GE (N) BIKANER
GE (N) BIKANER Rajasthan
REPAIR/MAINT OF SUMMER APPLIANCES ,DEEP FREEZER, WATER COOLER , AC ,DG SET AND OTHER CONNECTED ITEMS AT MFFR UNDER GE (N) BIKANER
2023_MES_605326_2
GE (N) BKN-TOKEN/37/2023-24
Open Tender
Miscellaneous Works
Item Rate
335 days
MFFR Mahajan
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (N) BIKANER
₹80,000
Yes
16 Jan 2024
5 Aug 2023
1 Sept 2023
5 Aug 2023
24 Aug 2023
12 Aug 2023
Amount
Desert Cooler Repair to Desert Cooler Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint complete all as specified
All as per item No. 1 here in before but applying one coats of synthetic enamel paint to external surfaces of desert coolers including steel grills, removing of wooden grass pad & refixing the same after necessary work side panel etc complete all asp specified.
Taking down carefully old unserviceable water pumps heavy duty of capacity 1/70 HP, 230 volts 50 HZ single in lieu providing new submersible type water pump including necessary wire connection etc. Make;- Bajaj/CG/ Havells
Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, including replacement of mounting legs & nuts bolts with capacitor 4 Mfd as reqd at site complete all as specified and directed. Make;- Bajaj/CG/ Havells
Taking down carefully fan motor 1/5 to 1/6 HP 230 volts, 50 HZ, from existing desert coolers of each camp at MFFR and refixing the same camp fan motor after rewinding with super enameled copper wire of existing size complete including replacement of bush/bearing, mounting legs & nuts bolts capacitor 4 Mfd as reqd at site complete all as specified and directed. Make: Milan/chetak Note:- Contractor will be arranged all required T&P (winding machine) repair for desert cooler motor/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
Taking down the following parts from the existing desert coolers & providing new parts in same possition as listed below- (a) Capacitor for desert cooler 4 MFD 230 volts Make: Asian/Tibcon
(b) GI sheet as per existing guage front grill including nuts bolts and washers suitable for 18/20" sweep desert coolers including necessary wire connection, regulator & on/off switch etc reqd at site, Make-Alka/kinark.
Taking down following old part of desert cooler old rusted as under and M & L out of 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required accessories for fixing etc complete ( Bottom tank as existing size)
Top cover as existing size
Side panels size- set of three
Wood wool pad for desert coolers (set of three)
Supporting jali for desert coolers (set of three)
Plug Top 3 pin, 5-A, 230 Volt
Plug Top 3 pin, 15-A, 230 Volt
Fan blades made of aluminium for desert cooler as per sample any size.
Cable, 3 core, copper conductor size 23/0.0076 for desert cooler. Make: plaza/finolex/kalinga
Replacement of PVC pipe 15mm for desert cooler including all necessary 'T' joints & clamps reqd at site
Distributor of PVC for desert cooler with fixing bolt
Replacement of Elbow of PVC for desert cooler
S&F in repair tap mounting with nipple 1/2" as per sample.
S&F in repair water outlet nipple with washers and check nuts (copper/brass)
DEEP FREEZER Taking down unserviceable compressor from deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing deep freezers of capacity 320 ltr, Make: voltas/Usha/Sidhwal/Blue star complete all as directed.
Supply and fixing compressor suitable for deep freezer 320 ltr make- Blue star/Gulmarg/Usha, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and as directed.
Supply and fixing compressor suitable for deep freezer 405 ltr make- Blue star, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips.complete all as specified and as directed.
Cleaning of complete deep freezer existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing deep freezer of 320 /405 ltrs capacity of make and model as per existing complete all as specified and as directed.
Water Cooler Taking down unserviceable compressor form deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing water coolers of Make: voltas/Usha/Sidhwal/Blue star 60/120,150/180.
Supply and fixing new hermetically sealed unit (compressor) of following Makes and model including provision of new bushes,grommets, sleeves , washers, mounting rubers nuts boltes,terminals,covers,brasing and clips in the existing Water coolers 60/120 Ltrs Make :- Blue star /usha /voltas with necessary accessaries and all as directed.
Ditto all as per item No. 27 here in before but for 150/180ltrs capacity complete all as specied and as directed by engr -in-charge.
Taking down carefully existing internal wiring of existing water coolers and in liu provision of new internal wiring of with PVC insulated copper conducter cable of size 40/ 0.0076 sq mm including replacementof main lead 03 meter long, terminals clips, thimbles, 03 pin plug top 15 amps & soldering extra compelte all as specified. Make :- of wiring plaza/finolex
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing water cooler complete all as specified and directed.
Removing of old rusted warn out portion of sheet/angle/flat iron from base, front and top etc. of the water cooler/ air conditioner and providing new mild steel sheet, angle iron/MS flat including necessary bending, welding. reveting etc. including making provision for mounting of fan motors, compressor, and condenser complete all as specified.
Complete removing old faded paint from steel surfaces of water cooler by scrapers making the surface smooth including filing material and painting the surface of any description over 10 Cm in width of girth not otherwise described with one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed.
Taking down deffective fan motor from water coolers, dismentling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size. Make : Milan/Chetak including replacement of shaft, boshes, mounting rubbers, nuts, bolts and refixing after reassembling and testing in existing water cooler for under mentioned fan motors :- (Note : The unit rate coated shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers, insulating materials and clams) Fan motors of capacity 1/16 HP 230 Volts single phase.
Fan motors of capacity 1/32 HP 230 Volts single phase.
Fan motors of capacity 1/35 HP 230 Volts single phase.
fan blade made out of aluminium as per sample
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/16 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/10 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/25 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and directed.
S & F push cock (stainlees steel) for water cooler as per sample existing.
S & F thermostat for water cooler as per sample existing.
S & F relay with OLP suitable for water cooler existing as per sample.
S & F runing capacitor 36 MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 60/80 MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 80/100 MFD. Make : Tibcon/Sharda/ Epcos
S & F runing capacitor 100/120 MFD. Make : Tibcon/Sharda/ Epcos
S & F runing capacitor 10MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 15MFD. Make : Tibcon/Sharda/Epcos
S & F runing capacitor 40/60 MFD. Make : Tibcon/Sharda/Epcos
Cable, 3 core, copper conductor size 40/0.0076 for water cooler. Make: plaza /finolex/kalinga
Air Conditioner Taking down unserviceable compresor 2TR capacity from the window/split AC of any make and supply and fixing new compresor 2 Ton capacity of including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips from existing AC complete all as specified and as directed.
Ditto all as per srl Item No. 52 here-in before but for window type AC 1.5 TR capacity of any make as per existing.
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing window/split type air conditioner of 1.5/2 TR capacities of make and model as per existing complete all as specified and directed.
Taking down unserviceable fan motor of any capacity from the window type air conditioner 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing guage and size including heat varnishes replacement of shaft, bearing and bush complete all as found unserviceable after opening complete all as specified and required and as directed.
Removing of existing window/split type AC 1.5/2 Ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and refixing on mounting including provn for making opening air tight and dust proof including testing and commissioning complete all as directed.
S & F running capacitor 45 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 60 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 50 MFD Make : Tibcon/Sharda/Epcos
S & F PCB (Printed Circuit Board) of window/split type capacity 1.5/2 Ton all as specified and as directed.
Replacement of remote control of 1.5/2 Ton window/split type AC of any make/type all as specified and as directed.
Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing and complete overhoauling of AC 1.5/2 ton capacity all as specified: - Note- Accessories/parts paid saperately under relevent items
PVC filters for AC (window/split)
Contactor for split AC
Starting relay for AC
Replacement of burnt out transformer and S&F new transformer of 3 or 4 KVA voltage stabilizer of any make.:'V' guard
Taking down unserviceable indoor unit of split AC capacity 1.5 TR from existing place and supply and fix new indoor unit of split AC 1.5 TR capacity of including mounting frame with nuts, bolts in existing place complete all as specified and as directed. Make :- Samsung
Taking downunserviceable Exhaust rooler of split AC capacity 2.0 TR from existing place and supply and fix new Exhaust rooler of split AC 1.5 TR capacity of including bush/bearing as per existing type complete accessories fix in existing place complete all as specified and as directed. Make :- Samsung
Taking downunserviceable out door unit of split AC capacity 1.5 TR from existing place and supply and fix new indoor unit of split AC 1.5 TR capacity of including mounting frame with nuts, bolts and complete accessories fix in existing place complete all as specified and as directed. Make :- Samsung
Supply and laying PVC insulated stranded aluminium conductor cable heavy duty 1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 06 Sqmm 2 core nominal cross section incl remove unserviceable cable complete all as specified. Make - (Asian Cable Co./Finolex/Polycab)
Ceiling Fan Taking down ceiling fan for repair/servicing i.e. greasing/oiling etc., 1200/1400 mm sweep, of any make and any type model, ceiing cable end with tape, dismandling the blades, removing fan and deposit the blades/motor to store for repairing/servicing complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be taking down ceiling fan of each camp in MFFR and carrying with saftey deposit for repair/sevicing i.e winding/greasing /oiling in AGE MFFR yard and camp wise marked each fan by permnent marker and informed to JE E/M )
M&L re-winding of ceiling fan of size 1200/1400 mm sweep with super enameled copper winding wire of gauge as per existing size/No of wire conforming to IS, including varnishing the motor windings with best quality varnish, capacitor 2.5 Mfd and fixing the same place complete all as specified and as directed by Engineer-in-charge. (Note:- Contractor will be arranged all required T&P repair for ceiling fan/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
S&F in replacement of ball bearing of size/No. 6201 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6202 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6203 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of brass bush suitable for ceiling fan of any make and model conforming to IS complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Shaft suitable for ceiling fan as per existing size and shape complete all as specified and as directed by Engineer-in-charge
S&F fabricated down rod made out of 15mm dia MS pipe medium duty 60cm long including nut, bolt, & washer etc and including drilling holes on top and bottom fan fixing with fan hooks and ceiling respectively as required suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F D clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F PVC canopies (set of two) as required at site and as directed by Engineer in charge.
S&F condenser 2.5 MFD conforming to IS complete all as specified and as directed by Engineer-in-charge.
S & F of flexible wire of size 23/.0076 stranded copper conductor complete all as specified and directed by Engr -in-charge.
S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement including taking down old regulator complete all as specified and as directed by Engineer-in-charge.
Taking down and dismantling of exhaust fan 250 mm/350 mm/450 mm sweep of any make and model, opening the cover, separating the rotor and startor assembly, locating the fault and maing the fan in fully serviceable condition including replacing the defected worn out screw, flexible wire size 23/0.0076, oiling/greasing the fan and re-assembling the samd and testing complete to the entire satisfaction of Engineer-in-charge.
Re-winding of exhaust fan 250 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish, capacitor and fixing the same place complete all as specified and as directed by Engineer-in-charge. Note:- Contractor will be arranged all required T&P repair for exhaust fan/sevicing i.e winding/greasing /oiling in AGE MFFR yard)
Ditto all as per item No. 85 here in above but of size 350 mm sweep complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 85 here in above but of size 450 mm sweep complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of blades suitable size for exhaust fan 250 mm duly approved by Engineer in charge complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 88 here in above but size of exhaust fan 350 mm sweep complete all as specified and as directed by Engineer-in-charge.
Ditto all as per item No. 88 here in above but size of exhaust fan 450 mm sweep complete all as specified and as directed by Engineer-in-charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 300 mm complete all as specified and directed by Engr-in- charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 450 mm complete all as specified and directed by Engr-in- charge.
Supply and fixing in replacement of PVC fresh air fan (Exhaust fan) of size 250/300 mm sweep and connecting up including three core PVC insulated multi stranded copper conductor cable of size 1.5 Sqmm wire from ceiling rose/connector to fan of length not less than 1.0 meter complete all as specified and directed. Make: - Usha/Bajaj/Havells
Cleaning and preparation of old surface of ceiling and exhaust fan complete of any size and spray coat painting with synthetic enameled paint complete all as specified and as directed by Enge-in-charge.
M&L for dismantling unservicable ESU ( Engine safety Unit) of 25 KVA DG Set to 63.5 KVA, to replacement of new ESU ( Engine safety Unit) complete all as specified and directed.
M&L for complete servicing of 25 KVADG set of any make and type to made functional replacing unserviceable spare parts, old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant etc. complete all as specified and directed. (Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 25 KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete. Note :- all other minor works all as specified and directed by engr -in-charge.
M&L for complete servicing of 45 KVADG set of any make and type to made functional replacing unserviceable spare parts, old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant etc. complete all as specified and directed. (Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 45KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete.
M&L for complete servicing of 63 KVADG set of any make and type to made functional replacing old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant etc. complete all as specified and directed. (Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 63KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete.
Supply only following spare parts suitable for engine of 25 KVA DG to 63.5 KVA DG set of any make and type. (a) Main Bearing
(b) Con Rod bearing
(c) Bearing t/w Kir
(d) pIston ASSEMBLY
(e) Cylender liner
(f) Valve pair inlet & Exhuast
(g) Valve guide
(h) wire snap ring
(j) wire stem seal
(k) Set of joints
(l) Intermediate ring 1.3 mm
(m) Shim Ring cylender
(n) Set of rings
(o) Oil Seal Big size as per requirement
(p) Oil Seal small size as per requirement
(q) Bearing C /Bush Kir
(r) Bearing IG Bush
(s) KOEL CARE super geniune oil 13 Ltr CAN
(t) Fuel filter element pre
(u) Fuel filter element micro
(v) Lube oil filter element
(W) Lube oil pump Assy
(X) Sealing ring
(Y) Hose for air cleaner 70 IDX 80L.
(z) Set of high pressure pipe.
Supply only element fuel filter both primary and secondary suitable for 25 KVA DG set complete all as specified and directed.
Supply only oil filter suitable for 25 KVA DG set complete all as specified and directed.
Supply only element air cleaner inner and outer suitable for 25 KVA DG set complete all as specified and directed.
M&L for dismantling unservicable AVR and supply & fixing new AVR, suitable for 25KVA DG set, Make:Kiloskar/Stamford, commissioning & testing on full load complete all as specified and directed .
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 25 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and directed .
Supply only element fuel filter both primary and secondary suitable for 45 KVA DG set complete all as specified and directed.
Supply only oil filter suitable for 45 KVA DG set complete all as specified and directed.
Supply only element air cleaner inner and outer suitable for 45 KVA DG set complete all as specified and directed. Make:- Mico/Cummins
M&L for dismantling unservicable AVR and supply & fixing new AVR, suitable for 45 KVA DG set, commissioning & testing on full load complete all as specified and directed .
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 45 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and directed .
Supply only element fuel filter both primary and secondary suitable for 63.5KVA DG set complete all as specified and directed.
Supply only oil filter suitable for 62.5/63 KVA DG set complete all as specified and directed.
Supply only element air cleaner inner and outer suitable for 63.5 KVA DG set complete all as specified and directed.
M&L for dismantling unservicable AVR and supply & fixing new AVR, suitable for 62.5/63 KVA DG set, , commissioning & testing on full load complete all as specified and directed .
M&L dismantling unservicable. self starter 12 Volt DC with solonied switch suitable for 62.5/63 KVA DG set, transporting to civil workshop, complete repairing by replacing unserviceable parts, inatallation, commissioning & testing on full load complete all as specified and directed .
M&L dismantling unservicable. self starter 12 Volt DC of 45 KVA to 63 KVA DG set, and supply & fixing new self starter 12 Volt DC suitable for 45KVA to 63 KVA DG set, inatallation, commissioning & testing on full load complete all as specified and directed .
Supply & replacement of DC battery 12 volts, 150AH complete all as specified and directed. Make:-EXIDE/POWER TECH
Supply & replacement of DC battery 12 volts, 180AH complete all as specified and directed. Make:-EXIDE/POWER TECH
M&L for dismantling unservicable. battery charging alternator 12V, DC suitable for 25 to 62.5 KVA DG sets, trasporting to civil workshop, complete repairing/ overhauling by replacing unsv parts, inatallation, commissioning & testing on full load complete all as specified and directed.
Supply and topping up coolent in radiater of DG sets complete all as specified and directed. Make : Castrol or equivalent as approved by GE.
S&F MCCB 125 Amp 25 KA 4 pole 415 Volts complete all as specified and directed. Make:- Legrand/Shalabh/Havelles.
M&L for painting of DG Set on one coat of synthetic enameled paint of DG set of any make and type installed at varries sites 25 KVA to 62.5 KVA capacity complete with alternator as well as electric panel board by means of spray including preparation of surfaces before painting complete in all respect all as directed.
Taking out old unserviceble cable of any size complete all as specified and directed.
Supply and laying in Trenches/floor/walls/roof cable XLPE insulated PVC un sheathed steel tape/ wire armoured multistranded aluminium conductor cable 1100 volts heavy duty of size 25 sqmm 3.5 core with jointing material like cable lugs ,gland and connecting up complete all as specified and directed.
Supply and laying in Trenches/floor/walls/roof cable XLPE insulated PVC un sheathed steel tape/ wire armoured multistranded aluminium conductor cable 1100 volts heavy duty of size 35 sqmm 3.5 core with jointing material like cable lugs ,gland and connecting up complete all as specified and directed.
Dismantling of existing defective Rotor of the 45 kva DG set disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on DG set complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing defective Stator of the 45 kva DG set disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on DG set complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing defective Excitor of the cap 45 kva to 63.5 KVA DG set disconnecting the electric connecting and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on DG set complete all as specified and as directed by Engineer-in-Charge.
Dismantling of panel wiring of DG set of capaity 25 to 62.5 KVA DG set, and rewiring with suitable size copper wire complete all as specified and as directed by Engineer-in-Charge.
M&L for Chane of silicon diode of suitable cap for DG set of cap 25 KVA to 62.5 KVA , commissioning & testing on full load complete all as specified and directed .
S&F in replacement of four pole offload changeover switch 100 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
S&F in replacement of four pole onload/offload changeover switch 200 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/Havells/C&S
M & L for Shifting to DG set of any Cap and any Size From office complex to E/M installation & back to office after complition of requirement ( approx 90Km to 120 Km) and commissioning ,testing after refixing the same with connecting acessories as required at site as specified and as directed by Enge -in-charge . Note-transporation deemed to included in quoted rate.
M&L for Earthing to equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed.
M&L for complete servicing of 5/7.5 KVADG set of any make and type to made functional replacing unserviceable spare parts, old oil filer, fuel filter , air cleaner filter element including drain out old engine oil (lubricants) and coolant including commissioning & testing on full load upto satisfaction after repair/ replacement at unserviceable parts/filter engine oil/ coolant etc. complete all as specified and directed.(Note:- Replaced Spare parts/ engine oil/ coolant shall be measured & paid under appropriate items of Sch 'A')
M&L for dismantling of engine of 5/7.5 KVA DG set of any make & type by strip opening and repairing of diesel engine gen set with following repairs/ replacement of worn out spare parts commissioning testing on full load and entire satisfication of Engineer-in-charge after complete repairing (Testing shall be carried out for 08 hrs continious and diesel for testing shall be supplied by the deptt free for testing). (Note:- Spare parts shall be measured & paid as supply only under appropriate items of Sch 'A') (a) Valve set cutting and fixing of valve guide. (b) Fixing of cylinder linner. (c) Cylinder block liner bearing and threading of existing bores. (d) Fixing of piston ring complete. (e) Repair to cylinder block injector sleeves including fixing and testing complete.
M&L for dismantling unservicable Start Key & Push Battan of 25 KVA DG Set to 63.5 KVA, to replacement of new Start Key complete all as specified and directed.
M/s Rohit Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .