Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I M I CA CWS I Unit II Overhauling of 1600 mm BFV including actuator GB overhauling checking and renewal of Nitrile rubber seal painting of Intake screen of Cooling water Pumps 2A 2B and 2C etc
2026_EB_710187_1
CE / MTPS-I / SE / M-I / CA /OT. 115/ 2026 -27
Open Tender
Power/Energy Projects/Products
Works
20 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹10,500
Yes
1 Oct 2026
1 Oct 2026
16 Oct 2026
1 Oct 2026
15 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Removal of RC valve in CWP 2A,2B & 2C of size 200 mm along with R.C. pipe and manhole door and fitting the same after completion of work. | 3 | Nos | - | - |
| 2 | Charges for checking and Renewal of Nitrile rubber Seal in 1600 mm Butterfly valve in Cooling Water pump 2A,2B & 2C, and if necessary renewal of seal clamping pad, rethreading of worn-out threads in the seal mounting disc and clamping the seal with the disc. Checking the open / close operation of 1600 mm butterfly valves of Cooling Water pump 2A,2B & 2C. | 3 | Nos | - | - |
| 3 | Overhauling of gear box assembly of 1600 mm B.F.V, including removal of Actuator, dismantling the gear box assembly, inspection, if necessary renewal of spare and reassembling the same in 2C pump. | 1 | No | - | - |
| 4 | Overhauling of B.F.V of size 1600 mm provided at CWP 2C pump discharge line including dismantling the bearing assembly at both ends inspection, if necessary renewal of spares and reassembling in 2C Butterfly valve size 1600mm. | 1 | No | - | - |
| 5 | Charges for lifting the screen, positioning, cleaning the debris and algae and placing the screens in its position after completion of painting works. (3 Sets - 1 Set consist of 3 nos.) | 3 | Sets | - | - |
| 6 | Charges for cleaning and painting with one coat of epoxy red oxide primer and one coat of epoxy coal thar black one over the other with proper interval over the intake screen frames structure of Cooling water pumps 2A,2B & 2C and cleaning & painting with one coat of epoxy red oxide primer and two coats of epoxy coal thar black one over the other with proper interval on the surface of new G.I flat used for fixing S.S. mesh in CWP intake screen. | 336 | M² | - | - |
| 7 | Charges for Overhauling of 600 mm size 150 Class Gate valves in clarifier inlet & outlet valves of CWS including dismantling the valve, cleaning all the parts checking the seating surface and lapping the gate/seat/flap and reassembling the valve with bonnet gasket and gland packing.(Gasket under contractor scope) | 3 | Nos | - | - |
| 8 | Drilling of M12/16mm dia hole in G.I flat of size 50x6mm for fixing S.S. mesh in each segment of intake screens of cooling water pump. | 2,376 | Nos | - | - |
| 9 | Charges for removing the existing damaged MS flat used for fixing S.S mesh in one row of segment in the intake screen by unscrewing the bolts and stiffeners by cutting and fixing the S.S mesh with new G.I flat by cutting to required length in each segment of intake screen and tightening with new S.S bolts and welding the stiffeners. Required cutting gas & welding electrodes are under contractor scope. | 27 | Nos | - | - |
| 10 | Cost of M 14 X 70 MM Length HT Bolt and nut with washer For Sl.No.2 | 10 | Kgs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_853322.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .