Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.1 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹60.3 L+₹2.2 L (3.83%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹61.3 L+₹3.2 L (5.58%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹62.7 L+₹4.6 L (7.92%)Admitted-Finance UDHAMPUR | L4 | Admitted-Finance | |
| 5 | L5₹71.9 L+₹13.9 L (23.9%)Admitted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | vijay builders L5 | JAI CHANDI MAA ENTERPRISES L3 | M/S SOFI SONS L1 | R S CONSTRUCTION L2 | M/S VAISHNO TRADERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Improvement of 11 KV Hospital feeder by way of insertion of poles/Replacement of undersize and damged poles and Replacement of old conductor with ACSR Rabbit for providing smooth power supply to Govt. Degree College Boys Udhampur. | ||||||||
| 1.01 | 11 mtr. Long ST Pole (ST-410 SP-56) | 24 | No. | 48,000 ₹6,72,000 | 88,800 ₹5,68,800 | 96,000 ₹5,28,000 Lowest | 48,000 ₹6,72,000 | 72,000 ₹6,24,000 |
| 1.02 | GI V Cross -arm with top Bracket including clamps | 200 | Kg | 6,000 ₹32,000 | 2,000 ₹25,000 | 4,000 ₹33,000 | 2,000 ₹24,000 Lowest | 2,000 ₹24,000 Lowest |
| 1.03 | GI Channel X-arm including clamps and Angle for braces | 1,100 | Kg | 33,000 ₹1,76,000 | 11,000 ₹1,37,500 | 22,000 ₹1,61,700 | 11,000 ₹1,32,000 Lowest | 11,000 ₹1,32,000 Lowest |
| 1.04 | 50mm² ACSR Rabbit conductor | 6.5 | Km | 45,500 ₹4,22,500 | 22,750 ₹3,47,750 | 32,500 ₹4,22,500 | 6,500 ₹3,18,500 Lowest | 19,500 ₹3,25,000 |
| 1.05 | PG Clamps | 12 | No. | 600 ₹1,800 | 120 ₹1,080 | 120 ₹2,520 | 120 ₹240 Lowest | 120 ₹720 |
| 1.06 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. | 70 | No. | 3,500 ₹21,000 | 700 ₹13,650 Lowest | 700 ₹14,000 | 700 ₹14,000 | 700 ₹14,000 |
| 1.07 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting | 60 | No. | 6,000 ₹27,000 | 600 ₹17,700 | 3,000 ₹28,980 | 600 ₹16,800 | 600 ₹12,000 Lowest |
| 1.08 | Galvanized Nuts and Bolts | 24 | Kg | 1,200 ₹4,800 | 240 ₹3,000 | 48 ₹3,408 | 240 ₹3,360 | 240 ₹2,880 Lowest |
| 1.09 | Danger Plates with Clamps | 10 | No. | 500 ₹1,500 | 100 ₹1,000 | 20 ₹1,020 | 250 ₹750 Lowest | 200 ₹1,000 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
31 Jan 2024, 3:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Improvement of Infrastructure at Govt. Degree College Boys Udhampur under the jurisdiction of Electric Division JPDCL, Udhampur on turnkey basis.
2024_PDD_242535_1
ED/Udh/134 of 2023-24 dt. 09-01-2024
Open Tender
Electrical Works
Turn-key
120 days
In Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Executive Engineer Electric Division JPDCL
₹1.5 L
26 Feb 2024
10 Jan 2024
1 Feb 2024
10 Jan 2024
31 Jan 2024
10 Jan 2024
10 Jan 2024 - 20 Jan 2024
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Improvement of 11 KV Hospital feeder by way of insertion of poles/Replacement of undersize and damged poles and Replacement of old conductor with ACSR Rabbit for providing smooth power supply to Govt. Degree College Boys Udhampur.
11 mtr. Long ST Pole (ST-410 SP-56)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
50mm² ACSR Rabbit conductor
PG Clamps
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 11 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
11 KV Isolator 630 Amp Double Break 3-Ø
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 250 KVA sub stn. at Govt. Degree College Boys Udhampur.
11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 Copper Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT Distribution box for 250 KVA DTR with MCCB for incormer and SFU's for outgoing circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase HT Trivector meter with CT PT Unit including meter box
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. long with 2 coat of Al. paint
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of LT network alongwith provision of LED Lights at Govt. Degree College Boys Udhampur.
8 mtr. Long ST poles (ST-410 SP15)
LED Street Light 100 Watt alongwith included existing network connected items with Light like bracket with clamp 2.5mm² Copper cable, IPC etc.
50mm² AB Cable (3x50+1x16+1x35)
120mm² AB Cable (3x120+1x16+1x70)
100 Amp MCB with outdoor box
40 Amp MCB with outdoor box
Painting of 8 mtr ST poles with two coat of Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
Distribution box with 4 MCB 32 Amp
35mm² Single Core PVC Cable
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Augmentation of distribution sub station from 100 KVA to 250 KVA at Govt. Degree College Boys Udhampur.
9 mtr. Long ST poles (ST-410 SP33)
11/0.433 KV, 3-phase 250 KVA distribution Transformer with Bimetallic Terminal Connectors Energy Level-2 Copper Wound & with LV Cable box having detachable Aluminium Gland plate
300mm² single phase cable 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
G.I Channel/Angle/Flat of sizes including clamps
LT Distribution box for 250 KVA DTR with MCCB for incomer & switch Fuse units for outgoing circuits.
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Galvanized Nuts and Bolts
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transformer body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
3 Phase trivector meter with HT/PT unit including meter box
Dismantling of old weasel conductor & Write back to Divisional Store of ED Udhampur
Dismantling of Rails 8/9 mtr. & Write back to Divisional Store of ED Udhampur
Dismantling of C.I Cross arm & Write back to Divisional Store of ED Udhampur
Dismantling of 100 KV Old transformer with allied material channel iron, G.O, DO, etc & Write back to Divisional Store of ED Udhampur
Dismantling & reerection of ST/PCC poles 8 mtr/ 9mtr long
R S CONSTRUCTION
JAI CHANDI MAA ENTERPRISES
M/S VAISHNO TRADERS
vijay builders
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .