Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC BHITERLEY VPO BAHU AKBARPUR ROHTAK | ROHTAK | ROHTAK | HARYANA | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.1 L+₹43,896.35 (2.63%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.7 L+₹1.0 L (6.06%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-rejected |
Tender Value
₹19.9 L
EMD Value
₹39,760
Closing Date
17 Aug 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
JAGDISH SINGH DAHIYA
Engg. Cell, MDU, Rohtak
Repair of Damaged concrete surface columns/Beams of Commerce dept., English dept., Chemistry dept., Distance and UIET Workshop Building in MDU Rohtak
2023_HRY_300088_1
20234024C326 1A51 470A 8503 652D6BD72D7E817MDU
Open Tender
Civil Works
Works
30 days
Rohtak
Repair of Damaged concrete surface columns/Beams of Commerce dept., English dept., Chemistry dept., Distance and UIET Workshop Building in MDU Rohtak
2 documents required · 2 mandatory
₹1,000
Yes
₹39,760
Yes
11 Dec 2023
27 Jul 2023
18 Aug 2023
27 Jul 2023
17 Aug 2023
27 Jul 2023
Amount
[11.8.1]12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand)
[30.16.2]Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 2. With cement mortar 1:4 (1cement: 4 coarse sand)
[30.94]Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, up to 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal and vertical tubes joint with cup and lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
[31.1]Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed and firmly anchored to the concrete surface by means of `L` shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool and plants as approved by Engineer-in-charge.
[31.2.1]Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 1. 75mm average thickness
[31.2.2]Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 2. 50mm average thickness
[31.3.2]Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. 2. Bars above 12 mm diameter
[31.4.1]Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. 1. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
[31.5.2]Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. 2. 75mm thick in Grade M 25 with cement content not less than 330 kg per cum
[31.7.3]Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. 3. 50 mm average thickness in 3 layers.
[5.26]Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts
[7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
The Adhmi Coop Society Ltd
THE RISING STAR CO-OPERTIVE L&C SOCIETY LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .