| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC NOT SPECIFIED | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹34.5 L+₹5.0 L (16.8%)Rejected-Finance 283 ALIEN MARKET SADAR KABARI BAZAR MEERUT CANTT UP | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹35.8 L+₹6.3 L (21.4%)Rejected-Finance C 92 JAIN NAGAR RAILWAY ROAD MEERUT UP | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹36 L+₹6.5 L (22.0%)Rejected-Finance PLOT NO 46 SECTOR PH I 03 GREATER NOIDA UP 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹36.8 L+₹7.3 L (24.6%)Rejected-Finance 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹49.4 L
EMD Value
₹98,880
Closing Date
13 Feb 2023, 6:00 pmClosed
GE (North)
GE (North) Meerut Cantt PIN 250001
SPECIAL REPAIR TO MANHOLES SEWAGE LINE DRAINS ETC AT SRC LINE MD ACCN AND PROVN OF HARD STANDING CHEQURED TILE AT P 94 DOGRA MANDIR ADDN ALTN OF TOILET CUM BATHROOM OF BLDG NO 94D UNDER AGE BR I AGE EM I OF GE NORTH MEERUT CANTT
2023_MES_575116_1
8385/E8
Open Tender
Civil Works
Item Rate
150 days
Meerut
Class D
Category a i
9 documents required · 9 mandatory
₹500
GE (North)
₹98,880
Yes
1 Mar 2023
14 Jan 2023
15 Feb 2023
14 Jan 2023
13 Feb 2023
30 Jan 2023
Amount
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m depth in soft/ loose soil for foundation etc or for shaft, wells, manholes,pier holes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out and levelling of bottom surface to required level complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soil complete all as specified and directed
Removal of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed
Demolition of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed
M&L Brick work with fly ash bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed.
All as per Srl item No 5.00 here-in-before but except bricks
Taking down cement plaster any description on brick or stone wall/ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L Rendering 15mm thick on brick surfaces in cement mortar 1:6 finished even and smooth without using extra cement including mixing intergral water proofing compound @ 3% of weight of cement or as mentioned in manufacturer's instructions complete all as specified and directed. Note : - Water proofing compound shall be measured and paid saperately "under supply only" item of this Schedule.
M&L Rendering 15mm thick on brick surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing intergral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and directed.
Supply only integral water proofing compound of approved manufacturer complete all as specified and directed.
Dismantling of cast iron ,PVC or reinforced concrete drain pipes, 75/110/150/200 mm dia, jointed in cement mortar and taking out of trenches, if required, Complete all as specified and directed.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
M&L Ultra P E,DWC (Double wall corrugated) pipe confirming IS-16098 Part-2 2013 pertaining structure wall plastics pinning system for sewage 200mm bore pipe SN4 and all necessary fittings and fixtures complete all as specified and directed.
M&L Ultra P E DWC (Double wall corrugated) pipe confirming IS-16098 Part-2 2013 pertaining structure wall plastics pinning system for sewage 150mm and above bore pipe SN4 and all necessary fittings and fixtures complete all as specified and directed
Demolition of cement concrete as in bed to drain pipe including packing under and haunching against the sides of pipe or as in manhole benching/bed etc complete all as specified and directed.
M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 200 mm bore pipes complete all as specified and directed.
M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150 mm bore pipes complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregates) in copings, kerbs, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
Demolition of reinforced cement concrete of any size member & of any description complete all as specified and directed.
M&L for providing precast RCC 1:2:4 type B-1 using 20mm graded stone aggrigate) as in cover slab chullah hoods, chajjas, water troughs, shelves or similar works set & jointed in CM 1:4 complete all as specified and directed.
S&F in repair Ready Made Precast reinforced cement concrete 1;2;4 type B1 using 20mm grade stone aggregate, factory made maanhole covers of size 450x900x50mm thick , set in cement mortor 1;6 all as specified and directed by Engineer-in-Charge.
M&L TMT steel bars 8mm or 10mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia all as specified. Complete all as specified and directed by Engineer-in-Charge.
M&L Form work to soffits of suspended slabs, floor slab etc n. exc. 200mm thickness flat for rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L Precast cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in manhole cover complete all as specified and as directed by Engineer-in-Charge.
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L for laying 75mm thick PCC 1:2:4 type B-O, (using 12.5mm graded crushed stone aggregates) as in floor to receive topping layer complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above gound level) complete all as specified and directed.
M& L for providing Cement concrete 1:4:8 Type D 2 (using 40 mm graded crushed stone aggregates) ,in foundations, filling and mass concrete complete all as specified and directed.
Cleaning of underground Horizontal sewage pipe of any dia upto 200mm (Cleaning length n.exc 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n.exc 300m and burrying in a pit and replacing manhole cover in position after cleaning complete all as specified and directed.
Dewatering of Septic tank and manhole of any depth in any position by pumping out and removing outside Military/Defence land by mechanical means (trolley mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after absorption of water and including providing and spreading required quantity of bleaching powder around the pit or dispose of waste material as per state protocol and washing the top of septic tank & soakage wells and surrounds with fresh water and sprinkling lime to make hygeinic complete all as specified and directed.
De-sludging of septic tank/Manhole of any capacity including connected intercepting chamber, manhole shaft, sludge chamber & filterbeds of any description and in anmy position by pumping out and removing of sludge outside Military/ Defence land by mechanical means (trolly mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spearding required qty of bleaching powder or dispose of waste material complete as per state protocol, including taking down of slab cover and placing the same in existing postion complete all as specified and directed by Engineer-in-Charge.
S & F stack clamp out of 50mm by 5mm flat iron & 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 110mm nominal bore pipe complete all as specified and directed.
S & F stack clamp out of 50mm by 5mm flat iron & 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 75 mm nominal bore pipe complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) bends of any radius, complete all as specified and directed
S&F in repairs 110mm bore PVC (SWR) bends of any radius, complete all as specified and directed
S&F in repairs PVC 110mm bore (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed
S&F in repairs CI Access door cover for 75mm bore pipe incl all asseseries complete all as specified and directed.
S&F in repairs CI Access door cover for 100mm bore pipe incl all asseseries complete all as specified and directed.
M&L for construction of septic tanks, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., for 100 users including necessary earth work in any type of soil (soft / loose / hard / dense) all as shown on drg No TD-217 sheet 1/7 to 7/7 complete all as specified and directed.
M&L for construction of Soakage well of size 1.20 m dia x 3.00m deep, excavated in ordinary soil, foundation in PCC 1:3:6, walls of honey combed and solid brick in cement mortar including RCC cover slab in M-25, filling work with brick bats complete all as specified and directed. Ref TD HQ CEBZ drg No TD/309 sheet No 1/4, 2/4, 3/4 & 4/4
M&L cement concrete 1:4:8, type D2(40mm graded stone aggregate) as in 75mm thick sub base.
M&L for chequered cement concrete colour tiles glossy finish size 300mm cmx300mmx25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the existing colour / shade of tile laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed
M&L laying for hardcore of broken brick of burnt clay bricks (well graded) bricks of gauge n exc 63 mm , deposited spreaded , levelled in layers n exc 15 cm thick watered and rammed to a true surface all as specified and directed.
Dismantling of floor, hearth or wall tiles / terrazzo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm in floors set and jointed in neat cement slurry and pointed with white or colour cemnt to match the color / shade of tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed
S&F Coloured Glazed colour ceramic tiles in vertical surfaces 450 x 350 x 7mm / 350 x 250 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the color / shade of tile laid over and including 10mm thick backing coat in cement mortar 1:4 complete, all as specified and directed
M&L Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar 1:3 complete all as specified and directed
M & L for applying 15 mm thick rendering using ready mix plaster bags in CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed Note : (i) Contractor is required to deposit ready mix bags for 100% CA quantity to the Engr-in-Charge within 15 days of issue of work order No 1 (ii) Water proofing compound shall be measured and paid saperately under "supply only" item of this Schedule.
Dismantling OH water tank of capacity exc 250 ltr but not exceeding 500 ltr and removing from site complete.
S&F triple layer white color 500 Ltrs Rotational moulded polyethylene (PVC) water storage tanks cylindrical vertical with closed top including nipple nuts and washers for fixing inlet, outlet/washout pipes and air vent pipes and incl dismantling water tanks any type & removing complete all as specified.
S&F in repairs 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule complete.
S&F in repairs 15mm dia bib cock long thread fancy type brass CP with wall flange fixed as in repair make-Jaquar Cat part No -039 complete all as specified and directed.
S&F in repairs angular valve, 15mm bore dia, cast copper alloy, CP fancy type with long shank and cup(concealed type) screwed down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed.
S&F in repair vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of lime concrete bedding and making connection with & tcincluding PVC P Trap, etc complete all as specified and directed.
S&F in repairs vitreous china WHB, white, flat back size 550x400mm including cutting for and pinning in ends of bracket or erecting stand with and including angle iron brackets, duly painted with two coats of synthetic enamel paint over one coat red oxide zinc chrome primer and providing cast copper alloy capastan head C.P brass pillar tap fency type 01 No 15mm bore, CP brass waste coupling 32mm dia, PVC waste pipe 32mm dia and PVC connection 450mm long high pressure with PTMT nut complete all as specified & directed.
S&F in repairs PVC low level flushing cistern of 10 Ltr capacity syphonic action type with inlet ball valve, float and handle including PVC brackets for mounting of cistern complete all as specified and directed.
S&F in repair PVC (SWR) floor trap, 75mm bore, plain with grating including jointing with solvent cement.
S&F in repair PVC (SWR) gully trap, 125/110mm bore, plain with grating including jointing with solvent cement.
S&F in repairs PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
Supplying and laying of CPVC 20mm outer dia pipes SDR 11 & Plain CPVC SDR 11, with all fittings and fixed on walls/ceiling or laying in floors complete all as specified
Taking down old existing water proofing treatment from the top of RCC/ arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises complete all as specified & directed.
Material & Labour for 50mm thick (average thickness) PCC 1:2:4 type B-O(using 12.5 mm graded stone aggregates) as in padding on roof finished even and fair without using extra cement all as specified and directed.
Material and Labour for 10mm thick cement paster in CM 1:4 mixed with WPC @ 3% by weight of cement or as per manufacturers instructoins finised even and smooth without using extra cement on roof surface when concreate is green and wall (WPC will be measured and paid seperately as supply only rate).
Material & labour for surface Preparation: The surface to receive the treatment shall be thoroughly free of laitance, scales, oil or any other loose material. It should be made free of any sharp objects. Cleaning of PCC shall be done with wire brushing to attain smooth levelled surface. Cracks shall be rectified, filled using dual shrinkage compensated Repair Mortar and dried for 72 hours before laying the liquid applied membrane. Grout: Providing Chemical injection treatment in the form of pressure grouting to the construction joint and cracked portion at 1m c/c by injecting cement slurry mixed with dual shrinkage compensated cementitious grout Injection grout additive, in the required consistency through the pre fixed PVC nozzles in the 18 mm dia holes, fixing of PVC nozzles with instant setting cement. Angle fillets/Coving: Providing and making of fillet, 50mm x 50mm on sharp corner of terrace with cement sand polymer mortar (add “multipurpose mortar”, 10% by weightofcement). First apply the bonding coat of Multi-Purpose Polymer 5-10% diluted in water and add to cement slurry. Apply the bonding slurry and apply the polymer mortar over the sharp edges.
Note: Grouting will be done when and where ever required. Treatment of pipe entry points: Preparing the inside surface of core and PVC /MS Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Note: Will be done when and where ever required Application of Asian Paints two component Epoxy Primer (Resin & Hardener) on the cleaned surface for bonding of Polyurethane with the existing concrete surface. 33 % water dilution is recommended with the pure mixed primer. The primer mixing ratio will be 1:3(Resin:Hardner) Supplying, providing and applying waterproofing treatment to Podium area with single component highly elastomeric seamless cold applied modified PU coating complete as per manufacturer’s specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have a dual combination of 280% elongation. Material coverage 1.2kg /sq.mt. (Note: Contractor is required to deposit 100% CA quantity to the Engr-in-Charge, within 15 days of acceptance of contract.
S&F in repairs vitreous china urinal bowl, flat back of size 465x355x265mm (minimum) white with grating and union for discharge pipe (excluding flushing cistern,flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusiveof fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) and including removal of debris & rubbish from the site complete all as specified and directed. Note : Stone slabs / tiles and hard core of any description shall not be measured & paid under this item.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed.
M&L for exterior grade, coloured, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. over the CM screed bed complete all as specifed and directed.
Taking down carefully any type of battens or conduit point wiring with conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and derected
M&L for point wiring with 1.5 Sqmm (nominal cross section area) single core, multi stranded PVC insulated, sheathed copper conductor, FRLS cable in and including in rigid pvc conduit 20 mm dia or higher medium grade ISI marked complete with all PVC Conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 1.5 Sqmm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic sheet screwed with brass screws, cup washers complete all as specified and directed for the following:- One light/Bulb/ street light pointcontrolled by one, one way switches 5/6 Amps.
All as per Srl item No 72.00 here-in-before but One 3 pin 5/6 Amps socket outet point on independent board, controlled by one, one way 5/6 Amps switch complete all as specified and derected
All as per Srl item No 72.00 here-in-before but One 3 pin 5/6 Amps socket outet point on same board, controlled by one, one way 5/6 Amps switch complete all as specified and derected
M&L for point wiring with 2.5 Sqmm (nominal cross section area) single core, multi stranded PVC insulated, sheathed copper conductor,FRLS, cable in and inrigid pvc conduit 20 mm dia or higher medium grade ISI marked complete with all PVC conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 2.5 Sqmm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :- (a) One 3 pin socket outlet, 15 amps, with cables 2.5 sqmm size on independent board, controlled by one, one way 15 amp switch.
S & F in repairs Switch piano flush button single pole one way 5 amp complete all as specified and directed.
S&F in repairs Socket outlet 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F in repairs Switch piano flush button single pole one way 15 amp complete all as specified and directed.
S&F in repairs Socket outlet 3 pin, 15 Amp, flush type complete all as specified and directed.
S&F in repairs ceiling rose, surface type, bakelite, 65 x 50 mm, three terminal complete all as specified and directed.
S&F in repairs LED lamp 9 W 6500k,240V complete all as specified and derected
S&F in repairs lamp holder insulated body with back plate fix done anodised 100 x 100 mm pressed steel box flush to the wall with 3 mm thick backlite cover complete all as specified and directed.
S&F in repairs LED tube light fitting T/5 surface mounting poly carbonate 240 volts 20 watts, 6500K complete all as specified & directed.
S&F in repairs Building security light fitting 1 x 35 LED type, drawn through and including GI bracket of size 25 mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed
S&F in repairs sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and derected
S&F in repairs MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified and derected
S&F in repairs Isolator DP 40 Amp ,240 Volts, suitable for fixing in MCB DB 'C' series in DB complete all as specified and derected
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wite 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specifiied or indicated including testing on completion complete all as specified and derected
S&F in repairs Exhaust fan made of sturdy engineering plastic, AC single phase, 230V of size 250 mm sweep complete with blades,frame and louvers including taking down of old unserviceable one and submit it to the AGE E/M Yard complete all as specified and derected
S&F in repairs Water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 25 ltr, BEE 5 stared complete with a rating including providing of hold fast in wall and PVC connection 45 cm long with 15 mm dia brass union at both end heavy duty complete all as specified and derected
vibha associates
Rajneesh Jain
Shri Kanchan Engineers
Arun Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .