Providing EI Fans, UPS wiring in proposed rooms for Mini DC, GR site for SZ Main DC GR site for NMS under Phase IX.2 GSM Project at 7th Floor, Telephone Bhavan, Saifabad, Hyderabad. SH Providing EI fans and other connected works.
2023_BSNL_155324_1
21/BEDH-II/2023-24
Open Tender
Electrical Works
Item Rate
30 days
TELEPHONE BHAVAN SAIFABAD
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH MAIN BSNL
₹26,495
5 Jun 2023
26 May 2023
5 Jun 2023
26 May 2023
3 Jun 2023
26 May 2023
Amount
SH I:- EI & FANS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required . A)Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
c) 2 x 10 sq. mm + 1 x 10 sq. mm earth wire
d) 4 x 4 sq. mm + 2 x 4 sq. mm earth wire
e) 4 x 6 sq. mm + 2 x 6 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. A) Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
c) 2 x 10 sq. mm + 1 x 10 sq. mm earth wire
d) 4 x 4 sq. mm + 2 x 4 sq. mm earth wire
e) 4 x 6 sq. mm + 2 x 6 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. A) Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2 x 1.5 sq. mm
b) 3 x 1.5 sq. mm
c) 4 x 1.5 sq. mm
d) 5 x 1.5 sq. mm
e) 2 x 2.5 sq. mm
f) 3 x 2.5 sq. mm
g) 4 x 2.5 sq. mm
h) 5 x 2.5 sq. mm
i) 2 x 4 sq. mm
j) 3 x 4 sq. mm
k) 4 x 4 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required a) 100 mm x 100 mm x 60 mm deep
b) 150 mm x 150 mm x 60 mm deep
c) 180 mm x 100 mm x 60 mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch
b) 15/16 amp switch
c) 3 pin 5/6 amp socket outlet
d) 6 pin 15/16 amp socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 4 Module (125mm X 75mm)
b) 6 Module (200mm X 75mm)
c) 8 Module (125mm X 125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. a) 4 Module
b) 6 Module
c) 8 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Providing and fixing extra conduit down rod of 20 mm dia, 2x10 cm length wiring with 2x1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. a)1 run of cable
b) 2 run of cable
c) 3 run of cable
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. A) Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. A)Group-C
Supplying and fixing 2+12 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of 4 way (4+12), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., as required. (But without MCB/ RCCB /Isolator) M/s Legrand or ss make, (Lights 1No, power - 1No)
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 6A to 32 A Single pole M/s Legrand or ss make.
Supplying and fixing of 63Amps rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. M/s Legrand or ss make
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 40Amps rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
SH-II:- SITC OF FITTINGS AND MISC WORKS SITC of 36 watts recess type LED fitting of size 2' x 2' suitable for operation on 230volts, 50Hz, AC supply including providing chain arrangement for hanging the fitting etc., making good the damages done to the false ceiling, interconnections etc., as required. M/s Wipro Elate CRCO10 / SS model of Philips/CG /SS make.
SITC of 6 watts circular recess LED fitting suitable for operation on 230volts, 50Hz AC supply for Emergency lighting from UPS, including providing interconnections, making good the damages done to the false ceiling etc., as required. M/s Wipro Halo CRDL 11 / SS model of Philips/CG /SS make
Installation testing and commissioning of recovered recess type mirror optic fitting above false ceiling including providing interconnections etc as required.
Supplying and fixing of adaptor box made of 16 SWG MS sheet including cutting welding painting with red oxide and approved colour powder coating, suitable to accommodate loop wires near DB, contactor etc., as required
SH III:- CABLE LAYING AND CONNECTED WORKS Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. a) Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)
b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
c) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)
b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
c) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
d) 2 x 1.5 Sqmm and 2 x 2.5Sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ x 25 sq. mm (28mm)
b) 3½ x 50 sq. mm (35mm)
c) 3½ x 400 sq. mm (82mm)
Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE copper cable of 1.1 KV grade as required. a) 2 x 1.5 sqmm
b) 2 x 2.5 sqmm
Removing of old cables of various sizes from the existing cable tray, removing of saddles, disconnecting the power supply, keeping the cables at safe locating for further reusage etc as rquired.
Disconnecting the power supply, removal of wire from the connector box, dismantling the chain from the cable tray, removing the fitting removal of old fitting from the false ceiling, keeping the same at safe location etc as required.
SH IV:- ITC OF AC UNITS AND CONNECTED WORKS ITC of 1.5 TR Split AC units along with indoor / outdoor units, stand, standard copper pipe line, leak testing, R-22 gas release from OD unit etc., complete as required.
Providing and fixing copper pipe line both 1/4"for gas line and 5/8" for liquid line including providing foaming along the gas line necessary clamping, etc, as required. (For 1.5TR AC unit)
Supplying and laying of 3core x 2.5Sqmm PVC insulated PVC sheathed flexible copper cable suitable for 240V, 50Hz AC supply including internal connections, testing etc., as required.
Supplying and fixing of 40 mm PVC drain pipe along with fixing on wall etc as reqd
Supplying and fixing 20mm dia medium class PVC conduit along with accessories(bends &elbows) in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (for drain line)
Complete gas charging for 1.5 TR window / Split AC units/ single circuit of 1.5 TR split AC with R-22 refrigerant gas including nitrogen pressure testing, leak arresting, vaccumisation etc., as required.
Supplying and fixing of 1.5TR AC protection unit consisting of power socket, top and 20A SP MCB in sheet steel enclosure of including connections, testing etc, as required. (Make:DHDMCSN0251020 Havells or SS Make)
Supplying and fixing of powder coated heavy duty iron stand/ bracket for mounting outdoor unit of the out door type unit on the wall including providing necessary hardware etc, complete as required.
SH V: - EARTHING & CONNECTED WORKS Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. with charcoal/ coke and salt as required.
Supplying and laying 25mm x 5mm G.I strip at 0.50 Mtr below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
SH VI:- MODIFICATION WORKS IN OLD PANEL General servicing of the old existing AC plant panel, checking the control wiring, interconnections to the display accessories like voltmeter, ammeter, LED bulbs etc, recification of faulty wiring where ever required.
Supplying and fixing of following accessories in the existing panel including removing of faulty components, making good the damages done etc as required. a) 63A drum type HRC fuses
b) LED type indication lamps
c) 63A TPN switch fuse unit
Transportation of 3.5 Sqmm x 300 Sqmm cable drum with approxmate cable of length 350mtrs from Vijayawada to Hyderabad Telephone bhavan, saifabad, Hyderabad including loading and unloading hiring vehicle for transport arranging labour etc
SH VII:- SITC OF DISTRUBUTION PANEL Supply of floor mounted cubicle type Indoor extensible floor mounting MV Panel made of 14 G CRCA sheet metal 3 phase and neutral switch board with aluminium busbars suitable for operation on 415 Volts 50Hz, AC supply including providing powder coated painting etc as reqd. Providing and incorporating the following as per detailed specifications. a) Bus bars (Air insulated) of 630 amps capacity for RYB and neutral of suitable cross section and provision for extension on both sides. (Neutral to be of same size as phase busbars) b) Incomming: 4 pole MCCB of 400A, 36 KA capacity with 320-400A Relay, Auxilary Contactor, shunt release with mechanical and electrical inter locking - 3 Nos. (L&T/ Schneider Electric/ Siemens/ or similar superior make). c) out going: 100A TP&N FSU with HRC fuses - 12 Nos (L&T/ Schneider Electric / Siemens/ HPL/Havells). d) Measuring Instruments such as multifunction energy meter with plug in modules for energy metering, harmonics, communication and provision for logging of data. (Schneider Electric/ AE/ Digitron / IMP/Meco / Rishabh /Universal /HPL /L&T /ABB ) -(1No for each incomming) - 2 Sets e) 144 sqmm, 0-100A ammeter along with 100/ 5A CT - 8Nos. f) 400/ 5 amps CT's - 2 Sets g) LED indication lamps - 12 sets. (2Nos for indicating switch ON and OFF) h) Control fuses - 2 Sets. i) MCCB ON/ OFF indication Lamps - 2 sets. with control fuses.
SHAKTI POWER LINES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .