Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Found lowest bidder | |
| 2 | L2₹34.8 L+₹3,705.56 (0.11%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹35.8 L+₹1.0 L (2.89%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹38.7 L+₹3.9 L (11.3%)Rejected-Finance 25 SHIV SAROVER COLONY GARH ROAD MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | L4 | Rejected-Finance 4th lowest | |
| 5 | L5₹38.8 L+₹4.1 L (11.7%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance 5th lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
7 Oct 2023, 6:00 pmClosed
GE (North) Meerut Cantt
Office of the GE (North) Meerut Cantt
MAINT AND REPAIRS TO SEWAGE TREATMENT PLANT, LIST WELL OF SOMNATH ENCLAVE AND CEMETRY LINES STP SRC, LIGHTING PROTECTION SYSTEM ALLIED WORKS AT FASF SOFIPUR ETC UNDER AGE E/M-I OF GE (NORTH) MEERUT CANTT
2023_MES_618037_1
8444/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Class D Category b (i)
8 documents required · 8 mandatory
₹500
GE (North) Meerut Cantt
₹1 L
Yes
4 Jan 2024
9 Sept 2023
9 Oct 2023
9 Sept 2023
7 Oct 2023
23 Sept 2023
Amount
M&L for servicing/ maintaining of air compressor machine upto Capacity 600Cum/ Hr with 3 phase, 20HP, 415 Volts, 50 HZ motor complete with cleaning of air tank including replacement of defective parts and lubricating oil to bring into proper serviceable condition of air blower complete all as specified and as directed.
All as per Srl item No 1.00 here-in-before but Capacity 515Cum/ Hr with 15HP motor complete all as specified and as directed.
All as per Srl item No 1.00 here-in-before but Capacity 515 Cum/ Hr with 7.5HP motor complete all as specified and as directed.
All as per Srl item No 1.00 here-in-before but Capacity 515 Cum/ Hr with 5HP motor complete all as specified and as directed. Note for Item No. 1 to 4:- (i) Cost of replacement of minor Spare parts like Injection rings, distance ring, pressing ring, O-ring, tensioning element, oil seal, splash guard, intermediate guard, lock nuts and gaskets, washers, nut bolts etc shall deemed to be included in above quoted rate . (ii) Major Spare parts like Bearing/bushes Lube oil for compressor, V belts shall be measured and paid seperately as "supply only "under relevant item of this Schedule.
Supply only in replacement Ball bearing suitable for Air compressor of 600 Cum /Hr, 20HP capacity complete all as specified and as directed.
Supply only in replacement Ball bearing suitable for above Air compressor of 515 Cum/Hr, 15HP capacity complete all as specified and as directed.
Supply only in replacement Ball bearing suitable for above Air compressor of 515 Cum/Hr, 7.5HP/5 HP capacity complete all as specified and as directed.
Supply only in replacement Lube oil for Air compressor (air blower) Servo 320 complete all as specified and as directed complete all as specified and as directed.
Supply only in replacement 'V' belt suitable for above Air compressor of 600 Cum/Hr, 20HP capacity complete all as specified and as directed.
Supply only in replacement 'V' belt suitable for above Air compressor of 515 Cum/Hr, 15HP capacity complete all as specified and as directed.
Supply only in replacement 'V' belt suitable for above Air compressor of 515 Cum/Hr, 7.5HP/5 HP capacity complete all as specified and as directed.
M&L for removing the submersible pump set (non clog) from existing position, Shifting to authorized workshop for repair work, dismantle / open, removing the burnt winding, cleaning rotor / stator, re-winding the motor with F class insulation super enameled copper wire of size same as the original winding including insulated packing materials, Varnishing, Drying, including replacement of both water seal, filling with new lube oil upto required level etc. re-assembling the pump set, installing back to the original position, testing and commissioning by thorough checking of electric circuit for proper protection of motor and run on full load for 4 hrs continuous running for the motor capacity of upto 3HP of any make complete all as specified and as directed.
All as per Srl item No 12.00 here-in-before but of 5.0 HP to 7.5 HP capacity complete all as specified and as directed.
All as per Srl item No 12.00 here-in-before but of 10HP to 15 HP capacity complete all as specified and as directed.
All as per Srl item No 12.00 here-in-before but of 20HP to 25HP capacity complete all as specified and as directed.
All as per Srl item No 12.00 here-in-before but of 30HP upto 40HP capacity complete all as specified and as directed.
M&L for removing the submersible pump set (non clog) from existing position, Shifting to authorized workshop for repair work, Overhauling and servicing of submersible pump set with motor including replacements of unserviceable nuts, bolts, & washers, seals, packing, opening of delivery casing volute for checking of non clog type impeller, checking and replacement of stuffing box unit seals and mach seal housing / casing cover for checking , checking of seat and replacement of seat ring, checking for smoothness of motor running and clearance between impeller and casing ring and casing cover, greasing of flower bearing of pump set, including Cleaning of 3 phase electric submersible motor in water tight housing testing it for its water tightness by air for its joints including replacements of unserviceable parts as required re-assembling the pump set, installing back to the original position, testing and commissioning on full load for 4 hrs continuous running for the motor capacity upto 3HP complete all as specified and as directed.
All as per Srl item No 17.00 here-in-before but of 5.0 HP to 7.5 HP capacity complete all as specified and as directed.
All as per Srl item No 17.00 here-in-before but of 10HP to 15 HP capacity complete all as specified and as directed.
All as per Srl item No 17.00 here-in-before but of 20HP to 25HP capacity complete all as specified and as directed.
All as per Srl item No 17.00 here-in-before but of 30HP upto 40HP capacity complete all as specified and as directed. Note for Item No. 17 to 21:- (i) Cost of replacement of Minor Spare parts like gun metal neck ring, water seal compound and rubber bushes, and gaskets, washers, nut bolts etc shall deemed to be included in quoted rate. (ii) Major Spare parts like Bearing/bushes, impeller shall be measured and paid seperately as "supply only" under relevant item of this Sch.
Supply only in replacement Non clog impeller suitable for and upto 3HP submersible pump set complete all as specified and as directed.
All as per Srl item No 22.00 here-in-before but of 5.0 HP to 7.5 HP capacity complete all as specified and as directed.
All as per Srl item No 22.00 here-in-before but of 10HP to 15 HP capacity complete all as specified and as directed.
All as per Srl item No 22.00 here-in-before but of 20HP to 25HP capacity complete all as specified and as directed.
All as per Srl item No 22.00 here-in-before but of 30HP upto 40HP capacity complete all as specified and as directed.
Supply only in replacement upper / lower or back to back roller or Ball bearing suitable for and upto 3HP non clog submersible pump set complete all as specified and as directed
All as per Srl item No 27.00 here-in-before but of 5.0 HP to 7.5 HP capacity complete all as specified and as directed.
All as per Srl item No 27.00 here-in-before but of 10HP to 15 HP capacity complete all as specified and as directed.
All as per Srl item No 27.00 here-in-before but of 20HP to 25HP capacity complete all as specified and as directed.
All as per Srl item No 27.00 here-in-before but of 30HP upto 40HP capacity complete all as specified and as directed.
Supply only in replacement Stainless steel bush suitable for and upto 3HP non clog submersible pump set complete all as specified and as directed.
All as per Srl item No 32.00 here-in-before but of 5.0 HP to 7.5 HP capacity complete all as specified and as directed.
All as per Srl item No 32.00 here-in-before but of 10HP to 15 HP capacity complete all as specified and as directed.
All as per Srl item No 32.00 here-in-before but of 20HP to 25HP capacity complete all as specified and as directed.
All as per Srl item No 32.00 here-in-before but of 30HP upto 40HP capacity complete all as specified and as directed.
M&L for dismantling and removing the motor of the mono block / coupled Pump set or Air compressor from existing position, Shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning by thorough checking of electric circuit for proper protection of motor and run on full load for 4 hrs continuous running for the capacity of motor upto 3HP of any make complete all as specified and as directed.
All as per Srl item No 37.00 here-in-before but more than 3HP upto 5HP complete all as specified and as directed.
All as per Srl item No 37.00 here-in-before but more than 5HP upto 7.5HP complete all as specified and as directed.
All as per Srl item No 37.00 here-in-before but more than 7.5HP upto 10HP complete all as specified and as directed.
All as per Srl item No 37.00 here-in-before but more than 10HP upto 15HP complete all as specified and as directed.
All as per Srl item No 37.00 here-in-before but more than 15HP upto 20HP complete all as specified and as directed.
All as per Srl item No 37.00 here-in-before but more than 20HP upto 30HP complete all as specified and as directed.
M&L for Dismantling and removing the mono block / Coupled pump set from the existing position after disconnecting the inlet/outlet pipe connections, disconnecting the electric supply cables and transporting to repair work shop complete, opening the pump side, servicing the pump set including cleaning the shaft including replacement of worn out bearing, bushes, check nut, shaft sleeves etc. and installing back to the original position, testing and commissioning on full load for 4 hrs continuous running for the capacity of pump upto 3HP complete all as specified and as directed.
All as per Srl item No 44.00 here-in-before but more than 3HP upto 5HP complete all as specified and as directed.
All as per Srl item No 44.00 here-in-before but more than 5HP upto 7.5HP complete all as specified and as directed.
All as per Srl item No 44.00 here-in-before but more than 7.5HP upto 10HP complete all as specified and as directed.
All as per Srl item No 44.00 here-in-before but more than 10HP upto 15HP complete all as specified and as directed.
All as per Srl item No 44.00 here-in-before but more than 15HP upto 20HP complete all as specified and as directed.
All as per Srl item No 44.00 here-in-before but more than 25HP upto 30HP complete all as specified and as directed. Note for Item No. 44 to 50:- (i) Cost of replacement of minor Spare parts like gun metal neck ring, rubber coupling/metal coupling and rubber bushes, and gaskets, washers, nut bolts etc shall deemed to be included in above quoted rate . (ii) Major Spare parts like Bearing/bushes, impeller shall be measured and paid seperately as "supply only "under relevant item of this Schedule.
Supply only in replacement Ball bearing of suitable size for and upto 3HP mono block / Coupled pump set complete all as specified and as directed.
All as per Srl item No 51.00 here-in-before but more than 3HP upto 5HP complete all as specified and as directed.
All as per Srl item No 51.00 here-in-before but more than 5HP upto 7.5HP complete all as specified and as directed.
Supply only in replacement roller bearing of suitable size for 7.5HP upto 10HP mono block / Coupled pump set complete all as specified and as directed.
All as per Srl item No 54.00 here-in-before but more than 10HP upto 15HP complete all as specified and as directed.
All as per Srl item No 54.00 here-in-before but more than 15HP upto 20HP complete all as specified and as directed.
All as per Srl item No 54.00 here-in-before but more than 25HP upto 30HP complete all as specified and as directed.
Supply only in replacement brass bush of suitable size for and upto 3HP mono block / Coupled pump set complete all as specified and as directed.
All as per Srl item No 58.00 here-in-before but more than 3HP upto 5HP complete all as specified and as directed.
All as per Srl item No 58.00 here-in-before but more than 5HP upto 7.5HP complete all as specified and as directed.
All as per Srl item No 58.00 here-in-before but more than 10HP upto 15HP complete all as specified and as directed.
All as per Srl item No 58.00 here-in-before but more than 15HP upto 20HP complete all as specified and as directed.
All as per Srl item No 58.00 here-in-before but more than 25HP upto 30HP complete all as specified and as directed.
Supply only in replacement new impeller of suitable size for and upto 3HP mono block / Coupled pump set complete all as specified and as directed.
All as per Srl item No 64.00 here-in-before but more than 3HP upto 5HP complete all as specified and as directed.
All as per Srl item No 64.00 here-in-before but more than 5HP upto 7.5HP complete all as specified and as directed.
All as per Srl item No 64.00 here-in-before but more than 7.5HP upto 10HP complete all as specified and as directed.
All as per Srl item No 64.00 here-in-before but more than 10HP upto 15HP complete all as specified and as directed.
All as per Srl item No 64.00 here-in-before but more than 15HP upto 20HP complete all as specified and as directed.
All as per Srl item No 64.00 here-in-before but more than 25HP upto 30HP complete all as specified and as directed.
M & L in repairs Gland packing of thickness upto 14mm complete all as specified and as directed.
M&L in repairs Air Release valve, suitable size for mono block / Coupled pump set, made out of brass, as per site complete all as specified and as directed.
M&L for cleaning and desisting the sewage lift well of capacity 70 to 100 Cum dewatering the complete well, removing All the deposited sludge, soil and other material from the well including bailing / pumping out muddy water from the well by mean All y or by providing suitable pump sets from bottom level of well, scrapping out the scales / deposits from inner surface of the well thoroughly, washing with bleaching powder and soda ash, cleaning / bailing out settled materials completely by any means and removing sludge to a distance up to 3 km out side of defence land limit and dispose off in low lying area including dewatering as required including whitewash the inner side of sump, painting with existing color on outside & writing 'Tank cleaned on ......(date) with 10 cm size white letter on black surface by engaging skilled artist using first quality synthetic enamel paint complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but more than 100 Cum upto 200 Cum capacity lift well complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but more than 200 Cum upto 350 Cum capacity lift well complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but for Equalization tank of 300 to 400 Cum capacity complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but for Equalization tank of 150 to 200 Cum capacity complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but cleaning of complete Stilling chamber, Coarse screen chamber, Grit chamber upto 10 Cum capacity complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but MBBR tank of volume more than 50 Cum to 100 Cum complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but MBBR tank of volume more than 25 Cum to 50 Cum complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but STP secondary tube settler tank of volume 200 Cum at SRC complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but STP secondary tube settler tank of volume upto 112 Cum complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but Sludge tank of size 10mx10mx4.5m complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but Sludge tank of volume upto 115 Cum complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but STP CC tank (Chlorine contact) upto 25Cum complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but Treated water tank of upto 20 Cum capacity complete all as specified and as directed.
All as per Srl item No 73.00 here-in-before but Treated water tank of size 15mx15mx4mtr (Approx) complete all as specified and as directed. Note for item No 73 to 87 :- (i) Contractor shall arrange his own diesel pump, T&P etc for cleaning purpose and minor spares and consumables like small screws, washers, grease, cleaning agents, Diesel & other consumables etc. and cost of the same shall deemed to be included in the quoted cost. (ii) The unit rate quoted shall deemed to be included draining of water with mechanical equipment and working in water and mud etc. (iii) The unit rate quoted shall deemed to be included All safety precautions which shall be taken while working in STP tank / under ground sump. (iv) Making good to the damages during the cleaning of the tank shall be sole responsibility of the contractor.
M&L for opening of all the inspection door of existing Dual Media filter of size 3050 x 2800mm and Activated carbon filter of size 3150 x 2800 mm, taking out / removing the existing totally impregnated / out lived internal filling filter media, layer wise, without any mixing of each other layer, cleaning the entire filter thoroughly and painting with two coats of epoxy based anti corrosive paint internally and two coats of synthetic enamel paint externally, and segregation of filter media received from DMF / ACF, opening of Header strainer pipe SS wire mesh for filtration of waste water received from chlorine contact tank (sewage treatment plant) cleaning of strainer pipe and incl replacement of worn out pipe of same size and fixing of cleaned filter media in layers and setting back the filters for its proper function and testing complete all as specified and as directed.
M&L for opening of all the inspection door of existing Dual Media filter of capacity suitable upto 730 KLD STP, taking out / removing the existing totally impregnated / out lived internal filling filter media, layer wise, without any mixing of each other layer, cleaning the entire filter thoroughly and painting with two coats of epoxy based anti corrosive paint internally and two coats of synthetic enamel paint externally, and segregation of filter media received from DMF, opening of Header strainer pipe SS wire mesh for filtration of waste water received from chlorine contact tank (sewage treatment plant) cleaning of strainer pipe and incl replacement of worn out pipe of same size and S&F of new filter media as per existing pattern with suitable quantity media in (cum) of different layers of fine sand, coarse silex aggregate and filtration sand and setting back the filters for its proper function and testing complete all as specified and as directed.
M&L in repairs 300 mm internal dia ERW MS Pipe including specials, as per IS, wall thickness not less than 5.4 mm, duly painted with 2 coats of Anti Corrosive Synthetic enamel paint over a coat of Zinc Chromate complete incl necessary welding works etc. complete all as specified and as directed.
All as per Srl item No 90.00 here-in-before but 200 mm internal dia complete all as specified and as directed.
All as per Srl item No 90.00 here-in-before but 150 mm internal dia complete all as specified and as directed.
All as per Srl item No 90.00 here-in-before but 100 mm internal dia complete all as specified and as directed.
M&L in replacement 200mm internal dia Reinforced cement concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
M&L in replacement 300mm internal dia Reinforced cement concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
M&L in replacement 400/450mm internal dia Reinforced cement concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
M&L in repairs 20 mm bore GI tubing medium grade incl All fittings, cutting and threaded in any length laid in trenches or fixed to walls complete all as specified and as directed.
All as per Srl item No 97.00 here-in-before but 25 mm bore complete all as specified and as directed.
All as per Srl item No 97.00 here-in-before but 40 mm bore complete all as specified and as directed.
All as per Srl item No 97.00 here-in-before but 80 mm bore complete all as specified and as directed.
M&L in repairs 100mm bore HDPE pipe of pressure rating 10 Kgf / Sqcm including all fittings, in any length, with fusion joint, laid in trenches / fixed to walls complete all as specified and as directed.
All as per Srl item No 101.00 here-in-before but 80 mm bore complete all as specified and as directed.
All as per Srl item No 101.00 here-in-before but 50 mm bore complete all as specified and as directed.
All as per Srl item No 101.00 here-in-before but 25 mm bore complete all as specified and as directed. Note for item Nos 90.00 to 104.00:- Necessary excavation & Earth work shall be measured and paid seperately under relevant items of this sch.
S&F in repairs hand gear butterfly valve with CI Disc and neoprene lining, suitable for 150mm internal dia pipe, ISI Marked, of pressure rating not less than 15Kg/Sqcm, flanged type including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. complete all as specified and as directed.
All as per Srl item No 105.00 here-in-before but for 100 mm dia complete all as specified and as directed.
All as per Srl item No 105.00 here-in-before but for 80 mm dia complete all as specified and as directed.
M&L in repairs Dual plates CI wafer type Non Return / Check Butterfly valve, suitable for 100 mm bore pipe, tested to pressure of 15Kg/Sqcm, flanged type, including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. complete all as specified and as directed.
M&L for preparing the surface by scrapping the old painting and removing the grease, oil, dirt, algae etc. and painting of outer surfaces of MS pipes of size 300 mm internal dia including its MS supports / clamps / nuts / bolts with one coat of black paint over and including a coat of Zinc Chromate primer complete and marking / writing flow arrows and name with white paint by skilled painter complete all as specified and as directed.
All as per Srl item No 109.00 here-in-before but 200 mm internal dia complete all as specified and as directed.
All as per Srl item No 109.00 here-in-before but 150 mm internal dia complete all as specified and as directed.
All as per Srl item No 109.00 here-in-before but 100 mm internal dia complete all as specified and as directed.
All as per Srl item No 109.00 here-in-before but 80 mm internal dia complete all as specified and as directed.
All as per Srl item No 109.00 here-in-before but 20 to 50 mm internal dia complete all as specified and as directed.
M&L for preparing the surface by scrapping the old painting and removing the grease, oil, dirt, algae etc. Painting of outer surfaces of MS gate of size upto 2x2 meter apprx with one coat of black paint over and including a coat of Zinc Chromate primer complete all as specified and as directed.
M&L for preparing the surface by scrapping the old painting and removing the grease, oil, dirt etc, Spray painting with one coat of super enameled anti corrosive paint of approved colour, over a coat of auto primer on external metallic surfaces including frame / base channel for Air Compressor upto Cap 515 Cum/ Hr including motor of capacity upto 15HP complete all as specified and as directed.
All as per Srl item No 116.00 here-in-before but for Air Compressor Cap 600Cum/ Hr including motor of capacity 20HP complete all as specified and as directed.
All as per Srl item No 116.00 here-in-before but centrifugal pump set ,monoblock or coupled of capacity upto 7.5 HP complete all as specified and as directed.
All as per Srl item No 116.00 here-in-before but 10HP to 20HP complete all as specified and as directed.
Supply, fixing & connecting in repair MCB SP 6 to 32 A, AC, 240V,10KA 'C' curve ISI Marked complete all as specified and as directed.
Supply, fixing & connecting in repair MCB SPN, 32A, AC, 240V, 10KA 'C' curve ISI Marked complete all as specified and as directed.
Supply, fixing & connecting in repair MCB TPN/4P, 16 to 32A, AC, 415V, 10KA C' curve ISI Marked complete all as specified and as directed.
Supply, fixing & connecting in repair MCB TPN/4P, 40 to 100A, AC, 415V,10KA C' curve ISI Marked complete all as specified and as directed.
Supply, fixing & connecting in repair Motor Protection Circuit Breaker 3 pole, 415 V, 50/63 Amps, with over load relay range 40 to 80 Amps complete all as specified and as directed.
All as per Srl item No 124.00 here-in-before but 25 Amps with over load release range 20 to 32 Amps complete all as specified and as directed.
Supply, fixing & connecting in repair Single Phase Preventer suitable for motor protection complete all as specified and as directed.
Supply, fixing & connecting in repair 3 phase Contactor 10 Amp 415V with 230V coil complete all as specified and as directed.
Supply, fixing & connecting in repair 3 phase Contactor 16 Amp 415V with 230V coil complete all as specified and as directed.
Supply, fixing & connecting in repair 3 phase Contactor 25 Amp 415V with 230V coil complete all as specified and as directed.
Supply, fixing & connecting in repair 3 phase Contactor 32/40 Amp 415V with 230V coil complete all as specified and as directed.
Supply, fixing & connecting in repair 3 phase Contactor 50/60 Amp 415V with 230V coil complete all as specified and as directed.
Supply, fixing & connecting in repair 3 phase Contactor 63/80 Amp 415V with 230V coil complete all as specified and as directed.
Supply, fixing & connecting in repair NO-NC auxiliary contact block suitable for 10 to 25A 3 phase contactors complete all as specified and as directed..
Supply, fixing & connecting in repair NO-NC auxiliary contact block suitable for 32 to 63A 3 phase complete all as specified and as directed.
Supply, fixing & connecting in repair No volt coil 230V, suitable for 3 phase 415V Contactors complete all as specified and as directed.
Supply, fixing & connecting in repair Plug in control relay 8 pin 24V DC/240 volts AC 9.5 KΩ with socket & clamp base two/three Change over in build mechanical indicator/latching facility and 1 NO-1NC, suitable for AC/DC complete all as specified and as directed.
Supply, fixing & connecting in repair over load Relay 3 Phase, 415V, 1.4 Amp to 6.0 amp complete all as specified and as directed.
Supply, fixing & connecting in repair over load Relay 3 Phase, 415V, 25 Amp to 40 Amp complete all as specified and as directed.
Supply, fixing & connecting in repair DOL starter suitable for upto 5HP motor, 3 Phase, 415 V, with 1Ø preventer and thermal relays complete all as specified and as directed.
Supply, fixing & connecting in repair DOL starter suitable for upto 7.5HP/10HP motor, 3 Phase, 415 V, with 1Ø preventer and thermal relays complete all as specified and as directed.
Supply, fixing & connecting in repair fully automatic star delta motor starter suitable for 15 to 22 HP pump set, 3 phase, 415 V with relay range of 45 to 75 Amps incl enclosure complete all as specified and as directed.
Supply, fixing & connecting in repair fully automatic star delta motor starter suitable for 30 / 40 HP pump set, 3 phase, 415 V with relay range of 45 to 75 Amps incl enclosure complete all as specified and as directed.
S&F in repair copper cable 1.5 Sqmm, single core, copper, multistranded, PVC insulated FR, 1100V grade complete all as specified and as directed.
S&F in repair copper cable 2.5 Sqmm, single core, copper, multistranded, PVC insulated FR, 1100V grade complete all as specified and as directed.
Supply only insulation tape roll 20 mm wide 15 mtr long ISI marked complete all as specified and directed. Make: Steelgrip/Kinjal/Anchor
S&F in repairs, 1100 volts grade heavy duty PVC sheathed stranded Aluminium conductor twin core cable flat or circular of size 6 Sqmm complete all as specified and as directed.
S&F in repairs, 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16KA with Thermal Magnetic Release complete all as specified and as directed.
All as per Srl item No 146.00 here-in-before but 100Amps complete all as specified and as directed.
All as per Srl item No 146.00 here-in-before but 200Amps. 25KA complete all as specified and as directed.
S&F in replacement Post Top Lantern with acrylic dome suitable for and incl B22 LED lamp12 Watts complete all as specified and as directed.
S&F in repairs, testing pilot lamps LED type with integral circuit & cluster LED suitable for operating at 240 /220 Volts complete all as specified and as directed. Make: BCH/C & S Electric /L&T / Siemens.
S&F in repairs, Pressure Gauge, 100mm dia, 0 - 14 Kg/Sqcm pressure rating complete all as specified and as directed. Make: Lub / Meco / H Guru / Pfizer
All as per Srl item No 153.00 here-in-before but 0 - 21 Kg/Sqcm complete all as specified and as directed.
Supply and Laying in trenches or fixed to wall / pole, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade laid in trenches/ fixed in wall / pole of cross sectional area of cable 10 Sqmm 2 core incl taking down old unsv cable complete all as specified and as directed.
All as per Srl item No 155.00 here-in-before but 16 Sqmm 4 core complete all as specified and as directed.
All as per Srl item No 155.00 here-in-before but 35 Sqmm 3.5 core complete all as specified and as directed.
All as per Srl item No 155.00 here-in-before but 50 Sqmm 3.5 core complete all as specified and as directed.
All as per Srl item No 155.00 here-in-before but 95 Sqmm 3.5 core complete all as specified and as directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for laying of Cable or Pipe, electric pole, stay assembly etc. not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
M&L for cutting hard standing / Road cutting for taking up or laying of LT UG cable upto a depth of 15 cm and after laying of cable, well ramming to the excavated soil and repair the cutting / excavated portion of road by providing PCC (1:2:4) type B1 (using 20mm graded stone aggregate) complete all as specified and as directed. Note: Excavation/Earthwork below the depth of 15 cm shall be measured and paid seperately under relevant items.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm. in soft/ loose soil complete all as specified and as directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point in soft/ loose soil complete all as specified and as directed.
Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable / cable duct complete all as specified and as directed. (Only punned thickness shall be measured for payment purpose)
M&L for laying burnt clay fly ash old size bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over under ground cable for protection complete all as specified and as directed.
M&L in replacement 40 mm bore Galvanized steel tubing, light grade, with All fittings for protection of cable including taking down old, rusted & corroded Galvanized steel tubing complete all as specified and as directed.
M&L in replacement 80 mm bore Galvanized steel tubing, light grade, with All fittings for protection of cable including taking down old, rusted & corroded Galvanized steel tubing complete all as specified and as directed.
S&F in replacement, heavy duty cloth strips of filter press as per existing frame with 500 GSM and complete over hauling of filter press incl testing complete all as specified and as directed
S&F in replacement, Rotometer / Air flow indicator as per existing at site including required minor spares and T&P complete all as specified and as directed
M&L for removing of manhole cover, cleaning / removal of sludge / solid wastes / debries in any quantity from any depth which is blocking the smooth flow of sewage lines , well flushing, incl disposal of removed sludge / waste material to designated local body approved places and refixing the man hole cover in same position complete all as specified and as directed. Note: Necessary T&P and consumables shall deemed be included in the quoted rate.
M&L for removing of manhole cover, cleaning / clearing the blocks of sewage lines by providing using split bamboo / solid PVC pipes or any other means for removal of blockage by debries / sludge / solid waste including well flushing for smooth gravity flow of sewage and refixing the man hole cover in same position for 300 mm to 400 mm dia RCC / SGSW pipe complete all as specified and as directed.
All as per Srl item No 171.00 here-in-before 150 mm to 250 mm dia complete all as specified and as directed. Note for Item No.171.00 & 172.00 :- Necessary T&P and consumables shall deemed to be included in quoted rate.
M&L for precast RCC rectangular man hole cover of size 100cm x 45cm x 7.5cm thick made out of PCC 1:2:4 type B1 using 20 mm stone aggregate with 8 mm dia steel rod, 75mm centre to centre, both ways, incl binding wire and 2 Nos of lifting handle moveable type incl dismantling of old broken and removal of debries from site complete all as specified and as directed.
All as per Srl item No 173.00 here-in-before but circular of size 80cm dia x 7.5cm thick complete all as specified and as directed.
M&L for Structural Steel Work, made out of Fe 410-W (Gde-E-250) quality-A Rolled Mild Steel Channel, Angle or Tee Sections, MS sheet with hinges & locking arrangements etc. cut to shape / ordinary length, drilled and countersunk for Screws / Bolts, including bending and welding duly painted with 2 coats of Anti Corrosive Synthetic enamel paint over a coat of Zinc Chromate as in framed work with MS Sheet cover complete all as specified and as directed.
M&L for Cement concrete for coping / support / foundation of GI pipes, Pump sets etc. incl necessary breaking or digging of floor, Type B1, 1:2:4, using 20 mm graded stone aggregate incl necessary form work and finish to exposed surface complete all as specified and as directed
S&F in replacement, medium duty manually operated chain pulley block 1 Ton capacity, 10 Meter standard lift complete all as specified and as directed.
S&F in replacement, HDPE virgin FAB white/black media particle complete all as specified and as directed.
Supply only DWPE (Dewatering Polyelectrolyte) powder, pack of 10/25Kg in polythene bags / HDPE drums complete all as specified and as directed
Supply only CHLORINE 65%-70% calcium based granular, disinfectant for STP water, pack of 40/45 Kg in HDPE drums complete all as specified and as directed
Supply only Sodium Hypo Chloride (10%) in Liquid form, as purifier of STP water, packing in 50 Ltr Can complete all as specified and as directed.
Supply only Calcium Hydroxide (Lime, 80-85%) in Powder form as pH Booster for STP water, packing in 40 Kg Sacks complete all as specified and as directed
Supply only Bacteria culture in PVC shells suitable for MBBR type plant complete all as specified and as directed.
Supply only DAP fertilizer for day to day use in sewage treatment plant complete all as specified and as directed.
Supply only Molasses (Sheera) for day to day use in sewage treatment plant complete all as specified and as directed.
Supply only Poly aluminium chloride chemical for day to day use in sewage treatment plant complete all as specified and as directed.
S&F of LT submersible copper conductor cable of size 16 Sqmm 3 core complete all as specified and as directed.
S&F of LT submersible copper conductor cable of size 6 Sqmm 3 core complete all as specified and as directed.
S&F of LT submersible copper conductor cable of size 10 Sqmm 3 core complete all as specified and as directed.
M&L for cutting and removing of grass/bushes etc of any height grown inside STP premises and surrounding lift wells to keep the site clean and to carryout day to day maint and operations safely, grass cutting to be done as per site requirements & to the satisfactory level complete all as specified and as directed
Supply, fixing and connecting in replacement 45 watts LED integrated street / security light fitting with All accessories along with 32 mm GI bracket with suitable clamps, bolts, nuts & washers incl provision of two core 2.5 Sqmm stranded Aluminium conductor cable of suitable length complete all as specified and as directed.
Taking down old unserviceable street light loop-in and loop out box by disconnecting electrical connection and removing existing clamps, nuts, bolts, and washers and supply, fixing and connecting, factory made out door type syntex street light loop-in and loop out box comprising with suitable size of bus bar, insulators, connectors etc and with one No 6 Amp MCB SP, 415 Volts C curve, one PVC way connector etc. incl suitable size clamps, nuts, bolts & washers complete all as specified and as directed
M&L for Scraping, cleaning and preparation of old surfaces of steel tubular pole (9 Meter long) complete and applying one coat of aluminium paint over a coat of Zinc Chromate complete all as specified and as directed
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (Earth pit not less than 2.25M deep below ground level) with top edge of earth plate 1.5M deep below normal ground level connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel incl necessary excavation, earth work in any type of soil, 1:3:6 type C1 PCC chamber, RCC chamber cover, watering pipe, funnel etc All as shown in electrical plate No 3 of SSR part I connected to earthing test point All as indicated including testing on completion complete all as specified and as directed. Note:- Earth strip upto 7.5mtr deemed to be included in above quoted rate.
All as per Srl Item No 194.00 here-in-before but earthing with 4mm dia GI earth lead wire complete all as specified and as directed.
S&F fine bubble air diffuser of size 3" dia , 1 meter long complete all as specified and as directed.
Repair and servicing of Dozing pump (0.5HP/1HP) & incl replacement of minor spare parts for smooth function of the pump complete all as specified and as directed.
M&L for attending complaints by deploy an expert/ skilled technician to check the fault of Electric control panels of any type installed at STP & Lift wells for any non functional of electronic/ electric control switches, metering equipment, circuit control wiring and rep/ replacement of necessary items to bring the panel system into serviceable state complete all as specified and as directed. Note:- Spare parts shall be measured and paid seperately under relevant item of this Sch.
M&L Earthing with copper plate of size 60cm x 60cm x 3.15mm thick electrode and 20 x 3 mm copper strip as earthing lead, burried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to copper earth strip by means of bolts, nuts, check nuts and washers all as shown in electrical plate No 5 connected to earthing test points all as described in MES schedule Part I including excavation, earth work concrete pit with 50mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 6mm dia @ 150C/G both ways and pit chamber in PCC 1:2:4 TYPE B-1 with 2 No's suitable lifting handles of 12mm MS bar and GI protection pipe of 20mm dia and watering pipe 20 mm dia with washer funnel with wire mesh, test point and extra length up to 7.5 meter (beyond 7.5 meter will be measured seperately) connected to main switch board/terminal block complete all as specified and as directed. Note :- On testing after completion, if desired earth resistance not more than 1.0 Ohms is not obtained the earthing shall be redone without any extra cost to Govt.
M&L test point terminal block made of gun metal or phosphorus of size 75 x 75 x 25mm drilled and screwed including 3 No's 08 mm dia, 25mm long hex heat screws including sheet metal box of suitable size complete all as specified and as directed.
M&L for fixing the Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
M&L for making good the damaged portion of PCC work, with suitable PCC 1:2:4 type B-1 including of chamber cover as per site requirement complete all as specified and as directed.
M&L 20 x 3mm copper strip as in earth continuity conductor or main earthing lead, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required with fixing saddles complete all as specified and as directed.
M&L 25 x 3mm aluminium strip as in earth continuity conductor or main earthing lead, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required with fixing saddles complete all as specified and as directed.
S&F in repair Flame proof light fitting batten including LED tube, 20W of CIMFR certified, IP 65 protection complete all as specified and as directed.
S&F in repair Flame proof integral well glass light fitting of capacity 60W, IP 65/66 protection, suitable to fixed on wall complete all as specified and as directed.
S&F in repair flame proof rotary switch for ON & OFF flame proof lighting of 10A rating, IP 65/ 66 protection complete all as specified and as directed.
S&F in repair flame proof switch socket combine of 16 to 32A rating, IP 65/66 protection complete all as specified and as directed.
S&F in replacement horizontal double mounting siren range 1.5 KM audible ,AC 230V, including suitable HP motor complete all as specified and as directed.
M&L for servicing, repair & rewinding of electric siren of single phase/three phase of any type and capacity motor including testing to the satisfactory function of Siren/hooter complete all as specified and as directed.
Jain Traders
UNIQUE ENGINEERS INDIA
A.V. ASSOCIATES
Shikha Enterprises
NITHYA INFRATECH
M K ENGG CO
BABBAR ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .