Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-Finance | L1 | Accepted-Finance Lowest and Reasonable | |
| 2 | L2₹36.5 L+₹74,224 (2.08%)Rejected-Finance 25 KASHIPUR KASHIPUR BALLIA UTTAR PRADESH 277001 | BALLIA | UTTAR PRADESH | 277001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.6 L+₹83,969 (2.35%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.0 L+₹1.3 L (3.52%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹38.9 L+₹3.2 L (9.02%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
25 Aug 2023, 6:00 pmClosed
GE (AF) Srinagar
Military Engineer Services Garrison Engineer (AF) Srinagar Air Force Station Srinagar-190007
CERTAIN MAINT OF BR AND EM WORKS AT 45 WEU AND REPAIR OF STATIC WATER TANK, FIRING RANGE, FENCING AND OTHER ALLIED MISC WORK UNDER GE (AF) SRINAGAR.
2023_MES_598527_2
GE(AF)SGR-34 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SRINAGAR
Al as per Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) SRINAGAR
₹96,000
Yes
6 Sept 2023
8 Aug 2023
26 Aug 2023
8 Aug 2023
25 Aug 2023
15 Aug 2023
Amount
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
Brick work with sub class 'B" old size bricks straight or curved of onplan to any radius in half brick thick walls built in CM 1:4 complete all as spfd.
Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as spfd.
All as per item No 03 above here-in-before but except bricks. Note:- Old brick retrieved vide item No 1 above shall be reused.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L rendering 15mm thick CM 1:6 on fair faces of brickwork or concrete surfaces finished even & smooth w/o using extra cement.
Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth using integral water proofing compound complete all as specified and as directed by Engineer-in-Charge. (WPC shall be measured and paid seperately)
Supply only integral water proofing compound.
Dismantling of floor hearth or wall tiling including cement mortor bedding but not backing.
M&L joint fee non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as spfd. colour and design approved by Engr-in - Charge.
M&L ceramic glazed colour digital tiles as in vertical surfaces such as skirting ,dados etc with area of each tile exc.0.11 sqm and not exc. 0.18 sqm 7-8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface incl. 10 mm thick plaster in CM 1:3 complete all as specified colour and design approved by Engr-in-Charge.
M&L joint free non-skid coloured designer ceramic tiles area of each tile exceeding 0.11 sqm but not exc. 0.18 sqm ,7-8 mm thick in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as spfd. colour and design approved by Engr-in - Charge.
M&L coloured vitrified tiles 10 mm thick polished area of each tiles not exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as spfd colour and design approved by Engr-in-Charge.
All as per item No. 13 above but on vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on masonry / concrete surfaces complete all as spfd colour and design approved by Engr-in-Charge.
M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as spfd colour and design approved by Engr-in-Charge.
M&L in repair 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.including screed bed bedding layer of 15 mm thick in CM1:4 complete all as secified.and polished complete.
Taking down shutters of any description exc. 1 sqm and n.exc 2 sqm each and removing from site.
Taking down chowkats or frames with shutters without taking off shutters from the frames, area n.exc 1.50 sqm each and removal to store including cutting holes for removal of hold fast complete all as specified.
Taking down chowkhats and frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters without taking off shutters from the frames, and removal to store including cutting holes for removal of hold fast complete all as specified.
Supply and fixing 2nd class hard wood 35 mm thick factory made plain framed paneled shutters with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces including mouldings fixed to chowkats, complete all as specified.
Supply and fixing 2nd class hardwood 35 mm thick factory made glazed and skelton shutters to receive glass/ gauge of with sash bars for windows/ventilators fixed in position complete all as specified in SSR Part-I Sec 8 clause 8.20(a) complete all as specified.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F Factory made PVC single door frame of size 50x47mm with a wall thickness of 5mm plain colour sheet reinforced with 19mm x 19mm MS square tube having wall thickness 19 gauge complete all as shown in sketch on page 160 of SSR 2010 part-II. The door frame to be fixed to the wall using MS screw 75mm long with PVC fastener complete as per manufacturing, instruction complete all as specified.
S&F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tube 19mm x 19mm having wall thickness 19 gauge for stiles MS tube 15mm x 15mm having wall thickness for top and bottom rails MS frame shall be covered with 5mm thick heat moulded plain colour PVC ‘C’ channel having 5mm thick PVC sheet strip 20mm wide struck inside with solvent cement for stiles and 5mm thick PVC sheet for top rail, lock rail and bottom rail on either side and 10mm (5mmx2mm) thick, 20mm wide cross PVC sheet as gap insert for top and bottom rail Paneling of 5mm thick plain colour PVC sheet to be fixed in MS frame welded / sealed to the stiles and rails with 5mm x 30mm PVC sheet beading
and jointed together with solvent cement complete all as shown in drg. given on page 156 of SSR 2010 part II. The width of stiles and rails shall be as specified in para 8B, 21 on page 156 of SSR 2010 part II. Each PVC door shutter leaf consists of 4 Nos 100 mm long MS butt hinges complete all as specified.
S&F powder coated (minimum thickness of powder coating 50 micron)anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge
S&F repair for powder coating of any colour anodised aluminium door shutters, (Thickness or powder coating not less than 50 micron) aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, 150 mm handles 2 Nos in each door shutter, 100 mm hinges-03 Nos, 150mm tower bolt -02 nos in each shutter anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge.
S&F for powder coating of any colour Anodised aluminium window and ventilator shutters, (Thickness or powder coating not less than 50 micron) side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21, 100mm long (2 no) suitable handle (1 no), complete all as specified and directed by Engineer-in-Charge.
S & F sheet glass 5.5mm thick, ordinary quality and glazing with aluminium glazing clips and rubber neosprine gasket in square or rectangular, complete all as specified and directed by Engineer-in-Charge.
S&F aluminium composite panels, 5mm thick as in doors / paneling, of any colour, shape, size and design fixed on aluminium frame work including all necessary fittings and fixtures and necessary taping, complete all as per manufactures instructions, complete all as specified.
Taking up or down 15 mm bore steel tubing & connections from walls etc.
Taking up or down 20 mm bore steel tubing & connections from walls etc.
S&F for 15 mm Bore Steel Water Tubing 'Medium Grade' galvanised, with all fittings and fixed to walls and ceiling or laid in floors.complete all as specified and directed by the Engr-In-Charge.
S&F for 20 mm Bore Steel Water Tubing 'Medium Grade' galvanised, with all fittings and fixed to walls and ceiling or laid in floors.complete all as specified and directed by the Engr-In-Charge.
Refixing old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrived from item No 31 above).
Refixing old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 20 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge (using old steel tubing retrived from item No 32 above).
M & L for Lagging to pipes 20mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh complete including taking down of old lagging if required all as specified and directed by Engineer-in-Charge
S&F aluminum handles, cast type anodized (size of handle 125mm) fixed with screw.
S&F in repairs aluminum handles, cast type anodized (size of handle 125mm) fixed with screw.
Supply & fixing 100mm long butt hinges mild steel medium weight cold rolled ISI marked.
Supply & fixing in repairs 100mm long butt hinges mild steel medium weight cold rolled ISI marked.
Supply & fixing 150mm long aluminum anodized barrel tower bolt of extrude section ISI marked fixed with screw
S&F in repairs150mm long aluminum anodized barrel tower bolt of extruded section ISI marked fixed with screw
S&F 300 mm long aluminum alloy, anodised sliding door bolts, with hasp, staple (bolt type and fixing clip of sheet, cast or extruded section or cast aluminium alloy and complete all as specified.
S&F in repairs 300 mm long aluminum alloy, anodised sliding door bolts, with hasp, staple (bolt type and fixing clip of sheet, cast or extruded section or cast aluminium alloy and complete all as specified.
S&F in repairs Wash Basin, vitreous china, white flat back, size 550x400mm excluding pillar taps, waste pipe, chain& plug incl brackets.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white complete all as specified.
S&F in repair 15 mm bore angle valve with wall flange fency type chromium plated, screwed down, high pressure with cruth or butterfly handle .
M&L in repair 15mm dia bib taps with wall flange and aerator chromium plated fency type with crutch or butter fly handle, screwed down screwed for iron pipe or brass ferrule and fixed
S&F in repair PVC low level flushing cistern 10Ltr capacity including float valve/handle bracket with PVC pipe complete all as specified.
S&F in repair 32mm dia PVC waste pipe with cap socket suitable for 32 mm waste coupling complete all as directed.
S&F in repair tubular towel rail ,20 mm dia, D type,60 cm long between flange complete all as spfd.
S&F in repair Towel rack size 600mm(24") complete all as spfd.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.`
S&F in repair powder coated Peg set of five of good quality approved by Engr in Charge.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including trap set complete all as specified and directed.
S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer all as specified and directed.
Material & labour for preparation of new plastered wall surfaces and applying two coats of Cement Base paint(Camouflage Paint) complete all as specified.
Hacking out old broken glass of any thickness/size and removing from site.
S&F 3mm thick sheet glass ordinary quality in square nexc 0.50 Sqm each pane fixed with wooden beads/oil putty in steel/wooden window.
S&F sheet glass 4mm thick, figured glass, pin headed type and glazing with oil putty or wooden beads supplied with shutters in square n.exc. 0.5 sqm in each pane.
S&F 5.5mm thick tinted glass cut to size for aluminium doors/window/partitions and mouldings where required open for working purpose incl rubber beading/Aluminium snap beading and complete all as specified and as directed.
Repair to aluminium shutter such as replacement of latch, glazing clip, hydrolic door stopper, oiling, cleaning rubber packing, alu beading to fix glass pan, complete all as specified and directed.(Note: floor door stopper and handle ,shall be paid seprately)
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty.
S&F in repair door closer aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
Taking down shutters of any description from the frames and refixing in the same opening after repair of door rescuring or easing & adjusting etc , area n.exc 2.00 sqm each complete all as specified
Repair,greasing and welding of hinges in steel window (size of each window exc. 1.00 sqm and not exc. 3.00 sqm) incl knob for handle/window stay if broken / missing handle / window stay shall be provided and fixed in window incl. one coat of synthetic enamel paint complete all as spfd.
M&L for Preparation of old painted steel surfaces of any description exc 10 cm width or girth and painting with one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wall surface and apply one coat of oil bound distemper incl scrubbing down old surface and filling of cracks, holes or damage portion etc with putty complete all as spfd.
M&L for preparation of old painted wall surface and apply two coats of oil bound distemper incl scrubbing down old surface and filling of cracks, holes or damage portion etc with putty complete all as spfd.
Dismantling boarding wall/ceiling any description fixed in any position with nails complete all as spfd.
M&L in repairs wooden panelling of second class softwood 12mm thick with tongue and groove joint fixed in any position over and including wooden framework in second class softwood with plain fillets square or rectangular in section clean sawn,secured with nails/screws of sectional area exc. 13 sqcm and nexc 25 sqcm at nexc. 90cm centre to centre in both direction and including three coats of french polishing on all the exposed surfaces complete all as specified and as directed by Engr-in-charge
S&F decorative designed false ceiling board of size 600x600mmx4mm thick with GI aluminium snap grid of 600x600 fixed over suspended false ceiling frames providing complete fitting/fixtures with GI ceiling angle 25x15x0.5mm thick or suitable channel with GI cleats if required fixed with screws mechanically either with screw driver or drilling machine with suitable attachment complete all as specified and directed by Engineer-in-charge.
Dismantling of AC/CGI/PVC sheet in roof covering of any size/shape.complete all as spfd.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified.
Fixing only Galvanised,corrugated mild steel sheeting in any position,fixed with coach/J-type screws and washers in roof,walls etc. complete all as specified.
M&L for tightening bolts and closing bolt holes etc. in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts, all set in stiff white lead, bolt n exc 25mm in length complete all as specified and directed by Engr-in-Charge.
M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed bedding layer of 10 mm thick in CM1:3 complete all as specified.
M&L Screed bed or bedding layer of mortar 15 mm thick cement mortar 1:4 for laying floor finishes complete all as specified
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
M & L for 25mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed.
S&F in repairs 75 mm bore dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified.
S&F in repairs 75 mm bore PVC(SWR) pipes single socketed,in any length with rubber ring joints,laid in trenches or in floors and fixed to wall with PVC holding clamps complete all as specifid and directed by Engr-in-Charge.
S&F in repairs 110 mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to wall or in floor incl PVC holding clamps complete all as specified.
S&F in repair rotational moulded polyethylene water storage tanks of 500 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including hoisting, connecting including dismantling existing tank and removing to store, all as specified.
M&L 75 mm thick PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors etc laid, bedded and pointed in any mortar, all as specified.
M&L coloured rubber moulded glossy finish Chequerred cement concrete tiles 30cm x 30cm x 25mm thick set and jointed in neat cement slurry with grey cement and pigment in floors complete all as specified.
M&L for 100mm thick cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base, complete all as specified.
M&L for sand cushioning for laying interlocking tiles, complete all as specified.
Material & Labour for machine pressed precast concrete interlocking paver block of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with white cement and pigment, conforming to IS 15658 laid in path / hardstanding complete Note:- Sand screed will be measured & paid seperatly.
Dewatering for cleaning of SWT of capacaty exc 15000 galon but n.exc 25,000 gallon, by dewatering from SWT, cleaning of entire internal surface with wirebrush remove all sludge and finaly cleaning with fresh water and appliying three coats of whitewash, writing date of cleaning with synthetic enamel paint complete all as directed by Engr-in-Charge.
Dewatering for cleaning of SWT of capacaty exc 25,000 galon but n.exc 50,000 gallon, by dewatering from SWT, cleaning of entire internal surface with wirebrush remove all sludge and finaly cleaning with fresh water and appliying three coats of whitewash, writing date of cleaning with synthetic enamel paint complete all as directed by Engr-in-Charge.
Dewatering for cleaning of SWT of capacaty exc 50,000 galon but n.exc 80,000 gallon, by dewatering from SWT, cleaning of entire internal surface with wirebrush remove all sludge and finaly cleaning with fresh water and appliying three coats of whitewash, writing date of cleaning with synthetic enamel paint complete all as directed by Engr-in-Charge.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for Preparation of old painted surfaces of walls and applying two coats of weather proof exterior emulsion paint, colour and tint as ordered, including sides and soffits of beams, fascias, parapets etc, complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion paint, over one coat primer colour and tint as ordered, including sides and soffits of beams, fascias, parapets etc, complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick PCC 1:2:4 type B2, using 40 mm graded stone aggregate as in floor laid in alternate bay finished even and smooth without using extra cement.
M&L for complete removal of existing treatment from internal surface static water tank and applying three coats of white wash complete old treatment in static water tank complete all as spfd.
S&F in repair tee hinges 150 mm size heavy duty welding to steel cover of any description complete.
M&L in repair Welded steel wire fabric of any size welded to steel frame work of static water tank complete all as specified & directed.
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
Supply and fixed in repair galvanised 2 strend steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of strails straining bolt including securing or tying at crossing with and provn of galvanised mild steel wire staple or steel pins etc complete all as specified as directed.
Dismantling chain link fencing fixed with steel or wood fillets, if any type complete all as specified
Supply only chain link fencing 4 mm dia galvanized steel wire aparure of size as directed, made up into mattresses or cages lapped wired conforming to IS 2721 all as specified & directed. Note:- Fixing only fencing will be measured and paid separately.
Fixing only chain link fencing of description fixed to steel post with mild steel flat & nut bolt etc. Note: (i) Supply only fencing, will be measured and paid separately. (ii) Supply and fix mild steel nut bolt, line wire and flat will be measured and paid separately.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Excavating in post holes, in soft/loose soil, (or similar holes) each n. exc. 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surfaces complete all as specified.
M&L for cement concrete type C-2 1:3:6 (40mm Grade aggregate) as in foundation, filling / sub base / bed of drain and mass concrete complete all as specified .
M&L mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
Demolition of cement concrete reinforced (reinforement cut as required to facilitate demolition) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing form site all as specified and directed.
M&L for RCC (nominal mix) Type B1 1:2:4 using 12.5mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs landings, balconies, canopies and in shelves and the like.
M&L for form work to soffits of flat, fair finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping)
M&L mild steel TMT bars 10mm dia and over cut to length bent to shape including cranking bending spirallay for hooping for columns hooking end and binding with and including mild steel wire (annelead) not less than 0.9mm dia or scuring with clips.
M&L PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in coping etc and the like including necessary form work if any complete all as specified and directed.
Removal of soft loos soil / sand etc from embankments height not exceeding 1.5 metre from Ground level complete all as specified & directed.
Removal of soft loose soil / sand etc from embankments height exceeding 1.5 metre but not exceeding 3.00 meter from Ground level complete all as specified & directed.
Loose filling of soft loose soil / sand in Firing range using soil removed vide item No 121 & 122 above including breaking of soil boulder in to small peice, height of filling not exceeding 1.5 metre above the ground level completed all as specified and diirected by Engineering-in Charge.
All as per Item No 123 above but height exceeding 1.5 metre but not exceeding 3.0 metre fromground level
M&L for Loose filling of clean and dry sand in Firing range, height of filling not exceeding 1.5 metre above the ground level completed all as specified and diirected by Engineering-in Charge.
M&L for Loose filling of clean and dry sand in Firing range, height of filling exceeding 1.5 metre but not exceeding 3.00 metre above the ground level completed all as specified and diirected by Engineering-in Charge.
Supply only dry river sand, stacking the same closely packed stacks on level ground in the location as directed by Engineer-in-Charge.
Supply only 20 mm graded stone aggregate, stacking the same closely packed stacks on level ground in the location as directed by Engineer-in-Charge.
Supply only 40 mm graded stone aggregate, stacking the same closely packed stacks on level ground in the location as directed by Engineer-in-Charge.
Supply only 63 mm graded stone aggregate, stacking the same closely packed stacks on level ground in the location as directed by Engineer-in-Charge.
Supply only 80 mm graded stone aggregate, stacking the same closely packed stacks on level ground in the location as directed by Engineer-in-Charge.
Note for Item No 127 to 131:- Measurment shall be carried out in bottomless boxes or measuring boxes or in closely packed stacks on level ground without any deduction for voids.
Taking down point wiring with aluminum conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator DB boxes with all fixtures service wire etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including pressed steel sunken box thickness not less than 1.8 mm with 3 mm thick laminated cover for mounting of piano / flush type switches, switch sockets, fan regulator etc, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate, complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
As per item No 133 above but One ceiling / exhaust fan point controlled by one switch and regulator complete all as specified and directed.
As per item No 133 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
As per item No 133 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per item No 133 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including pressed steel sunken box thickness not less than 1.8 mm with 3 mm thick laminated cover for mounting of piano / flush type switches, switch sockets, fan regulator etc, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate, complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
As per item No 138 above but One ceiling / exhaust fan point controlled by one switch and regulator complete all as specified and directed.
As per item No 138 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
As per item No 138 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per item No 138 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
As per item No 138 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed.
Material & Labour for concealed type point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for modular type switch with cover plate & frame, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
As per item No 144 above but one ceiling / exhaust fan point controlled by one switch and regulator complete all as specified and directed.
As per item No 144 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
As per item No 144 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per item No 144 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for concealed type point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25 mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for modular type switch with cover plate & frame, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
Balnk
As per item No 149 above but one ceiling / exhaust fan point controlled by one switch and regulator complete all as specified and directed.
As per item No 149 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
As per item No 149 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per item No 149 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F modular one way switch 6 Amp 240 volts suitable for one module complete all as specified and directed.
S&F modular one way switch 16 Amp 240 volts suitable for one module complete all as specified and directed.
S&F modular 6 Amp socket suitable for two module 240 volts complete all as specified and directed.
S&F modular 16 Amp socket suitable for two module 240 volts complete all as specified and directed.
S&F modular step type fan regulator suitable for 120 watt 250 volts complete all as specified and directed.
S&F piano type one way switch 6 Amp 240 volts suitable complete all as specified and directed.
S&F piano type one way switch 16 Amp 240 volts suitable complete all as specified and directed.
S&F piano type 6 Amp socket suitable for 240 volts complete all as specified and directed.
S&F piano type 16 Amp suitable for 240 volts complete all as specified and directed.
S&F piano type step type fan regulator suitable for 120 watt 250 volts complete all as specified and directed.
S&F in repair lamp holder / batten holder Polycarbonate type with back plate suitable for batten fitting including supply & fixing of 10 watt retrofit LED lamp.
S&F in repair ceiling rose with three terminal as per relevant IS complete all as specified and directed.
Supply only 10 watt LED lamp retro fit complete all as specified and directed.
Supply and fix in repair Energy efficient surface mounted 600 x 600 mm grid Ceiling LED fitting 36 / 40 W rated voltage 240 V, 50Hz combination with profiled and flat diffuse complete all as directed by the Engineer-in-Charge.
Supply and fix in repair LED baton fitting 600 mm length including drivers having energy consumption, 10 / 11 W (White/warm white), 230 V, 50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
Supply and fix in repair LED baton fitting 1200 mm length including drivers having energy consumption, 18 / 20W (White/warm white), 230 V, 50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
Supply & fix in repair light fitting 9 W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ complete all as specified and directed.
Supply & fix in repair fittings with surface mount LED down lighters 12 W including driver with rated voltage 240 V , 50 Hz, complete all as specified and directed.
Supply and fix in repair building security light LED 25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc complete all as specified and directed.
S&F in repair call bell ding dong type 230 Volts 50 Hz complete all as specified and directed by Engr-in-Charge
Supply and fix in repair sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral(VTPN) with MCCB 100 amps ICs=ICu,for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. .
Supply and fix in repair epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door) 8 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit complete all as specified andas directed by Engr-in-Charge.
Supply and fix in repair epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door) 12 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit complete all as specified andas directed by Engr-in-Charge.
S&F in repair MCB triple pole and neutral ISI marked C series working on 415 volts 50HZ AC supply for incoming and outgoing controlling system capacity 63 Amps 10 KA breaking capacity etc all as specified and directed.
S&F in repair MCCB three pole ISI marked working on 415 Volts 50Hz supply for incoming and outgoing controlling system of capacity 150 Amps all as specified and directe. Amps, 16 KA breaking capacity Ics=Icu etc all as specified and directed by Engr-in-Charge.
Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA breaking capacity, 'C' series complete all as specified and directed.
Supply and fix in repair MCB single pole and neutral 40 Amp 240 volt amps 10 KA breaking capacity, 'C' series, complete all as specified and directed.
Supply and fix in repair MCB single pole and neutral 63 Amp 240 volt amps 10 KA breaking capacity, 'C' series, complete all as specified and directed.
Supply and fix in repair metal clad plug & socket board SP&N enclosure with 2 pole and earth metal plug and socket complete 20 Amp MCB SP C curve, complete all as specified and directed.
Supply and fix in repair metal clad plug & socket board triple pole and neutral enclosure with 3 pin and earth plugs and socket complete with one triple pole MCB 32 Amps 415 Volts C type complete all as specified and directed.
M&L for submain wiring with three run of single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 6.0 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down and wiring complete. Note:- (i) 3 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purose.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 4.0 sqmm PVC insulated, unshea conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down and wiring complete. Note:- (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purose.
Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion
including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
M/S Thakur & Sons
M/S TARIQ AHMAD SHEIKH
M/S ZAHOOR ENTERPRISES
M/S M.R. Construction
M/S A.R.TANTARY
M/S GULAM AHMAD ABDUL SAMAD
M/S LUCKY BUILDERS
HAJI ZAHOOR HUSSAIN GANIE
M/S WANI AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .