tube size 1/2" for split AC unit 1/1.5/2/3 tr capacity 1ncluding nitride rubber insulation
M - 1619 S/F of copper Tube size 3/8" for split AC unit 1/1.5/2/3 tr capacity 1ncluding nitride rubber insulation
M - 1623 S/F of Drain pipe for AC
Anaylised & Approved SITC of 2 MP IR Metal Bullet/ Dome Network Camera,1/3" Progressive Scan CMOS,1920x1080 @30fps,Color: 0.01 Lux @ (F1.2, AGC ON),0.018 Lux @ (F1.6, AGC ON), 0 Lux with IR,H.265+, H.265, H.264+, H.264,Three streams,120dB WDR, 2 behavior analyses, and face detection, BLC/3D DNR/ROI,IP67, IK10,Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,3-Axis adjustment, Up to 50 Mtr IR Range, 3D DNR; ICR; EXIR, up to 50m; DC12V&PoE; Built-in micro SD/SDHC/SDXC slot; cloud service, should have protection level of IP67, IK10 TVS 2000V Lightning Protection, Surge Protection and Voltage Transient Protection, should support ONVIF (PROFILE S, PROFILE G), ISAPI,Preffered Make- Axis/Hikvision/Pelco
Anaylised & Approved SITC of 16-ch 1U 4K NVR,Up to 16 channel IP cameras can be connected,Should support decoding H.265+/H.265/H.264+/H.264 video formats,Up to 4K high-definition live view, storage and playback,Up to 8-ch @ 1080p decoding capacity,Up to 160 Mbps high incoming bandwidth ensures IP cameras can be connected,1 HDMI and 1 VGA interfaces: both interfaces support independent video output,2 HDDs for continuous video recording,Recording Resolution-8MP/6MP/5MP/4MP/3MP/1080p/UXGA/720p/VGA/4CIF/DCIF/2CIF/CIF/QCIF,VGA Output 1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz,Audio Output-1-ch, RCA (Linear, 1 KΩ) Two-Way Audio 1-ch, RCA (2.0 Vp-p, 1kΩ), Up to 6 TB capacity for each HDD,Working Temperature=-10 °C to 55 °C (14 °F to 131 °F),Working Humidity-10 to 90 %, Certifications- CE,FCC,BSI/UL or Equivalent; Preferred Make-Hikvision/Axis/ Pelco
Anaylised & Approved Supply, fitting, fixing, commissioning and testing 32" LFD Full HD Panel with 2 x HDMI, 1 x USB, 1 VGA Port, remote control & battery for remote control along with all accessories & 1 year warranty. for Live View and Replay of Recorded Make:- Make:- LG/ Samsung/Panasonic
Anaylised & Approved SITC of 4TB WD Surveillance Hard Disk storage; Preffered Make- WD/Seagate
Anaylised & Approved SITC of Network switch with 24 x 10/100/1000T PoE ports and 2 x 100/1000X SFP ports, PoE L2 Switch , Switching Capacity 56Gbps and Forwarding Rate 41.7Mpps, Switch should support PoE and PoE+ with 185 W minimum power budget, operaating temperature 0°C to 50°C, , Warranty 1 year from Day 1 . Make:- Cisco,HP,Extreme,Juniper
Anaylised & Approved SITC of 24 port UTP jack panel (24 port RJ-45 Loaded CAT-6 UTP 19" rackmountable patch panel preferbaly with 6 blocks). Preffered Make-Legrand/Panduit/Ortronics
Anaylised & Approved SITC of Straight LAN Patch Chord-1 Mtr Preffered Make-Legrand/Panduit/Ortronics
Anaylised & Approved SITC of 2 Run CAT6 UTP LAN Cable in the existing surface/ recessed steel/ PVC conduit as required for Network only . Make-Legrand/Panduit/Ortronics) ;
Anaylised & Approved Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Anaylised & Approved 100 mm X 100 mm X 60 mm deep
Anaylised & Approved 9 U (WALL MOUNT) Width (mm)-600, Depth (mm) - 600,Network Rack along with all following standard accessories:- (Make : Legrand /Valrack/ Schneider / Rittal)
10 KVA UPS WITH BATTRY
M - 1510 Supply, fitting, fixing, commissioning and testing of 10 KVA, 415V, 3ph input & 3 ph output Power system of input voltage range 110V AC ± 5% -300v AC ± 5% Frequency range 40Hz - 60Hz Power factor ≥ 0.90 @ full load, and output voltage range 200V/208/220/230/240V AC, Voltage regulation ± 1%, Frequency range 50Hz ± 0.25Hz or 60Hz ± 30Hz Harmonic distrortion - < 2%THD (Linear load ) : 4% THD (non - linear load) ON-LINE UPS Approved UPS Make:- APC- Schneider/ Emerson- Tata/ Numeric- Legrand.
M - 1543 S/F of 12V 120 AH sealed maintanance free (SMF) Batterywith 24 month replacement guaranty IS : 1652 : 1991
M - 1519 S/F of MS battery rack suitable for 15 to 20 UPS Battery
Anaylised & Approved NETWORK WIRING ONLY
Anaylised & Approved SITC of 2 Run CAT6 UTP LAN Cable in the existing surface/ recessed steel/ PVC conduit as required for Network only . Make-Legrand/Panduit/Ortronics) ;
Anaylised & Approved SITC of 6 core single mode FIBER optics cable
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
1.22 S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required .
1.22.9 210mm x206mm x 48 deep/(10" x 12")
6 U WALL MOUNT Network Rack
Suply, fixing, fitting, installation and testing of 6 U (WALL MOUNT) Network Rack , CRCA 'D' Grade thickness (mm) - 1.2, RAL 9017 (Matt Black), Glass - 4mm Toughened Tinted Glass Door, along with all following standard accessories. Approved Make: Valrack / Netrack / Rittal
Networking Cabinet Size- 504.65X600X500 (HXWXD)
Approx.Net Wt (kg) - 20
CRCA 'D' Grade thickness (mm) - 1.2, RAL 9017 (Matt Black),
Glass - 4mm Toughened Tinted Glass Door,
Accessories:,
Cooling Fan (230V A/C 90 CFM) - 2 Nos,
PDU 230VAC - 1 No,
Cable Manager Metal- 1 No,
Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) - 1 No,
Wall Screws (4 sets of 2'' screws, washer,rubber grommet (nickel coated)) - 1 No,
Door Lock - 1 No,
Front Metal Band -1 No.
In the rack there must be maintained 1 U = 1.75 inches space.
Anaylised & Approved Cost of Wall Mount 6 U Network Rack
22 U FLOOR MOUNT Network Rack
Providing. fixing, fitting, installation and testing of 22 U (FLOOR MOUNT) fully loaded Network Rack Width (mm)-600, Depth (mm) - 800, Approx.Net Wt (kg) - 32, CRCA 'D' Grade thickness (mm) - 1.2, RAL 9017 (Matt Black), Glass - 4mm Toughened Tinted Glass Door, along with all following standard accessories. (As per approved make list. )
Accessories:
Castor Wheel - 04 Nos.
Cooling Fan (230V A/C 90 CFM) - 2 Nos
PDU 230VAC - 1 No,
Cable Manager Metal - 2 Nos,
Earthing Strips 150mm H - 1 No,
Mounting Hardware (20 sets of M6 screws,washer,cage nuts (nickel coated)) - 1 No, Wall Screws (4 sets of 2'' screws, washer,rubber grommet (nickel coated)) - 1 No,
Door Lock - 1 No
Front Metal Band -1 No
In the rack there must be maintained1 U = 1.75 inches space.
Anaylised & Approved Cost of Floor Mounted 22 U Rack
Anaylised & Approved Providing, fixing, fitting, connecting and testing of white RJ 45 Cat 6 Data outlet / Toolless information outlets with white coloured RJ-45 transparent shuttered modular scoket outlets with front plate. ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed, for computer networking complete in all respect suitable to fix in modular plate type switch system with connections as required. Approved Make: Legrand / AMP / Schneider
IP PABX SYSTEM
1.16 Teliphone wiring existing conduit:- Supplying and drawing following pair 0.5 sq mmFR PVC insuleted copper conductor, unaramed teliphone cable in existing recessed PVC conduit as required
1.21 JSR S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
1.22 S/F PVC/G.I. boxes :- Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc as required .
1.22.9 210mm x206mm x 48 deep/(10" x 12")
Anaylised & Approved Providing, fixing, fitting, connecting and testing of white RJ 11 Telephone outlet / Toolless information outlets with white coloured RJ-11 transparent shuttered modular scoket outlets with front plate. For telephone socket complete in all respect suitable to fix in modular plate type switch system with connections as required. Approved Make: Legrand / AMP / Schneider
Krone box:-Providing, fixing, connecting & testing of Krone box (Telephone Tag Block) in a thermoplastic, IP 65 (weather proof) enclosure, internally embedded gasket, anti corrosive, insulated and shock proof with provision for cable through IP 65 glands complete in all respects.
Anaylised & Approved 10 pair Tag Block (krone Box) (136 mm x 253 mm x 115 mm)
Anaylised & Approved 50 pair Tag Block (krone Box) (300 mm x 300 mm x 70 mm)
Anaylised & Approved IP PABX SYSTEM:- Supply, fitting, fixing, commissioning and testing of IP based 100% nonblocking IP PABX System should be a IP Compatible with rich feature set of the system and can be connected with pure Voice over IP (VoIP) communication network across corporate Local and Wide Area Networks (LAN and WAN) as & when required. Central Processing Unit: The system main software should be open architecture based. The CPU of main system shall be 32 bit processor working at 2.0 GHz or better. The system should be Wall mountable. • System Architecture should be latest pure IP and should be wall Mountable “ Meet-me conference 30 party X 2 from day 1 must be available. Must Support Unified Communications Equipped with 32 Analog extensions 32 IP Extensions alongwith IP User License loaded from day expandable upto 96 Extensions, VOIP CARD in built charger, battery with one our back up facitity. 03 Analog Trunk Ports, 1 PRI , 02 Ports Auto Attendant- IPABX. Approved Make: NEC/ Alcatel / Infinity
Providing, laying, connecting, testing & commissioning of multi-core telephone un-armoured cables of conductor size 0.5 sq.mm. annealed tinned electrolitic grade copper, PVC insulated, twisted pairs bunched together, over all PVC sheathed, GI strip or wire armouring laid on existing cable tray or along the wall or laid in pipes or in trenches including excavation of cable trench, sand filling covering with bricks and back filling complete as required. Make: Polycab / Finolex/ Belden
Anaylised & Approved 10 pai r PISTL1 0PXO. 51008
Anaylised & Approved 50 pair
Television
Anaylised & Approved Supply. Fitting, fixing and testing of 43" LED Flat TV full HD, resolution-1366 x 768 with 1 x HDMI, 1 x USB, remote control & battery for remote control along with all accessories & 03-years warranty. Approved Make: Sony/ Samsung / LG / Panasonic
Anaylised & Approved SITC of 65" Ultra UHD 2160p LED TV.; FIRSTOUCH Smart Television Tv 65 Inch LED Backlit LCD ,Resolution (Pixels)- (3840x2160) UHD, Screen size- 65" , Smart TV, Details of accessories(included in the scope ofsupply) :-Remote Control,Connecting Cable,Batteries, Dimensions (Length xBreadth x Depth) 1,454 x 838 x 57.7 mm. Wall Mount. Power Consumption-198 Watt. Wifi Direct, Built in Wifi. Cost of 65" Full HD LED Panel TV. Approved Make: Sony/ Samsung / LG / Panasonic
Anaylised & Approved Smoke detector
Anaylised & Approved Electronicstrobe cum hooter
Anaylised & Approved Supplying, installation, testing and commissioning of electronic strobe cum hooter suitable for wall mounted complete as required.
Anaylised & Approved Manual Call Point
Supplying, installation, testing and commissioning of manual call box in suitable enclosure with arrangement to raise the alarm when the glass is manually broken complete as required.
Anaylised & Approved Smoke detector
Supplying, installation, testing and commissioning of optical type Smoke Detector with base.
Anaylised & Approved Fire Alarm control panel
Supplying, installation, testing and commissioning of microprocess based eight zone main fire alarm control panel with LCD Display lights. The panel shall have 240 volts AC power supply automatic Battery charger 24 Volts sealed lead acid maintenance free batteries as complete with batteries, battery charger illuminated numeric diagram complete as required.
Anaylised & Approved Cabling
Providing and laying 19mm dia PVC conduit in recessed / surface system PVC insulated copper conductor fire resistant cable of 2x1.5 sq.mm. in existing conduit as required.
Anaylised & Approved ABC type Fire Extinguisher
Stored Pressure ABC Type multi-purpose Fire Extinguisher, Fitted with Squeeze Grip Type Valve with Pressure Indication Gauge & Pressure Discharge Hose Complete with All Mounting Brackets Etc.Conforming to IS:15683 (Cap : 6 Kg)
Anaylised & Approved CO2type Fire Extinguisher
Stored Pressure Aluminum CO2 typeFire Extinguisher, Fitted With Squeeze Grip Type Valve With Pressure Indication Gauge & Pressure Discharge Hose Complete With All Mounting Brackets etc Conforming to IS:15683 (Cap : 4.5 Kg)
VIDEO CONFRENCING
Anaylised & Approved SITC of 86" Ultra HD 2160p LED TV.; FIRSTOUCH Smart Television Tv 86 Inch LED Backlit LCD ,Resolution (Pixels)- (3840x2160) UHD, Screen size- 86" , Smart TV, Details of accessories(included in the scope ofsupply) :-Remote Control,Connecting Cable,Batteries, Dimensions (Length xBreadth x Depth) 1,927 x 1,104 x 59.9 mm. Wall Mount. Power Consumption-339 Watt. Wifi Direct, Built in Wifi. Cost of 55" Full HD LED Panel TV. Approved Make: Sony/ Samsung / LG / Panasonic
Anaylised & Approved SITC of Passive 5" loudspeaker Speaker Type : Passive Point source speaker Driver Size : 1 x 5" LF Driver & 1 x 1/2" HF Driver RMS Power : 25 W Impedance : 4 Ohms Frequency Range (-10 dB) : 60 Hz to 23 kHz Sound pressure level (SPL) : 86 dB Max. short Term Accoustical Output : 112 dB Auto-overload protection prevents tweeter damage and resets automatically Bracket for wall/ceiling mounting Approved make : Music Tribe / Martin Audio / AtlasIED / Bose
Anaylised & Approved SITC of 4 Channel 300 Watt Power Amplifier Class D Power Handling : 4 × 75 W @ 4 Ohms, 4 × 50 W @ 8 ohms RMS Power Bridged Mode : 150 W @ 8 Ω THD 20Hz-20kHz at 1 W <0.3% Frequency Response : 20 Hz to 20 KHz Input Impedence : 10kΩ unbalanced,20kΩ balanced Signal to Noise Ratio : 100 dB Independent limiters for each channel offer maximum output level with reliable overload protection Should have Power, Signal and Clip LEDs to monitor performance Should have independent DC and thermal overload protection on each channel automatically protects amplifier and speakers without shutting down the show Connection : Input - 4 x XLR / ¼ " TRS combo jacks , Output : 4 x locking-style connectors Approved make : Music Tribe / Powesoft / AtlasIED / Bose
Anaylised & Approved SITC of Digital Audio Processor 6 Channel Digital Processor Inputs : 4 balanced mic, 2 balanced Mic/Line,1 stereo unbalanced input Inputs equipped with Low-cut filter, phase inversion and 4-band EQ Onboard AEC processing; 1 stereo and 2 mono outputs Each output channel equipped with adjustable output level, 12-band fully parametric EQ with notch filtering, compressor, limiter, and 8-band feedback suppressor. 2-channel USB audio interface 8 x 3 audio routing matrix; Maximum Gain : 64 dB or better Dynamic Range : 110 dB or better; Signal-to-noise ratio:90 dB or better Front panel Monitoring, Controls and LED indicators; Web Remote functionality IP control for third-party CCS administration; Cascadable upto 6 units Euroblock connectors Accessories : Rack-mount adapters Approved make : Biamp / Clearone / QSC / Audio Technica
Anaylised & Approved SITC of Full HD 1080p @ 60 frames per second PTZ Camera with minimum 20X Optical Zoom and FoV of minimum 57 deg, min 100 Presets. Camera should support simultaneous outputs through Ethernet, HDMI, 3G-SDI, Audio In and can be controlled via RS232 & 422 In & Out & IP.Panning angle -170° ~ +170°, Tilting angle -30° ~ +90° . The tilting and panning speed of camera should be minimum 300° per second. Camera should support SRT, FreeD Protocol, PoE and Virtual USB Driver and should be NDI compatible. OEM should be CE, FCC, RoHS & BIS Certified Approved Make: Sony/ Vaddio/ Lumens
Anaylised & Approved SITC of VC Codec-Wireless Presentation System, including 1No. Omni-directional Mic, remote, Supported Video Codec - H.261, H.263, H.263+, H.264, H.264HP, ITU-T H.239, BFCP. Supported Audio Codec: G.711, G.722, G.722.1, G.722.1C, AAC-LD, G.723.1, G.726, G.728, SILK or better.Built-in video apps for native full-feafured experience, Cables: 2 HDMI 1.8m, 1 CAT 5E LAN 3.6m, 1 CAT 5E SHLD 25ft, 1 HDCI 6ft, 1 HDCI Mini 3m, Power: India BIS. Should be fully compatible with supplied conferrence camera and complete in all aspect. Approved Make: CISCO / Poly / Equivalent or as approved by consultant.
Anaylised & Approved Supplying fitting, fixing, commissioning and testing of 8 pax Lift GeN2-Nova/IMonoSpace PWI08/10-19 R22.1-2 MRL 544 Kg., 8 persons, Microprocessor based 1 mps speed, rise 1O.8 M & Unit 2- 12M, 4 stop 4 opening with (all opening on the shame side) ACD3-MRL controller type VF Re-generative (Closed loop) Drive, 400/415 Volt (3 Fase A.C.) Power Supply, full collecttive operation, 1 Car (Simplex), PM Gearless Machine, Flate Coated Steel Belt, Stainless Steel in hair line finsh with rear glass pannel CD41 false ceiling type (Stainless Steel # 4 (Hair Line) false ceiling finish, Cross Flow Fan ventilation, Stainless Steel Mirror Finish hand rail (Left Hand side, Right hand side and Rear side), Venyle tiles flooring Stainless Steel # 4 (Hair Line), Car door finish and landing door finish, fire rated doors-60 MINS, Central Opening Doors, Door opening 800mm width X 2000 mm H, D.C. door operator, Gien Buttons in stainless steel # 4 (hire line) COP, Dotmatrix (Red L.E.D.) Scrolling Display for Car position indicator, Hall Fixtures O2000, Hall Fixtures Face Plate, Stainless Steel # 4 (hair line), Hall Button with HPI arrangement, Anti-nuisance car call protection, Independce Service, over load device, nudging, emergency firemens service, emergency car light unit, infra red certain door protection, Emergency Alarm Button Extra Door, Time of lobby parking, Door open / close button, automatic resque operation, inspection drive, auto fan cut off with 12 month AMC area valid for the period counted after date of testing and handover to user department. (Of Make-OTIS/KONE).
Add 18% GST
Add 1% Lebour Cess
M/S MANOJ KUMAR PANDEY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
SBD01.pdf
Tender Documents • 1.62 MB
BOQ_95245.xls
BOQ • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .