Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.7 LAccepted-AOC NOT AVAILABLE | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC Responsive Bidder |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
6 Sept 2021, 3:00 pmClosed
Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Prov. and laying of pipelines, installation of House connections and minor repairs in village Killi Chehlan, Block Moga-I, Distt. Moga
2021_WB_70630_1
2021/WB/KilliChehlan
Open Tender
Civil Works - Water Works
Item Rate
60 days
Villalge Killi Chehlan
Please refer Tender documents.
9 documents required · 9 mandatory
₹1
₹30,000
1 Dec 2021
25 Aug 2021
6 Sept 2021
25 Aug 2021
6 Sept 2021
25 Aug 2021
Amount
Provision for one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressure upto 7 ka.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications complete in all respects.
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8
Providing & fixing G.I. Barbed wire 3 ply (strands of wire) conforming to IS : 278 fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8
Repair of existing brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-3.(Analysis attached)
Repair of masonry gate pillar including repair , painting and writing of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects. (Analysis attached)
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7
Repair of leakages in Existing pvc pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects (As per Analysis)
(ii) 90 mm o/d pvc pipe
Minor repair in existing household connection (by Providing & fixing washer (electric welded) in the 15mm union on existing water connection etc.), Where water connections were installed by consumers, but not as per DWSS specifications.(Analysis attached)
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp and C.I. Bib cock complete. (As per analysis)
New Household Connections proposed On Existing / Replaced Pipeline
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp and C.I. Bib cock complete. (As per analysis)
New Household Connections on new pipe line
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Tranches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width.(CSR item 28.12,28.13 & 28.18)
xii) PVC Pipe Line 63mm o/d 6 kgf/sq.cm
xiv) PVC Pipe Line 90mm o/d 6 kgf/sq.cm
xv) PVC Pipe Line 110mm o/d 6 kg.f/sqcm
xvi) PVC Pipe Line 160mm o/d 6 kg.f/sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27(A))
a) 80 mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.(CSR item 28.66)
(a) Size (0.60 x 0.60 mtr)
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous coruse 50 to 75 mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respacts as per analysis A-26. NOTE:- Contractor shall quote rates only for dismantling mattle road and back filling with excavated earth, fully compacted. The restoration of the mattled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/Pnnchayti Raj.
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects. (Analysis attached)
Repair of existing sign board with paint and writing complete in all respect.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .