| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER. | |
| 2 | L2₹19.5 L+₹59,241.20 (3.13%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 3 | L3₹19.7 L+₹75,538.75 (3.99%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L3 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 4 | L4₹20.4 L+₹1.5 L (7.71%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 5 | L5₹21.3 L+₹2.3 L (12.2%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER. |
| Sl No | Description | Qty | Unit | PURVA ELECTRICALS AND ENGINEERS L2 | SKS Electricals L6 | Rama Electricals L7 | M/S kirpan Enterprises L3 | AMAN ENGINEERING AND ELECTIRICALS WORKS L5 | SGS ENERGY L8 | ONKAR ELECTRIC AND GENERAL STORE L4 | Aziz Traders L10 | PAUL REFRIGERATION L1 | ISHITARAJ ENTERPRISES L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install testing and commissioning in repair factory made out door type LT panel board of size not less than 1.5 mtr X 1.2mtr X 1 mtr, 440 volts , 3 phase , 4 wire system with powder coating provided to make it dust /vermin proo,f manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCA sheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing ACB's, MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 1000 Amps- 4Nos, including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resin insulator all housed in suitable bus bar chamber. All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs and provision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories complete all as specified and directed:-
Location :- Near Md Accn Sub Stn No- 2 &3 Aundh Camp. | 1 | Each Job | 3,52,000 ₹3,52,000 | 4,25,000 ₹4,25,000 | 4,52,000 ₹4,52,000 | 2,95,000 ₹2,95,000 | 2,80,000 ₹2,80,000 Lowest | 4,25,500 ₹4,25,500 | 3,00,000 ₹3,00,000 | 3,80,000 ₹3,80,000 | 3,70,000 ₹3,70,000 | 4,24,800 ₹4,24,800 |
| 1.01Note : (i) Electrical connection from switchgear to bus bar shall be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments shall be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 65mm x 65mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level. (vii) The operation of all MCCBs should be of Rotary handle type, the cost of rotory handles is deemed to be included in the quoted cost. | |||||||||||||
| 1.02Aluminium bus bar strips with proper colour code -04 No, 1000 A cap, insulator, nuts bolts etc complete. | |||||||||||||
| 1.03Indicator Lamp-01 Set (Set of three) | |||||||||||||
| 1.04Incommer ACB 630 Amps Manual draw out type , 50 KA 4 pole 415 volts - 01 Nos Make :- Legrand cat no -DMXS106N3MD4N or Havells Cat No- IHAFE21060080 | |||||||||||||
| 1.05Outgoing, MCCB 4P 320 amp with thermal magnetic release , 415V, 36 KA - 01 No (for APFC panel) Make Legrand cat no-4220 06 or Havells Cat No- IHLLSEE40320 | |||||||||||||
| 1.06Outgoing, MCCB 4P 125 amp with thermal magnetic release , 415V, 25 KA - 07 No (for Feeder panels of Md accn) Make Legrand cat no-4200 56 or Havells Cat No- IHTT1DBF0125 | |||||||||||||
| 1.07Outgoing, MCCB 4P 63 amp with thermal magnetic release , 415V, 25 KA - 01 No (for Street light panel) Make Legrand cat no-4200 53 or Havells Cat No- IHTTHDB40063 | |||||||||||||
| 1.08Digital Voltmeter 0 V to 500 V and Digital Amps meter 0 A to 1000 A. with selector switch | |||||||||||||
| 1.09Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. | |||||||||||||
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
17 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
MAINTENANCE AND REPAIRS OF LT UG CABLES LT BREAKERS AND FEEDER PANELS INCLUDING CONNECTED WORKS AT MD ACCN AREA OF AUNDH MILITARY STATION UNDER GE MH RH KHADKI
2025_MES_746232_1
8812/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹60,000
20 Feb 2026
26 Dec 2025
19 Jan 2026
26 Dec 2025
17 Jan 2026
10 Jan 2026
26 Dec 2025 - 17 Jan 2026
Note : (i) Electrical connection from switchgear to bus bar shall be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments shall be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 65mm x 65mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level. (vii) The operation of all MCCBs should be of Rotary handle type, the cost of rotory handles is deemed to be included in the quoted cost.
Aluminium bus bar strips with proper colour code -04 No, 1000 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer ACB 630 Amps Manual draw out type , 50 KA 4 pole 415 volts - 01 Nos Make :- Legrand cat no -DMXS106N3MD4N or Havells Cat No- IHAFE21060080
Outgoing, MCCB 4P 320 amp with thermal magnetic release , 415V, 36 KA - 01 No (for APFC panel) Make Legrand cat no-4220 06 or Havells Cat No- IHLLSEE40320
Outgoing, MCCB 4P 125 amp with thermal magnetic release , 415V, 25 KA - 07 No (for Feeder panels of Md accn) Make Legrand cat no-4200 56 or Havells Cat No- IHTT1DBF0125
Outgoing, MCCB 4P 63 amp with thermal magnetic release , 415V, 25 KA - 01 No (for Street light panel) Make Legrand cat no-4200 53 or Havells Cat No- IHTTHDB40063
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50mm x 50mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 500 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 250 amp with thermal magnetic release , 415V, 36 KA - 01 No (for Feeder panel) Make Legrand cat no-4220 49 or Havells cat no- IHLLSEE40250
Outgoing, MCCB 4P 125 amp with thermal magnetic release , 415V, 25 KA - 05 No (for Feeder panels of Md accn) Make Legrand cat no-4200 56 or Havells Cat No- IHTT1DBF0125
MCB TPN 32A,10KA C CURVE - 01 Nos for Street light Make Legrand
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Taking down unserviceable street light panel and Supply, install, commissioning and testing of street light panel outdoor type for load upto 6 kW, three phase 415 V/440 Volts of size not less then 0.6 mtr x 0.6 mtr x 0.3 mtr , confirming to IEC 61439 with IP-65 protection made out of 3.15 mm thick CRCA sheet with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door, doors of the panel should be removable type, 3 ph indicators lamp etc with provision for Incomer MCB TPN 40 Amps, contactor rating 32 Amps with Analog type street light timer, control wiring with suitable size of copper wire the panel shall be mounted on 50mm x 50mm x 6mm MS angle iron and 60 cm above the normal ground level & embedded 30 cm below ground level in PCC foundation (1:2:4) type B 1, (20 mm graded stone aggregate) connect new UG cable for Incoming from LT panel cable shall enter through cable glands for safety of cable where enter through panel complete all as specified and directed. Make of Street light Panel - Havells cat no- IHXTS03060 or equivalent in L&T/Schneider/BCH
Taking down unserviceable street light panel and Supply, install, commissioning and testing of street light panel outdoor type for load upto 12 kW, three phase 415 V/440 Volts of size not less then 0.6 mtr x 0.6 mtr x 0.3 mtr, confirming to IEC 61439 with IP-65 protection made out of 3.15 mm thick CRCA sheet with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door, doors of the panel should be removable type, 3 ph indicators lamp etc with provision for Incomer MCB TPN 63 Amps, contactor rating 63 Amps with Analog type street light timer, control wiring with suitable size of copper wire the panel shall be mounted on 50mm x 50mm x 6mm MS angle iron and 60 cm above the normal ground level & embedded 30 cm below ground level in PCC foundation (1:2:4) type B 1 (20 mm graded stone aggregate), connect new UG cable for Incoming from LT panel cable shall enter through cable glands for safety of cable where enter through panel complete all as specified and directed. Make of Street light Panel - Havells cat no- IHXTS09120 or equivalent in L&T/Schneider/BCH
Supply, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable in repair with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, PVC sleeve etc complete all as specified and directed for following sizes . Make :- Havells / Gloster / Finolex / Polycab
240 Sqmm 3.5 core
185 Sqmm 3.5 core
150 Sqmm 3.5 core
70 Sqmm 3.5 core
25 Sqmm 3.5 core
NOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule .
Supply and errect in vertical position Steel tubular swaged poles, type 410 SP- 31 (09 mtr long) in repair with 300mm x 300mm x 6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embeded portion and applying one coat fo red oxide primer, making 05 Nos strip each 30 cm high with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 mtr, painting with two coats of aluminium paint for the remaining height complete all as specified and directed. Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch.
Material and Labour in repair for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 mtr deep below ground level) with top edge of the earth plate not less than 1.5 mtr below ground level , connected to 32mm x 6mm GI strip as earthling lead by means of blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point complete all as specified and directed on testing on completion.
Material and Labour for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities not exc 15 cm deep (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete at an interval of every 30 days for the various sub stations complete all as specified and directed. Note: Spray of herbsite deemed included in quoted rate.
Material and Labour for hardcore of gauge n.exc 63 mm ,deposited, spread, and levelled in layers n.exc 15 cm thickness (below or above ground level) ,water and rammed to a true shape with broken stone or boulders complete all as specified and directed. ( Sub Station Yard)
Material and Labour for detection of street light LT UG cable fault with the help of cable fault detecting machine with experinced engineer and helper including necessary earth work complete & jointing the fautly cable with new joint , testing etc complete all as specified and directed. Note :- Cable joint kit will be measured and paid separately under relevent item of schedule .
Decarbonizing of LT indoor/outdoor Panel/feeder pillar box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter , replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB, incluidng dismantling the existing connected cables and re-connecting the same cablescomplete all as specified and directed. Note : (i)MCCBs,Bus bars,indicator lamps,Ammeter, Volt meter, will be measured & paid separately as supply only .
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed.
Ditto item no 13 but in hard/dense soil complete all as specified and directed.
Material and Labour for removing excavated material soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Material and Labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as specified and directed. Note - Punned thickness shall only be measured & paid .
Material and Labour for road cutting / foot path and making good with PCC 1:3:6 TYPE C-2 ( using 40 mm graded stone aggregate ) of 150 mm thick complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm for Under ground cable complete all as specified and directed.
Supply and laying GI tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable complete all as specified and directed.
Ditto item no -20 but 80 mm bore complete all as specified and directed.
Material and Labour for Plain cement concrete 1:3:6 (PCC) type C2 using 40mm graded stone aggregate for making foundation of Pole/stay assembly complete all as specified and directed
Material and Labour for Plain cement concrete 1:3:6 (PCC) type C1 using 20mm graded stone aggregate for making copings of Poles etc including dismantling the old coping from poles complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size 25 Sqmm to 50 Sqmm 3.5 core / 4 core cable complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 70 Sqmm to 120 Sqmm 3.5 core / 4 core cable complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 150 Sqmm to 185 Sqmm 3.5 core / 4 core cable complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 240 Sqmm to 300 Sqmm 3.5 core / 4 core cable complete all as specified and directed.
Supply and fixing MCCB, 4 pole, 36 KA breaking capacity, with Adjustable type, optimum 2.0, 315 amps, incl dismentling and taking down unsv one, making cutting of existing panel for fixing MCCB on suitable fitting , including fabrication work and make panel good and complete all as specified and directed. Make- Indoasian(optimum 2.0)/Legrand/L & T
Supply and fixing MCCB, 4 pole, 415 V, 16 KA breaking capacity, with Thermal magnetic release, optimum 1.1, 63 amps, incl dismentling taking down unsv one, making cutting of existing panel for fixing MCCB on suitable fitting and make panel good and complete all as specified and directed. Make- Indoasian/Legrand/L & T
Ditto as above item no -29 but of capacity 100 Amps complete all as specified and directed. Make- Indoasian/Legrand/L & T
Ditto as above item no- 29 but of capacity 125 Amps complete all as specified and directed. Make- Indoasian/Legrand/L & T
Ditto as above item no- 29 but of capacity 160 Amps complete all as specified and directed. Make- Indoasian/Legrand/L & T
Servicing of APFC panel cleaning, tightning of connections, setting programme, testing of CT'S including caliberation of APFC panel and replacing unserviceable capacitors, capacitor contactor, breakers, power factor controller after servicing testing panel and achive power factor of 1.00 complete all as specified and directed. Note: Capacitors, capacitor contactor, power factor controller measered and paid separately.
Note for item no 33 : (i) Quoted rate includes replacement of damaged panel locks as per existing as per site requirement. (ii) Painting of panels with mounting stand (with two coat of paint as specified by Engr in charge ) included in quoted rate . (iii) suitable size of lugs and cable gland for panel deemed to be included in quoted rate. (iv) Necessary MS sheet,Hinges and welding included in coated rate. (v) Rate includes cleaning of panel by using high speed air blower to remove dust.
Supply and fix in repair Power factor controllers (96x96), 5 steps, with timer, 415 volt, AC, 50 HZ power supply including suitable wiring complete all as specified and directed. Make: L &T Scheider/EPCOS
Supply and fix in repair Power factor controllers (144x144), 8 steps, with timer, 415 volt, AC, 50 HZ power supply including suitable wiring complete all as specified and directed. Make: L &T /Scheider/EPCOS
Supply in repair and , test, commissioning of LT capacitor upto 5 KVAR to 15 KVAR , 440Volt of Heavy duty for non-linear loads up to 440 V cylinderical type on existing APFC panel and necessary panel wiring , complete all as specified and directed. Make: For capacitor L & T /Legrand/Schneider
Ditto as above item no - 36 but rating of 20 KVAR to 25 KVAR, 440 volt complete all as specified and directed. Make: For capacitor L & T /Legrand/Schneider
Supply in repair and, test, commissioning of capacitor duty contactor of capacity of 15 KVAr on existing APFC panel and necessary panel wiring complete all as specified and directed. Make L & T/Legrand /Schneider
Ditto as above item no -38 but of 25 KVAR contactor complete all as specified and directed. Make L & T / Legrand /Schneider
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_835594.xls
BOQ • 0.27 MB
TENDER8812.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .