Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹18.9 L+₹5.2 L (38.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹19.0 L+₹5.3 L (38.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹21.0 L+₹7.3 L (53.7%)Rejected-Finance 60 310A 3 KHERIA MOD JAGNER ROAD AGRA 01 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.4 L+₹11.8 L (86.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Jun 2022, 6:00 pmClosed
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
REPAIR MAINTENANCE OF PH 509 ABW 411 FD COY ODF MAP OFFRS QTRS KB LINE PUMP HOUSE OLD BP LINE AND NEW BP LINE MAP PH II ODF RO PLANT 509 ABW MP LINE PH 801 TA BN RO PLANT AND AMAR SINGH CAMP UNDER AGE E M W OF GE W AGRA
2022_MES_523969_1
8012/894/E8
Open Tender
Civil Works
Item Rate
330 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹50,000
14 Jul 2022
13 May 2022
13 Jun 2022
13 May 2022
11 Jun 2022
27 May 2022
Amount
Repair/maintenance and servicing of RO plant, 1000 Ltrs capacity in undermentioned locations by replacement of unserviceable parts to make it serviceable including cleaning of membrane active, carbon filters sand, silex media property if required with the help of changing chemical (recommeded by manufacturers) complete all as directed by Engineer-in-Charge. Note : (i) No extra payment will be made for chemical and other cleaning material. Location of Plant: (i) ODF (ii) 509 ABW (iii) Red fort.
S&F in replacement of cartridge 4" x 20" large filter 5 micron thread type. Make – Pentair/Genpure/Aqua/Kamflow
S&F in replacement of cartridge 2" x 20" large filter 1 micron paper/spun type. Make – Pentair/Genpure/Filtermation
S&F in replacement of activated carbon for Reverse Osmosis (RO) plant capacity 1000 Ltrs complete all as specified and directed.
S&F in replacement of sand media for RO plant cap 1000 Ltrs complete all as specified and direcetd.
S&F in replacement of Silex Media for Reverse Osmosis (RO) plant capacity 1000 Ltrs complete all as specified and directed
S&F in replacement of antiscalant chemcal / Solution for Reverse Osmosis (RO) plant capacity 1000 Ltrs complete all as specified and directed
S&F in replacement of membrane, suitable for RO Plant of capacity 1000 LPH, low energy/brikish type BW 30-4040. Make : DOW/FLIMTECH/Hydronotics
M&L for dismantling high pressure motor of capacity up to 2HP & cutting the unserviceable winding wire, cleaning the stator and totor and rewinding the same with supper enameled copper winding wire of existing gauge and turn including varnishing, PVC sleeve, cotton tape insulation paper and all other material required for rewinding including lathe work of shaft and replacement of defective bearings two Nos (6203/6205 of make NBC/SKF) and refixing back in original position complete all as specified and directed.
M&L for dismantling high pressure pump up to 3HP, multistage, centrifugal/monoblock electric driven, reassembling and refixing in position after repair by replacemnet of impeller, gasket, gun metal bush, water seal etc complete to bring it in serviceable condition complete all as specofoed and directed.
S&F in replacement of flushing pump of of capacity 0.8 HP stainless steel body complete all as specified and directed . Make: Kirloskar/CRI
S&F replacement of pressure gauge 2'' dia of cap 0-20 kg/sqcm or 300 psi including necessary connection complete all as specified and directed by Engr-in-Charge.
S&F in repairs gun metal half turn valve 25mm bore for iron pipe complete all as specified and directed
S&F in repairs gun metal half turn valve 20mm bore for iron pipe complete all as specified and directed.
S&F in repair single phase preventor type VSP 2 complete all as specified and directed. Make MINILEC or equivalent
S&F in repair starting panel with single phase starter 230 Volts, over load relay, Amp meter , Volt meter, Contractor including 32 Amp SPN MCB indicating lamp push button etc suitable for 2 to 3 HP submersible pump complete all as specified and directed. Make Havells/Bentex/L&T
S&F in replacement of membrane housing made out of Stainless Steel for 1000 LPH RO plant suitable to hold of 2 memberane in series low energy type of size BW 30-4040 complete with end shield, nuts, bolts complete all as specified and directed.
S&F in replacement of chemical dosing pomp suitable for 1000 LPH RO plant complete all as specified and directed.
S&F in repairs TDS meter to monitor on line reading of final treated water with digital display panel mounted complete all as specified and directed. Make : Aquatek/ Flowstar/ Aster/Fivbro or equivalent.
S&F in repair pressure gauge, 100mm dia of scale 0 to 7Kg/cm2 with FI clamp of size 25 x 3 mm and 15mm socket complete all as specified and directed.
S&F in repair over load relay including fixing arrangment suitable for 2/3 HP submersible pump complete all as specified and directed.
S&F in repair contactor including fixing arrangment suitable fpr 2/3 HP submersible pump complete al as specified and directed.
S&F in repair capacitor including fixing arrangment suitable for 2 HP submersible pump complete al as specified and directed.
S&F in repairs submersible cable PVC insulated copper conductor 2.5 Sqmm 3 Core 1100 V grade complete all as specified and directed. Make : Havells, Finolex, Polycab or Equivelent.
S&F in repairs submersible cable PVC insulated copper conductor 4 Sqmm 3 Core 1100 V grade complete all as specified and directed. Make : Havells, Finolex, Polycab or Equivelent.
S&F in repairs submersible cable PVC insulated copper conductor 6 Sqmm 3 Core 1100 V grade complete all as specified and directed. Make : Havells, Finolex, Polycab or Equivelent.
Excavation in trenches in soft/loose soil, n. exc. 1.5 M wide and n.exc 1.5 M in depth, to required level and gradient for laying of pipe etc and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed.
Removing excavated materials (soft/loose soil) to a distance n.exc. 50 M and depositing where directed at a level n.exc. 1.5 M above the starting point complete all as specified and directed.
Dismantling and taking out old unsv CI/DI pipe line of 150 mm dia from excavated trenches complete all as specified and directed.
Supply, laying and jointing for 150 mm bore centrifugally cast (spun) ductile iron pressure pipes for water mains with socket & spigot ends conforming to IS 8329/2000 any length for classification of K7 suitable for rubber gasket joint (push on type) with cement mortar lining inside the pipe with outside zinc coating complete all including existing connection with required size of Tee or MS clamp with rubber bush as specified and directed.
Cutting existing Cast Iron/Ductile iron pipes in position (comprising of two cuts) for insertion of new iron fittings (tees, branches etc) complete of the size 150mm bore of pipe.
M&L for push on tyton (rubber gasket) joints for 150mm bore DI pipe complete all as specified and directed.
S&F in repair MCCB, 3 pole, 415 volts, 50 Hz, 63-100 Amps, 16 KA fixed type complete all as specified and directed. Make : L&T/Legrand/Havells
S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA , complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA , complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA, complete all as specified and directed.
S&F in repair cast iron non return valve 80mm bore ISI marked both ends flanged including rubber gasket, MS bolts, nuts, washers and testing complete all as specified and directed.
S & F in repairs cast iron sluice valve for the 150 mm bore both ends flanged, PN-1.0, with iron wheel (ISI marked) steel spindle,including nuts, bolts, washers and 3 mm thick rubber insertion sheet complete all as specified and directed.
S&F in repair sluice valve, Class PN-1, 100 mm dia both end flanged with high tensile SS spindle with lock nut (gutka), ISI marked complete with jointing materials such as rubber packing, nuts, bolts & washers complete all as specified & directed.
S&F in repair sluice valve, Class PN-1, 80 mm dia both end flanged with high tensile SS spindle with lock nut (gutka), ISI marked complete with jointing materials such as rubber packing, nuts, bolts & washers complete all as specified & directed.
Repairs to leakage of 300 mm dia bore pipe, fittings, such as tee, bends, tail pieces, connecting pieces etc including making new run lead joints by using spun yarn and earth works complete all as specified and directed.
Repairs to leakage of 250 mm dia bore pipe, fittings, such as tee, bends, tail pieces, connecting pieces etc including making new run lead joints by using spun yarn and earth works complete all as specified and directed.
Repairs to leakage of 200 mm dia bore pipe, fittings, such as tee, bends, tail pieces, connecting pieces etc including making new run lead joints by using spun yarn and earth works complete all as specified and directed.
Repairs to leakage of 150 mm dia bore pipe, fittings, such as tee, bends, tail pieces, connecting pieces etc including making new run lead joints by using spun yarn and earth works complete all as specified and directed.
Repairs to leakage of 100 mm dia bore pipe, fittings, such as tee, bends, tail pieces, connecting pieces etc including making new run lead joints by using spun yarn and earth works complete all as specified and directed.
Repairs to leakage of 80 mm dia bore pipe, fittings, such as tee, bends, tail pieces, connecting pieces etc including making new run lead joints by using spun yarn and earth works complete all as specified and directed.
S&F in repair 150 mm bore foot valve, cast iron body, manufacturing standard IS 4038, pressure rating PN-2 with flanged and drilled ends cast iron body, Hinged leather seat, ISI marked, including all joints, bolts and nuts, washers, including taking up / down old unserviceable valve from any position and any addition / alteration for fixing required complete all as specified and as directed.
S&F in repair 100 mm bore foot valve, cast iron body, manufacturing standard IS 4038, pressure rating PN-2 with flanged and drilled ends cast iron body, Hinged leather seat, ISI marked, including all joints, bolts and nuts, washers, including taking up / down old unserviceable valve from any position and any addition / alteration for fixing required complete all as specified and as directed.
S & F in repair stainless steel spindle of sluice valve 200mm bore including check nuts complete all as specified and directed.
S & F in repair stainless steel spindle of sluice valve 150mm bore including check nuts complete all as specified and directed.
S & F in repair stainless steel spindle of sluice valve 100mm bore including check nuts complete all as specified and directed.
S & F in repair stainless steel spindle of sluice valve 80mm bore including check nuts complete all as specified and directed.
S&F in repair change over switch front operated, open excution type, 4 pole, 415 Volts, 100 Amps including making all incoming/outgoing cable connections using new aluminium lugs complete all as specified and directed. Make L&T FN100TPN
S&F in repair change over switch front operated, open excution type, 4 pole, 415 Volts, 250 Amps including making all incoming/outgoing cable connections using new aluminium lugs complete all as specified and directed. Make L&T FN250TPN
S&F in repair change over switch front operated, open excution type, 4 pole, 415 Volts, 400 Amps including making all incoming/outgoing cable connections using new aluminium lugs complete all as specified and directed. Make L&T Model FP400TPN
Sampling and testing of water for the conformation of Desirable / permissible limit of following requirements for "DRINKING WATER" as per IS : 10500-1991 from govt approved laboratory) including transportaion of warer complete all as specified and directed (a) Bacterioligical requirements: Testing of coliform Organisms/100ml. (b) Chemical requirements : Testing of colour hazen unit max odour taste turbidity NTU max, pH value, total hardness (as CaCo3) mg/lmax, iron (as FE) mg/l max. (c) Desorable Charactreristics : Testing of dissolved solids mg/l max, Calcium (as CA mg/l mnax, magnesium (as Mg) mg/l max, Copper (as Cu)mg/l max, Manganese (as Mn) mg/l max, Shulphate (as SO4) mg/l, max, nitrate (as NO3) Mg/l phenolic compound mg/l max, mercury (as Mg) mg/l max, Cadmium (as Cd) Mg/l max, Selenium (as Se) mg/l max, Arsenic (as As) mg/l max, Cyanide (as CN) mg/l max, Lead (as Pb) mg/l max, Zinc (as An) mg/l max, Chromium (as Cr+( mg/l max, Mineral Oil, mg/l max. Note :- Testing of raw water is mandetory at every quarter failing which a recovary of Rs 2000 per test shall be recovered from the contractor.
Supply and fixing 100 watt , LED security Flood light made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,mounted on top of the pole with cap type bracket having lenght not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light . including PVC insulated three core 23/0.0076 copper cable and including suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed.
S&F in repair of wiring on wall/surface laying in trenches PVC insulated 1.5 Sqmm, 3 core copper conductor 1100 Volts grade cable drawn through PVC conduit pipe of 20mm dia complete all as specified and directed.
S&F Altoch dosing system Model ADS- PRO consisting of receptacle for power free automatic water sanitiser / conditioning treament station with proportional dosing arrangment and custom cover for power free automatic water sanitiser / conditioning treatment station with proportional dosing arrangment. Make :- Declibac Item NR 153120AP or equivalent.
S&F chlorine refill tabelets (contained in plastic cylindrical refill of sealed disposable sanitiser cylinder dia 2.5 inches (tolerance + 0.5 inches) (cylinder height minimum 10.0 inches (tolerance + 0.5 inches), minium volume of water disinfected by each chlorine tablets refill to obtain disinfetion activity of 1 PPM on spot as per safety & health hazard aspectds on usage of the product media for regular drinking water disinfection eliminating. hweavy metal contaminates (like mecury & lead) in product media must be below detectable limit (BDL) using for disinfection of drinking water complete all as specified and as direted.
M/S SHRINATH CONTRACTION
M/s P.N.C. Engineers
rohan traders
VISHESH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .