Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Successful Bidder | |
| 2 | L2₹12.4 L+₹1.7 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹13.5 L+₹2.8 L (26.5%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹16.4 L+₹5.7 L (53.8%)Rejected-Finance SAARTHAK 382 2 PLOT NO 36 2 OM NAGAR 1ST CROSS KHASBAG BELGAUM KARNATAKA 590 003 | BELAGAVI | KARNATAKA | 590003 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
17 Dec 2021, 6:00 pmClosed
GE AF SAMBRA
GE AF Sambra ATS Sambra Belgaum 591124
REPAIR TO REPLACEMENT TO L T PANEL PILLAR BOX L T OVERHEAD AND UNDER GROUND CABLE INCLUDING EARTHING AND OTHER CONNECTED SERVICES
2021_MES_482764_2
8671/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ATS SAMBRA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF sambra
₹20,000
Yes
22 Feb 2022
25 Nov 2021
20 Dec 2021
25 Nov 2021
17 Dec 2021
3 Dec 2021
Amount
M & L for disconnecting from the panel LT cables of the following sizes along with cable glands, cutting out the burnt/over heated cable ends, making new connections using new aluminium lugs of appropriate size including insulation tapes, excavation etc, and refixing the cable gland and making all connections & testing for proper working complete all as directed for following cables :-
120-240 sq mm 3.5 core
50-95 sqmm 3.5 core
M & L LT under ground cable XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 Volts grade in trenches / passing through pipes of following cross sectional area including taking out old existing unserviceable cables :-
3 1/2 core 120 sqmm
3 1/2 core 95 sqmm
3 1/2 core 70 sqmm
3 1/2 core 50 sqmm
3 1/2 core 35 sqmm
3 1/2 core 25 sqmm Note for Item No 2 :- Excavation and earth work, brick protection and sand cushioning will be measured and paid separately under relevant items of this schedule
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc and getting out in soft / loose soil complete all as specified and as directed.
All as per item No 3 here-in-before but exceeding 1.5 m deep and not exceeding 3.0 m deep.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all specified and as directed.
Removing excavated materials/soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all specified and as directed.
M&L for sand cushioning in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm all specified and as directed. Note:- For the purpose of payment, punned thickness only will be measured
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 45cm wide and 60cm in depth and getting out including filing back PCC 1:2:4 type B-2,finishing properly to level match with surroundings complete all as specified and as directed.
Supply and fix PVC spacers 4 way for LT over head line 1100 volts grade with necessary screws nuts bolts etc complete all as directed to prevent the lines touching each other on heavy wind as a preventive arrangement to the existing system including removing the existing old / out lived spacers complete all as specified and as directed.
Taking down unserviceable MCCB of any capacity after removing all the incoming and out going cable connections and offering necessary credit all as specified and as directed.
M & L MCCB 400Amps, 4 pole, 36KA with fixed thermal magnetic setting including connecting up with suitable aluminum cable lugs etc.complete all as specified and directed
M & L MCCB 250Amps, 4 pole, 36KA with fixed thermal magnetic setting including connecting up with suitable alumnium cable lugs etc.complete all as specified and directed
M & L MCCB 200Amps, 4 pole, 36KA with fixed thermal magnetic setting including connecting up with suitable alumnium cable lugs etc.complete all as specified and directed
M & LMCCB 100 Amps, 4 pole, 25 KA with fixed thermal magnetic setting with separate neutral link including connecting up with suitable alumnium cable lugs etc.complete all as specified and directed
M & L MCCB 63Amps, 4 pole, 25 KA with fixed thermal magnetic setting with separate neutral link including connecting up with suitable alumnium cable lugs etc.complete all as specified and directed
M & L MCCB 100 Ampos, 3 pole, 16 KA with fixed thermal magnetic setting with separate neutral link including connecting up with suitable alumnium cable lugs etc.complete all as specified and directed
M & L MCCB 63Amps, 3 pole, 16 KA with fixed thermal magnetic setting with separate neutral link including connecting up with suitable alumnium cable lugs etc.complete all as specified and directed Note for items 12 to 18 :- Quoted rate shall be deemed to be included the necessary minor modifications such as making additional holes / cutting slots etc in the existing panel if required for fixing the MCCBs.
Straining only existing loose conductors/ GI wire of any size complete all as directed by Engineer in charge (One span not more than 50 metre).
Cutting tree branches below, top and around the OH conductors not less than two metre around the line and keeping the line clearance throughout the contract period by trimming the branches repeatedly as many times as required, depending on the growth of new branches including clearing the site by depositing the branches to a distance not exceeding 50 m all as directed
M & L for stay assembly with complete accessories as shown in electrical plate No. 1 using 20 mm dia stay rod complete all as specified & directed (loop type insulator, stay clamps, excavation and concrete will be measured and paid separately)
M & L G I stay strand of size 7/4.00 mm complete all as specified & directed
M & L loop type insulator large size with over all dimensions 90x140mm, clearance of hole 25.5mm complete all as specified & directed
M & L Aluminum conductor steel reinforced ( ACSR ) drawn / fixed on poles including aluminum binding wire for jumpering including taking down old unserviceable conductor complete all as specified & directed
Supply and fixing L T pre stressed cement concrete poles 09 mtr long 102X172 mm at top and 102X279 mm at bottom class 10 erecting in vertical position including synthetic enamel painting upto 1.2 mtr height from top of coping with 03 Nos of each black and yellow alternate strip of 20 cm width, remaining with cement base paint & removing broken pole from site and complete all as specified & directed
M& L Plain cement concrete 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate as in foundation filling for poles complete all as specified & directed
M & L Plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in plat forms and coping around poles including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed.
M & L Plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as coping around poles etc complete including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed.
M & L G I pipes 50 mm dia bore light grade with fitting and fixed to poles/route/drains etc and ceillings or laid in floors all as specified and as directed.
All as per item No 29 herein before but 40 mm bore
All as per item No 29 herein before but 80 mm bore
M & L Pin type porcelin vitreous white, brown or green insulator including one galvanised steel spindle two galvanised washers and G I nut bolt 100 mm height for 1100 volts grade LT including taking down the old broken insulator all as specified & directed.
All as per item No 32 herein before but shackle type insulator for L T 1100 volts including taking down the old old broken insulator all as specified & directed.
M & L Straight through joint, heat shrinkable kit for cable of 185/120/95/70 sqmm 3.5 core suitable for aluminium conductor including earth work complete for LT cables
All as per item No 34 herein before but 50/35/25 sqmm 3.5 core
M & L mild steel cross arms, angles, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with two coats of Aluminium paint over a coat of Red oxide primer all as directed
M & L Painting of PCC/RCC poles 9 mtr height with two coats of synthetic enamel paint alternatively with black and yellow strip of width 150mm up to a height of 1.50mtr from ground level/above coping and applying one coat of cement wash for the remaining height including writing pole Nos etc complete all as specified & directed.
M & L cleaning and preparing the steel tubular poles 9 mtr height including cross arms & Painting with one coat of aluminium paint from bottom to top complete all as specified & directed.
Supply only Aluminium lugs suitable for UG cable of size 3 .5 / 4 core, 25 / 35 sqmm including respective size of lugs for the neutral cable all as specified & directed.
All as per Sl item No 39 here in before but for UG cable of size 3.5 core 50 / 70 sqmm.
All as per Sl item No 39 here in before but for UG cable of size 3.5 core 95 / 120 / 185 sqmm.
M & L throughly preparing the L T panel steel surfaces & spray painting using spray gun with two coats of synthetic enamel paint of smoke gray colour complete all as specified and as directed.
M&L for writing MES/SM Number on Transformer, VCB etc in Block letters of size 50 mm x 50mm and letter not more than 32 letters with synthetic enamle paint of colour white all as specified and directed.
M & L replacing broken hinges with 100mm M S medium weight hinges of LT Panel, DB etc by electric welding including denting and painting with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed
S & F Galvanised steel wire 4 mm dia all as specified and as directed
Supply, install, testing and commissioning of floor mounted LT feedar pillar box, CPRI approved, AC 415 Volts, 50 HZ, 3 Phase 4 wire of suitable size for accomodating the following accessories, totally enclosed self supporting structure / cubicle, fully compartmentalized type, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1 foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated, complete all as specified and directed :- (Main Panel) NOTE:- Connection from Main bus bar to Outgoing MCCB should be provided through bus bar of suitable rating instead of copper wires.
BUSBAR :- Electronic copper bus bar 350 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 Nos INCOMER : MCCB with Thermal and fixed magnetic release 4 pole 200 Amps, 50 KA -01 No
M & L Earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI strip 32x6mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to equipment and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 40 mm dia light grade GI for protection of earth strip, wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed.
M & L for HT/LT Cable route indicator with a welded/riveted disc of 100mm dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick grouted in PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed
M/s.GOODWILL ELECTRICALS
N K CONSTRUCTION
M/s NEELAM ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .