| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹46.5 L+₹3.0 L (6.85%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L2 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 3 | L3₹47.0 L+₹3.5 L (7.97%)Rejected-Finance MONIRAMPUR DASPARA P O BARRACKPORE | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 743101 | L3 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 4 | L4₹48.6 L+₹5.1 L (11.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 5 | L5₹48.8 L+₹5.3 L (12.2%)Rejected-Finance VILL BONOGRAM PO RANDIA P S BUDBUD DIST BURDWAN PIN 713120 WB | BURDWAN | BURDWAN | WEST BENGAL | 713120 | L5 | Rejected-Finance HIGHER RATE QUOTED THAN L1 |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
30 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2024_MES_674640_1
8500-168/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per NIT
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹87,300
Yes
29 Nov 2024
14 Sept 2024
1 Oct 2024
14 Sept 2024
30 Sept 2024
24 Sept 2024
Amount
Excavation in trenches n.exc 1.5m deep and n.exc 10 Sqm on plan area and getting out in soft/ loose soil complete all as sepcified and directed.
Excavation in trenches exc 1.5m and n.exc 3m deep and n.exc 10 Sqm on plan area and getting out in soft/ loose soil complete all as specified and directed.
M&L for Hard core of broken stone or boulders of guage exc 63mm but n.exc 100mm, deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in fdn filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) in foundation footings bases for column, plinth beam etc complete all as specified and directed
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) as in columns complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) in beams, lintels over 1.5m span complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) (using 20mm graded stone aggregate) in chajjas complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, plinth beams and similar work vertical or batter for flat rough finished surfaces of concrete complete all as specified and as directed.
Form work to sides of pillars, posts, struts piers, columns and similar work square, rectangular or polygonal for flat rough finished surfaces of concrete complete all as specified and as directed.
Form work to sides and soffits of floor or roof beam, beam haunchings, girders, lintels, cantilevers shelves including supports, overhangs etc and similar work for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for TMT Bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 6mm to 8mm dia cut to length bent to shape required, including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking bending hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for brick work with fly ash bricks, straight or curved on plain exc 6m near radius, built in CM (1:6) complete all as specified and as directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement.
M&L for Rendering 20mm thick in two layers of 10mm thick on fair faces for brick work or concrete surfaces in CM (1:4) finished even and smooth without using extra cement. Second layer will be mixed with WPC@ 2% complete all as specified and as directed. Note: WPC will be paid separately as supply only.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces of wall including preparation of walls etc complete all as specified and as directed.
M&L for two coats on cement base paint over a coat of primer with alkali resistant priming paint on newly plastered surfaces of wall including preparation of walls etc complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on steel surfaces of any description over 10cm in width or girth, not otherwise described including preparation of surfaces complete all as specified and as directed.
M&L for mixing of fly ash, clinker & stone dust in proportion of 1:3:6 (i.e 10% Fly ash, 30% clinker and 60% stone dust materials) laying, watering ramming compaction complete all as specified and as directed.
M&L for reinforced cement concrete M-25 design mix (using 20mm graded stone aggregate) in foundation footings bases for column plinth beam floor ect complete all as specified and directed.
M&L for 150mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone agregate) in flooring complete all as specified and as directed.
M&L for hard core of broken stone or boulders of guage n. exc 63mm, deposited spread and levelled in layers n. exc15cm thickwatered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone agregate) in Plinth protection complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
S&F roof trusses (framed), trussed purlins crane gantries rails and fastenings and heavy bracket framing (beam, tee angle, channel or flat sections) including distance pieces cleats etc. Conforming to Fe-410 W (Gde-E-250) quality A complete all as specified and as directed.
S&F Pre-painted galvalumealuminium zinc coating GI based corrugated / semi corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an coloru having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n.exc 30cm long complete all as specified and as directed.
M&L for forming 12mm thick Expansion joints filled with pre-rormed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' for 100mm thick slab complete all as specified and as directed.
M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound, Grade 'B' for 100mm thick slab complete all as specified and as directed.
Excavation in trenches n.exc 1.5m deep and n exc 10 Sqm on plan area and getting out in hard/ dense soil complete all as specified and directed.
Dismantaling and demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
S&F for steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
S&F 3mm sheet glass ordinary quality and glazing with oil putty in squarn n exc 0.5 sqm in each pane complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n exc 30cm long complete all as specified and as directed.
Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
M&L for mixing of Fly ash, Clinker & Stone dust in proportion of 1:3:6 (i.e, 10% Fly ash, 30% Clinker and 60% Stone dust) laying, watering, ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97% placed at required camber and gradient complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate), in foundations, filling and mass concrete complete all as spcified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as spcified and directed.
M&L for rendering 15mm thick cement and sand mortar (1:4) on fair faces of brick work or concrete surface of wall, surface finished even and smooth without using extra cement complete all as spcified and directed.
M&L for PCC (1:2:4) Type B0 (using 12.50mm graded stone aggregate) used as in benching and coping complete all as spcified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level n exc 1.5m above the starting point complete all as spcified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm on soft/loose soil complete all as spcified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as weep holes complete all as spcified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as spcified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as spcified and directed.
E/M PORTION M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 50.00 above but 5 Amp socket on same board with other switches complete all as specified and directed.
S&F switch piano flush type, single pole, 5/6 Amps, one way complete complete all as specified and directed
S&F socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed
S&F submain wiring of two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed (Note: (i) Three runs cable and PVC conduit will be measured as a single unit. (ii) Quoted rate shall be included for necessary chasing, cutting and making good as per existing specification)
S&F security light fittings 35 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
S&F LED tube light fitting 1 x 20 watt box type with same make LED tube rod side connection AC decorative boxype 4' long wih driver, holder including LED tube connecting up with complete all accessories andconnection from ceiling rose with twin core twisted flexible copper conductor cable withsuitable size and earthing complete all as specified and directed. Make : Havells/CG/Bajaj/Jaquar
S&F as in repair epoxy powder coated sheet metal enclosure for DBs, single door, Single pole and neutral, 8 ways, with mounting fitted with 200 Amps rated bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. Make : ABB/Legrand/Hager/Schneider
S&F in repair MCB SP 10-32 Amps, 'C' series 10KA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. Make : ABB/Legrand/Hager/Schneider
S&F in repair MCB SPN 16-32 Amps, 'C' series 10KA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. Make : ABB/Legrand/Hager/Schneider
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
S&F XLPE insulated armoured cable, 25 sqmm 4 core,1100 volts grade heavy duty cable, ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed.
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling att as specified in SSR Part 2009 complete as specified and directed . Note :- Punned thickness 18 cm shall only be considered for payment
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified
NATIONAL CONSTRUCTION CO (BID ID -3120457)
M/S MODERN CONSTRUCTION (BID ID -3120974)
BISWAS ENTERPRISE (BID ID -3121035)
M/s S A TRADING (BID ID -3121116)
Goswami Enterprise (BID ID -3119919)
rahul enterprise (BID ID -3121144)
M/S DYNAMIC INDIA (PROJECT) CONSTRUCTION (BID ID -3121082)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .