Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.6 L+₹79,000 (5.01%)Rejected-Finance 110 245 NEHRU NAGAR KANPUR UTTAR PRADESH 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹18.8 L+₹3.0 L (19.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Mar 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair/Maintenance of AMF panel battery charger LT panel cables and DG Sets under GE Utilities Udhampur
2020_MES_322875_1
GE/U-60/2019-20
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹40,000
Yes
18 Apr 2020
7 Feb 2020
11 Mar 2020
7 Feb 2020
9 Mar 2020
24 Feb 2020
Amount
(l) Hooter - 01 No (m) AMF Logic - 01 No (n) Auto Manual switch 4 Pole, 2 Way - 01 No (o) Indications 24 V - 04 No (p) Push button with elements - 08 Nos (q) Indications - 03 No (r) Pla Relay - 09 No (s) Auxillary contactor - 02 Nos (t) Control fuse base with links - 06 Nos (u) Battery charger - 01 No
(l) Hooter - 01 No (m) AMF Logic - 01 No (n) Auto Manual switch 4 Pole, 2 Way - 01 No (o) Indications 24 V - 04 No (p) Push button with elements - 08 Nos (q) Indications - 03 No (r) Pla Relay - 09 No (s) Auxillary contactor - 02 Nos (t) Control fuse base with links - 06 Nos (u) Battery charger - 01 No
Dismantling and taking out of old unserviceable LT PanelSupply and installed, testing LT panel outdoor type weather proof panel floor mounted on equal angle CRCA steel sheet dust and vermin proof duly powder coated and wired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI similar design and technology shall be adopted for fabrication of panel, copy of CPRI test report shall be produced to GE along with the certificate from manufacturer of the panel that the similar design and standard have followed in these panels.The panel shall be comprising of following accessories :-Description all as per item No. 2 here-in-before but comprising of following accessories :-
(a) MCCB 600 Amps 4 pole, 415 volts - 01 No. (b) Copper bus bar 4 strip as per rating 800amp -01 Set. (c) MCCB 400 Amps 4 pole, 415 volts- 01 No.. (d) MCCB 200 Amps 4 pole, 415 volts-02 No. (e) ON Load Changeover switch 630Amp (f) Digital Ammeter 0 to 600 Amps with CTs -01 Set (g) Digital Voltmeter 0-500 volts -01 Set (h) Phase indicator for three phase (RYB) -01 Set (set of three). (i) Complete wiring of panel board with PVC insulated copper conductor multi- strand cable -01 Job (j) Blank space for MCCB of rating upto 200 Amps ,4 pole -01 No .
Dismantling and taking out of old unserviceable LT PanelSupply and installed, testing LT panel outdoor type weather proof panel floor mounted on equal angle CRCA steel sheet dust and vermin proof duly powder coated and wired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI similar design and technology shall be adopted for fabrication of panel, copy of CPRI test report shall be produced to GE along with the certificate from manufacturer of the panel that the similar design and standard have followed in these panels.The panel shall be comprising of following accessories :-Description all as per item No. 2 here-in-before but comprising of following accessories: -
(a) MCCB 63 Amps 4 pole, 415 volts - 01 No. (b) Copper bus bar 4 strip as suitable rating-01 Set. (c) MCCB 32 Amps 4 pole, 415 volts- 02 No.. . (d) Four Pole Chageover switch 63Amp AC-23 (Side handle)-01No . (e) Digital Ammeter 0 to 100 Amps with CTs -01 Set (f) Digital Voltmeter 0-500 volts -01 Set (g) Phase indicator for three phase (RYB) -01 Set (set of three). (h) Complete wiring of panel board with PVC insulated copper conductor multi- strand cable -01 Job (i) Blank space for MCCB of rating upto 63 Amps, 4 pole -01 No.
Dismantling and taking out of old unserviceable LT Pane Supply and installed, testing LT panel outdoor type weather proof panel floor mounted on 60 cm long legs made out of 40X40X6mm angle made of complete CRCA sheet on 3.15mm dust and vermin proof duly powder coated and wired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earlier and similar design and technology shall be adopted for fabrication of panel. The panel shall be comprising of following accessories :-
a) MCCB 125 Amps 4 pole. (b) Copper bus bar 4 strip as per 200Amp rating. (c) MCB 63 Amps 4pole - 02 No. (d) 4 Pole on load Chageover switch 100Amp (In Open Execution)-01No (e) Digital Ammeter 0 to 200 Amps. (f) Digital Voltmeter 0-500 volts. (g) Phase indicator. (h) Complete wiring of panel board with appropriate current rating flame retardant PVC insulated copper conductor multi- strand cable for panel intrument incomming / outgoing MCCBs with suitable thimble -01 Job (j) Blank space for MCCB of rating upto 125 Amps, -01 No
M&L for dismantling /opening of incoming, outgoing cable connection carefully including disconnecting /dismantling of burnt voltmeter,ampere meter,frequency meter,indicator lamp and wiring complete of LT panels of DG set at COS stn, 5071 ASC Bn, 222 ASC ,9 R&O Flt,1 FOD AAO,1 FOD kalimata complex, ASCON, 1 Sig Gp, CMDC, Bde Exchange, 3 ASD, 57 WEU complete all as specified and directed by Engr-in-Charge.
M&L for replacement of voltmeter range 0-500 volts make:AE-62342 size as site requirement complete for panel of DG set at COS stn, 5071 ASC Bn, 222 ASC, 9 R&O Flt, 1 FOD AAO, 1 FOD kalimata complex, ASCON, 1 Sig Gp, CMDC, Bde Exchange, 3 ASD, 57 WEU complete all as specified and directed by Engr-in-Charge.
M&L for replacement of ampere meter range 0-200 Amps make:AE size as per site requirement complete for panel of DG set at COS stn,5071 ASC Bn, 222 ASC, 9 R&O Flt, 1 FOD AAO, 1 FOD kalimata complex, ASCON, 1 Sig Gp, CMDC, Bde Exchange, 3 ASD, 57 WEU complete all as specified and directed by Engr-in-Charge.
M&L for supply and fixing frequency meter 4 digit 230 volt size 96 sq mm PT No-100007760783 complete for panel of DG set at COS, ASCON, 1 Sig Gp, 57 WEU complete all as specified and directed by Engr-in-Charge.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and directed by Engr-in-Charge.
M&L for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 sq mm, 3.5 core in trenches or fixing in walls / poles or drawing through pipe complete all as specified and directed by Engr-in-Charge.
M&L for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 70 sq mm, 3.5 core in trenches or fixing in walls / poles or drawing through pipe complete all as specified and directed by Engr-in-Charge.
M&L for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 95sq mm, 3.5 core in trenches or fixing in walls / poles or drawing through pipe complete all as specified and directed by Engr-in-Charge.
M&L for XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 150 sq mm, 3.5 core in trenches or fixing in walls / poles or drawing through pipe complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceding 1.5 mtrs wide and not exceding 1.5 mtrs depth in hard dense soil for laying of underground cable etc and getting out complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: For payment purpose 18 cm thickness shall measured.
S&F burnt brick sub class" B" designation for cable protection laid adjacent to each other perpendicular to the direction of cable in trenches complete all as specified and directed by Engr-in-Charge.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engr-in-Charge.
Dismantling and taking out of old unserviceable Battery Charger, Supply and installed, Battery Charger suitable for charging battery capacity 12volt up to 200AH Model 12-72 BC20A complete all as specified and directed by Engr-in-Charge. Make: Sine Trac.
Supply, laying in trenches or fixed to wall etc cable PVC insulated mult stranded copper conductor single core cable of size 120 sqmm cut to size all as required for connection from DG Set panel to change over and AMF panel including thimble , flexible conduit pipe complete all as specified and directed by Engr-in-Charge. Make: Havell or equivalent of Polycab / Plaza
Supply, laying in trenches or fixed to wall etc cable PVC insulated mult stranded copper conductor single core cable of size 95 sqmm cut to size all as required for connection from DG Set panel to change over and AMF panel including thimble , flexible conduit pipe complete all as specified and directed by Engr-in-Charge. Make: Havell or equivalent of Polycab / Plaza, make of cable L & T / Standard / Havells or equivalent
Supply, laying in trenches or fixed to wall etc cable PVC insulated mult stranded copper conductor single core cable of size 70sqmm cut to size all as required for connection from DG Set panel to change over and AMF panel including thimble , flexible conduit pipe complete all as specified and directed by Engr-in-Charge. Make: Havell or equivalent of Polycab / Plaza
Supply, laying in trenches or fixed to wall etc cable PVC insulated mult stranded copper conductor single core cable of size 50sqmm cut to size all as required for connection from DG Set panel to change over and AMF panel including thimble , flexible conduit pipe complete all as specified and directed by Engr-in-Charge. Make: Havell or equivalent of Polycab / Plaza
SHARMA SALES CORPORATION
PREM NATH KHAJURIA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .