Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹13.9 LAdmitted-Finance | +3.59% | ₹13.9 L | L1 | Admitted-Finance |
| 2 | L2₹14.2 LAdmitted-Finance | +6.00% | ₹14.2 L | L2 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹26,872
Closing Date
16 Apr 2026, 4:00 pmClosed
Er. Balbir Singh, Executive Engineer (E)BM-I
3rd Floor Mohan Singh Place BKS Marg Connaught Place New Delhi
As per NIT
2026_NDMC_289622_1
NIT No. 85/EE(BM-I)/2025-26
Open Tender
Electrical Works
365 days
in NDMC area under BM-I(E) Division New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹26,872
16 May 2026
7 Apr 2026
16 Apr 2026
7 Apr 2026
16 Apr 2026
7 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying and charging of R-134 A/R-410 Non CFC gas in the following capacity WTAC/ STAC and water Coolers after pressure testing with nitrogen gas, vacuuming etc. including providing capillary filter of suitable size etc. as required (Gas will be supplied by the contractor) a) 1 Tr. Capacity Water cooler | |||||
| 1.1 | b) 1.5 Tr. Capacity WTAC/ STAC | - | Nos. | - | - |
| 1.2 | c) 2/2.5 Tr. Capacity WTAC/ STAC | - | Nos. | - | - |
| 1.3 | d) Fridge 160 to 300 ltrs. Capacity | - | Nos. | - | - |
| 2Supplying, installation, testing and commissioning of following capacity of compressor (make: Emerson/ Highly) in existing ACs and water coolers installed at various locations in NDMC area on exchange basis including connection with suitable size of suction and discharge copper pipe, copper strainer, capillary, nut- bolts, anti-vibration pad , connection, interconnection all the electrical wiring with thimbles cleaning and leakage / pressure testing gas for 24 Hrs. vacuuming, charging with refrigerant, (gas will be supplied by the contractor ) including dismantling of defective compressor etc. as required at site of work. Capacity 1 Tr. Reciprocating type | |||||
| 2.1 | Capacity 1.5 Tr. Reciprocating type | - | Nos. | - | - |
| 2.2 | Capacity 1.5 Tr. Rotary type | - | Nos. | - | - |
| 2.3 | Capacity 2 Tr. Reciprocating type | - | Nos. | - | - |
| 2.4 | Capacity 2 Tr. Rotary type | - | Nos. | - | - |
| 3Replacement of defective compressor of compressor of fridge on exchange basis with new company make including gas charging, brazing of suction and discharge lines, supplying and replacement of capillary strainer, pressure testing , vacuuming etc. in fridges of capacity 165 to 500 ltrs. at various locations in NDMC area. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.81 MB
BOQ_384637.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid