| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | ₹24.2 L Quoted ₹28.4 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹29.5 L+₹1.1 L (3.78%)Rejected-Finance | ₹29.5 L+₹1.1 L (3.78%) | L2 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | star electricals L2 | ABHOG INFRASTRUCTURE PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Material and Labour for disconnecting defective transformer 33 KV/11 KV of capacity 3150 KVA from foundation and transportation the transformer for repair to authorized workshop/ factory, dismantling the transformer for repair and reassembling the same after repairs checking with phase to phase, phase to neutral with body & neutral earthing for proper result and connecting all connections properly with checking of oil level, silica gel, air release plug, gate valve, drain valve, bushing terminal, tapping changer etc and replacement of unserviceable parts, denting, welding, etc and spray painting with two coats of synthetic enamelled paint (grey paint) including preparation of surface, marking of MES No. with white paint of suitable size and transportation from workshop/ factory to site and re-installed on platform commissioning and testing of transformer upto entire satisfaction of Engineer-in-charge.
Note :- (i) Quoted rate will be inclusive of labour for rewinding of complete transformer.
(ii) Spare parts / transformer oil / copper for rewinding will be measured and paid separately. | 1 | Each Job | 83,000 ₹83,000 | 30,000 ₹30,000 Lowest |
| 2.00 | M&L for taking out unserviceable complete coil on limb and HV winding of transformer 33 KV/11 KV capacity 3150 KVA with suitable size/ existing gauge supper enamelled copper winding wire insulated with necessary insulating material complete all as specified & directed by Engineer-in-charge. | 495 | Kgs | 1,180 ₹5,84,100 Lowest | 1,488 ₹7,36,560 |
| 3.00 | M&L for taking out unserviceable complete coil on limb and LV winding of transformer 33 KV/11 KV capacity 3150 KVA with suitable size/ existing gauge supper enamelled copper winding wire insulated with necessary insulating material complete all as specified & directed by Engineer-in-charge. | 495 | Kgs | 1,180 ₹5,84,100 Lowest | 1,288 ₹6,37,560 |
| 4.00 | M&L for replacement of unserviceable HT bushes insulators of transformer 3150 KVA capacity including brass bush rod/spindle with nuts & wahers complete all as specified & directed by Engineer-in-charge. | 10 | Each | 600 ₹6,000 Lowest | 3,000 ₹30,000 |
| 5.00 | Disconnecting transformer from load of any make,any size and any capacity, draining out transformer oil and regular filtration at location in position at site (on pole / platform) filtration upto required dielectric strength 45-50 KV with the help and drying plant by mechanical machines of suitable capacity to achive including testing of dielectric strength all directed by Engineer-in-Charge. | 6,300 | Ltr | 8 ₹50,400 Lowest | 11 ₹69,300 |
| 6.00 | Supply and topping up / refilling in repair of transformer oil of dielectric strength 50 KV minimum for transformer complete all as specified & directed by Engineer-in-charge. | 1,400 | Ltr | 130 ₹1,82,000 Lowest | 135 ₹1,89,000 |
| 7.00 | M&L for checking, servicing, calibration of 33 KV 3 phase 50 Hz, 630 Amps, 31.5 KA totally enclosed outdoor metal clad VCB, cricuit breaker servicing of numerical relay, master trip relay transformer fault relay, spring charge relay, indication lamps, digital volt & ammeter with selector switch, replacement of required part complete system checking and commencing by technician if necessary requirement all as specified and directed by Engineer-in-Charge. | 4 | Each | 9,000 ₹36,000 Lowest | 15,000 ₹60,000 |
| 8.00 | S&F in repairs of Over Current & Earth Fault relay complete accessories as per existing make and model all as specified and directed by Engr-in-charge. | 3 | Each | 14,000 ₹42,000 | 3,000 ₹9,000 Lowest |
| 9.00 | S&F in repairs digital voltmer 11 KV with selector switch, complete all as specified and as directed by Engr-in-charge. | 1 | Each | 1,200 ₹1,200 Lowest | 1,500 ₹1,500 |
| 10.00 | S&F in repairs digital ammeter 11 KV with selector switch, complete all as specified and as directed by Engr-in-charge. | 1 | Each | 1,200 ₹1,200 Lowest | 1,500 ₹1,500 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Jun 2026, 6:00 pmClosed
CWE (A) JAISALMER
HQ CWE (A) JAISALMER
REPAIR AND MAINT OF 33 KV OH/UG LINES, TRANSFORMERS AND ALLIED WORKS UNDER AGE (I) POKARAN.
2026_MES_767417_1
84429/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
POKARAN
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) POKARAN
₹60,000
Yes
1 Sept 2026
23 May 2026
22 Jun 2026
23 May 2026
20 Jun 2026
13 Jun 2026
23 May 2026 - 6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and Labour for disconnecting defective transformer 33 KV/11 KV of capacity 3150 KVA from foundation and transportation the transformer for repair to authorized workshop/ factory, dismantling the transformer for repair and reassembling the same after repairs checking with phase to phase, phase to neutral with body & neutral earthing for proper result and connecting all connections properly with checking of oil level, silica gel, air release plug, gate valve, drain valve, bushing terminal, tapping changer etc and replacement of unserviceable parts, denting, welding, etc and spray painting with two coats of synthetic enamelled paint (grey paint) including preparation of surface, marking of MES No. with white paint of suitable size and transportation from workshop/ factory to site and re-installed on platform commissioning and testing of transformer upto entire satisfaction of Engineer-in-charge.
Note :- (i) Quoted rate will be inclusive of labour for rewinding of complete transformer.
(ii) Spare parts / transformer oil / copper for rewinding will be measured and paid separately. | 1 | Each Job | - | - |
| 2 | M&L for taking out unserviceable complete coil on limb and HV winding of transformer 33 KV/11 KV capacity 3150 KVA with suitable size/ existing gauge supper enamelled copper winding wire insulated with necessary insulating material complete all as specified & directed by Engineer-in-charge. | 495 | Kgs | - | - |
| 3 | M&L for taking out unserviceable complete coil on limb and LV winding of transformer 33 KV/11 KV capacity 3150 KVA with suitable size/ existing gauge supper enamelled copper winding wire insulated with necessary insulating material complete all as specified & directed by Engineer-in-charge. | 495 | Kgs | - | - |
| 4 | M&L for replacement of unserviceable HT bushes insulators of transformer 3150 KVA capacity including brass bush rod/spindle with nuts & wahers complete all as specified & directed by Engineer-in-charge. | 10 | Each | - | - |
| 5 | Disconnecting transformer from load of any make,any size and any capacity, draining out transformer oil and regular filtration at location in position at site (on pole / platform) filtration upto required dielectric strength 45-50 KV with the help and drying plant by mechanical machines of suitable capacity to achive including testing of dielectric strength all directed by Engineer-in-Charge. | 6,300 | Ltr | - | - |
| 6 | Supply and topping up / refilling in repair of transformer oil of dielectric strength 50 KV minimum for transformer complete all as specified & directed by Engineer-in-charge. | 1,400 | Ltr | - | - |
| 7 | M&L for checking, servicing, calibration of 33 KV 3 phase 50 Hz, 630 Amps, 31.5 KA totally enclosed outdoor metal clad VCB, cricuit breaker servicing of numerical relay, master trip relay transformer fault relay, spring charge relay, indication lamps, digital volt & ammeter with selector switch, replacement of required part complete system checking and commencing by technician if necessary requirement all as specified and directed by Engineer-in-Charge. | 4 | Each | - | - |
| 8 | S&F in repairs of Over Current & Earth Fault relay complete accessories as per existing make and model all as specified and directed by Engr-in-charge. | 3 | Each | - | - |
| 9 | S&F in repairs digital voltmer 11 KV with selector switch, complete all as specified and as directed by Engr-in-charge. | 1 | Each | - | - |
| 10 | S&F in repairs digital ammeter 11 KV with selector switch, complete all as specified and as directed by Engr-in-charge. | 1 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_859449.xls
BOQ • 0.75 MB
Tender.pdf
Tender Documents • 2.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .