Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.0 L+₹2.5 L (13.0%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹22.5 L+₹3.1 L (16.0%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | Paragon Electrotechnics L3 | M/S JAINENDRA KUMAR JAIN L2 | M/s ASPIRE ENGINEERING ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dehydration and Filtration of transformer oil of distribution/power transformer of different capacities through stream line filter unit to increase di -electric strength (BDV) of transformer oil not less then 50 KV for 1 minute at 2.5 mm gap including topping up transformer oil to the required level as indicated to each transformer and testing transformer oil as per provisions of relevant IS codes before and after filtration. The quoted rate shall include for testing and submission of necessary test records in respect of transformer oil as decided by Eng in duplicate all as specified and directed.
Note: Transformer oil for topping up will be measured and paid separately | 8,480 | ltrs | 9 ₹76,320 Lowest | 11 ₹93,280 | 10 ₹84,800 |
| 2.00 | Material and labour for dismantling the 11 KV HT Supply and isolating the Distribution Transformer of capacity 100 to 200 KVA. Draining out the insulating oil from the tank. Opening the top cover, removing the damaged gasket and replacing with a like for like new gasket, placing the conservator tank oil indicator, inlet & outlet valve gasket in position and replacing the defective, burnt bushes with gaskets and brass studs, if required, dehydration and refilling drained transformer oil and ensuring no leakages of oil from any part of the transformers and then testing & energizing complete.
Note :-
(a) Fresh transformer oil for topping up and Dehydration and filtrations will be measured and paid separately.
(b) Bushes and brass studs will be measured and paid separately. | 2 | Each | 8,000 ₹16,000 | 2,000 ₹4,000 Lowest | 8,500 ₹17,000 |
| 3.00 | Material and labour for dismantling the 11 KV HT Supply and isolating the distribution transformer of capacity 315 to 500 KVA. Draining out the insulating oil from the tank, opening the top cover, removing the damaged gasket and and replacing with a like for like new gasket, placing the conservator tank oil indicator, inlet & outlet valve gasket in position and replacing the defective, burnt bushes with gaskets and brass studs, if required, doing dehydration and refilling drained transformer oil and ensuring no leakages of oil from any part of the transformers and then testing & energizing complete.
Note :-
(a) Fresh transformer oil for topping up and Dehydration and filtrations will be measured and paid separately.
(b) Bushes and brass studs will be measured and paid separately. | 2 | Each | 10,000 ₹20,000 | 5,000 ₹10,000 Lowest | 12,000 ₹24,000 |
| 4.00Material and Labour for replacing silica gel air breather container clear view type, first fill of good quality silica gel for transformers of following capacities. | ||||||
| 4.01 | (a) Transformers of capacity : 100 KVA to 200 KVA | 2 | Each | 1,200 ₹2,400 | 500 ₹1,000 Lowest | 800 ₹1,600 |
| 4.02 | (b) Transformers of capacity : 200 KVA to 500 KVA | 2 | Each | 1,500 ₹3,000 | 1,000 ₹2,000 Lowest | 1,200 ₹2,400 |
| 4.03 | (c) Transformers of capacity : 750 KVA | 1 | Each | 2,500 ₹2,500 | 2,500 ₹2,500 | 1,500 ₹1,500 Lowest |
| 4.04 | (d) Transformers of capacity : 1500 KVA | 1 | Each | 3,500 ₹3,500 | 3,000 ₹3,000 | 2,000 ₹2,000 Lowest |
| 5.00 | Disconnecting, dismantling & complete overhauling of Transformer of capacity 100 to 200 KVA after disconnecting of electric supply and earth connections including transportation to work shop, opening the top of transformer, draining out transformer oil, lifting/removing of top cover of transformer & cores with chain pulley blocks/crane, cleaning of sludge and washing down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers as required, refilling of Transformer oil after centrifuging at satisfactory dielectric strength complete after electric connections and testing all as specified and directed.
Notes applicable to BOQ Item No 05 to 08 :-
(a) Fresh transformer oil for topping up, dehydration and filtrations will be measured and paid separately.
(b) Bushes and brass studs will be measured and paid separately. | 1 | Each Job | 12,000 ₹12,000 | 7,500 ₹7,500 Lowest | 12,500 ₹12,500 |
| 6.00 | Disconnecting, dismantling & complete overhauling of Transformer of capacity 315 to 500 KVA after disconnecting of electric supply and earth connections including transportation to workshop, opening the top of transformer, draining out transformer oil, lifting/removing of top cover of transformer & cores with chain pulley blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers as required, re filling of Transformer oil after centrifuging at satisfactory dielectric strength complete after electric connections and testing all as specified and directed. | 1 | Each Job | 15,000 ₹15,000 | 9,500 ₹9,500 Lowest | 15,800 ₹15,800 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Jan 2026, 6:00 pmClosed
CWE AF NAGPUR
REPAIR/MAINTENANCE OF TRANSFORMER, VACCUM CIRCUIT BREAKERS AND OTHER MISCELLANEOUS HIGH TENSION MAINTENANCE WORKS AT VAYUSENA NAGAR NAGPUR
REPAIR/MAINTENANCE OF TRANSFORMER, VACCUM CIRCUIT BREAKERS AND OTHER MISCELLANEOUS HIGH TENSION MAINTENANCE WORKS AT VAYUSENA NAGAR NAGPUR
2026_MES_747130_1
80738/E8
Open Tender
Civil Works
Item Rate
GE AF NAGPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF NAGPUR
₹50,000
Yes
10 Mar 2026
3 Jan 2026
24 Jan 2026
3 Jan 2026
22 Jan 2026
17 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: HQ CWE (AF) NAGPUR
Name of Work: REPAIR/MAINTENANCE OF TRANSFORMER, VACCUM CIRCUIT BREAKERS AND OTHER MISCELLANEOUS HIGH TENSION MAINTENANCE WORKS AT VAYUSENA NAGAR, NAGPUR UNDER GE AF NAGPUR
Contract No: CWE (AF) /NGP/NAG/ OF 2025-26
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE inclusive of all taxes in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Quoted Amount in Words Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words
Material and Labour for replacing silica gel air breather container clear view type, first fill of good quality silica gel for transformers of following capacities.
Material and labour for removing and scraping super enameled paint from the old painted surfaces and applying two coats of synthetic enamel paint of colour smoke gray on the transformers of following capacity:-
(a) 100 KVA to 160 KVA Each Excess(+) Full Conversion INR
SUPPLY ONLY SPARES FOR SER ITEM NO 23 , 24 & 25
(a) Spring charging motor Make : CG/SIEMENS/ABB/AREVA/MEGAWIN Each Excess(+) Full Conversion INR
Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed. Cum Excess(+) Full Conversion INR
Supply and fix in replacement of heat shrinkable straight through cable jointing kit for 11 KV grade cable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed. Each Excess(+) Full Conversion INR
Note : The amount against Schedule of Credit on Page No. 38 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_836643.xls
BOQ • 0.40 MB
PS80738.pdf
Tender Documents • 1.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .