| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹7.3 L+₹35,542.25 (5.08%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹7.8 L+₹83,861.40 (12.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹8.3 L+₹1.4 L (19.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹9.4 L
EMD Value
₹19,000
Closing Date
18 Jan 2022, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
PROVN OF 10000 LTR CAPACITY WATER STORAGE TANK WITH STAGING IN DIALYSIS CENTRE AND ADDN/ALTN TO TOILET BLOCK BEHIND IT CELL AT 7 AFH KANPUR CANTT
2021_MES_496979_1
GE(AF)/CHK/T-28 OF 2021-22
Open Tender
Civil Works
Item Rate
120 days
7AFH Kanpur Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹19,000
4 Feb 2022
23 Dec 2021
24 Jan 2022
23 Dec 2021
18 Jan 2022
6 Jan 2022
23 Dec 2021 - 31 Dec 2021
Amount
Excavation over area not exceeding 1.5 m deep and getting out in soft loose soil complete all as specified and directed.
M & L PCC (1:4:8) type D-2 using 40 mm grqaded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 CM complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at l level not exceeding 1.5 mtr above the starting point.
M & L for RCC M-25 in foundation including raft footing etc complete all as specified.
M & L for RCC M-25 in wall, retailing wall basement ballast wall and like all as specified and directed.
M & L for slab supported on wall beams and columns in floors rooft etc complete all as specified and directed.
Form work to side of concrete foundation, footing base of column etc complete all as specified and directed.
Form work to side of wall, retaining wall, wall abetment etc complete all as specified and directed.
Form work to side and soffit of slab supported on wall or beams complete all as specified and directed.
M & L for mild steel bars 10 mm dia and over cut to length bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (Annealed) not less than 0.90 mm dia or securing with clips quality conforming to Fe-410 complete all as specified and directed.
Ditto all as per item No.11 above but for 5 mm dia and over upto and including 10 mm dia as in stirrups spacers and binders.
S & F hoisting PVC tank of 5000 ltr capacity including supplied and fixed 20mm dia PTMT ball valve high pressure with epoxy coated alm rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
S & F 15 mm bore GI tubes medium grade with all fittings and fixed complete to wall and ceiling or laid in floors of any length, complete all as specified and as directed.
S & F 20 mm bore GI medium grade with all fitting and fixed complete to walls and ceiling ot laid in floors of any length complete all as specified and as directed.
S & F Gun metal, globe or gate valve of 15mm dia , with iron wheel head, screwed bith ends for iron pipe complete all as specified and as directed.
S & F Gun metal, globe or gate valve of 20mm dia, with iron wheel head, screwed bith ends for iron pipe complete all as specified and as directed.
S & F steel work as stair case, balustar, hand rail etc and directed complete all as specified and as directed.
M & L for two coat of synthetic enamel paint over a coat of primer including preparation on steel surfaces of any description over 10 cm width or grith complete all as specified and as directed.
M & L for hardcore of gauge exceeding 63 mm but not exceeding 100 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered abd rolled/rammed to a true surface in broken stone or boulder in formation surfaces complete all as specified and as directed.
M & L for 100 mm thick PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in subbase/floor complete all as specified and directed.
Demolition of brick work or rubbled stone masonry including all qoins arches, pillars etc built in cement mortar complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exceeding 1.5 Sqm each complete all as specified and directed.
S & F Solid PVC Door Frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with M.S. Square tube complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC S & F sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed.
S & F butt hinges of size 100 mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised fixed type C-21 complete all as specified and directed
S & F aluminium anodised barrel tower bolts of extruded section, length of bolt 150mm complete all as specified and directed.
S & F aluminium alloy anodized sliding door bolt with hasp staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminium alloy length of bolt 250mm complete all as specified and directed.
M & L for 7 to 8 mm thick non skid ceramic, coloured, joint free tiles square or rectangular of size exc 0.06 sqm but not exc 0.11 sqm as in floors laid over and including 15 mm thick screed bed in CM (1:6) jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including dismantling of old tiles and removing the same from site complete all as specified and directed.
M & L for 7-8 mm thick glazed coloured ceremic joint free tiles in vertical surface 600 mm X 300 mm/450 mm x 300 mm size as required, set over and including 10 mm thick rendering CM (1:4) jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles including dismantling of old tiles and removing the same from site, complete all as specified and directed.
S & F 15 mm bore anlge cock, cast copper alloy cromium plated, screwed down, high pressure, with capstan screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F 15 mm bore fancy type CP bib taps (long body) cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 20 mm dia Tubular towel rail of brass chromium plated, D type, 60cm long between flanges, complete all as specified and directed.
S & F 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer as in roofing, wall etc complete all as specified and directed.
Taking down cement plaster on brick walls including raking out joints hacking for key scrubing down with water etc.complete all as specified and directed.
M & L for rendering 15 mm thick in CM (1:6) finished even and smooth without using extra cement and applying two coat oil bound distemper over a coat of cement base primer after preparation of surfaces complete all as specified and directed.
M & L for rendering 15 mm thick in CM (1:4) finished surfaces even and smooth without using extra cement, for applying two or more coat coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade(company depot tinted) with silicon additive @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new plastered surfaces complete all as specified and directed.
Demolition of PCC not exceeding 15 cm thickness in floors, roofs or pavings and throwing debris at low lying area not exceeding 1 km complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protcetion and coartyard laid in slope 1:40, finished cement surfaces even and smooth without using extra cement complete all as specified and directed.
Dismantling structural steel work including doors, gates, cattle traps etc, but excluding framed truss etc complete all as specified and directed.
M & L for mild steel framed work such as grills, grating, etc. with ends of Bar shouldered and/or riveted or forged into Spikes, Framed Guard Bars and Similar Work, etc. conforming to Fe-290 Gde E-165 including all necessary drilling, bolting or riveting, etc., complete all as specified and directed.
S & F steel work as in strutts, purling, rafter etc complete all as specified and directed.
Dismantling of old water tank exceeding 250 Ltr & but not exceeding 500 Ltr capacity and supply & fixing, PVC tank of 500 ltr capacity three layered, hoisted, including 20 mm dia PTMT ball valve high pressure with epoxy coated alm rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
M & L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in Floors, complete all as specified and directed.
M & L for 25 mm thick PCC(1:2:4) type B-1 using 20 mm graded stone aggregate as in sub fase of floor tiles etc, complete all as specified and as directed.
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose, pendant holder, fitting and fixtures, MCB DB’s, MCB, Main switches, call bell etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper or white colour complete wash all as required and directed.
M & L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sqmm, 1100 V concealed wiring drawn in and including non metallic PVC conduit medium complete including cast iron/pressed steel terminal box 1.6 mm thick of required size bakelite sheet 3 mm thick for mounting switch , socket brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following :-
One light /fan point controlled by one, one way switch
One 5/6 Amp socket on the same board with other switch
One 5/6 Amp socket on independent board.
One 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 1.5 Sqmm
S & F in replacement switch piano type 240 V, 5 Amp, SP one way flush type complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps complete all as specified and directed.
S & F in replacement of socket out let combination multipurpose 3 Pin 5 amp, 240 volt and with 2 pin 5 amp out let also flush type including for existing points also (non shuttered) complete all as specified and directed.
S & F in replacement of switch socket outlet combination 3 pin 15 Amp, 3 Pin 5 Amp out let also flush type (non shuttered) including for existing points complete all as specified and directed.
S & F in replacement ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S & F for lamp holder metal cased body of brass with back plate complete with 5 Watt LED lamp of make - C&S Cat Part No LTHPLEDLAMP5W/B22 or equivalent make in Crompton Greaves/Philips/Bajaj as approved by GE in writing.
S & F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
S & F in replacement MCB SP upto 6-30 Amp ,240 Volt complete all as specified and directed.
S & F in replacement Isolator SPN , 20 to 40 Amp , 240 Volt complete all as specified and directed.
M & L for replacement of regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including pit chamber in PCC (1:3:6) type C-2 using 40 mm graded stone aggregate RCC (1:2:4) Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40 mm dia light grade GI pipe for earth strip 4 mm protection etc. complete all as specified and directed.
M & L for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable concealed wiring drawn in and including non metallic PVC conduit medium complete with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly, including taking out the old sub main wiring complete all as specified and directed. (Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run).
S & F LED light fitting 1 x20W, 220V, AC decoreative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F in repair of sheet metal enclosures with 2 pins and earth plug single pole neutral link and one No MCB SP 20 amp complete all as specified and directed.
kailash brothers
Khalil Ahmed and Sons
SAXENA BANDHU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .