Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC 245A 7A 1 JAYANTIPUR GOKUL AWAS YOJNA SULEM SARAI PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | ₹3.0 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹3.6 Cr+₹55.1 L (18.1%)Rejected-Finance | ₹3.6 Cr+₹55.1 L (18.1%) | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹3.8 Cr+₹73.8 L (24.2%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹3.8 Cr+₹73.8 L (24.2%) | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
| 4 | L4₹3.9 Cr+₹83.4 L (27.4%)Rejected-Finance | ₹3.9 Cr+₹83.4 L (27.4%) | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
| 5 | L5₹4.2 Cr+₹1.2 Cr (38.5%)Rejected-Finance | ₹4.2 Cr+₹1.2 Cr (38.5%) | L5 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹4.9 Cr
EMD Value
₹5.6 L
Closing Date
15 Jul 2020, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD
IMPROVEMENT TO CERTAIN SMQ AT AF STATION GORAKHPUR
2020_MES_348174_1
958983/E8
Open Tender
Civil Works
Item Rate
365 days
GE (AF) Gorakhpur
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Gorakhpur
₹5.6 L
Yes
31 Jul 2020
29 May 2020
20 Jul 2020
29 May 2020
15 Jul 2020
30 Jun 2020
4 Jun 2020 - 11 Jun 2020
Amount
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil for Path & hardstanding etc complete all as specified & directed.
Excavation in trenches in soft / loose soil n exc 1.5 Mtr wide and n.exc 1.5 m in depth for foundation, area drain & laying electric cable etc and getting out complete all as specified & directed.
Excavation in trenches in hard/dense soil n exc 1.5 Mtr wide and n.exc 1.5 m in depth for laying of DI/GI water pipe lines etc and getting out complete all as specified & directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point and deposited where directed complete all as specified .
Removing excavated material to a distance exc. 250 m but not exceeding 500 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point and deposited where directed complete all as specified .
Supply & laying sand for cushioning of cable in trenches for cable protection including spreading , levelling and hand punning complete all as specified and directed by Ebgr - in - charge. Note :- Thickness of snad cushioning shall be measured after punning and consolidating of sand.
Returning filling in including, spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and directed .
M&L for 25 mm thick P.C.C. (1:2:4) type B-0 ( using 20 mm graded stone aggregate) as in levelling course of floor complete all as specified & directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in roof kerb /benching in radius 10 cm with water proofing compound as per manufacturer's instructions etc complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slab for manhole and drain & setting in cement mortar 1:4 including necessary forwork etc complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in PCC blocks to fix the MS rings to approach roof ,manhole and other similar work etc complete all as specified and directed. (Note: Reinforcement & formwork shall be measured and paid separately under respective items)
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed. (Note: Reinforcement & formwork shall be measured and paid separately under respective items)
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as platform , floor etc complete all as specified and directed.
M & L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and smooth without using extra cement etc complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone agrregate as in foundation , filling , mass concrete or in sub base etc complete all as specified & directed.
M&L 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone agrregate for subbase of floor complete all as specified & directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggrgate) as in in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified & directed.
M & L for 40 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggragate) as in floor finishes even and smooth with using extra cement etc complete all as specified & directed.
M & L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggragate) with WPC as in padding to maintain proper slope as required etc complete all as specified & directed. (Note:- WPC shall be measured and paid separately).
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified & directed.
M&L for broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed.
M&L for form work to sides and soffit of floor and roof beams , cantilever ,shelves and similar work for rough finished flat surfaces of concrete etc complete all as specified and directed.
S&F glass dividing strips 38 mm wide and 3 mm thick inserted in position etc complete all as specifed & directed.
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) including builders hardware etc complete all as specified & directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) etc including builders hardware etc complete all as specified & directed .
Taking down shutters of any description not exceeding 1 Sqm each etc complete all as specified & directed.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each etc complete all as specified & directed.
S & F Second class, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed .
S&F 2nd class HW , Plain fillets, square or rectangular in section, clean sawn, secured with nails or brads with sectional area exc 3 & nexc 6 sqcm in repairs etc complete all as specified and directed.
S&F for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete all as specified and directed.
S&F second class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc complete all as specified and directed.
S&F factory made 2nd class hardwood panelled shutter 35mm thick (any number of panel) with panels of timber flat on both sides (feather edges) or of veneered particle board meidum density , wood particle board with commercial face veeners of plywood commercial type etc complete all as specified and directed.
S&F 18 to 19 mm thick particle board medium density ,flat or pressed single layer type or three layer type with BWR type adhesive fixed with screws to timber frame work or in shutters etc complete all as specified and directed.
S & F Solid PVC door frame of size 50mmx 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, as per manufacturers specification complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent complete all as specified and directed.
Taking down shutters of any description exc. 1.0 Sqm and not exc 2.0 Sqm each and refixing in same opening including necessary minor repair & adjustment of shutter etc complete all as specified & directed.
Resecuring or erasing and adjusting ,withot taking down shutters exc 1 sqm but not exc 2 sqm in any type of door etc complete all as apecified and directed.
S&F 100 mm size MS medium weight butt hinge cold rolled complete all as specified & as directed.
S&F mild steel 300 mm , ordinary rat tail rod pattern springs including roller and roller plate welding etc complete all as specified & directed.
S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring with overall length of cover plate 150 mm long complete all specified and directed.
S&F 75 mm long butt hinges , anodised , extruded aluminium alloy with galvanised mild steel hinged pin , type C-21 etc complete all as specified & directed.
S&F extruded aluminium alloy handle 100 mm long fabricated type complete all as specified & directed.
S&F extruded aluminium alloy handle 150 mm long fabricated type complete all as specified & directed.
S&F barrel tower bolt 150 mm long ,anodised, extruded aluminium section complete all as specified & directed.
S&F 75 mm size MS medium weight butt hinge cold rolled complete all as specified & directed.
S&F in 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections etc complete all as specified & directed.
S&F hasp & staple of size 100mm safety type , anodised aluminium alloy, including bolt to hinge plate and fixed with screws in repairs etc complete all as specified & directed.
S&F galvanised mild steel wire cloth, 0.56 mm nominal diameter of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanised wire staples complete all specified and directed .
S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal diameter of wire and average width of aperture 1.18 mm fixed with tinned tacks or galvanised wire staples complete all specified and directed .
M&L powder coated anodised aluminium (sliding/hanging type)windows with three track , bottom track size 92X29.5X2 mm thick , side and top track frame size 92X29.5X2 mm thick and shutter aluminium anodised 39x20x2 mm thick including necessary aluminium fittings like jointing cleats , glazing cleats, rubber packing , anodised aluminium snap beading , screws etc with 5 mm thick tinted /plain glass panels or wire mesh with stainless steel wire cloth of 0.36 mm nominal dia and average width of aperture 1.18 mm incl all fittings and fixtures etc complete all as specified and directed.
M&L powder coated anodised aluminium (sliding/hanging type) ventilator with three track , bottom track size 92X29.5X2 mm thick , side and top track frame size 92X29.5X2 mm thick and shutter aluminium anodised 39x20x2 mm thick including necessary aluminium fittings like jointing cleats , glazing cleats, rubber packing , anodised aluminium snap beading , screws etc with 5 mm thick tinted /plain glass panels or wire mesh with stainless steel wire cloth of 0.36 mm nominal dia and average width of aperture 1.18 mm incl all fittings and fixtures etc complete all as specified and directed.
M&L for mild steel framed work such as grills, grating etc with ends of bars shouldered and or reveted into spikes, framed guard bars, , barred iron doors, ladders, framed balusters, walk ways, railing, cooler platform, frame work of water tanks and similar work including welding conforming to Fe-290 & grade E-165 etc complete all specified and directed.
S&F TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
All as per Srl item No. 1.53 but 6 mm to 8 mm dia bars.
S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples and weight exc 4kg/sqm etc complete all as specified and directed.
Supply and fixing mild steel round bars 10 mm dia and over , cut to length ,bent to shape as in MS rings complete all as specified & as directed.
M&L for 10 mm thick screed bed in CM 1:4 complete mixed with liquid water proofing compound as per manufacturers instructions over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over extsting acessible RCC roof slab /chajja/canopy/ parapet wall to be executed through approved applicator of the membrane manufacturer as per specifications mentioned in PS clause 16.3.2 and 16.4.1 etc complete all as specified and directed. NOTE ( Water proofing compound shall be measured and paid seperately under respective item).
M&L for glazed ceramic coloured tiles of size 450X350mm/350X250mm thickness not less than 7 mm as in skirting / dado etc set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles including 10 mm thick backing coat in CM (1:4) etc complete all as specified & directed.
M&L for 40 mm thick brick tile laid over screed bed in cement mortar 1:4 , jointed and pointed in CM 1:3 mixed with crude oil @ 5 % by weight of cement etc complete all as specified & directed.
All as srl No. 1.60 Above but except tiles etc complete all as specified & directed.
M&L for non skid coloured ceramic floor tiles not less than 7-8 mm thick (Square/rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including 15 mm thick screed bed in CM(1:6) etc complete all as specified & directed.
M&L for non skid coloured ceramic floor tiles not less than 7-8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including 15 mm thick screed bed in CM(1:6) etc complete all as specified & directed.
M&L for polished Varoda green Marble in steps,pillars,cooking platform, window cill & jambs 18 to 20 mm thick set & jointed in neat cement slurry & pointed in white cement (1:2) using marble dust with admixtures of pigment to match with shade of granite & including 10 mm thick screed bed/ backing coat in CM(1:4) etc complete all as specified & directed.
M&L for 60mm thick factory made rubberised coloured (laminated) interlocking paver block (using vibro compaction method) (topping thickness not less than 5mm) in white cement and non fadable glossy pigment of approved shade of any shape and size conforming to IS-15658-2006 of M-35 grade laid over complete all as specified and directed.
M&L for 30 mm thick sand cushioning under floor or in foundation including watering and consolidation complete all as specified and directed.
Taking down cement plaster of brick or stone masonry, wall surface & RCC ceiling etc including raking out joints hacking for key & scrubbing down with water and removal of rubbish / mortar out off the premises / MD land etc complete all as specified & directed.
M&L for rendering 15 mm thick in CM(1:6) on faces of brick work or concrete surfaces , finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 15 mm thick in CM(1:4) on faces of brick work or concrete surfaces , finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 15 mm thick over PCC bedding with water proofing compound etc in CM (1:4) surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for chamfers ,splays or arris of granite in face work exc. 15mm but n. exc 50 mm wide complete all as specified and directed.
M&L for rendering 5 mm thick in CM (1:3) on brick work or concrete surface as in ceiling , finished even and smooth without using extra cement complete all as specified & directed.
Supply only polymer liquid water proofing compound of approved make all as specified & directed.
Supply only water proofing compound of approved make all as specified & directed.
M&L for preparation of newely plastered surfaces of ceiling and applying two coat of white wash on ceiling complete all as specified & directed.
M&L for preparation of existing white washed surface of ceiling and applying one coats of white wash on ceiling complete etc all as specified & directed.
M&L for prepartion of existing painted steel surfaces of any description over 10cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L for prepartion of new or previously untreated steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for prepartion of existing painted wooden surface of any description not otherwise described, over 10cm in width or girth and applying one coats of synthetic enamel paint (ordinary tint )complete all as specified & directed.
M&L for prepartion of new or previously untreated wooden surface of any description , not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
M&L for preparation of newly plastered surface wall and applying two coats of cement base paint over a coat of alkali primer including necessary scaffolding complete all as specified & as directed.
M&L for preparation of old plastered surface wall and applying one coats of cement base paint including necessary scaffolding complete all as specified & as directed.
M&L for complete removal of existing treatment of wall with rotary scrapper / sand cutting machine to achieve paint/ periodicals free even & smooth finished plastered surface and applying two coats of distemper oil emulsion (OBD) with roller finish over a coat of cement wall primer (from same manufacturer of OBD) over & including a layer of wall care putty not less than 1mm thick etc complete all as specified and directed.
Preparation of newly plastered surfaces of wall and apply two coats of distemper oil emulsion (OBD) with roller finish over a coat of cement wall primer (from same manufacturer of OBD) over and including a layer of wall care putty not less than 1mm thick etc complete all as specified and directed.
S&F kitchen sinks with draining board made of stainless steel 1 mm thick with plugs, washers & waste coupling and waste pipe, including bedding in cement mortar 1:2 on dwarf wall or including fixing cantilever brackets and connecting union to waste pipe and coupling , overall size 915 mm X 460 mm and bowl size size 410 mm X 330 mm X 160 mm complete all as specified and directed.
S&F 75 mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) etc complete all as specified & directed.
S&F 75 mm bore cast iron soil / waste and vent pipes in any length with or without ears with cement joint fixed to wall/floor complete all as specified & directed.
S&F cast iron 75 mm bore bends (any radius ) , diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
S&F SWR bends 75 mm bore provided with access door (any radius ) complete all as specified and as directed.
S&F PVC(SWR) branch piece 100/110mm bore double (double Y) equal or unequal and with access door complete all as specified and directed.
S&F 100/110mm bore SWR junction single ,(single T) equal or unequal and with access door complete all as specified and directed.
S&F 75 mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 (using 20 mm stone aggregate) complete all as specified & directed.
S&F stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to walls or roofs for 75 mm bore pipe etc complete all as specified and directed.
S&F in repairs Vitreous china WC squatting pan " Orissa Pattern" of size 580 X 440 mm white with integral foot rest(excluding flushing cistern and flushing pipe) including cast iron P or S trap, front or back inlet and making connection to trap & to flushing cistern and making good to the floor complete all as specifed & directed.
S&F in repairs Vitreous china WC pan " Padestal Pattern" (excluding flushing cistern and flushing pipe) including fixing Palstic water closet seat, black/white,closed pattern with flat bottem, and cover and mild steel chromium plated or aluminised hinging device complete all as specifed & directed.
S&F in repairs PVC flushing cistern, ISI approved, 10 ltr capacity valve less syphonic action type low level, white , with inlet , ball valve, float and handle including brackets complete with flush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed.
S&F 1 mm thick stainless steel utensil rack of size 600X900 mm and fixing to wall with screws complete set all as specified and directed.
S&F in repair Viterous china white wash basin , flat back of size 550X400 mm including cutting for and pinning in ends of brackets or erecting stand and excluding taps , plugs & porcelain stopper but including bracket complete set all as specified and directed.
S&F soap dish (Oval type) of size 100X50X10 mm , Chromium plated mild steel and fixed to plugs with chromium plated brass screws complete all as specified & directed.
S&F in repairs angle cock, cast copper alloy, chromium plated fancy type of size 15 mm bore complete all as specified & directed.
S&F in repair bib taps, cast copper alloy with crutch or butterfly handle , CP fancy type , screwed down with high pressure screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified & directed.
S&F in repair pillar taps fancy type, cast copper alloy, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed.
S&F in repair brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe or union complete all as specifed & directed.
S&F of Tubular towel rail brass chromium plated, 20mm dia, D type, 600mm long between flanges complete all as specified and directed.
S&F curtain rod/rail with drapery rod plastic coating fancy type 25 mm dia including brackets etc complete all as specified and directed.
Taking down rainwater/vent pipe (any size or pattern), including all fittings and also removal to store complete all as speciifed and directed.
Taking up or down steel tubing and connections 15 mm bore, open or concealed complete all as specifed & directed.
Taking up or down steel tubing and connections 20 mm bore, open or concealed complete all as specifed & directed.
S&F GI water tubing medium grade, ISI marked, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors complete all as specified and directed.
M&L for fixing of 32 mm dia medium grade GI tubing as in spout pipe in sunken slab including cutting hole throughout in brick or concrete wall and matching the disturbed surface in CM (1:3) complete all as specified and directed.
Supply & fixing in replacement light grade GI pipe bend to shape 1.5 mtr (32/40 mm dia as required at site) with two nos clamps made out of 50x6mm flat and two Nos bolts & washer with nuts duly grouted in wall or fixing on pole all as directed.
Supply and fixing GI tubing 40 mm bore , light grade , on poles , under floor, road crossing and wall etc complete all as specified and directed.
Refixing existing serviceable steel tubing and connections 15 mm bore, in same or different position (walls, ceiling, floors, etc) including additional fitting complete all as specified & directed.
Refixing existing serviceable steel tubing and connections 20 mm bore, in same or different position (walls, ceiling, floors, etc) including additional fittings complete all as specified & directed.
S&F PVC (SWR) pipes 100/110 mm bore single socketed, in any length with rubber ring joints, laid in floors or fixed to wall complete all as specified & directed.
S&F PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in floors or fixed to wall complete all as specified & directed.
S&F PVC (SWR) bends for 100/110mm bore , of any radius, provided without access door complete all as specified & directed.
S&F PVC (SWR) bends for 75mm bore , of any radius, provided without access door complete all as specified & directed.
S&F PVC Connection 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed.
Taking down existing water tank of capacity exceeding 250 Litre and n.exc. 500 litre from roof slab ( Inclding lowering if required ) by disconnecting water lines/connection complete all as specified & directed.
S&F rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI medium grade over flow ( 450mm long) and washout pipe (600 mm long )with fittings etc complete all as specified and directed.
Taking down existing water tank of capacity exceeding 250 Litre and n.exc. 500 litre from roof slab ( Inclding lowering if required ) by disconnecting water lines/connection & setting aside cleaning and removing all scale & dirt from inner surface of tank & mouth of circulating pipe including resetting & reconnecting etc complete all as specified & directed.
S&F 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified & as directed.
S&F in repairs Stop valves fancy type of 15mm bore, cast copper alloy,chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs gun-metal stop cock 20mm bore ,globe or gate valve , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F gun-metal globe or gate valve ,20mm dia , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 75 mm dia outlet PVC(SWR) floor trap , plain with grating including jointing with solvent cement complete all as specified & directed.
S&F 75 mm dia outlet PVC(SWR) multi floor trap , plain with grating including jointing with solvent cement complete all as specified & directed.
Demolition of plain cement concrete (unreinforced) of any mix / grade of ground floor and paving not exceeding 15cm thickness (below or above ground level) including removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
Demolition of plain cement concrete (unreinforced) of any mix / grade and in any position not otherwise specifically provided etc complete all as specified & directed .
Demolition of Mud/cement concrete in roofs, any thickness, including plastering and leeping including cleaning surface of roof with wire brush/ mechanical brush thoroughly to remove old dirt / loose particle to exose clean surface concrete slan and then cleaning down with water etc complete all as specified and directed .
Demolition of floor, tile / slab & wall tile of any type / pattern including cement mortar bedding / backing and removal of debris out off the AF station premises / MOD land etc complete all as specified & directed .
Demolition of reinforced cement concrete in roof, floor beam, staircase, landing, chajja and similar suspended works complete (reinforcement cut as required to facilitate demolition) including removal of debris out off the premises / MOD land complete all as specified & directed.
Dismantling of brickwork of any description and in any position built in cement or cement lime mortar including all coin, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off the AF station premises / MOD land etc complete all as specified and directed.
Dismantling of brick tiles or tarring tiles single layer bedded in cement mortar on roofs complete all as specified & directed.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
Cutting chases in brick walls not exceeding 10 cm grith, pinning in , making good to facings where required and pointing in cement mortar (1:3) for concealed water tubings complete all as specified and directed.
Cutting holes in brick wall built in cement mortar or cement lime mortar and stone walls built in lime mortar for holdfast or inserting rings or staging or roofs complete all as specified and directed.
Cutting existing steel tubing of dia 20 mm for alterations or additions (Each cut measured) and done in position without taking down etc complete all as specified and directed.
Taking down carefully unsv/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring of any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing/segregating carefully serviceable fittings/ fixture for reuse under respective items including making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
M & L for point wiring with FRLS PVC insulated PVC unsheathed electric cable confirming to IS.694,1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area for phase & neutral in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated copper conductor as a earth wire connected to earth dolly by providing lugs including galvanized boxes with laminated sheet cover ISI marked, sheet 3.0 mm thick complete for mounting switches, sockets, fan regulators etc for the following:- (a) One light / ceiling fan / exhaust fan point controlled by one switch etc complete all as specified and directed.
All as per Srl item No. 2.42 but One call bell point controlled by bell push etc complete all as specified and directed.
All as per Srl item No. 2.42 above but One 3 pin socket outlet, on the same board soket 5 Amps point, with other switches with other switches with cable 1.5 Sqmm etc complete all as specified and directed.
All as per Srl item No. 2.42 above but One 3 pin socket outlet, for independent socket 5 Amps point etc complete all as specified and directed.
All as per Srl item No. 2.42 above but One light point controlled by two way two switches etc complete all as specified and directed.
All as per Srl item No. 2.42 above but complete with 1100 volt grade FRLS PVC insulated unsheathed multi stranded wire with 2.5 sqmm copper cable through and including concealed PVC conduit medium grade of size not less than 20 mm dia etc fixed in wall / ceiling of suitable size and one run of 2.5 Sqmm copper cable of green colour connected to earth dolly earthling of 15 Amps socket outlet independent etc complete all as specified and directed.
S&F switch piano, flush type, single pole, two way 5 amps 230 volt AC ISI marked complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 5 amps 230 volt AC ISI marked complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 15 amps 230 volt AC ISI marked complete all as specified and directed.
S & F modular PVC enclouser with plug and socket with a two pin and earth plug & socket , 240V , AC complete with one single pole MCB of capacity 20 Amps complete all as specified and directed by Engr-in-charge.
S&F socket outlet, three pin, 5 Amps flush type, 230 volts AC ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin , 5 and 15 Amps 230 volts AC circuit ISI marked complete all as specified and directed.
S&F ceiling rose polycorbonate, three terminals complete all as specified and directed by Engr-in-charge.
S&F bell push, flush type, 5 Amp, Single pole, one way, 230 volts AC circuit complete all as specified and directed.
S&F bell (Ding dong), 230 volts AC circuit single pole complete all as specified and directed.
S/F for lamp holder, polycarbonate type with back plate suitable for batten fittings conforming to ISI marked including LED lamp 9 watt b-22 base, 230V AC complete all as specified and directed.
Disconnecting & taking down old unserviceable existing submain wiring Aluminium/Copper of any size including earth continuity conductor on teak wood or conduit and removing from site and making good disturbed surface of wall etc complete all as specified and directed.
M&L for Submain wiring using two runs of single core FRLS PVC insulated ,unsheathed stranded copper conductor cable of size 2 runs of 6 sqmm of voltage rating 1100 V for single phase & neutral ,drawn in and including concealed PVC conduit of dia not less than 20 mm with standard acessories , alongwith one run of FRLS PVC insulated , unseathed , stranded copper conductor of size 1x6 sqmm as earth continuity conductor al as specified and directed . (NOTE: 2 runs of single core FRLS PVC cable 6 sqmm for phase & neutral with one run of earth conductor as earth and conduit shall be measured as one unit.)
Taking down old U/S existing DB TPN 4 way and DB SPN & way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Supply and fixing in replacement of tamper proof energy meter electronic type single phase 10-40 Amps current rating single phase 230V AC with optical port duly scaled in place of unserviceable energy meter including electric connection with single core multi stranded copper conductor cable with flexible conduit of proper size Note : (a) The meter will be fixed on wooden board of suitable size. (b) Old unserviceable electric meters to be removed and deposited in MES store yard.
S& F factory made epoxy powder coated distribution board TPN 4 ways 415 Volt grade (TPN MCB DB ) with double door and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar ,neutral bar ,strande DIN rail ,Earth bar and cable ties for cable management ,top and bottom removable gland plates with knockouts complete all as specified and directed
S&F ‘B’ series 32-40 Amps double pole MCB complete all as specified and directed make INDOASIAN HSN Code-8536/C&S product code No CSMBS2B40 / STANDARD Cat No DSMGCDPF040
S&F MCB TPN ‘B’ / ‘C’ series 40 Amps, 415 volts, 50 Hz, 10 KA complete all as specified and directed Make-INDOASIAN-Cat No 811218 / C&S Product Code No CSMBS3B40N / STANDARD Cat No DSMGTNG040.
S&F MCB ‘C’ series SP 06 to 32 Amps, 230 volts, 50 Hz, breaking capacity 10 KA complete all as specified and directed Make-INDOASIAN-Cat No 811008 to 811015 / C&S Product Code No CSMBSIB6-32 / STANDARD Cat No DSMGBF006-032
Supply and fixing 35 to 40 Watt LED street light made up of pressure dia cast aluminum housing with high power LED as lighting source and lens embedded polycarbonate cover having driver compartment with IP66/IP65 protection connecting the same to electric source with using copper conductor 23/0.0076 PVC insulated flexible three core cable complete all as specified and directed .Make Wipro Cat Part No- LR02-451-XXX-57-G1/Bajaj Cat Part No- BRTFG-36LEDV2I /Havells Cat Part No- ENDURAPEARLNEOSL40WLED757PASYTOPC
S & F wall / surface mounted type LED light fitting for mirror light complete with LED lamp of 1x10/9 watt extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver complete with accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.Make Philips cat part No BN021LEDIOS-6500 PSU GR SI OR Wirpro Cat Part No LL20-111-XXX-65NE3/Havells Cat part No ENDVRA LINEAR NEO BS 10W LED 830 SPC WH.
S & Fixing wall / surface mounted type LED light fitting complete with LED lamp of 1x20 watt / 1x24watt ( 4Ft), extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make Crompton Cat Part No -LCCLB24-CDL/Havells cat part No- ENDURALINERNEOBS20WLED865SPCWH/ Wipro cat Pat No- LL20-221-XXX-65ALI.
S&F fan regulator electronic socket type , 5 step controlled 230 volts AC 50 HZ supply etc complete all as specified & directed
S&F water heater storage type electric (Geyser) capacity 25 liter and 1500 Watts copper tank 5 Star rating automatic cutoff including electric connection lead of suitable size length of lead up to 1 mtr and HOT & COLD PVC pipe water connection all accessories complete all as specified and directed. Make Bajaj/Havells/Cromption.
Removing and keeping oxide for re-use and refixing water heater storage type puff insulation type of 25 ltrs capacity and 1500 watts with Hot & Cold pipe, existing water connection pipe, electric connection and necessary fixing arrangement complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side in store in safe custody for painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site complete all as specified and directed.
Taking down Exhaust fan, sealing cable end, dismantling blades and removing fan and blades & refixing exhaust fan any make, any sweep, keeping side in store in safe custody fore painting of exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust and resembling the fan complete including writing MES No at the site complete all as specified and directed.
Supply and fixing exhaust fan of 300 mm sweep metal body singly phase 230 V AC, including mounting frame, nut, bolts, washers, fasteners etc and connecting exhaust fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 mtr long for connection complete all as specified Make : Bajaj/Plaza/Cromption/Orient.
Supply and fix air circulator fan AC single phase 230 volt 50 Hz of size 230 mm sweep pvc body with louvers and connecting the same to electric source with using copper conductor 23/0.0076 PVC insulated flexible three core cable complete including writing MES No at the site all as specified and directed Make: Bajaj/ Plaza/Cromption/Orient/Havells.
M&L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with 6mm dia M.S. round bar placed 75mm C/C and handle of 10mm dia and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
Supply and laying , connecting and testing of LT cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty) 1100 volts grade ISI marked with aluminium stranded conductor of 16 Sqmm , 4 core including taking down existing LT cable of any type & any size complete all as specified and directed.
Taking out XLPE insulated armoured heavy duty electric cable 1100 volt grade with aluminium conductor of cross section area 10 sqmm 4 core complete all as specified and directed.
Supply and laying bricks, old size , sub class 'B' laid over sand cushioning as cable protection in trenches keeping width of brick parallel to the edge of cable complete all as specified & directed.
Supply and Laying 20 mm bore medium grade ISI marked G.I. tubing laid in trenches or fixed on wall with screwed and socket joints together including fixing with MS clamp , nut, bolts , elbows, tees, union, connector, caps and plugs etc complete & including disconnecting and taking down of old corroded GI pipe all as specified & as directed.
Supply and fixing in replacement light grade GI pipe bend to shape 1.5 mtr (32/40 mm dia as required at site ) with two Nos clamps made out of 50X6 mm flat and two Nos bolts & washer with nuts duly grouted in wall or fixing on pole all as specified and directed.
Supply and fixing factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic cover (IP-43 protection) including 200 amps copper bus bar , neutral bar , standard DIN rail , earth bar and cable ties fan cable management , top and bottom removable gland plate with 06 SP MCB as outgoing complete all as specified and directed .
Taking down unserviceable GI tube 20 mm dia from wall/trench/ceiling complete all as specified and directed.
M/s Raj Traders
imran construction company
M/S Rajeev Kumar
M/S P.S Mishra
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .