Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.2 L+₹4.3 L (17.7%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹32.4 L+₹8.4 L (35.0%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹34.1 L+₹10.1 L (42.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹35.7 L+₹11.7 L (48.8%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jun 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744 103
REPAIR AND RENEWAL OF INTERNAL ELECTRICAL SUPPLY AND CONNECTED ELECTRICAL FITTINGS FIXTURES AT MD ACCN OF MINNIE BAY UNDER AGE EM-I AT GE MINNIE BAY PORT BLAIR
2023_MES_598809_1
8259/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹60,000
Yes
27 Jun 2023
26 May 2023
19 Jun 2023
27 May 2023
16 Jun 2023
10 Jun 2023
Amount
M&L for taking down carefully existing aluminium point wiring (light, fan, socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good to disturbed surfaces of walls, floors etc complete all as specified and as directed by Engr-in-Charge.
M&L for taking down existing old DBs and making good disturbed surfaces of walls to match the existing surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match with the existing surfaces all as specified and as directed by Engr-in-Charge
M&L for point wiring with two run of single core PVC insulated unsheathed 1100 volts grade multistranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) drawn through & including rigid non metallic PVC conduit medium grade of size not less than 20mm dia for concealed wiring with PVC conduit accessories or PVC casing capping of suitable size but not less than 20 mm in width for surface wiring with PVC casing capping fitting accessories including PVC terminal box & 3mm laminated sheet and continuous earth wire of PVC insulated unsheathed 1100 volts grade multi stranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) connecting to common earth dolly using color code system complete all as specified and as directed.
One light point controlled by one switch complete all as specified and as directed by Engr-in-Charge.
One 3 pin socket outlet, 5 Amps, on the same board complete all as specified and as directed by Engr-in-Charge.
One 3 pin socket outlet 5 Amps, independent board complete all as specified and as directed by Engr-in-Charge.
One light point controlled by two way switches complete all as specified and as directed by Engr-in-Charge.
One bell/ buzzer point controlled by one push button complete all as specified and as directed by Engr-in-Charge.
All as per item No 04 above but cable of size 2.5 sqmm size for socket outlet 15 Amps on independent board complete all as specified and as directed by Engr-in-Charge.
S&F for submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 6 Sqmm nominal area (FRLS) drawn through in and including rigid non metallic PVC conduit medium grade of size not less than 25mm dia with conduit accessories or PVC casing capping of size not less than 25mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 6 Sqmm PVC insulated copper conductor(FRLS) for earth continuity wire complete all as specified and as directed by Engr-in-Charge. Note : three runs of cable and one run of PVC conduit/PVC casing capping shall be measured as one unit
S&F for submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 4 Sqmm nominal area (FRLS) drawn through in and including rigid non metallic PVC conduit medium grade of size not less than 25mm dia with conduit accessories or PVC casing capping of size not less than 25mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 4 Sqmm PVC insulated copper conductor(FRLS) for earth continuity wire complete all as specified and as directed by Engr-in-Charge. Note : three runs of cable and one run of PVC conduit/PVC casing capping shall be measured as one unit
S&F for submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 2.5 Sqmm nominal area (FRLSH) drawn through in and including rigid non metallic PVC conduit medium grade of size not less than 20mm dia with conduit accessories or PVC casing capping of size not less than 20mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 2.5 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed. Note : 3 runs of cable and one run of PVC conduit/PVC casing capping shall be measured as one unit run in this quoted item.
S&F for submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 1.5 Sqmm nominal area (FRLSH) drawn through in and including rigid non metallic PVC conduit medium grade of size not less than 20mm dia with conduit accessories or PVC casing capping of size not less than 20mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 1.5 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed. Note : three runs of cable and one run of PVC conduit/PVC casing capping shall be measured as one unit run in this quoted item.
S&F switch piano, flush type, single pole, one way 5 Amp complete all as specified and as directed by Engr-in-Charge
S&F bell push, flush type 5 amps complete all as specified and directed by Engr-in-Charge .
S&F switch piano, flush type, single pole, two way 6 Amp complete all as specified and as directed by Engr-in-Charge
S&F switch socket combination, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed by Engr-in-Charge.
S&F switch socket combinatioin 5/6 Amp flush type complete all as specified and as directed by Engr-in-Charge
S&F ceiling rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engr-in-Charge.
S&F as in repair switch piano, flush type, single pole, one way 5 Amp complete all as specified and as directed by Engr-in-Charge
S&F in repair switch piano, flush type, single pole, one way 15 Amp complete all as specified and as directed by Engr-in-Charge
S&F in repair bell push, flush type 5 amps complete all as specified and directed by Engr-in-Charge .
S&F in repair switch piano, flush type, single pole, two way 6 Amp complete all as specified and as directed by Engr-in-Charge
S&F in repair switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed by Engr-in-Charge.
S&F in repair switch socket combination 2 in 1, 6 Amp flush type complete all as specified and as directed by Engr-in-Charge
S&F in repair ceiling rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engr-in-Charge.
S&F in repair PVC box suitable for switch socket combination 6 and 16 Amp complete all as specified and as directed by Engr-in-Charge.
S&F in repair LED tube lights fitting 20W, 4 feet , 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr-in-Charge
S&F in replacement of LED tube light fitting, 1x18 w, 230v, surface and wall mounted LED batten, 2100lumen PC Body tube housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified directed.
S&F in repair LED mirror light fitting 10W, 2 feet, 220V AC with high out put diffuser decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge.
S&F in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engr-in-Charge.
S&F in repair calling bell , Ding Dong type, 230 Volts AC complete all as specified and as directed by Engr-in-Charge
S&F in repair Foco bulbo LED 9W, B22 complete all as specified and as directed by Engr-in-Charge
S&F in repair Foco bulbo LED 7W, B22 complete all as specified and as directed by Engr-in-Charge
S&F in repair round shape LED fittings, 6W, 230 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
S&F in repair round shape LED fittings, 12W, 230 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
S&F in repair LED light fittigs 15W, round, surface downlight for ceiling including fittings and necessary connections complete all as specified and as directed by Engr-in-Charge.
S&F in repair LED wall light 5W, indoor chaira wood type including fittings and necessary connections complete all as specified and as directed bt Engr-in-Charge.
S&F in repair LED building security lights 48 watt, IP 65, AC 230 Volts, including light sensor and necessary fixing arragements complete all as specified and as directed by Engr-in-Charge.
S&F in repair modular switch one way, 6 Amps, 1 module complete all as specified and as directed by Engr-in-Charge
S&F in repair modular switch one way, 16 Amps, 1 module complete all as specified and as directed by Engr-in-Charge .
S&F in repair modular bell push, 6 Amps, 1 module complete all as specified and as directed by Engr-in-Charge .
S&F in repair modular socket, 2/3 pin, 6 amps, 2 module complete all as specified and as directed.
S&F in repair modular socket, 2/3 pin, 6/16 amps, 2 module complete all as specified and as directed by Engr-in-Charge .
S&F in repair modular metal flush box 3 module complete all as specified and as directed by Engr-in-Charge .
S&F in repair modular metal flush box 6 module complete all as specified and as directed by Engr-in-Charge .
S&F in repair modular white cover plate with frame 3 module complete all as specified and as directed by Engr-in-Charge.
S&F in repair modular white cover plate with frame 6 module complete all as specified and as directed by Engr-in-Charge.
S&F in repair of MCCB DB VTPN 4 way,IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door with MCCB incomer and MCB outgoing and fixing of cable with suitable size of lugs including repair of disturbed surface to match with the existing complete all as specified and as directed by Engr-in-Charge.
S&F in repair MCB DB TPN 4 way, double door, sheet metal enclosure, 415V, 100 amps rated busbar including fixing of cable with appropriate size of lugs including repair of disturbed surface to match with the existing complete all as specified and as directed by Engr-in-Charge.
S&F in repair MCB DB SPN 8 way, double door, sheet metal enclosure, 240V, 100 amps rated busbar including fixing of cable with appropriate size of lugs including repair of disturbed surface to match with the existing complete all as specified and as directed by Engr-in-Charge.
S&F in repair Power unit modules 25A, 240V, 50HZ consists of 2 module surface mounting plastic box - 2 No, 2 module cover plate & frame - 2 No, 25Amps Motor Starter - 1 No , 25Amps socket - 01 No and 25 Amps Plug Top - 1 No complete all as specified and as directed by Engr-in-Charge.
Sopply only MCCB 4 Pole, 415V, adjustable type, 100 to 125 Amps with breaking capacity 16kA complete all as specified and as directed by Engr-in-Charge.
Supply only MCB TPN 40 to 63 Amp, C series, 415V, 10 KA complete all as specified and as directed by Engr-in-Charge.
S&F in repair MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volt, 50 HZ complete all as specified and as directed by Engr-in-Charge.
S&F in repair MCB SP 6-32 Amps ,10 KA, B Curve, 230 Volts ,50 HZ complete all as specified and as directed by Engr-in-Charge..
S&F in repair Rigid non-metallic PVC conduit ISI marked of size 20mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed by Engr-in-Charge.
S&F in repair flexible conduit of size 20mm dia, white colour including fixing accessories complete all as specified and as directed by Engr-in-Charge.
S&F in repair 3mm thick laminated hylem sheet, white colour including re-fixing of serviceable switch, sockets and regulator etc., complete all as specified and as directed by Engr-in-Charge.
S&F socket outlet 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed by Engr-in-Charge.
S&F socket outlet 2 in 1, 6 Amp flush type complete all as specified and as directed by Engr-in-Charge.
M&L for earthing complete with Galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32 x 6mm dia connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth lead and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5m length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required , as specified and as directed by Engineer in charge as per SSR Part-I of 2010.
M/s Power Engineering Co
SKY GROUP
DHAKSHNA MOORTHY AND SON
MGP Enterprises
Ravi Enterprises
ISLAND SALES ENTERPRISES
Chandra Construction Enterprises
SMS Engineering Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .