| Sl No | Description | Qty | Unit | M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR L2 | M/S N A Enterprises L1 | M/S HAMIDULLAH KHUROO L3 |
|---|---|---|---|---|---|---|
| 1.00 | S&F in replacement Sheet metal enclosure factory made (double door) shutter type, MCB DB TPN horizontal type, 440 Volts, 4 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed. | 8 | Each | 700 ₹5,600 | 2,400 ₹19,200 | 400 ₹3,200 Lowest |
| 2.00 | S&F in replacement Sheet metal enclosure factory made (double door) shutter type, MCB DB SPN, 240 Volts, 12 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed. | 8 | Each | 1,000 ₹8,000 | 1,200 ₹9,600 | 800 ₹6,400 Lowest |
| 3.00 | S&F in replacement Sheet metal enclosure factory made (double door) shutter type, MCB DB SPN, 240 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed. | 12 | Each | 900 ₹10,800 | 1,000 ₹12,000 | 600 ₹7,200 Lowest |
| 4.00 | S&F in replacement MCB SPN, 40 to 63 Amp, 10KA, 240 Volts, complete all as specified and directed. | 32 | Each | 500 ₹16,000 | 500 ₹16,000 | 400 ₹12,800 Lowest |
| 5.00 | S&F in replacement MCB SP ,6 to 32 Amp, 10KA, 240 Volts, complete all as specified and directed. | 72 | Each | 150 ₹10,800 Lowest | 220 ₹15,840 | 150 ₹10,800 Lowest |
| 6.00 | M&L in replacement Sub main wiring of two single core PVC insulated and unsheathed cable with 6 sqmm FRLS multi-stranded copper conductor drawing in PVC casing caping/PVC conduit as per site requirement including PVC bend,corner junction etc with 6 Sqmm PVC unsheathed copper conductor (multi-stranded) as continuous earth wire including taking down existing wiring complete all as specified and directed. | 248 | RM | 200 ₹49,600 | 130 ₹32,240 | 120 ₹29,760 Lowest |
| 7.00 | M & L for fixing Air termination lightening conductor single pointed copper rod 12mm dia and 300mm long fixed properly on top of the Hangers/ATC building complete all as specified and directed. | 15 | Each | 5,000 ₹75,000 | 1,800 ₹27,000 | 800 ₹12,000 Lowest |
| 8.00 | M & L for making of test point terminal Block made out of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexa head screw complete all as directed. | 15 | Each | 1,500 ₹22,500 | 500 ₹7,500 | 300 ₹4,500 Lowest |
| 9.00 | M & L for fixing in replacement of copper strip of size 20mm x 3.15mm thick with and including saddles and fixing screws etc for roof conductor or down conductor above ground complete all as specified and directed. | 60 | RM | 650 ₹39,000 | 800 ₹48,000 | 100 ₹6,000 Lowest |
| 10.00 | Earthing complete with copper earth plate 60 cm x 60 cm x 3.15 mm thick electrode burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5M below normal GL connected to copper strip 20 x 3 mm as earthing strip lead by means of nut,bolts and check nut and washer, GI light grade protection pipe 25 mm dia. upto 7.5 m, GI watering pipe 20 mm dia, RCC cover with funnel,excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 3 of SSR Part I, including earth test point up to pannel board,all as specified or indicated including testing on completion, complete all as specified and directed. | 15 | Each set | 9,500 ₹1,42,500 Lowest | 11,000 ₹1,65,000 | 14,000 ₹2,10,000 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
21 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CIF K
AGE I CIF K Co 56 APO
REPAIR AND MAINT OF CHANGEOVER SWITCH, EARTHING AND LIGHTENING CONDUCTOR OF OTM AND MD ACCN AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2025_MES_721340_1
AGE (I) CIF (K) - 41/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Shalateng Garrison
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE I CIF K
₹20,000
20 Sept 2025
19 Jul 2025
23 Aug 2025
19 Jul 2025
21 Aug 2025
2 Aug 2025
Amount
S&F in replacement Sheet metal enclosure factory made (double door) shutter type, MCB DB TPN horizontal type, 440 Volts, 4 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed.
S&F in replacement Sheet metal enclosure factory made (double door) shutter type, MCB DB SPN, 240 Volts, 12 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed.
S&F in replacement Sheet metal enclosure factory made (double door) shutter type, MCB DB SPN, 240 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and directed.
S&F in replacement MCB SPN, 40 to 63 Amp, 10KA, 240 Volts, complete all as specified and directed.
S&F in replacement MCB SP ,6 to 32 Amp, 10KA, 240 Volts, complete all as specified and directed.
M&L in replacement Sub main wiring of two single core PVC insulated and unsheathed cable with 6 sqmm FRLS multi-stranded copper conductor drawing in PVC casing caping/PVC conduit as per site requirement including PVC bend,corner junction etc with 6 Sqmm PVC unsheathed copper conductor (multi-stranded) as continuous earth wire including taking down existing wiring complete all as specified and directed.
M & L for fixing Air termination lightening conductor single pointed copper rod 12mm dia and 300mm long fixed properly on top of the Hangers/ATC building complete all as specified and directed.
M & L for making of test point terminal Block made out of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexa head screw complete all as directed.
M & L for fixing in replacement of copper strip of size 20mm x 3.15mm thick with and including saddles and fixing screws etc for roof conductor or down conductor above ground complete all as specified and directed.
Earthing complete with copper earth plate 60 cm x 60 cm x 3.15 mm thick electrode burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5M below normal GL connected to copper strip 20 x 3 mm as earthing strip lead by means of nut,bolts and check nut and washer, GI light grade protection pipe 25 mm dia. upto 7.5 m, GI watering pipe 20 mm dia, RCC cover with funnel,excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 3 of SSR Part I, including earth test point up to pannel board,all as specified or indicated including testing on completion, complete all as specified and directed.
S & F in replacement on Load changeover switch, 4 Pole, 100 AMPS, I-O-II OPEN EXECUTION Euroload changeover switch, complete all as specified and directed.
Supply and laying, testing, jointing including taking out and removing old unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core in trenches, through pipe, under culvert or in air, complete all as specified and directed.
Excavation in trenches in soft / loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr deep and getting out complete, all as specified.
Returning filling in including spreading, leveling, watering and well ramming to a layer not exceeding 25cm, complete all as specified and directed.
Removal of excavated material not exceeding 50mtr and depositing where directed at a level not exe 1.5 mtr above the starting point.
Sand cushioning to under ground cable using fine sand (8 cm before & 15 cm after laying of cable) complete all as specified. NOTE :- Punned thickness shall be measured for payment purpose.
Brick sub class 'B' of standard size for protection of cable, brick laid across the cable all as specified and directed.
S & F in replacement on Load changeover switch, 4 Pole, 325 AMPS, I-O-II OPEN EXECUTION Euroload changeover switch, complete all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed.
Supply, fixing & laying GI pipe light grade 40 mm bore in trench, under floor, wall or on pole for cable protection, complete all as specified including taking down old unserviceable.
Note :- An amount of Rs. Rs 23,018.00 on account of credit schdule for Sch 'A' Part-II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR (BID ID -3396170)
M/S HAMIDULLAH KHUROO (BID ID -3397985)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .