Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.2 Cr+₹1.6 L (1.30%)Rejected-AOC NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹1.2 Cr+₹1.6 L (1.30%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹1.3 Cr+₹3.8 L (3.14%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹1.3 Cr+₹3.8 L (3.14%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹1.3 Cr+₹9.2 L (7.50%)Rejected-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹1.3 Cr+₹9.2 L (7.50%) | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹1.4 Cr+₹17.3 L (14.1%)Rejected-AOC | ₹1.4 Cr+₹17.3 L (14.1%) | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
26 Nov 2022, 6:00 pmClosed
Chief Engineer Chennai Zone
HQ CECZ Chennai
ADDITION/ALTERNATION AND CERTAIN WORK SERVICES TO SHED NO 32 AT ED AVADI.
2022_MES_559740_1
82943/E8
Open Tender
Civil Works
Item Rate
304 days
GE Avadi
As per Tender Document
8 documents required · 8 mandatory
₹1,000
GE Avadi
₹2.3 L
Yes
19 Dec 2022
25 Oct 2022
28 Nov 2022
25 Oct 2022
26 Nov 2022
16 Nov 2022
26 Oct 2022 - 10 Nov 2022
Amount
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and as directed
Supply and fixing Hangers 6 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed
Material and labour for Aluminium Anodised snap grid of size 605 x 605 mm with anodised aluminium angle of size 25mmx25mm x1.5mm thick and main & cross T of size 40mm x 25mm x 1.5mm thick for false ceiling including connection of supporting hangers all as specified and directed .
Supply and fix 10 mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably laced in false ceiling grid made of Aluminium /G.I./M.S. including necessary fasteners for fixing of aluminium grid framework all as specified
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
Supply and fixing Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall/ valley gutters fixed with self tapping screws complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) all as directed.
Supply and fixing PVC (SWR) of dia 160 mm rain water pipes confirming to IS 13592 type 'B' including necessary rubber ring joints fix with valley gutter along wall or cladding all as specified and directed.
Supply and fixing 160 mm dia PVC (SWR) bends any radius all as specified and as directed.
Taking down cement plaster on concrete or brick ,stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.all as directed.
Supply and fixing coloured Glazed ceramic tiles in vertical surface of size 350x250x7mm thick set and jointed in neat cement slurry and pointed in white or color cement to match over 10mm thick cement plaster in cm ( 1:4 ) on fair face of brick or concrete surface etc complete all as specified and directed
Supply and installation of high performance industrial roof vent of 600 mm dia neck of aluminium alloy designed to meet ASS-2428 dated 28 Jan 93 to wind speed of 200 Km/hr and to the entry of wind driven rain at a range of 2.5 litre per second inclusive of base plate and including all accessories all as specified and as directed
Material and labour for preparation of old steel surface and applying one coats of synthetic enamel paint for surface over 10cm width or girth not otherwise described all as specified and as directed.
Taking down aluminium frame exc. 1.5 sqm but n.exc 4 sqm with shutter (without taking of shutter from the frame).all as directed.
Supply and fixing powder coated aluminium frame for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
Supply and fixing powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified.
Supply and fixing Aluminium rebated Mortice Lock vertical type size 100mm four Lever complete all as specified and as directed.
Supply and fixing Aluminum (Die cast) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg all as specified and directed
Supply and fixing 150mm long floor door stopper Aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor all as specified and directed
Supply and fixing 19 mm thick prelaminated particle board exterior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed all as specified and directed
Supply and fixing 5.5 mm thick sheet glass ordinary quality and glazing with aluminum beading, area of each pane exc 0.5 sqm all as specified and as directed.
Supply and fixing MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A all as specified and directed.
Material & Labour for preparing new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of Synthetic enamel paint over a coat of Red oxide zinc chrome primer, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
Material & Labour for Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colored cement to match over 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
Supply & fixing for Non skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular ) area of each tiles exceeding o.11 sqm but not exceeding o.18 sqm ,in floors etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
Supply & fixing in repair Vitreous china urinal partition white of size 310x700 mm, slabs (Urinal partitions) terminating about 40cm above floor line; complete all as specified and as directed.
Material and labour for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polishing complete laid over screed bed or bedding layer of 15 mm thick in cement mortar (1:4) for laying floors, steps, window cills, cooking platforms etc. complete all as specified and as directed.
Supply & fixed in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe etc all as specified and as directed.
Supply & fixed in repairs vitreous China wash down water closet pan (pedestal pattern), white Plastic water closet seat, white, closed pattern with recessed bottom, and cover and mild steel chromium plated or aluminised hinging device including flushing cistern of 10 ltr capacity ,complete all as specified and directed.
Supply & fixed in repairs Counter top vitreous china wash basin white flat back size 460 x 220 mm including waste fittings of brass chromium plated 32 mm (excluding waste pipe, taps chain and plug) complete all as specified and directed. Make -prayag Cat No 4793 or equivalent from the list of manufacturerers
Supply & fixing 32 bore PVC waste pipe 75cm long for sink and wash basin all as specified and directed.
Material and labour for 75 mm dia PVC (SWR) multi floor trap, with grating with hole as required including, jointing with solvent cement, etc all as specified and directed.
Supply & fixing PVC connection 15 mm size with PTMT cut to length 300 mm long complete all as specified and directed.
Supply & fixing Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
Supply & fixed in repair 15 mm dia Pillar taps chromium plated fancy type, screwed down high pressure with or with out letters HOT or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed. Make Prayag Cat No 8202 or equivalent from the list of manufacturers listed herein after.
Supply & fixed in repair 15mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed
Supply & fixed in repair 15mm dia bib tap cast copper ally with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed all as specified and directed
Supply & fixed in repair 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
Taking up or taking down Steel/ iron Tube of 15mm bore and connections including cleaning for refixing or removal to store complete all as directed.
Supply and fix GI tube 15mm bore medium grade including all fittings fixed to walls all as specified and as directed.
Taking up or taking down Steel/ iron Tube of 20 mm bore and connections including cleaning for refixing or removal to store complete all as directed.
Supply and fix GI tube 20 mm bore medium grade including all fittings fixed to walls all as specified and as directed.
Dismantling water tanks and removing to store of capacity exc 500 litre & n.exc 1000 litre as specified and as directed.
Supply and Fix, 1000 litres capacity Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, 'ISI' marked, three layered (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) complete all as specified and as directed.
Supply & fixing 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches etc complete including demolition of pipes complete all as specified.
Supply & fixing 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trench
Supply & fixing 75mm bore PVC (SWR) bend any radius with access door all as specified and directed.
Supply & fixing 110 mm bore PVC (SWR) bend any radius with access door all as specified and directed.
Supply & fixing 110 mm PVC ( SWR) WC connector with lip ring to fit WC outlet all as specified and directed.
Material & Labour for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams for flat rough finished surface of concrete all as directed , etc.
Material & Labour for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintel beam, cantilever beam, bressummers, over 1.5 mtr height complete all as specified and directed
Material & Labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips all as specified and directed
Material & Labour for TMT bars 6 mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire all as specified and directed
Supply only Integral Water Proofing liquid
Cutting opening through brick wall built in cement mortar for door window and other opening or enlarging existing window in to door opening etc or cutting out defective brick work for under pinning including providing fixing and removing shoring cleaning and staking brick removing surplus serviceable brick bricks hard core etc to store and rubbish not exc 50m all as specified and directed
Taking down chowkats or frames exc 1.5 sq. m but n exc 4 sq. m with shutters (without taking off shutters from the frame) all as specified and directed
Supply and Fix factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet and edges will be painted to match with prelam sheet, reinforced with 19mm MS square tube of 19 gauge mitred out at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the drilling 100mm long MS screws using PVC fastener as per specification and drawings as shown in SSR Part II of 2010 complete all as specified and as directed.
Supply & fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail & bottom rail Paneling plain colour PVC sheet to be fitted in MS frame welded/sealed to the stile & rails with suitable PVC sheet beading as per specification & shown on drawing in SSR Pt II of 2010 incl pvc hinges 100 mm size – 3 Nos for each shutter complete all as specified.
Demolition of cement concrete of any description (unreinforced) in ground floors and pavings exc 15 cm and n.exc 0.30 cm thickness (below or above ground level), all as directed.
Material and labour for Plain cement concrete (1:4:8) type D2, using 40 mm graded stone aggregate, 75 mm thick as in sub base complete all as directed
Material and Labour for chequered cement concrete tiles of size 30cm x 30cm x 25mm thick of as approved by GE set and jointed in neat cement slurry as in floors with white cement and pigment laid surface over 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
Material and labour for Plain cement concrete (1:4:8) type D2, using 40 mm graded stone aggregate, 150 mm thick as in sub base complete all as directed
Material and labour for 150 mm thick concrete flooring with RMC M-25 Grade concrete using vacuum dewatering method laid in alternate bays including steel formwork of MS channel section and depth equal to thickness of concrete floor with vacuum flot to obtain level joint filled with sealing compound all as specified and as directed.
Material and labour for preparation of old decorated surface of wall surface applying two coat of white wash complete all as specified and as directed.
Material and labour for Preparation of old surface of wall applying two coats of cement base to external surface Complete all as specified and directed
Material and labour for providing precast cement concrete type B1 1:2:4 type B1 (using 20 mm graded stone aggregate) set in cement mortar 1:4 as in kerb stones of size 0.45 x 0.33 x0.12 m (ready made) all as specified and directed
Material and labour for Cement concrete (1:2:4) type B1 with 12.5 mm graded stone aggregate as in coping and benching complete all as specified and directed.
Supply & fixing frame work such as grills , gratings etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars etc confirming to FE 290 GDE E-165 all as specified and directed
Material and labour for RCC M-30 design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like all as specified and directed.
Material and labour for Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded in concrete, brickwork masonry etc portion and making good disturbed ground
Material and labour for reinforced cement concrete RCC 1:2:4 type B-1, (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm but n exc 250 sq.cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed
Material and labour for Excavation in post holes or (Similar holes) each n.exc 0.5cum, getting out, returning filling in and ramming earth or broken rubber mixed with earth around in layers, n.exc 25 CM watering including removing surplus soil to a distance of 50m from starting point and making good surfaces in Hard/ dense soil.
Material and labour for PCC 1:3:6 type C2 (40mm graded Stone aggregate) as in foundation of post holes filling and mass concrete all as specified and directed.
Supply and fix Galvanised, 2 strand, steel barbed wire in repair 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to MS nibs, precast RCC fencing post, struds etc., including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured and paid separately) all as specified and directed.
Supply and fixed in repair concertina coil fencing with punched tape concertina coil 600 mm dia 10 m openable length (total 90 m) having 50 Nos rounds per 6m length, on existing angle iron Y shape, placed 2.4 m to 3 m apart and incl 09 Nos horizontal barbed wire including dismantling (each line wire to be measured and paid separately) all as specified and directed.
Taking down copper/aluminium point wiring for (light, fan, socket or power) complete including unserviceable fittings such as switches, ceiling rose, holders, sockets etc. and making good the disturbed surfaces on wall/floor etc complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated, FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 25mm dia and its accessories fixed on wall/ ceiling/ trusses /steel structure with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall/steel structure with 3 mm thick laminated hylam sheet top cover all as specified for :-
(a) One light point controlled by one switch.
(b) One Ceiling fan point controlled by one switch.
(c) One exhaust fan point controlled by one switch.
(d One wall mounted fan point controlled by one switch.
(e) One 3 pin 5 amps socket point on independent board
(f) One 3 pin 5 amps socket point on same board
Material and labour for pointing wiring with 4 Sqmm (nominal area) PVC insulated, FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 25mm dia and its accessories fixed on wall/ ceiling/ trusses /steel structure with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall steel structure and with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified
Material and labour for point wiring with 1.5 Sqmm (nominal area) FRLSH ,PVC insulated, unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including in stove enamelled steel conduit of 25mm dia and its accessories fixed on wall/ ceiling and trusses with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.5 mm complete all as specified all as specified for :-
(a) One light point controlled by one switch.
(b) One Ceiling fan point controlled by one switch.
(c) One wall mounted fan point controlled by one switch.
(d) One Exhaust fan point controlled by one switch.
(e) One 3 pin 5 amps socket point on independent board
(f) One 3 pin 5 amps socket point on same board
Material and labour for pointing wiring with 4 Sqmm (nominal area) PVC insulated, FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including in stove enamelled steel conduit of 25 mm dia and its accessories fixed on wall/ ceiling/ trusses /steel structure with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall steel structure and with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified and directed
Supply and fix ceiling rose, surface mount type, PVC/ Polycarbonate, isolated body with face bakelite 65 x 50mm 2/3 terminals complete all as specified and as directed.
Supply and fix switch piano, flush type single pole, one way 5 Amps complete all as specified and directed
Supply and fix switch socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and directed (Through point wiring)
Supply and fix switch socket 3 pin 5 amps , multi pin , flush type, complete all as specified and directed. (Through point wiring)
Supply and fix switch socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete with MS terminal box and laminated hylam sheet with accessories complete all as specified and directed. (Through Submain wiring)
Supply and fix switch socket outlet 3 pin 5 amps flush type complete with MS terminal box and laminated hylam sheet with accessories complete all as specified and directed. (Through Submain wiring)
Supply and fix electronic fan regulator, flush type phenolic laminated sheet etc; as required all as specified and directed
Supply and fix Surface and wall mounted LED tube light fitting, 20 W, batten type, PC housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed. Make : Crompton and equivalent in Havells / Wipro
Supply and fix LED panel light 30 watt (2 x2 ),white powder coated CRCA full glow recess mounting LED Backlit Panel, integrated electronic driver complete including connection from ceiling rose to light fitting with twin core cable 23/0.0076 Sqmm complete all as specified and directed. Make :- Crompton and equivalent in Havells / Wipro
Supply and fix Flood light luminaries LED energy saving 50 Watt LED exclusive innovative designed, long life versatile pressure die-cast aluminium IP 65 flood light luminaire high power LED in single peace deep drawn housing complete with all accessories and glass cover with suitable bracket or with grouted spring pressure fastener/steel raw plugs as directed by Engineer in Charge including connection from junction box to light fittings with 2.5 Sqmm 2 single core PVC insulated and unsheathed, multi stranded FRLS copper conductor cable drawn in flexible conduit complete controlled by MCB complete all as specified. Make : Crompton and equivalent in Havells / Wipro
Supply, fix, test and commissioning of energy saving and environment friendly long life LED building security light of 25Watts with high efficient led as lighting source, minimum 2500 Lumens with LED driver made up of pressure die cast aluminium housing and with PC cover as diffuser having top opening, separate driver compartment with IP66 protection and impact resistance of IK07 suitable for operation on AC single phase 220-240 Volt, 50 Hz supply all as per Cat No.ENDURAPEARLSL25WLED757SASYTOPCMP of Havells or techno-commercially equivalent of other specified makes fixed with and including GI pipe bracket made out of 40mm dia light grade pipe of length 1.2 Mtrs, bend to shape 120-130 degree and fixed on wall with 2 Nos MS clamps made out of 25x3mm flat iron painted with two coats of synthetic enamel paints over a coat of red oxide primer including nuts, bolts and washers etc., and making connections through and including flexible conduit from ceiling rose to fitting etc., complete all as specified and as directed.
Supply and fix Sheet metal enclosure (DB) Single Pole and neutral 8 way, 240 Volt with 200 Amps rated bus bar double door complete including taking down old unserviceable DB with all accessories complete all as specified and as directed.
Supply and fix SPN 40 Amps, complete all as specified and as directed.
Supply, fix, connecting and testing MCB, Single Pole (SP), 6-32 Amps, 240 volts of rupturing capacity 10kA, C series type all as per Cat No.AU10S10323C of L&T or techno-commercially equivalent of other specified makes complete all as specified and as directed.
Supply and fix MCB TP 63 Amps complete all as specified and as directed.
Supply and fix MCCB TP 125 Amps,415V,16KA complete all as specified and as directed.
Supply and fix MCCB TP 160 Amps,415V,16KA complete all as specified and as directed.
Supply and fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps complete all as specified and as directed.
Supply, fix, connecting and testing factory made, vertical distribution board (MCCB DB), IP 43, IK-09, metal double door, TPN, 4 way, 415 Volts, flush type made out of 1.2mm thick CRCA sheet metal, duly powder coated and conforming to IS 8623 suitable for 3/4 pole MCCBs as incomer, fitted with suitable bus bar, neutral links, blanking plate etc., all as per Cat No.DBVTL004DD of L&T or techno-commercially equivalent of other specified makes, concealed and fixed flush to wall and making good the disturbed surfaces complete all as specified and as directed. Note :- The unit rate quoted shall be deemed to include the cost of cutting chases into walls for concealing MCCB DB and making good the disturbed surfaces with cement work and finishing the surfaces to match with the existing surface.
Taking down unserviceable ceiling fan from site and re-fixing in position duly rectifying the defects (replacing of ball and bearing, oiling / greasing, winding etc.) and make it serviceable in all respect including painting and marking MES No complete all as specified and as directed by Engineer in Charge.
Taking down unserviceable ceiling fan from site and re-fixing in position duly rectifying the defects and servicing (replacing of ball and bearing, oiling / greasing etc.) and make it serviceable in all respect including painting and marking MES No complete all as specified and as directed by Engineer in Charge.
Taking down unserviceable Air circulator wall mounted/Exhaust fan from site and re-fixing in position duly rectifying the defects (replacing of ball and bearing, oiling / greasing, winding etc.) and make it serviceable in all respect including painting and marking MES No complete all as specified and as directed by Engineer in Charge.
Taking down unserviceable Air circulator wall mounted/Exhaust fan from site and re-fixing in position duly rectifying the defects and servicing (replacing of ball and bearing, oiling / greasing, etc.) and make it serviceable in all respect including painting and marking MES No complete all as specified and as directed .
Supply and fix wall mounted turbo force air circulator fan of 450 mm sweep 230 V ,50 Hz, including clamps, nuts and bolts etc. all as specified and as directed. Make :- Usha and equivalent Bajaj/Crompton/Havells
Supply and fix for heavy-duty Exhaust fan of size 450mm sweep,1400 RPM, turbo force model with louvers and all fitting accessories including surface and wall opening with modification for fixing of exhaust fan complete all as specified.
Taking down carefully Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 4/2 runs of 6 Sq.mm/10 sqmm removing materials from site, taken as credit , making good the disturbed surfaces all as specified and as directed.
Material and Labour for wiring for circuit / power /sub main with two runs of single core 4 Sqmm size and one run of single core 4.0 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multi stranded copper conductor FRLSH cable drawn through and including steel conduit suitable dia for 4 sqmm submain wiring with complete fixing accessories complete all as specified and as directed.
Material and Labour for wiring for circuit / power /sub main with two runs of single core 4 Sqmm size and one run of single core 4.0 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multi stranded copper conductor FRLSH cable drawn through and including PVC conduit suitable dia for 4 sqmm submain wiring with complete fixing accessories complete all as specified and as directed.
Material and Labour for wiring for circuit / power /sub main with two runs of single core 6 Sqmm size and one run of single core 6.0 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multi stranded copper conductor FRLSH cable drawn through and including steel conduit suitable dia for 6 sqmm submain wiring with complete fixing accessories complete all as specified and as directed.
Material and Labour for wiring for circuit / power /sub main with two runs of single core 6 Sqmm size and one run of single core 6.0 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multi stranded copper conductor FRLSH cable drawn through and including PVC conduit suitable dia for 6 sqmm submain wiring with complete fixing accessories complete all as specified and as directed.
Material and Labour for wiring for circuit / power /sub main with four runs of single core 10 Sqmm size and two run of single core10.0 Sqmm (green colour as earth continuity conductor) PVC insulated, FRLSH unsheathed, multi stranded copper conductor cable drawn through and including Steel conduit suitable dia for four runs of 10 sqmm submain wiring with complete fixing accessories complete all as specified and as directed.
Material and Labour for wiring for circuit / power /sub main with four runs of single core 10 Sqmm size and two run of single core10.0 Sqmm (green colour as earth continuity conductor) PVC insulated, FRLSH unsheathed, multi stranded copper conductor cable drawn through and including PVC conduit suitable dia for four runs of 10 sqmm submain wiring with complete fixing accessories complete all as specified and as directed.
Taking down carefully main cable for load line DB with XLPE aluminum conductor cables up to 25 Sqmm 4 core removing materials from site, taken as credit , making good the disturbed surfaces all as specified and as directed.
Supply and fixed on wall or steel trusses for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core including fixing materials like lugs, cable glands etc complete all as specified and directed.
Supply and fixed on wall or steel trusses for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including fixing materials like lugs, cable glands etc complete all as specified and directed.
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire complete all as specified and directed .
Material and labour for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) including dismantling of existing unserviceable earth pit all as specified and directed
Taking out old existing LT 1100 volt grade cable, size 10 Sqmm to 50 Sqmm, aluminium conductor 2/4 core, XLPE, armoured, laid in trenches, including bricks for protection, and stacking, removal to store for re-use or for credit, complete all as specified and directed.
Supply and laid in trenches/floors or fixed on wall for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 core including fixing materials like lugs, cable glands etc complete all as specified and directed.
Supply and laid in trenches/floors or fixed on wall for cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including fixing materials like lugs, cable glands etc complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m deep for laying of cable etc and getting out all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified.
Removal of surplus soil to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 above the starting point complete all as directed.
Material and labour for Spreading of crushed stone dust/M-sand in trenches for underground cable including punning down of sand in layer complete all as specified and directed. Note :- Thickness of sand cushion after punning down i.e 18 Cm shall be measured for payment
Supply and laying for sub class ‘B’ bricks , laid flat and dry perpendicular to the direction of cable adjacent to each other ,in trench over the cable for protection complete all as specified.
Material and labour for Spreading of crushed stone dust/M-sand in trenches for underground cable including punning down of sand in layer complete all as specified and directed. Note :- Thickness of sand cushion after punning down i.e 18 Cm shall be measured for payment
Material and labour for GI tubing light grade laid in trenches, in floors, on wall and road crossing for cable protection of size 50 mm dia complete all as specified and directed.
SAMYDOSS CONSTRUCTIONS
PSK Enterprises
muthu constructions
SREE BALAJI ENTERPRISES
C R R CONSTRUCTIONS
RAVI ENTERPRISE
P S G CONSTRUCTIONS
D Subramani and Sons
DANUSH INTERIORS AND CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .