Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.3 LAccepted-AOC | 1 | Accepted-AOC Work awarded to lowest bidder | |
| 2 | 2₹41.7 L+₹3.4 L (8.86%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | 2 | Rejected-Finance L2 bidder | |
| 3 | 3₹43.2 L+₹4.9 L (12.7%)Rejected-Finance | 3 | Rejected-Finance L3 bidder | |
| 4 | 4₹43.5 L+₹5.2 L (13.6%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | 4 | Rejected-Finance L4 bidder |
Tender Value
₹43.3 L
EMD Value
₹86,562
Closing Date
3 Dec 2019, 6:00 pmClosed
Senior Manager Engg E
Senior Manager Engg E, LGBI Airport, Guwahati
Modification of existing Fire Hydrant, Fire Detection and Alarm System at LGBI Airport, Guwahati.
2019_AAI_36037_1
AAI/ENGG/SMEE/GHY/NIT-21/19-20
Open Tender
Electrical Works
Works
120 days
Work
As per NIT
5 documents required · 5 mandatory
₹1,120
AAI
₹86,562
17 Jan 2020
18 Nov 2019
9 Dec 2019
19 Nov 2019
3 Dec 2019
19 Nov 2019
19 Nov 2019 - 28 Nov 2019
Amount
Complete designing of Fire Hydrant System, Fire Detection and Alarm System for the existing Terminal building by engaging specialized manpower / consultant for modification of existing fire hydrant system including detection of leakage in the underground pipings wherever required through suitable methods, converting the existing conventional FDA system into addressable system by utilizing the existing addressable FDA system wherever available, integrating the new devices / proposed system with existing addressable system including preparation and submission of shop drawings, as-built drawings and required documents for obtaining the approval and NOC from local fire authority complete as per latest IS and NBC standards.
TERRACE PUMPSET Supplying, Installation, Testing and Commissioning of electric driven terrace pump of 900 lpm at 35 m Head suitable for automatic operation and consisting of following, complete in all respects, as required as per specifications. (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal etc confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325/ IS-12615. (c) M.S.fabricated common base plate, coupling, coupling guard, anti vibration pads, repairing / plastering of existing foundation etc.as required.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required as per specifications.
80 mm dia
100 mm dia
150 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of post office red shade etc complete as per specifications.
80 mm dia
100 mm dia
Supplying, fixing, testing and commissioning of Butterfly valve of PN 1.6 rating duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes including providing suitable size flanges by welding etc as required complete as per specifications
80 mm dia
100 mm dia
Providing, installation, testing and commissioning of Non-return valve cast Iron double flange as per IS/5312 PN 1.6 rating complete with Rubber gasket, GI bolts, nuts, washers etc. of following sizes confirming to IS: 5312 complete as required as per specifications.
100 mm dia
Supplying and fixing Air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required as per specifications.
Supplying and fixing of 2 way fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for 100 mm dia dia MS pipe connection conforming to IS 904 as required as per specifications.
Supplying and fixing Single headed hydrant landing valve with 1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (Type A) with blank Gunmetal cap and chain as required as per specifications.
Supplying and fixing 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 of 30mtr length as per IS:12585 with 25 mm dia gun metal globe valve & nozzle complete as per specifications.
Providing and fixing weather proof lockable cabinet of size not less than 0.9m x 0.6m x 0.45m made out of MS sheet 2mm thick suitable for housing hydrant post with landing valve, hose reel etc having central opening and 6 mm thick glazed glass doors (Two nos.) suitably marked on the outside with the letters "FIRE" including necessary locking arrangement, mounting legs/concrete pedestal and shall be painted with one coat of primer and two coats of synthetic enamel paint of P.O red shade as required as per specifications.
Providing & fixing of pressure switch (1 to 10 bar) in M.S. pipe line including connection etc. as required.
Providing and fixing in position the industrial type pressure gauges of 100mm dia with gun metal / brass valves complete as required
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5Cx35 Sqmm
4Cx16 Sqmm
Providing and placing cement concrete support blocks of 300mm(L)X200mm(B)X450mm(H) under the existing fire hydrant piping made out in the ratio of 1:2:4 etc complete as required.
Cutting/demolishing of hard bituminous/concrete surfaces/roads upto a thickness of 300mm of required width to enable laying of M.S pipes upto 150mm dia size and finishing the same with 150mm thick cement concrete of 1:3:6 ratio over the excavated road surface after laying of M.S pipe etc complete as required.
Dismantling of existing fire hydrant terrace pump from its location, shifting and transporting the same to AAI stores etc complete as required upto a distance not more than 200 metres etc complete as required.
Dismantling of existing Fire Control Panel from its location, i/c removal of cable termination, shifting and handing over to AAI store upto a distance not more than 200 mtrs etc complete as required.
Dismantling of existing fire hydrant landing valve from its location, carrying out required maintenance, chemical cleaning of internal parts and reinstalling the same at its original location after replacing the internal parts, gaskets etc complete as required.
Dismantling of 80/100/150mm dia NRV/Sluice/Gate/butterfly valves including flanges from the existing fire hydrant pipe lines and transporting the same to AAI stores etc complete as required
Supplying, Installation, Testing and Commissioning of UL/EN Listed (latest version) Micro-processor based Intelligent Addressable Fire Alarm Control Panel with following loops compatable for integrating with existing detectors/devices of Morley IAS/Notifier make and capable of supporting not less than 198 devices (including detectors) and minimum 99 detectors per loop with loop length upto 2 km, network communication card, minimum 240 character graphics/ LCD display with touch screen or keypad, events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications. (To be supplied only if required as per finalized and approved design of FDA system)
01 (One) Loop
02 (Two) Loop
Supplying, installation, testing & commissioning of UL/EN Listed (latest version) Repeater panel with minimum 80 character graphics/LCD display with touch screen or keypad with inbuilt reset, acknowledge and silence switches, provide pin point location of the fault or fire event and should provide complete control of system at remote location and compatable for the existing fire alarm control panel of following makes etc complete as per specifications.
Repeator Panel of Morley IAS make
Repeator Panel of Notifier make
Supply, Installation, Testing & commissioning of UL / EN listed Analogue addressable type Photoelectric smoke detectors compatable for the existing fire alarm control panel of following makes with plug-in base & housing complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space etc complete as per specifications.
Photoelectric smoke detectors of Morley IAS make
Photoelectric smoke detectors of Notifier make
Supply, installation, testing and commissioning of UL / EN listed Analogue addressable Hooter-cum-strobe compatable for the existing fire alarm control panel of following makes complete with termination etc. complete as per specifications.
Hooter-cum- strobe of Morley IAS make
Hooter-cum- strobe of Notifier make
Supply, Installation, Testing & commissioning of UL / EN listed Analogue addressable Manual call station compatable for the existing fire alarm control panel of following makes suitable for semi flush mounting, IP 54 for indoor use & IP 65 for outdoor use with outlet box etc complete as per specifications.
Manual call station of Morley IAS make
Manual call station of Notifier make
Supply, Installation, testing & commissioning of UL / EN listed Analogue addressable of fault isolator compatable for the existing fire alarm control panel of following makes complete with base etc complete as required.
Fault Isolator of Morley IAS make
Fault Isolator of Notifier make
Providing, installation, testing & commissioning of UL / EN listed Analogue addressable Control Module / Relay Module (output module) compatable for the existing fire alarm control panel of following makes complete with termination etc complete as per specifications.
Control Module / Relay Module of Morley IAS make
Control Module / Relay Module of Notifier make
Supplying, Installing, Testing and Commissioning of UL / EN listed Addressable Optical Smoke Imaging Detector (OSID) with Imaging Unit for installing on high ceiling areas including providing suitable monitor module for integrating with existing Morley / Notifier make fire control panel etc complete as per specifications.
Supplying, Installing, Testing and Commissioning of UL / EN listed Addressable Optical Smoke Imaging Detector (OSID) with battery operated Emitter unit for installing on high ceiling areas including providing suitable monitor module for integrating with existing Morley / Notifier make fire control panel etc complete as per specifications.
Supplying, installation, testing & commissioning of Response Indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc complete as per specifications.
Supplying & laying of 2Cx1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath etc complete complete as per specifications.
Supplying and drawing of 2C x 1.5 sq. mm PVC insulated and FRLS sheathed multicore flexible copper conductor cable in the existing surface / recessed steel / PVC conduit as required.
Supplying and fixing of 20mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Dismantling of existing Addressable type 2-loop Fire Alarm Control Panel of Notifier / Morley IAS Make and reinstalling the same in another location, connecting the loop cables, re-programming, testing and commissioning etc complete as required.
Supply and fixing of 4.5kg capacity Carbon dioxide (CO2) type fire extinguishers confirming to IS 15683-2006 and cylinders fully charged including providing wall mounting bracket etc., complete as required.
Providing and fixing of 5kg capacity ABC type dry powder extinguisher as per IS : 2171 consisting of welded MS cylindrical body, with discharge valve, nozzle and CO2 cartidge and hanging arrangement complete as required
GLYPTIC
Pragati Engineering Pvt.Ltd.
CENTRE TAP ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .