Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹8.0 L+₹64,800 (8.79%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹8.4 L+₹1.1 L (14.4%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
PROVISION OF APFC OF CAPACITY 225KVAR AT AF STATION AWANTIPUR
2021_MES_411184_1
GE (AF) AWA-27/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹29,800
Yes
31 Mar 2021
11 Jan 2021
3 Feb 2021
11 Jan 2021
1 Feb 2021
26 Jan 2021
60 days
Amount
Supply , fixing , connecting and commissioning with testing of Company Make (automatic and manual operation) power factor improvement panel of capacity 125 KVAR including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof, dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 Sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with Siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C‐1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , MAKE : SCHNEIDER/ SEIMENS / LEGRAND/ POWER CONTROL SYSTEM/ ELECTRICFIELD CO. as approved by GE, complete all as specified and directed by Engr‐in‐Charge and comprising of the following: ‐ Note:- LT cable required for connection from transformer to panel will be measured and paid seperately
INCOMING FEEDER:-
A. Incomer MCCB 250 Amp, Three Pole, Thermal based release with adjustable O/L, Adjustable S/C Setting Class II Front Face, 36KA rupturing capacity, lcs=100%lcu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier. Make: ‐ Schneider/ LEGRAND/ABB/ SEIMENS. ‐1 No
B. Metering Section‐ Digital Ammeter (0‐300) Amps, digital Volt Meter (0‐500) Volts, RYB Indicating Lamps ,1 Set Control fuses, CTs. 3
C. Insulated Busbar of COPPER of 250A Capacity for 3 phases, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc – 1 set.
D. Multi 12 Step 440V, 5A (144 x 144) microprocessor-based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
OUTGOING FEEDER:-
A. Accessories for 5 KVAR Capacitor Bank ‐ 02 Nos :‐ Capacitor Duty Contactor 5 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220 VAC ,MCB TP 16 A having breaking capacity 10 KA with HEAVY duty capacitor, on/off indicators , Start/stop Push button.
B. Accessories for 10 KVAR Capacitor Bank ‐ 03 Nos :‐ Capacitor Duty Contactor 10 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220 VAC ,MCB TP 25 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators . Start/stop Push button. Make: ‐ Schneider/ BCH/ABB/SEIMENS.
C. Accessories for 15 KVAR Capacitor Bank ‐ 3 Nos :‐ Capacitor Duty Contactor 15 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220VAC ,MCB TP 32 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators , Start/stop Push button. Make: ‐ Schneider/ BCH/ABB/SEIMENS.
D. Accessories for 20 KVAR Capacitor Bank ‐ 2 Nos :‐ Capacitor Duty Contactor 20 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil‐220VAC ,MCB TP 50 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators , Start/stop Push button. Make: ‐ Schneider/ BCH/ABB/SEIMENS.
E. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the panel 230vac 1500rpm. 160cu.m/h flying leads.
F. Automatic Power Factor controller steps Relay Microprocessor based for switching ON and OFF of capacitors to Display of voltage ,current, Active power .apparent Power display of COS 0 ,THD voltage ,THD current alarm indication for defective step, low power factor and access temperature. The relay having volt free c/o contact. Automatic detection and uses of optimum capacitor capable of 4 Quadrant operations and any phase offset requirement. Switching programme: LIFO combi Filter .manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 550 volt, 45 to 65 HZ. Current measuring 10MA‐5A suitable for CT x/1A and x/5A Commissiong without additional setting and programming. Three decimal power reading .Phasing out of fault capacitor bank Automatically .Make: Schneider/ BCH/ABB/SEIMENS.
G. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 14 SWG thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
Supply , fixing , connecting and commissioning with testing of Company Make (automatic and manual operation) power factor improvement panel of capacity 100 KVAR including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof, dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with Siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC (1:3:6) type C‐1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , MAKE : SCHNEIDER/ SEIMENS / LEGRAND/ POWER CONTROL SYSTEM/ ELECTRICFIELD CO. as approved by GE, complete all as specified and directed by Engr‐in‐Charge and comprising of the following: ‐ Note:- LT cable required for connection from transformer to panel will be measured and paid seperately
INCOMING FEEDER:-
A. Incomer MCCB 160 Amp , Three Pole, Termal based release with adjustable O/L ,Adjustable S/C Setting Class II Front Face, 36KA rupturing capacity, lcs=100%lcu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier. Make: ‐ Schneider/ABB/SEIMENS. ‐1 No
B .Metering Section‐ Digital Ammeter (0‐200) Amps, digital Volt Meter (0‐500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 Nos.
C. Insulated Busbar of Aluminium of 200A Capacity for 3 phases, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc – 1 set.
D. Multi 8 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
OUTGOING FEEDER:-
A. Accessories for 3 KVAR Capacitor Bank ‐ 1 Nos :‐ Capacitor Duty Contactor 3 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220VAC ,MCB TP 10 A having breaking capacity 10 KA with HEAVY duty capacitor, on/off indicators , Start/stop Push button. Make: ‐ Schneider/ABB/SEIMENS.
B. Accessories for 7 KVAR Capacitor Bank ‐ 1 Nos :‐ Capacitor Duty Contactor 7 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220VAC ,MCB TP 20 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators , Start/stop Push button. Make: ‐ Schneider/ABB/SEIMENS.
C. Accessories for 10 KVAR Capacitor Bank ‐ 2 Nos :‐ Capacitor Duty Contactor 10 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220VAC ,MCB TP 25 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators , Start/stop Push button. Make: ‐ Schneider/ABB/SEIMENS.
D. Accessories for 15 KVAR Capacitor Bank ‐ 2 Nos :‐ Capacitor Duty Contactor 15 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220VAC ,MCB TP 32 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators , Start/stop Push button. Make: ‐ Schneider/ABB/SEIMENS.
E. Accessories for 20 KVAR Capacitor Bank ‐ 2 Nos :‐ Capacitor Duty Contactor 20 KVAR with Damping Resistors which limits inrush current 440 volt, 3phase , 50 Hz , coil‐220VAC ,MCB TP 50 A having breaking capacity 10 KA with HEAVY duty capacitor on/off indicators , Start/stop Push button. Make: ‐ Schneider/ABB/SEIMENS.
F. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230VAC 1500rpm, 160cu.m/h flying leads
G. Automatic Power Factor controller steps Relay Microprocessor based for switching ON and OFF of capacitors to Display of voltage ,current, Active power .apparent Power display of COS 0 ,THD voltage ,THD current alarm indication for defective step, low power factor and access temperature. The relay having volt free c/o contact. Automatic detection and uses of optimum capacitor capable of 4 Quadrant operations and any phase offset requirement. Switching programme: LIFO combi Filter. manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 550 volt, 45 to 65 HZ. Current measuring 10MA‐5A suitable for CT x/1A and x/5A Commissiong without additional setting and programming. Three decimal power reading. Phasing out of fault capacitor bank Automatically. Make: ‐ Schneider/ABB/SEIMENS.
H. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 14 SWG thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer all as specified and directed.
S&F laying PVC unsheated 1100 volt copper conductor cable multi stranded of size 70 Sqmm single core conforming to IS: 694 all as specified and directed.
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 120Sqmm, 3.5 core including making electrical connections, complete all as specified and directed.
Light grade tubing 100 mm bore galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC (1:2:4) type B1 using 12.5 mm graded crushed stone aggregate, RCC cover, (1:2:4) type B1 using 12.5mm graded stone aggregate and xpm steel reinforcement with 10mm MS handle funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil all as specified.
M/S Sky Engineers
M/S Gh Qadir and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .