| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹76.8 LAccepted-AOC | L-1 | Accepted-AOC Found L-1 | |
| 2 | L-2₹80.0 L+₹2.9 L (3.75%)Rejected-AOC | L-2 | Rejected-AOC Not found L-1 | |
| 3 | L-3₹80.8 L+₹3.7 L (4.85%)Rejected-AOC | L-3 | Rejected-AOC Not found L-1 | |
| 4 | L-4₹87.7 L+₹10.6 L (13.8%)Rejected-AOC VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L-4 | Rejected-AOC Not found L-1 | |
| 5 | L-5₹88.0 L+₹10.9 L (14.1%)Rejected-AOC | L-5 | Rejected-AOC Not found L-1 |
Tender Value
₹1.0 Cr
EMD Value
₹1.4 L
Closing Date
6 Sept 2021, 5:00 pmClosed
Executive Engineer Jal Shakti Divn No.1 Una HP
Executive Engineer Jal Shakti Divn No.1 Una HP
(SH Laying, jointing and testing of Rising main, Supply and errection of pumping machinery along with allied accessories and construction of civil work)
2021_HPIPH_51548_1
No. JSV-I/TA/E-tender/21-6786-6810 dt 21-8-21
Open Tender
Civil Works
Item Rate
180 days
village Kuthar Kalan, Sunehra and Aug. of WSS Sant
as per NIT
9 documents required · 9 mandatory
₹1,500
Yes
Executive Engineer Jal Shakti Divn No.1 Una HP
₹1.4 L
Yes
20 Jan 2022
23 Aug 2021
7 Sept 2021
23 Aug 2021
6 Sept 2021
23 Aug 2021
23 Aug 2021 - 6 Sept 2021
Amount
Excavation in foundation trenches ( for pipes and pits ) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft / hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including, shoring, strutting, planking, timbering and dewatering, wherever required, stacking the useable and unuseable material/ soil separately and after laying, jointing and testing of pipes returing the useable soil in trenches in 15 cm ( Fifteen centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil /un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts as per the directions of Engineer-in-Charge.
Laying, jointing and testing in trenches plain ended GMS flanged pipes (Medium grade) of following dia confirming to ISI (1239-2004) specification including commissioning and cost of all fittings i.e. bends, tail pieces, tees & other special manufacturing from parent pipes as applicable to the particular reach & of approved/sepecification as per site condition and cutting of pipes where ever required as per site requirement in respect of following diameters in Rising Main ( The earth work in trenches shall be measured and paid for separately ) including entire carriage of material in all leads and lifts as per the direction of the Engineer-in-Charge.
80mm dia (M)
125mm dia (M)
150mm dia (M)
Providing & fixing and welding of M.S.flanges conforming to BIS-6392-1971 (latest with upto date ammendments) welding of MS flanges on three Layers (one layer on inner face and two layers on outer face of each flange) GMS pipe and bends on both end (the cost of GMS pipe and laying to be measured & paid separately) accordingly to relevent BIS and detailed specification & fixed with nuts, bolts of required size and synthetic rubber gasket conforming relevant BIS code as given in the technical specification including all kinds of leads and lifts and entire satisfaction of the engineer- in- Charge
80mm dia T-17
125mm dia T-5
150mm dia T-5
Providing circumferencial butt welded joints by electrical arc welding to following dia & class pipes,welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS- 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes in all leads and lifts to the entire satisfaction of Engineer- in- charge.
80mm dia
125mm dia
150mm dia
S/E of Submersible Pumping Machinery (Kuthar Kalan) Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 4.04 LPS
Total Head ( H ) 82.69 Mts.
a) SWL in Tubewell =10.00 Mtr. bgl.
c) R.L. point of discharge = 337.50Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.0 Mtrs.
e) Drawdown in Tubewell 7.62 Mtrs.
f) R.L of lowest point of pumpset installation = 273.38 Mtrs.
g) Static Column lift = 26.62 Mtrs.
Rising main. Column Pipe.
Length 895 Mtrs. Length 36.62 mtrr.
Dia meter 80 mm Dia 80 mm
Class GMS ( M) Class GMS. (M)
Pumping hours 20 hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells /Standard/ Kilburn Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity :32 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing.ii) layout Plan.
a) MCB of kilburn / L&T/ Havells/Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 32 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB i) Make. ii) Type iii) Range. 100Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 3 KVAR
Providing suitable oil immeresed star delta starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP Brand make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 80 mm dia Sluice valve i) Make ii) Class PN 1.60 iii) Material cast iron
Providing and fixing double flanged Cast Iron Reflux valve of Leader / Kirloskar/Kartar/LP brand make having by pass arrangement on the delivery line of pump and capable of withstanding the normal seat pressure and as per IS 6312-1984 P-I with latest ammendments 80 mm dia Sluice valve i) Make ii) Class PN 1.60 iii) Material cast iron
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 4mm2 (iii) Core=3
Lowering of GMS Column pipe for assembly 80 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Each) at the top of T/well assembly, and as per the direction of Engineer - in - Charge.( The pipe shall be supplied by the department free of cost from Divisional store Malahat ) Column pipe i) Size 80 mm dia ii) Class (M) iii) Length
Installation of all items appearing at S.No 5 to 21 as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar 4mm sq and Switch to starter i) Size 2.5 mm2 ii) Make iii) Type iv) Capacity v) core 3
Providing and fixing double loop earthing with GI plate of 20x3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt 25x5 mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI Flat 25x3mm 15HP to 50 HP
S/E of Submersible Pumping Machinery (Santokhgarh Zone)-A Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 10.25 LPS
Total Head ( H ) 51.76 Mts.
a) SWL in Tubewell =3.00 Mtr. bgl.
c) R.L. point of discharge = 424.05Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.0 Mtrs.
e) Drawdown in Tubewell 12 Mtrs.
f) R.L of lowest point of pumpset installation = 376.10 Mtrs.
g) Static Column lift = 24 Mtrs.
Rising main. Column Pipe.
Length 30 Mtrs. Length 34 mtrr.
Dia meter 125 mm Dia 125 mm
Class GMS ( M) Class GMS. (M)
Pumping hours 12 hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells /Standard/ Kilburn Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity :63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing.ii) layout Plan.
a) MCB of kilburn / L&T/ Havells/Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 63 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB i) Make. ii) Type iii) Range. 100Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 4 KVAR
Providing suitable oil immeresed star delta starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP Brand make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing double flanged Cast Iron Reflux valve of Leader / Kirloskar/Kartar/LP brand make having by pass arrangement on the delivery line of pump and capable of withstanding the normal seat pressure and as per IS 6312-1984 P-I with latest ammendments 125 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 4mm2 (iii) Core=3
Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Each) at the top of T/well assembly, and as per the direction of Engineer - in - Charge.( The pipe shall be supplied by the department free of cost from Divisional store Malahat ) Column pipe i) Size 125 mm dia ii) Class (M) iii) Length
Installation of all items appearing at S.No 25 to 41 as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar 4mm sq and Switch to starter i) Size 2.5 mm2 ii) Make iii) Type iv) Capacity v) core 3
Providing and fixing double loop earthing with GI plate of 20x3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt 25x5 mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI Flat 25x3mm 15HP to 50 HP
S/E of Submersible Pumping Machinery (Santokhgarh Zone-B) Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 16.15 LPS
Total Head ( H ) 60.84 Mts.
a) SWL in Tubewell =3.00 Mtr. bgl.
c) R.L. point of discharge = 431.95Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.0 Mtrs.
e) Drawdown in Tubewell 12 Mtrs.
f) R.L of lowest point of pumpset installation = 376.10 Mtrs.
g) Static Column lift = 24 Mtrs.
Rising main. Column Pipe.
Length 85 Mtrs. Length 34 mtrr.
Dia meter 150 mm Dia 125 mm
Class GMS ( M) Class GMS. (M)
Pumping hours 16 hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells /Standard/ Kilburn Siemens make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity :63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing.ii) layout Plan.
a) MCB of kilburn / L&T/ Havells/Standard make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 63 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB i) Make. ii) Type iii) Range. 63Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 6 KVAR
Providing suitable oil immeresed star delta starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP Brand make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing double flanged Cast Iron Reflux valve of Leader / Kirloskar/Kartar/LP brand make having by pass arrangement on the delivery line of pump and capable of withstanding the normal seat pressure and as per IS 6312-1984 P-I with latest ammendments 150 mm dia Reflux valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 6mm2 (iii) Core=3
Lowering of GMS Column pipe for assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Each) at the top of T/well assembly, and as per the direction of Engineer - in - Charge.( The pipe shall be supplied by the department free of cost from Divisional store Malahat ) Column pipe i) Size 125 mm dia ii) Class (M) iii) Length
Installation of all items appearing at S.No 45 to 61 as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar 16mm sq and Switch to starter i) Size 6mm2 ii) Make iii) Type iv) Capacity v) core 3
Providing and fixing double loop earthing with GI plate of 20x3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt 25x5 mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI Flat 25x3mm 15HP to 50 HP
Pump House and boundary wall
Excavation in foundation in trenches in earth work in pick work, jumper work within all leads and lifts and lift stacking the excavated soil not more than 3 mtr clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc., consolidating each deposted layer by ramming, watering, and then disposing of all surplus excavated earth as directed within all leads and lifts as per the direction of Engineer-in-charge.
Excavation in earth work and filling in 15 cm. layers in foundation and plinths including ramming, watering and consolidating in all leads and lift to the entire satisfaction of Engineer-in-charge in foundation and plinths.
Providing, laying cement concrete 1:6:12(1cement:6sand)12graded stone agg., 40mm nominal size)& curing complete excluding the cost of form work in foundation and plinths in all leads and lift to the entire satisfaction of Engineer-in-charge.
Ist class brick work using common burnt clay building bricks of appraoved quality in foundation and plinth in cement mortar 1:6 (1cement:6sand) in all leads and lift to the entire satisfaction of Engineer-in-charge.
Ist class brick work using common burnt clay building bricks of approved quality in super structure in cement mortar 1:6(1cement:6sand) in all leads and lift to the entire satisfaction of Engineer-in-charge.
Half brick work using common burnt clay building bricks in super structure above 1st. floor level in cement mortar 1 : 4 ( 1 cement :4 sand) of Ist Class bricks complete in all lead and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb lock, jamb beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel but things 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreatment of the surface in all leads and lift to the entire satisfaction of Engineer-in-charge.
Profile-A
Profile-B
Providing and fixing, panelled glazed or panelled & glazed shutter for doors, windows & clearstory windows including bright finished black enamelled from butt hings with necessary screw in all leads and lift to the entire satisfaction of Engineer-in-charge. 2nd class deodar wood 40mm thick.
Providing and laying cement concrete 1:1.5:3 ( 1cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:
Foundation, footing and bases of columns etc. and mass concrete within all leads and lifts complete in all respect i/c carriage of materials with in all leads and lifts.
Suspended floor,roofs,landing & shelves & their support balconies,beams,girders,bressumers & cantilever upto floor level within all leads and lifts as per direction of Engineer-in-charge.
Providing form work with steel plate 3.15 mm thick welded with angle iron frame 30x30x5mm so as give a fair finish including centring, shuttering, strutting and propping etc with wooden battens and ballies, height of propping and centring below supporting floor to ceiling upto any height and removal of the same for in site-reinforced concrete and plain concrete work in
Flat surfaces, such as soffits of suspended floors, roofs, landing and the like floor etc upto 200mm inthickness within all leads and lifts as per direction of Engineer-in-charge.
Beams, cantilever, girders and lintles sides and soffits of beams haunching cantilever girders, bressumers and lintles not exceeding 1.0 mtr in depth in all leads and lift to the entire satisfaction of Engineer-in-charge.
Providing and laying cement concrete flooring 1:2:4(1cement:2sand:4graded stone agg., 20mm nominal size) laid in one layer finished with a floating coat of neat cement within all leads and lifts as per direction of Engineer-in-charge.
40mm thick.
25mm thick.
15 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:6 ( 1 cement :6 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.
Pointing on brick work with cement mortar 1:3(1cement:3sand) raised and cut point within all leads and lifts as per direction of Engineer-in-charge.
Providing plinth protection 50mm thick cement concrete 1:3:6(1cement:3asand:6graded stone aggregate., 20mm nominal size) including finishing the top surface concrete smooth within all leads and lifts as per direction of Engineer-in-charge.
Applying priming coat over new wood & wood based surfaces after and including preparing the surface by thoroughly cleaning oil grease dirt & other foreign matter) sand papering & knotting ready mixed paint brushing wood primer pink within all leads and lifts as per direction of Engineer-in-charge..
Painting two coats(excluding priming coat) on new wood and wood surface with ready mixed paint brushing to give an even shade including cleaning of all dirt, dust & other foreign matter sand papering and stopping with ready mix paint other than white within all leads and lifts as per direction of Engineer-in-charge.
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with enamel paint other than white complete in all respect as per the direction of the Engineer-in-Charge.
White washing with lime on underocated surfaces (two coats) to give an even shade including thoroughly bromming the surface to remove all dirt, dust mortar dirt and other foreign matter within all leads and lifts as per direction of Engineer-in-charge.
Hirmachi colour wash on undecorated wall surfaces(Two coat) to give an even shade including thoroughly brooming the surfaces to remove all dirt, dust. mortar drops and other foreign matter within all leads and lifts as per direction of Engineer-in-charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces(two coats)to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered material complete within all leads and lifts as per direction of Engineer-in-charge..
Providing and fixing MS grill of required pattern in wooden frames / pressed steel frames of windows etc. with M.S. Flat square or rounded bar 12mm dia round headed bolts and nuts or by screws and or square bars, ruled spacing to wooden frames windows and clearstory windows etc within all leads and lifts as per direction of Engineer-in-charge.
Providing tor steel reinforcement for reinforced concrete work including bending, binding, & placing in position complete upto floor two level within all leads and lifts as per direction of Engineer-in-charge.
Providing and fixing 40x3mm flat iron hold fast 40cm long including fixing to frames with 10mm dia meter bolts, nuts & wooden plugs and emedding in cement concrete block 30x10x15cm 1:3:6(1cement:3sand:6 graded stone agg., 20mm nominal size) within all leads and lifts as per direction of Engineer-in-charge.
Providing and fixing alluminium sliding door bolts anodized colour & shade with bolts and nuts screw etc., (250x16mm) complete within all leads and lifts as per direction of Engineer-in-charge.
Providing and fixing alluminium tower bolts barrel type anodized transparent all dyed to required shade & colour with screw within all leads and lifts as per direction of Engineer-in-charge.
Providing and fixing alluminium handles anodized transparent or dyed to required colour or shade with necessary screw etc., complete 100mm.
Providing and fixing MS fan clamps type-I of 16mm dia MS barbent to shape with hooked ends in RCC slab during laying including painting the exposed position of loop, all as per standard design
Steel work welded in built up sections,trusses & framed work i/c cutting,hoisting & fixing in position & applying a priming coat of red paint In grating, framed ,guards,bars,ladders, railing, brackets & similar works within all leads and lifts as per direction of Engineer-in-charge.
Over Head Service Reservoir
Excavation in foundations, trenches etc., in earth work. In all kind of soil such as spade work, pick work, jumper work, blasting work in soft and hard rock chiselling / wedging out of rock where blasting is prohibited and in saturated soil etc. in all leads and lifts, stacking the excavated soil not more than 3 metres clear from the edge of excavation and then returning the stacked soil in fifteen centimetre layers,when required into plinths sides of foundations etc. consolidating each deposited layer by ramming and dewatering and then disposing of all surplus excavated earth as directed within all leads and lifts as per direction of the Engineer-in-Charge.
Providing and laying cement concrete 1: 3 :6 ( 1 cement :3 sand :6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing and laying cement concrete M-30 (not leaner than 1:1.5:3) mix concrete using crushed stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reingorcement for reinforced concrete work in:
Foundation, footing bases of columns and the like and mass concrete.
Columns pillars,post and struts.
Lintels, beams,girders,bressumer and cantilever.
Stair case(except spiral stair case)excluding landing but including preparing of the surface and finishing of nosing.
Arches upto all heights.
Suspended floor roofs, landing and shelves and their support balconies, beam girderes bressumers and cantiliver.
Wall ( any thickness but not less than 0.10 mtrs thickness attached pilasters butteress, plinth and string courses etc. from top of foundation level.
From four level to five level
From five level to six level
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30 x 30 x 5 mm, so as to give a fair finish including centring , shuttering, strutting and propping etc with wooden battans and ballies height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu-reinforced concrete and plain concrete work in all leads and lifts & as per the direction of the Engineer-in-Charge.
Foundation , footings , basis of columns etc. and mass concrete.
Columns,pillars posts,struts circular or curved in plan.
Sides and soffits of beams,beam haunching , cantiliver,bressumers & lintle not exceeding 1.00 mtr. Depth in all height. of floors.
Vertical surfaces such as wall of (any thickness), partitions and the like inculding attached pillasters,buttresses, plinth and string courses and the like..
Sloping or battering surface i/c folded plates where inclination to horizontal plan exceed 30 deg (where shuttering may be provided both on underside and upperside if reqd only the area of under side shall be measured for payment.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like.upto 200 mm thickness.
Stair cases with slopping or stepped soffits excluding landings.
Providing of form work of ordinary timber planking so as to give a rough finish including centering, shuttering , strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 6 mtrs. and removal of the same insitu reinforced concrete and plain concrete work in all leads and lifts and as per the direction of the Engineer- in - Charge in Arches not exceeding 6 mtrs span.
Steel work welded in built up section , trusses and framed work i/c cutting hoisting fixing in position and applying a priming coat of red lead paint in gretings, framed guards, bors ladders railing brackets and similar works.
Providing Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete in all respect in all leads and lifts & as per direction of the Engineer-in-Charge floor two level.
Providing plinth protection 50 mm thick in cement concrete 1: 3: 6 (1cement : 3 sand : 6 graded stone aggregate 20 mm nominal size ) including entire carriage of material and as per direction of the Engineer-in-Charge.
Providing under layer for plinth protection of 75 mm thick ( unconsolidated )bed dry brick/ stone aggregaated 40 mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground.
Providing and fixing MS manhole cover of 500 mm dia with frame ( medium grade duty ) weight of cover and frame to be not less than 23 kg.
Fixing inlet, outlet, over flow and Scour pipe of GMS pipe of following internal dia ( medium grade)i/c extra carriage within all leads and lifts and as per the direction of the Engineer-in-Charge.
Inlet R/main 80 mm.
Inlet R/main 125 mm.
Inlet R/main 150 mm.
Out let pipe 100 mm ( Distribution )
Over flow & scour pipe 80 mm dia
Providing ,fixing and welding of MS flanges conforming to IS code 6392-1971 table 5 of below noted diameter ( Latest with upto date ammendments ) welding of M.S. flanges on G.I. pipe on both ends according to relevent BIS standard and detailed technical specification ) and provided with nuts,bolts of required size complete in all respect and as per diection of the Engineer-in-Charge.
Inlet R/main 80 mm.
Inlet R/main 125 mm.
Inlet R/main 150 mm.
Out let pipe 100 mm ( Distribution )
Over flow & scour pipe 80 mm dia
Providing and fixing C.I.sluice valve ( With hand whell ) as per IS 780 class for following dia ( including brass spindle and as per IS 2906 class-II including MS Flange, bolts, nuts, rubber insertion etc. complete in all respect i/c carriage of material within all leads and lifts.
Out let pipe 100 mm ( Distribution )
Scour pipe 80 mm
P/F of water measuring gauge of standard design complete in all respect.
Providing and fixing sky lightening arrestot complete in all respect in all leads and lifts i/c carriage as per the direction of the Engineer-in-Charge.
Providing and fixing vent opening including cowl with mesh in the top of the tank i/c carriage all leads and lifts and as per the direction of the Engineer-in-charge.
Finshing wall with water proofing cement paint of approved brand & manufacturer & of required shade on undecorated wall surfaces ( Two coats) to give an even shade after throughly brushing the surfaces to remove all dirt, dust and remain of loose powdered material. in all leads and lifts and as per the dirction of the Engineer- in - charge.
aditya govt. contractor
ADITYA KHAZANCHI
Sushant Puri
M/S. Mast Ram Jaswal And Co.
Ashwani Kumar Govt Contractor
Pawan Kumar Sharma Govt Contractor
SHIV KANT PRASHAR
Deepankar Singh Kanwar
R D Eco Paryavaran
Dogra Construction Company Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .