Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹43.0 L+₹40,609.43 (0.95%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹43.4 L+₹81,021.52 (1.90%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹43.8 L+₹1.2 L (2.91%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹44.2 L+₹1.7 L (3.91%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹38.4 L
EMD Value
₹78,000
Closing Date
27 Jan 2023, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
SPECIAL REPAIR TO BLDG NO P-137 (OTM ACCN) AT KALIMPONG UNDER GE 876 EWS
2022_MES_571561_1
CWE/136-WE/53 OF 2022-23
Open Tender
Civil Works
Item Rate
240 days
Kalimpong
Class D, Category a(I)
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹78,000
Yes
24 Feb 2023
27 Dec 2022
28 Jan 2023
27 Dec 2022
27 Jan 2023
22 Jan 2023
27 Dec 2022 - 3 Jan 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8mm thick premium quality to relevant IS (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement motar (1:6), complete all as specified and directed.
M&L for 350x 250x 7 mm/ 450X 350X 7mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick rendering in cement mortar (1:4), complete all as specified and directed.
M&L for machine cut Kota stone slab flooring, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in CM 1:6 finished even and rough all as specified and directed.
M&L for machine cut Kota stone slab as in vertical surfaces such as dado/skirting, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 10 mm thick rendering in CM 1:4 finished even and rough all as specified and directed.
M&L for 50 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C-1, (using 20mm graded stone aggregate) as in surface channels and drains including necessary form work complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitered / stopped ends etc all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not specifically provided for complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) (nominal mix), type A1 (using 20mm graded crushed stone aggregate) as in Chajjas and the like complete all as specified and directed.
Use & Waste of timber formwork to chajjas, chullah hoods, troughs and similar items including edges rough finished surfaces complete all as specified and directed.
S&F of TMT bars 10 mm dia and over, cut to length, bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia, cut to length, bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 25mm thick plain cement concrete(1:2:4), type B-1, (using 20mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc, all as specified and as directed.
M/L for 10mm thick rendering in cement mortar 1:3 on other than fair faces of brick or concrete surfaces of internal walls in sunken slab finished even and fair with WPC.(WPC measured separately).
M&L for first layer of slurry of cement at the rate of 0.488Kg/Sqm mixed with acrylic based polymer modified cementitous composite compound at the rate of 0.253kg/Sqm this layer will be allowed to air cure for 4 hours,second layer of slurry of cement at the rate 0.242 kg/Sqm mixed with acrylic based polymer modified cementitous composite compound at the rate of 0.126 kg/Sqm.this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours including 200 micron thick polythene film pasted with the help of adhesives shall be provided over above treatment.NOTE:The rate includes preparation of surface,treatment and sealing of all joints,corners,junctions of pipes and masonary within polymer mixed slurry.This treatment shall be provided after provision of pipes and masonary within polymer mixed slurry.This treatment shall be provided after provision of cement plaster mixed with WPC and synthetic fibers while concrete is still green complete all as specified and directed. Make: STP / Dr Fixit sunken treatment / Pidilite.
M&L for plain cement concrete (1:5:10), type E-2 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area), complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application incl prepration of concrete surafce and applying two coats of aluminium paint, complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound @ 3% by weight of cement in second layer or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and fair (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
Supply only integral water proofing compond all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of alkali resistant priming paint including 3 mm thick layer of wall care putty, complete all as specified and directed.
M&L scrapping of existing treatment and applying one coat 3mm thick of wall care putty and then applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of alkali resistant priming paint after preparation of wall surfaces complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls, complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of white wash as in walls, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash as in ceiling, complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash as in ceiling, complete all as specified and directed.
M&L for two coats of exterior emulsion paint (Apex) over one coat of priming coat of alkali-resistant paint including preparation on new plastered wall surfaces, complete all as specified and directed.
Scrubing down of existing treatment on wall surfaces and applying two coat of exterior emulsion paint(Apex) over one coat of priming coat of alkali-resistant paint on old plastered wall surfaces, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed.
Dismentling of fillets rails etc under 40 sqcm in section (framed work), complete all as specified and directed.
S&F of Gl frame work (Size of grid 605 x 605mm) for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.55 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
S&F of PVC false ceiling with light weight PVC hollow section panel made of 1mm thick and over all thickness of panel 7 mm thick and 200mm wide strip of colour teak/ wood grain / melamine finish, fixed in new false ceiling grid made of Aluminum / GI /MS / Wooden, complete all as specified and as directed. Note: New false ceiling grid made of Aluminium/ GI/ MS/ Wooden, if provided shall be measured and paid separately.
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A), complete all as specified and directed.
Demolition of brick work or stone/boulder masonary, built in lime mortar including all quions, arches, pillars etc, but excluding ashler facings, dressed stone work and precast concrete articles, all as specified and directed.
M&L for brick work with sub class 'B' bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down shutters of any description exc 2 sq. m each and refixing in same opening after Resecuring or easing & adjusting, complete all as specified and directed.
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, all as specified and directed.
S&F pressed steel frame of size 125 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock ,strike plate, etc complete all as specified and directed.
S&F of pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock ,strike plate, etc complete all as specified and directed.
S&F of 35 mm thick (batten thickness) second class hard wood, plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F of 35 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F of solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing and as directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed.
S&F of steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F of steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed.
S&F steel window or ventilator fixed type with glazing bar complete complete all as specified and directed.
S&F of small fittings such as brackets of any type latch and hinge block, shaped door window stops and the like in second class hard wood article not exc 200 cucm each complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in bond stone, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
S&F of mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F of 100 mm size butt hinges, medium weight, cold rolled mild steel and fixed, all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed, all as specified and directed.
S&F of 150 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple(bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F in repairs decorative type drapery curtain rod (curtain rails), of 25 mm dia powder coated with fixing brackets, stops, rollers etc complete all as specified and directed.
S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F of 4.0mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane, complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed.
S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests and 'P' or 'S' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding, connection to trap and flushing pipe etc and making good to disturbed surfaces of floor to match with wxisting surface, complete all as specified and directed.
S&F in repairs vitreous china wash basin white of any pattern, flat back of size 550mmx400mm (excluding taps), waste, chain and plug including waste pipe ,suitable size of brackets and making good the damaged walls as per existing wall finish, complete all as specified and directed.
S&F of 15mm bore dia pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F of 40mm bore dia of discharge pipe, waste coupling of PTMT (half or full threaded), (Minimum weight 60 gms), all as specified and directed.
S&F in repair brass chromium plated shower rose with or without swivel joints 125 mm size , including fixing to steel pipe or union, complete all as specified and directed.
S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, complete all as specified and directed.
S&F in repair 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
Taking up or down 15 mm bore old steel tubing and connections, including cleaning for refixing or removal to store or removal unserviceable pipe from site, complete all as specified and directed.
S&F of 15 mm bore tubes 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on stone walls, complete all as specified and directed.
S&F in repair 15mm bore dia bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
M&L for 110 mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
S&F of salt-glazed stoneware gully trap size 150 x 150 mm square or round mounted type ‘S’, setting and jointed with solvent cement, complete all as specified and directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
S&F in repairs vitreous China bowl type (back or corner wall type), urinal flat back, size of 465 x 355 x 265 mm white (minimum), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including waste pipe and urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms). (Exclusive of fixing supply pipe to flushing cistern and trap)
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 100/110 mm bore including accessories set in cement mortar and removing rubbish from site, complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius, complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door including jointing with solvent cement, complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door including jointing with solvent cement, complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) vent cowl including jointing with solvent cement, complete all as specified and directed.
S&F of 180 mm bore PVC (SWR) half round eaves gutter drain pipe, complete all as specified and directed.
S&F of PVC (SWR) stop end outlet with one clamp for 180mm dia half round valley gutter pipes, complete all as specified and directed.
S&F of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers, ladder and similar small articles conforming to Fe-290 Gde-E-165, all as specified and directed.
M&L for coloured & polished chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments includig 20mm thick screed bed in cement mortar (1:6), complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Dismantling and taking down unserviceable main switches, DB's including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes, complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on the same board with other switches, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 15 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Supplied & fixed for 20ampSingle pole, 20amp, 240 Volt, enclosure with a two pin and earth plug and socket complete with one single pole MCB, all as specified and directed.
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
M&L for switch piano, flush type single pole, one way 5 Amp, 240 Volts, all as specified and directed.
M&L for switch socket combination 2 in 1, 3 pin, 5 Amps flush type universal, all as specified and directed.
M&L for switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal, all as specified and directed.
S&F in replacement of lamp angle/batten holder Bakelite Pin/Retrofit type, in and including with 10 watt LED Lamp (B22), all as specified and directed.
S&F of LED light fitting 1x9 Watt / 1X10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed.
Supply and fixing of LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F of Powerline Vertical TPN DB with suitable for 160A MCCB incomer, double door (IP-54), 4 Ways, built- in 250 Amps copper busbar for each phase, 2 neutral and 2 earth bar complete suitable for 415 Volts, AC, 50 Hz complete all as specified and directed.
Supply and fixing of MCCB, tripple pole & neutral (4 Pole), 125 Amps, 415 volts, 50 Hz, 16kA, complete all as specified and directed
Supply and fixing of sheet metal enclosure, double door for MCB DB's, 8 way with 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all all as specified and directed.
Supply and fixing of sheet metal enclosure, double door for MCB DB's, 4 way single pole & neutral (SPN) and current carrying capacity of 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, complete all all as specified and directed.
Supply and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity of 40 AMP in the MCB DB Complete with connection testing and commissioning, complete all all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 40 to 63 AMP in the MCB DB complete with connection testing and commissioning, complete all all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, complete all all as specified and directed.
S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLS) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing and capping of required size (not less than 32mm) conforming to IS 2079-1973 with accessories for sub main connection including 6.0 Sqmm PVC (FRLS) insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 6.0 sqmm PVC FRLS copper conductor shall be measured as one unit length).
S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLS) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing and capping of required size (not less than 25mm) conforming to IS 2079-1973 with accessories for sub main connection including 4.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 4.0 sqmm PVC FRLS copper conductor shall be measured as one unit length).
Supply and fixing of exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, complete all all as specified and directed.
M&L for making hole in the existing wall / building without distrubing to existing infrastructure for fixing of exhaust fan complete including making good to match with the existing specification, complete all as specified and directed.
Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC chamber with PCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core, cross-sectional area 25 sq.mm, complete all as specified and directed.
Excavation in trenches/ foundation in soft / loose soil not exceeding 1.50m wide and not exceeding 1.50m deep for laying of LT under ground cable/ pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
M&L for sand cushioning to under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :-Puned layers of 18 cm thick sand shall measured only.
Supply and laying of old size sub-class ’B’ bricks (designation 75), laid flat equal to width of bricks, perpendicular to under groung cables over the dry sand cushioning, for cable protection, complete all as specified and directed.
M&L for 40mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable/ earth strip, all as specified and directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
PRASAD PRADHAN AND SON
MS BRAHMA CONSTRUCTION
DEEP CHANDRA JOSHI
RAJU TAMANG
G K SUTHAR
HEM RAJ GURUNG
SUNIL PRADHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .