Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC 104 INDIRA MARKET NEAR MALAI MANDIR SECTOR 07 RK PURAM NEW DELHI PIN 110022 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110022 | ₹2.1 Cr Quoted ₹2.2 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.9 Cr+₹68.3 L (31.2%)Rejected-Finance OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹2.9 Cr+₹68.3 L (31.2%) | L2 | Rejected-Finance Not being lowest |
Tender Value
₹1.9 Cr
EMD Value
₹3.5 L
Closing Date
2 Sept 2023, 6:00 pmClosed
CE RND Delhi
HQ CE RND Timarpur, Delhi-110054
DEMOLITION OF OLD WORKSHOP BUILDING (BUILDING NO P-3 AND P-4) AND CONSTRUCTION OF NEW G Plus 1 WORKSHOP BUILDING UNDER SPECIAL WORK AT SSPL UNDER GE(I) RND DELHI
2023_MES_605717_1
CE RND/DLI-17/DLI/2023-24
Open Tender
Civil Works
Lump-sum
450 days
Delhi
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE I RND DELHI
₹3.5 L
Yes
26 Sept 2023
26 Jun 2023
9 Sept 2023
26 Jun 2023
2 Sept 2023
14 Aug 2023
Amount
SCHEDULE `A' SECTION- I BUILDING WORKS as under is prepriced by MES
Construction of G+1 New Workshop Bldg including complete all as specified and shown on drawings
NOTE : Schedule 'A' Section- II to Section- XI are under Ser no. 2.01 to 2.10 are prepriced by MES
Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-II
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- III
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section-IV
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- V
Lump sum price worked out by the Contractor for "EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Section- VI
Lump sum price worked out by the Contractor for "AREA DRAINAGE” as listed in Schedule ‘A’ Section- VII
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Section- VIII
Lump sum price worked out by the Contractor for "ROAD / PATH/ CULVERT” as listed in Schedule ‘A’ Section- IX
Lump sum price worked out by the Contractor for "REF & AC WORK” as listed in Schedule ‘A’ Section- X
Lump sum price worked out by the Contractor for "DEMOLITION WORK” as listed in Schedule ‘A’ Section- XI
SCHEDULE `A' SECTION - XII MISC ITEMS as under is not prepriced by MES.
(Bldg work) Supply & Fixing of foundation bolt 1"dia 9" long with bed blocks & non shrink grout at ground floor for erection/Installation of various machines
(INTERNAL ELECTRIFICATION) S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 32 Amps MCB.
Supply and fixing of VTPN DB 12 ways vertical type suitable for MCCB incomer upto 200 Amps single door complete all as specified and directed by Engr-in-Charge.
Supply and fixing of VTPN DB 08 ways vertical type suitable for MCCB incomer upto 200 Amps single door complete all as specified and directed by Engr-in-Charge.
Supply and fixing of VTPN DB 04 ways vertical type suitable for MCCB incomer upto 200 Amps single door complete all as specified and directed by Engr-in-Charge.
Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA
EXTERNAL WATER SUPPLY M&L for valve camber of size 900x900x900mm (internal dimation ) with sub class 'B'brick masonery built in cm 1:6. 15cm thick internal & 20mm thick external plaster in 1:4 cm provided with 3.15mm thick ms sheet cover welded 50x50x6mm ms angle iron frame fixed in coping pcc 1:2:4 type B1 ( using 20mm graded stone aggregate ) with locking arrangement and handel ,painting with two coat of red oxide and two coats of synthetic enameled red paint over one coat of red oxide primer complete inculiding excavation and earth work all as specified and directed.
EXTERNAL ELECTRIFICATION M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique and necessary machine including HDPE pipe of 150mmdia suitable for 0.4 mpa working pressure
S&F LT panel complete outdoor type cubical panel board suitable for 3 phase, 4 wired, 433V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 433 volts factory fabricated in an approved factory with CRCA sheet not less than 3.1 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Aluminium bus -bar three phase 4 wired system having current carrying capacity not less than 1.2 times of the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls alongwith suitable sizes of glands duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (The Panel should be mounted on angle iron of size 40 x 40 x 6 mm grounting in PCC platform, rates deemed to be included in the quoted rate ), CPRI approved manufacturer (Make:- Universal Switchgears & Controls/Conelec Systems/Tricolite/Mc Layer/Indo Asian/SMS Panel) and to accommodate the following incoming and outgoing controls and suitable size:-
INCOMING (i) MCCB 800 A 50 KA 4 pole -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUT GOING (i) MCCB 200 A,36 KA, 4 pole -03 Nos. (ii) MCCB 125 A,36 KA, 4 pole -02 Nos.
S&F LT panel complete outdoor type cubical panel board suitable for 3 phase, 4 wired, 433V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 433 volts factory fabricated in an approved factory with CRCA sheet not less than 2 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Aluminium bus -bar three phase 4 wired system having current carrying capacity not less than 1.2 times of the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls alongwith suitable sizes of glands duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (The Panel should be mounted on angle iron of size 40 x 40 x 6 mm grounting in PCC platform, rates deemed to be included in the quoted rate ), CPRI approved manufacturer (Make:- Universal Switchgears & Controls/Conelec Systems/Tricolite/Mc Layer/Indo Asian/SMS Panel) and to accommodate the following incoming and outgoing controls and suitable size:-
INCOMING (i) MCCB 200A 35 KA 4 pole -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUT GOING (i) MCCB 125 A,36 KA, 4 pole -02 Nos.
Ref & AC Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour (or nearest size) (Steel body).
Supply and fix floor mounted AC stand suitable for out door AC unit up to cap of 1.5 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc complete all as specified and as directed by Engr-in-charge.
Demolition work Dismantling Aluminium Partition of any size including infills like glass etc complete all as specified and directed
G and G Infratech Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .